9-4 Expansion Key Service Unit (EKSU) The BKSU al so h as the se st and ard fe at ure s: †1 Program Module Unit (PMU) that provides system software †1 DTMF Receiver (for DISA applications) †2 Pr ogr amma ble r el ays wit h d r y cont act s r at ed at 2 4V DC, 1 amp †1ExternalPagePort †Battery Backu p for System Database †1 Music In put (MOH/BGM) The BKSU main b oard can accep t the following modules : †1 M is ce l lan eous Se r vi ce Uni t (M I SU) t hat p rovi de s t wo 9 -p in RS2 32 C ports and second music source circuitry †1 Mod em U nit (MODU, 9600 ba ud modem) f or rem ote administration †1 4- c ir c uit D TM F Re c ei ve r ( DTM F -A ) pr ovi des 4 DT M F r ec e ive rs (S LT ) †1 3x8 CKIB or 3x8 CSIB (one CKIB installed in every BKSU standard) A numbe r 12 AWG coppe r wire should b e used to ground b etwee n the gro und s ource and the BKS U (25 fe et ma ximum ). Atta ch this wire to the ground lug on the lower right side of the BKSU. Expansion Key Service Unit (EKSU) TheTr iad-SExpansion Key Service Unit (EKSU) is a wall-mountable cabinet that hou ses the circuitry to sup port two 3x8 b oard s. The EKS U mounts d irectly abov e the BKSU . The EKSU has cables that connect power and digital communications form the EKSU to the BKSU. The E KSU ca n provide six ad ditional CO lines and s ix teen station growth tha t ta kes t he syst e m t o i t’s maximum configuration of twelve CO lines and 32 s ta ti o ns. The E KSU contains one expa nsion interface board (EIB) which includ es powe r suppl y and conn ect or int er fa ce b uses . A n umbe r 1 2 AWG cop per wire should be used to groun d between the groun d source a nd the BKS U (25 feet maximum). Attach this wire to the ground lug on the right side of the E K SU.
Pe r ip h e ra l B o a r d s 9 - 5 Pe ri p h e r a l B o ar ds 3 C O Lin e an d 8 D igital Statio n Board (C KIB) This board p rovide s three loop s ta rt CO lin e interface s a nd e ig ht Digital Key Te le phone inte rf aces . T his boa rd can b e ins ta lled in the BKS U or EKS U. If a ll C KIB b oards a re installe d in the BKSU and EKSU, the syste m capacity is 12 CO lines and 32 digital stations. TheCOlineinterfacesarebroughtoutontherightsideoftheBKSU/EKSU utilizing RJ11 connectors. The digital station interfaces are brought out utilizin g a 50-p in amphe nol conne ctor on the left s ide of th e BKS U/EKSU. The station interface for stations 100-107 also provides the wiring int e rfa c e f or the ad dit i onal fe at ure s t hat r eq uir e inp ut/ out put connections. The se fe ature s a re mus ic s ource s, re lay conne ctions , an d external p age conne ctions. 3 C O Lin e an d 8 Sin gle Li ne Stati on Board (CSIB) This board p rovide s three loop s ta rt CO lin e interface s a nd e ig ht Single Line T elep hone inte rfa ces. T hese interface s s upport 2500 touch ton e te le phone i nst r ument s and/or voi ce mai l int er face s. Thi s boar d ca n be ins ta ll ed in the BKS U or EKSU . A maxi mum of thr ee CS IBs m ay be in stall e d be twe en the B K S U/E K SU to pro vid e a max imu m o f 2 4 si ngl e li ne int e rfa c es. TheCOlineinterfacesarebroughtoutontherightsideoftheBKSU/EKSU utilizing RJ11 connectors. The digital station interfaces are brought out utilizin g a 50-p in amphe nol conne ctor on the left s ide of th e BKS U/EKSU. The C SI B can a ccept t he opt ion al Mess age Wa it Uni t (MSGU) t o pr ovi de mes sag e wa it l amp capa bi li ty to th e e ig ht ins tr ume nts at t ached .
9-6 Opt ion al Bo ards Optio nal Boards Mi sce llaneo us Se rv ice Unit (MISU) Thi s boar d p rovi de s t wo RS 23 2 C i nt er face s f or syst e m pr ogr ammi ng, calle r ID, and SMDR ap plications. T he board a lso conta ins a s econd music source to increase the mu sic channels in the system from one to two. The board installs in the BKSU. Mo dem U ni t (M O D U ) This board provides a 9600 baud modem for remote system pr ogra mmi ng. T he mode m i s a ccess ed by dia li ng s ta ti on 499. MessageWaitUnit(MSGU) This board provides message wait lamp capability to the eight attached SLT instrum ents. This board is ins ta lled on the CSIB. Each CS IB m ay ha ve one MSGU installed. DT M F R ece iver Uni t (D T MF- A ) Thi s boar d p rovi de s f our DTM F re cei ve rs for C SI B use an d sho uld be installed any time a CSIB board is installed in the system. The BKSU supp orts one DTMF -A unit. Th e mod em may not al ways con nect at 9600 b ps. If y ou enco unter a si tuati on wh ere you c anno t conn ect a t 9600 bp s, ch ang e yo ur comp uter’s ba ud rate to 4800 b ps.
Opt ion al Boards 9-7 Figure 9-1:STARPLUSTr iad-SSystem Table 9- 1: Digital System Capacity BKSU Capacity CO /P BX /C en trex Li nes Stat ion Di gi tal Tel epho ne S ing le L i ne Te le p ho ne6 lin es ma x imu m ( 3 per CK IB /C SIB bo a rd ) 1 6 ma x imu m ( 8 p er C K IB bo a rd) 8maximum(8perCSIBboard) BKSU + EKSU Capacit y CO /P BX /C en trex Li nes: Stat ion Di gi tal Tel epho ne Sing le l in e Telep h on e1 2 li nes ma x im um 3 2 ma x imu m ( 8 p er C K IB bo a rd) 2 4 ma x imu m (8 p er C SI B b oa rd ) (System m ax: 1 2 lines, 8 digital telephones, 24 SLT) DTMF Receiver Basic: 1 each W it h DTMF4-A: 5 (pro vi des 4 additi onal rec eivers) The dial pulse function is not available in theTr i a d - S system . D TMF Send er U nl imi ted I /O Po rts 2 ma xi mu m wi th MISU Conference Ci r cu it Par ti es5 conference per system 8 parties per conference (5 of the 8 can be external) Basic KS UC P UP M U CKIB CSIB MSGU DTMF4-A MISB MODUEK SU CK IB C SIB MSGU E I B
9-8 Opt ion al Bo ards D ISA C i rcu it 1 2 CO l in es ma y be p ro gr am med simu lt an eou sly At tend ant s U p to 3 statio n s can be d esig nat ed as atten d ants Digital DSS/ DLS Unit s 8 m axi mum - each DSS/DLS unit requires 1 stati on port and reduces station capacity by 1. DSS/DLS maps may not be duplicated at a st at ion. One station may have up to three DSS/DLS unit s associ at ed w ith it . L oo p Sup erv isi on D isco nn ect 7 00 msec . du ra ti on - CO o r I nt erna l Ca l l to SLT Pag e Zo nes In tern al Pa gi ng Ext ernal Paging (1 & 2 w ay)8 maximum - software controlled 1maximum Hunt Groups Gro up s Members Ty p e sSo ftwar e sup po r ts up to 8 g ro up s So ftwar e sup po r ts up to 8 st at ion s in each g rou p St at io n, P ilo t H un tin g, o r P ilo t R ing Al l Mem bers Vo ic e M a il G ro up s Gro up s Members (Por ts) In tegr at ed Met ho d VM Message Wait VM D is c on ne c t S i gn a lSo ftwar e sup po r ts up to 8 g ro up s So ftwa r e sup po r ts up to 24 st at io ns I n-b a n d si gn a lli ng (DTMF) P rog ra mm ab le 12-d igi t (D TMF) st rin g I f no d ig it s a re p rog ra mm ed, 15 seco nd s of silen ce fo llo wed by busy tone ACD Gro ups Gro up s Members RAN Announcements Ca l ls in Q ue u eSo ftwa r e sup po r ts up to 16 g ro up s So ftwa r e sup po r ts up to 32 st at io ns i n ea c h g rou p Ei ght R AN A nnounc ement s per syst em, 3 per ACD group All CO lines may be queued for an ACD group UCD Groups Gro up s Members RAN Announcements Ca l ls in Q ue u eSo ftwar e sup po r ts up to 8 g ro up s So ftwar e sup po r ts up to 8 st at ion s in each g rou p Ei ght R AN A nnounc ement s per syst em, 3 per UCD gro up All CO lines may be queued for a UCD group Table 9- 1: Digital System Capacity
Opt ion al Boards 9-9 Table 9-2: Electrical Specifications AC I npu t to Pow er Supply 117 VAC±10%, 60H z si ng le phase Power Consumption 74 watts Powe r S up pl y Fu s e - A C In pu t 1 A /2 5 0 V Lo ng itu d ina l Ba la n ce 60 d B fro m 20 0 Hz to 1,000 H z 40 dB fro m 1. 000 H z to 40,000 Hz Idle Channel Noise Less t han 15 dBrnc0 for al l connections Cr oss Tal k At tenuatio n Greater than 80 dB m Stati on to CO and Station to Station Si ng le Freq uen c y D ist or tio n 300 H z - 3,40 0 HzStation to CO and Stati on to Station: Bet ter th an 2.0% or 34 dB fo r an ou tput Le v e l - 3 0 d Bm to 0 dB m Rin g ing Sen siti vi ty 16 H z to 30 H z a t 4 0 Vrm s mi nim um 03 H z to 67 H z at 5 0 Vrm s mi nim um CO Line Signaling - DTMF Fr equency pair at -5 dBm ± 0.5 dBm Fr equenc y tol eranc e ± 1.5% CO Line Signaling - Dial Pulse 10 PPS Input Level +10 dB m axim um Music Sou rc e Music on Hold/Background Music Input 600 ohm input at 0 dBm maximum from mu sic so ur ce Co nt ac t R a tin g Mu lti pu rp ose R ela y 1 a mp @ 2 4 V DC (tw o o n MB U b o ar d) Ex te rnal Pag e Po rt Out put Impedance Output Power without Compression600 o hm @ 0 dB m 5 milli-watt maximum CSA Fil e Nu mber (N RTL/C) LR 85633
9-10 Opt ion al Bo ards Table 9-3: Environmental Specifications Operati ng Tem perat ure 32ºto 104ºF0ºto 40ºC Op ti mum Tem perat ure 60ºto 80ºF15ºto 26ºC St orag e Temp eratu re -40ºto 140ºF4ºto 60ºC R elati ve H um id ity 5% to 90% n on -co nd ensi ng H eat Dissipati on (BTU) 1481 B TU/ Ho ur Table 9-4: Loop Limits Digital Telepho nes Maxi mum lengt h o f stati on lo op: 1,000 feet of 24 AW G (2 w ire, i nside w iri ng, twi sted ca b le) Sin gl e Line Telepho nes 2,000 feet of 24 AW G Table 9-5: Dialing Specifications DTMF Dialing Frequency Deviati on Rise Time Duration of DTMF Signal Interdigit Time±1.5% 5msec 70-100 msec 100-130 msec Pu lse D ia lin g Pu lse D ia l ing R at e Pulse Break/Make Duration10 pps 60/4 0 or 66/33 CO T y pe Lo op s ta r t, 600 oh m, c urr ent s ens in g Ta ble 9-6: Trunk O rdering Information: Public Network Line s System Port Specification, Facility Interface and Service Order Codes Interface CardRinge r Equiv alent Number (REN)Facility Line InterfaceJac k T ype Loo p Start 1.3 B 02LS2 RJ11C
Opt ion al Boards 9 -11 Ta ble 9-7 : P hysi c al Dim ensi o ns and Wei ght Item Height Width De pth Weight Tr iad-SB asic Key Servi ce U nit 13. 6 in 10 .85 in 4.9 in 5. 3 Kg Tr iad-SExpansio n Key Servic e Un it 13. 6 in 10 .85 in 4.9 in 4. 6 Kg Table 9-8: Miscellaneous Specifications Memo ry Pro gr a mma b le R ead -On ly Memo ry (EPROM) Random Access Memory (RAM)1Megabyte 384 K expandable to 640 K Telep h on e Tra n smit ter Elec tret mic co mp a tib le CO/ PBX/Centrex Paths Ba si c K SU Basi c K SU + Expansion K SU In terc om Paths3/6 CO/PBX/Centrex talkpaths (non- bl oc k in g) 12 C O /PB X/ C e ntr e x t al k pa th s ( no n-b l ock i ng ) Non-blocking Musi c Channel s Mu sic On -H old /B a ck gr ou nd Mu si c 2 ch a nn els w ith o pt ion a l MI SU p er sy stem (1 MOH, 1 BGM [differ ent sour ces]) Add it ion a l m us ic c ha nn e ls a v a ila b le t hro ug h CO l in e s. Co nn e ct io ns u p to 8 ma xi mu m op ti on al . Talk b atter y requ ire d. Acc ou nt Co des N umb er of D ig its Per Acc ou nt Co de Number of Ac count Codes - Unver ified Number of Ac count Codes - Veri fiedUp to 12 u nv erif i ed d ig it s Un lim ited 250 ac cou nt co des Di al in g M e mor y Station Speed Dialing System Speed Di al ing20 b in s per stati on (24 d igi ts) 80 bin s per syst em (24 dig it s)
9-12 Opt ion al Bo ards Table9-9:SingleLineAudibleSignals Type of Signal F re que ncy Signal Dura tion SI NGLE LINE SIGNA LS In co mi ng CO Lin e 20 Hz 9 0 VAC .8 on / 2. 8 off repeated Intercom ToneRinging 20 Hz90VAC .2 on /.4 off/ .6on / 3.0off repeated Transferr ed CO Line 20 Hz 9 0 VAC .8 on / 2. 8 off repeated CO Li ne R ecall 20 Hz 9 0 VAC .8 on / .2 off / .2 on / .2 off CO Queue Call Back 20 Hz 9 0 VAC 1 sec on / 2 sec off repeated SINGLE LINE CONFIDENCE TONES In terc om Ri ng bac k 440 + 480 .8 on / 2. 8 off repeated Transferr ed CO Line 440 + 480 .8 on / 2. 8 off repeated C a ll An n ou nc e 440 .8 on / 2. 8 of f rep ea ted Bu sy To ne 480 + 620 .5 on / .5 off repeated Erro r Ton e 480 + 620 .2 on / .2 off repeated In terc om Di al To ne 350 + 440 Steady DND To ne 350 + 440 .4 on / .4 o ff / .2 on / .2 o ff / .2 on repeated Pag ing Con firm at io n Ton e 350 + 440 1 sec o n Conferenc e Tim e-out To ne 440 Pr ogrammable St eady To ne Con firm at io n Ton e 350 + 440 .8 on / .8 off 3 bu rsts
Opt ion al Boards 9 -13 Table 9-10: Digital Station Visual Signals - CO Line Buttons Feature / Function Flash Rates LED Color Inc om in g C O Ri ng in g 30 ip m fla sh R ed Tra n sfer red CO R in gi ng 120 ip m fla sh R ed CO L in e Rec a lli ng 480 ip m flu tter R ed Sy stem Ho ld 60 ip m d ou bl e win k R ed Ex cl usi ve H ol d (I -Ho ld ) 120 ip m fla sh Green I-H old ( sy stem) 60 ip m wi nk Green CO L in e Q ue u e C al l B ac k 4 8 0 ip m f lu t t e r R e d CO L in e in Us e O n s te a dy R e d CO L in e Id le O f f O f f Ex cl usi ve H ol d (o th er stati on s) On steady R ed Ta b le 9- 11 : D i g i tal S tat i o n V i su al Si g n al s - D S S / B L F B u tt o ns Fe at ure / Funct i on Fl as h Ra te s LE D Col o r Off- Hook (busy) On st eady Red Inc om in g I nter co m R ing 120 i pm flu tter Red Call Anno unce (H or P mo de) Steady Red Messag e Wa it in g C a ll Ba ck 120 i pm flu tter Red StationinDo NotDisturb 60ipm double flash Red Ca mp On (by sta ti on ) 120 i pm flu tter Red Auto ma ti c C a ll B a ck 120 i pm fla sh Red St ation Unavailable (ACD/UCD) 60 ipm flash Red