Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual
Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual
Have a look at the manual Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Shipping, Receiving, and Installation Information PFT CABLE/ MEFINAL TOOTHLOCKWASHERSGROUND WIRE /(CONNECTS TO CABINET GROUND STUD) I REAR CABLE PANEL ASSEMBLV AOAPTEk PLATE (OPTIONAL)IPCM CABLES (BAYS 4.5.6.7),NTERdBlNETCABLE ASSEMBLV KA0683ElFigure 5-2 Installation of an Intercabinet Cable Assembly (672 port) Page 53
SECTION MITL9109-094-200-NACHART 5-8 INSTALL AN ANALOG BAY 3 KIT INTO AN SX-ZOO CABINET WARNING THESE INSTRUCTIONS MUST BE FOLLOWED EXPLICITLY SINCE THEY INVOLVE WORK WITH AND CHANGES TO THE PRIMARY POWER SUPPLY TC THE UNIT. Only persons who have successfully completed a MITEL Installation and Maintenance training course for the SX-200 DIGITAL PABX should perform this procedure.Step 1.ActionUnpack kit and inspect contents for loose, damaged, or missing items.Comments 2.Open Control cabinet doors, set power -switches to OFF, set main breaker on rear door to OFF, and remove line cord from wall outlet. 3.Install the ground wire (between frame andBay 3 card file) to the frame.Refer to Figure 5-3. 4.Remove rear door fan assembly - unplug fan supply cord, detach cord strain relief at stud - remove door ground wire at door stud - remove door - retain hardware 5.Remove rear door - unplug AC distribution unit supply cord and unfasten cord strain relief - remove door ground wire at cabinet ground stud - loosen four screws securing rear door retaining bar - slide retaining bar up, releasing the rear door - replace lower right hand retaining barsecuring screw with #lO x 7/8” screw from kit (to secure main power cable strain relief). 6.Unpack the Interconnect and Power Fail Transfer (PFT) cards; inspect for loose, damaged, or missing items.The optional PFT card should be installed concurrently. 7.Install the Interconnect card on the upper left side of the cabinet (from rear) with six sets (screws, lockwashers, and flat washers). 8.If a PFT card is to be installed also, remove the eight securing screws from the front of the Control shelf and slide it forward.Page 54
Shipping, Receiving, and Installation InformationStepAction 9. 10. 11. 12. 13. 14. 15. 16. 17.CHART 5-8 (CONT’D) INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 CABINET CommentsInstall the PFT card below the Interconnectcard with six sets (8-32 x 318” screws, lockwashers, flat washers).The PFT card is optional. Replace the Control shelf with its associated hardware.Be sure that the antistatic wrist strap is securely in its original location. Connect the wiring harness, 2nd D.C., (pn 103148501) between the Interconnect card and the PFT card. InterconnectColour PFT TB301-1BrownTB-3 TB30 l-2 BlueTB-5 TB30 l-3 ncTB30 l-4 WhiteTB-6 TB30 l-5 RedTB-7 TB30 l-6 OrangeTB-4 TB30 l-7 YellowTB-2 Install cutover monitor cable (pn 114905501)from P18 on Interconnect card to TB-7 on PFT card. Secure connector with a tie wrap. Connect ground strap (pn 105671501) from TB301-3 to Control shelf frame with 6-32 x 5/16” screw, lockwasher and external tooth lockwasher. defer to Figure 5-4. Unpack shelf; check backplane and shelf for cracks, bent pins, loose or missing items, or other damage. Connect brown backplane wirenear TBl to shelf frame with 6-32 x 3/8” screw, external tooth lockwasher, lockwasher, nut, if not already connected. Place shelf onto shelf guides and secure from Front with eight lo-32 screws, lockwashers, and flat washers. Connect ground wire found attached to upper right corner of Control shelf frame to lower right corner of Peripheral shelf (Bay 3), using6-32 x 3/8” screw, external lock washer, lockwasher, and nut. Route the DC power cable (pn 114904501) within the cabinet. The cable is routed up from the power supply, across the top of the cabinet, and down to the terminal blocks on the backplane and interconnect card. Iefer to Figure 4-7 for cable ‘outing. Refer to Figure 5-5 for :able connections. Page 55
SECTION MITL9109-094-200-NACHART 5-8 (CONT’D) INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 CABINET StepActionComments 18.Connect the DC power cable leads to the Bay 3 backplane, as follows:TBI-1 purple (-10 V) TBI-2 yellow (-5 V) TBI-3 brown (0 V) TBI-4 orange (+8 V) TBI-5 nc TB2-1 nc TB2-2 gray (90 V) TB2-3 nc TB2-4 grn/yel (gnd to card file frame) TB2-5 blue (-48 V) 19.Connect the DC power cable to the Interconnect card as follows: TB301-1 brown (0 V) TB301-2 blue (-48 V) TB301-3 braided gnd cable to Control shelf frame and green/yellow from cable TB301-4 nc TB301-5 nc TB301-6 orange (+8 V) TB301-7 yellow (-5 V) 20.Route intershelf PCM Control cabinet cable into space between shelves; connect marked end to J’l7A on the Control backplane. 21.Install cables between Bay 3 and Interconnect card; 18 inch (pn 114909501) between P6 and P16, and 25 inch (pn 114910501) between P5 and P17. Secure each cable with a cable tie and a connector screw. 22.Install a surge clamp onto the Bay 3 backplaneat slot 16, pins 9 to 32; ensure that surge clamp is installed right side up (see label on clamp). 23.Install cables between Bay 3 and distribution frame. 24.Unpack rear door power supply assembly;If damaged or wrong type, repack inspect for physical damage, and correct type.in original container and return with completed Damage Report.Page 56
Shipping, Receiving, and installation Information CHART 5-8 (CONT’D) INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 CABINET StepAction Comments 25.Place rear door power supply onto shim washer and lower door support and lock into closed position (this will hold the rear door power supply while installing upper support). 26.Install upper support over power supply hingepin and secure to cabinet with 4 sets (IO-32 screw, lockwasher). 27.Connect ground lead to cabinet ground stud using hardware from original door. 28.Plug AC distribution unit assembly supply cord into the power supply outlet. Attach cable strain relief to power supply door by removing power supply cover screw and replacing itwith an 8-32 x 5/8” long screw which also secures the cable strain relief. 29.Connect the DC power cable connector to the power supply. Attach power cable strain relief by removing a power supply cover hold downscrew and replacing it with an 8-32 x 5/8” screw to fasten cable strain relief to cover. 30. 31. 32. 33. Install rear door fan assembly and two nuts on hinge bracket. Attach door ground wire to door ground stud; use previously removed hardware. Plug fan power supply cord into connector on fan door and attach cord strain relief to stud on fan door; use previously removed hardware. Put on the antistatic wrist strap.Always wear the antistatic wrist strap when handling printed circuit cards. 34. 35.Unpack each printed circuit card and insert it into its assigned slot. Connect PCM cable previously routed between the shelves to connector J2 on the front ofthe Digital Interface Card at Bay 3, Slot 18. 36.Power up PABX and reprogram using Customer Data Entry. Page 57
SECTION MITL9109-094-200-NACHART 5-9 INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 UNIVERSAL CABINET WARNING THESE INSTRUCTIONS MUST BE FOLLOWED EXPLICITLY SINCE THEY INVOLVE WORK WITH AND CHANGES TO THE PRIMARY POWER SUPPLY OF THE UNIT. Only persons who have successfully completed a MITEL Installation and Maintenance training course for the SX-200 DIGITAL PABX should perform this procedure.Step 1.ActionUnpack kit contents and inspect for loose, damaged, or missing items. Refer to parts list.Comments 2.Open Control cabinet doors, set BPS switches to OFF, set main breaker on rear door to OFF, and remove line cord from wall outlet. 3.Install ground wire (between frame and Bay 3Refer to Figure 5-3. card file) to frame (note: the card file has not been installed yet), therefore connect only frame end now). 4. 5.Install Interconnect card with five screwsTop right mounting hole goes to(IO-32 x l/2) on the upper left side of thesixth hole from top of center side cabinet (viewed from rear). rail. Install shelf rails l/2 inch above Control shelf,Screws into third hole above and secure to cabinet vertical frame usingControl shelf, with horizontalIO-32 x l/2 screws (shorter brackets - 13support below, pointing inward. inches long). 6. 7.Unpack shelf; check backplane and shelf for cracks, bent pins, loose or missing items, or other damage. Place shelf onto shelf rails and secure to frontframe with eight IO-32 screws. 8.Connect ground wires from frames and fromRefer to Figure 5-3 and Figure 5-4 backplane (brown wire near TBI, grn/yel wirefor installation details.from TB2-4) to card file side panel. Use a 6-32 screw, external tooth washer, lockwasher and nut. 9. Install power supply control panel above shelf and route leads from switch and LED to rear of cabinet. 10.At rear of cabinet, unplug AC wiring from door, fan assembly, and remove ground strap from frame stud; retain hardware. Remove door. 11.Connect braided wire (120832501) from upperRefer to Figure 5-4. side panel to Interconnect card (TB301-3).Page 58
Shipping, Receiving, and installation Information CHART 5-g (CONT’D) INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 UNIVERSAL CABINET StepAction Comments 12.Route the DC power cable (pn 114904501)Refer to Figure 4-7 and Figure within the cabinet. The cable is routed up from 5-5. the power supply, across the top of the cabinet, and down to the terminal blocks on ’the backplane and Interconnect card. 13.Connect the DC power cable leads to the Bay 3 backplane, as follows: TBI-1 purple (-10 V) TBI-2 yellow (-5 V) TBl-3 brown (0 V) TBl-4 orange (+8 V) TBl-5 nc TB2-1 nc TB2-2 gray (90 V) TB2-3 nc TB2-4 grn/yel (gnd to card file frame) TB2-5 blue (-48 V) 14.Connect the DC power cable to the Interconnect card as follows: TB301-1 brown (0 V) TB301-2 blue (-48 V) TB301-3 braided gnd cable to Control shelf frame and green/yellow wire from cable. TB301-4 nc TB301-5 nc TB30’l-6 orange (+8 V) TB301-7 yellow (-5 V) 15.Connect leads from switch and LED on power supply control panel to mating connector on main DC harness; connect OOT cable connector to P303 on Interconnect card. 16.Route intershelf PCM Control cabinet cable into space between shelves; connect marked end to J17A on the Control backplane; the cable should point downwards from the connector. 17.Install cables between Bay 3 and Interconnect card; 18 inch (pn 114909501) between P6 and P16, and 25 inch (pn 114910501) between P5 and P17. Secure each cable with a cable tie and a connector screw. Page 59
CHART 5-9 (CONT’D)INSTALL AN ANALOG BAY 3 KIT INTO AN SX-ZOO UNIVERSAL CABINET StepActionComments 18.install a surge clamp onto the Bay 3 backplaneat slot 16, pins 9 to 32; ensure that surge clamp is installed right side up (see label on clamp). 19.Install cables between Bay 3 and distribution frame. 20.Remove six screws that hold the rear cableRefer to Figure 5-6. panel to cabinet; install lower door supportonto cabinet and secure with IO-32 screws in eleventh hole from bottom, with the bracket above screw pointing out. 21. 22.Replace rear cable panel onto cabinet. Unpack rear door power supply assembly; ,If damaged or wrong type, repack inspect for physical damage, and correct type.in original container and return with completed Damage Report. 23.Place rear door power supply onto lower door support, using shim washer, and lock door into closed position (this will hold the rear door power supply while installing upper support). 24.Install upper support and shim washer overRefer to Figure 5-7. power supply hinge pin and secure to cabinetwith lo-32 screws. 25.Open rear door and install blanking plate to cover openings in left side frame, and fasten with screw, lockwasher, and nut. Remove hinges from right side of frame. 26.Connect ground lead from rear door power supply to frame ground stud using existing hardware. 27.Plug AC distribution unit assembly supply cord into the power supply outlet. Attach cable strain relief to power supply door by removing power supply cover screw and replacing itwith an 8-32 x 5/8” long screw which also secures the cable strain relief. Secure AC cable to frame of cabinet near center of power supply. 28.Connect the DC power cable connector to the power supply. Attach power cable strain relief by removing a power supply cover hold downscrew and replacing it with an 8-32 x 5/8” screw to fasten cable strain relief to cover. Page 60
Shipping, Receiving, and Installation InformationStepActionIComments 29. 30. 31. 32.Remove the old hinge brackets for the rear door from the cabinet frame. 33.Put on the antistatic wrist strap. 34. 35. 36. StepAction 1. 2. 3. 4. 5. 6.CHART 5-9 (CONT’D) INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 UNIVERSAL CABINET CAUTION: This upgrade and installation procedure is to be performed only by qualified per- Install rear door fan assembly and tighten two nuts on hinge bracket. Attach door ground wire from door groundstud to frame using IO-32 screw and external tooth lockwasher. Plug fan power supply cord into connector on fan door and attach cord strain relief to stud on fan door.Always wear the antistatic wrist strap when handling printed circuit cards. Unpack each printed circuit card and insert it into its assigned slot. Connect PCM cable previously routed between the shelves to connector J2 on the front ofthe Digital Interface Card at Bay 3, slot 18. Power up PABX and reprogram usingCustomer Data Entrv.CHART 5-10 INSTALL DIGITAL PERIPHERAL BAY sonnel who have successfully completed a MITEL Installation and Maintenance Course for the SX-200 DIGITAL PABX. INSTALL DIGITAL BAY AND SHELFS Unpack and inspect contents of kit.Power down system. Open front door and slide digital peripheral shelf onto top of existing shelf, and fastento front rails with eight lo-32 x 0.5 in. screws, as shown in Figure 5-8. Install filler plate above shelf, and fasten to front rails with two lo-32 x 0.5 in. screws, as shown in Figure 5-8.At front of cabinet, attach antistatic wrist strap to your wrist, and install Bay Power SUPPlY. Open rear door, and connect ground wires from new shelf as shown in Figure 5-9.Use lo-32 x 0.5 in. screw and external tooth lock washer to connect to side frame. Refer to Figure 5-10 and Figure 5-12 for details of ground connections. A 336 port peripheral shelf is shown; however, 672 port peripheral shelves are the same. Page 61
SECTION MITLSI 09-094-200-NA, GREEN, MOUNTINGrSCREWS1 KAll014ElRFigure 5-3 Cardfile to Frame and Backplane Ground Connections Page 62