Have a look at the manual Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
‘: :::... . . . Step 1 2 3 -~~~ otccess MAINTENANCE spplication. Press 1[SYSTEM softkey). Press 1 (SET softkey). 4Press 2 (TIME softkey). 5 6Enter time in either 12- or 24-hour format. Press 0 (ENTER softkey). 7 8Repeat Step 3 through Step 5. Press 1 (PM softkey). 9Press 0 (ENTER softkey).Setting System Time 2.05System time may be set from the Maintenance Terminal. The new time will be reflected on the Maintenance Terminal display, the Attendant Console LCD display, and the SUPERSET 4 telephone LCC display. Chart 2-3 shows the steps for testing setting of system time. CHART 2-3 SETTING SYSTEM TIME ActionVerify System responds by displaying Maintenance menu. Softkey prompts change. System Level is accessed. Command line responds with: SETand softkey prompts change. Command line responds with: SET TIME enter Time HH:MM snd softkeys are disabled. Command line shows digits entered, and PM, ENTER and CANCEL softkeys are enabled. Command line clears, and new time is displayed. Softkeyprompts return to system level functions. Command line shows digits entered, and PM, ENTER and CANCEL softkeys are enabled. Command line shows: SET TIME xX:xX PM and ENTER and CANCEL softkeys are enabled. New time is displayed. Softkey prompts change, returning to system level format. Test completed.
System Test Procedures: .>;;.:Setting System Time 2.05System time may be set from the Maintenance Terminal. The new time will be reflected on the Maintenance Terminal display, the Attendant Console LCD display, and the SUPERSET 4 telephone LCL’ display. Chart 2-3 shows the steps for testing setting of system time. CHART 2-3 SETTING SYSTEM TIME StepActionVerify 1Access MAINTENANCESystem responds by displaying Maintenance menu. application. 2Press 1Softkey prompts change. System Level is accessed. (SYSTEM softkey). 3Press 1 (SET softkey).Command line responds with: SETand softkey prompts change. 4Press 2 (TIME softkey).Command line responds with: SET TIME enter Time HH:MM and softkeys are disabled. 5Enter time in eitherCommand line shows digits entered, 12- or 24-hour format.and PM, ENTER and CANCEL softkeys are enabled. 6Press 0 (ENTER softkey).Command line clears, and new time is displayed. Softkeyprompts return to system level functions. 7Repeat Step 3 throughCommand line shows digits entered, and PM, ENTER and Step 5.CANCEL softkeys are enabled. 8Press 1 (PM softkey).Command line shows: SET TIME xX:xX PM and ENTER and CANCEL softkeys are enabled. 9Press 0 (ENTER softkey).New time is displayed. Softkey prompts change, returning to system level format. Test completed. Page 7
SECTION MITLSI 09-094-320-NAChanging Passwords 2.06Passwords may be changed by a user for his or her access level, and all lower access levels. At the INSTALLER access level, all passwords may be changed. Chart 2-4 shows the steps for testing changing passwords at the INSTALLER level. If a different ac- cess level is chosen, only those levels equal to or below the chosen level will be available for testing setting of passwords. CHART 2-4 CHANGING PASSWORDS StepActionVerify 1Access MAINTENANCESystem responds by displaying Maintenance menu. application. 2Press 1Softkey prompts change. System Level is accessed. (SYSTEM softkey). 3Press 1 (SET softkey).Command line responds with: SETand softkey prompts change. 4Press 3 (PASSWORDCommand line responds with: softkey).’ SET PASSWORDand softkey prompts change. 5Press 7 (INSTALLERCommand line responds with: softkey). SET PASSWORD INSTALLERand softkey prompts clear except for CANCEL and ENTER. 6Press 0 (ENTER softkey).Command line responds with: Enter Old Password then press RETURN/ENTER: and no softkey prompts are displayed. Page 8
System Test Procedures;tep IActionCHART 2-4 (CONT’D) CHANGING PASSWORDSIVerifv 7 10 11 Enter Installer levelPassword is not displayed. password and pressCommand line responds with: RETURN.Enter New Password then press RETURN/ENTER: Enter new Installer password and press RETURN. Enter new Installer password again and press RETURN. Repeat Steps 3 through 9NOTE: When setting passwords for a lower level than the for remaining levels ofcurrent level of access, the prompt “Enter old Password access (SUPERVISOR, MAINTl, MAINT2, then press RETURN:” (as in step 6) will not appear. Instead ATTENDANT).the prompt to enter new password (as in step 7) appears immediately.IPress 6 (QUIT softkey)~ to return to Maintenancemenu. Test completed.if old password was correctly entered or: An invalid or incorrect password was entered if old password was incorrectly entered.If old password was correctly entered go to Step 8; if incorrectly entered, press 5 (CANCEL softkey) and go to Step 7. Password is not displayed. Command line responds with: Enter New Password to verify then press RETURN: Password is not displayed. Command line clears and softkey prompts change to System Level format if password is verified. If password fails to verify, command line responds with: An invalid or incorrect password was entered. If password fails to verify, press 5 (CANCEL softkey) andgo to Step 7. Page 9
SECTION MITL9109-094-320-NASetting Maintenance Terminal Port Baud Rate 2.07 The baud rate of the Maintenance Terminal port may be changed from the value set at the time of login. Any one of six baud rates may be chosen: 300, 600, 1200, 2400, 4800 or 9600 baud. Note that this operation changes the baud rate of ,the Maintenance Terminal port only; the baud rate of the terminal itself must be changed separately. Chart 2-5 shows the steps for testing changing of the Maintenance Terminal port baud rate. CHART 2-5 SETTING MAINTENANCE TERMINAL PORT BAUD RATE StepActionVerify 1Access MAINTENANCESystem responds by displaying Maintenance menu. application. 2Press 1 (SYSTEM softkey).Softkey prompts change. System Level is accessed. 3Press 1 (SET softkey).Command line responds with: SETand softkey prompts change. 4Press 4 (SPEED softkey).Command line responds with: SET SPEEDand softkey prompts change. 5Press 1 (MAINT-PORTCommand line responds with: softkey).SET SPEED MAINT-PORT enter Speed then press RETURN: baud rates and CANCEL softkey prompts are displayed. 6Press the softkey with theCommand line responds with: corresponding baud rateSET SPEED MAINT PORT =-BPS and CANCEL and ENTER softkeys are displayed 7Press 0 (ENTER softkey).Command line responds with: Change terminal speed and press RETURN when ready. Page 10
System Test Procedures CHART 2-5 (CONT’D) SETTING MAINTENANCE TERMINAL PORT BAUD RATE StepActionVerify8Check to ensure terminal speed is the same value as the maintenance port; if different, change terminal speed to coincide with selected Maintenance Port value. 9Press RETURN.Command line clears and softkey prompts return to System Level format. 10Press 6 (QUIT softkey) toTest completed. return to Maintenance menu. Page 11
SECTION MITL9109-094-320-NASetting Printer Port Baud Rate 2.08 The baud rate of the Printer Port may be changed from its default value of 1200 baud. Any one of six baud rates may be chosen: 300, 600, 1200, 2400, 4800 or 9600 baud. Note that this opera- tion changes the baud rate of the Printer Port only; the b,3ud rate of the printer itself must be changed separately. Chart 2-6 shows the steps for testing changing of the Printer Port baud rate. CHART 2-6 SETTING PRINTER PORT BAUD RATE StepActionVerify 1Access MAINTENANCESystem responds by displaying Maintenance menu. application. 2Press 1 (SYSTEM softkey).Softkey prompts change. System Level is accessed. 3Press 1 (SET softkey).Command line responds with: SETand softkey prompts change. 4Press 4 (SPEED softkey).Command line responds with: SET SPEEDand softkey prompts change. 5Press 8 (PRINTER-PORTCommand line responds with: softkey).SET SPEED PRINTER-PORT enter Speed then press RETURN:and no softkey prompts are displayed. 6Press the softkey with theCommand line responds with: corresponding baud rate.SET SPEED PRINTER-PORT XXXX-BPS and CANCEL and ENTER softkeys are displayed. Page 12
System Test Procedures CHART 2-6 (CONT’D) SETTING PRINTER PORT BAUD RATESt@P IActionVerify 8Ensure printer speed coincides with selected printer port speed. If speeds do not coincide, either change printer speed, or repeat Steps 8 and 9, selecting a printer port speed which coincides with the selected speed of the printer. Press 6 (QUIT softkey) to return to Maintenance menu.Test completed. Page 13
SECTION MITL9109-094-320-NASuspending Printer Device 2.09 The print device may be suspended from printing either by specifying its PLID or its port along with the SUSPEND-PRTR command. CHART 2-7 SYSTEM LEVEL: SUSPEND-PRTR COMMAND StepActionVerify 1Access MAINTENANCESystem responds by displaying Maintenance menu. application. 2Press 1 (SYSTEM softkey).Softkey prompts change. System Level is accessed. 3Press 5 (SUSPEND-PRTRCommand line responds with: softkey). SUSPEND PRTSand softkey prompts change. 4Press 7 (PRINTER-PLIDCommand line responds with: softkey). SUSPEND-PRTR PRINTER-PLIDBAY/SLOT/CIRCUIT EXT-NUM CANCEL 5Select BAY/SLOT/CCT orSystem prompts for plid or extension number, EXT-NUM softkey prompts change. 6Press 0 (ENTER softkey).Command line clears, and softkey prompts return to System Level format. 7Press 6 (QUIT softkey) to return to Maintenance menu. ALTERNATIVELY 4Press 8 (PRINTER-PORTCommand line responds with: softkey)SUSPEND-PRTR PRINTER-PORT and softkeys CANCEL and ENTER 5Press 5 (CANCEL softkey)or 0 (ENTER softkey). 6Press 6 (QUIT softkey) to return to Maintenance menu. Page 14
System Test ProceduresResume Print Device2.10 The print device may be commanded to resume printing by specifying either its PLID or its port and the RESUME-PRTR command. CHART 2-8 SYSTEM LEVEL: RESUME-PRTR COMMAND StepActionVerify 1Access MAINTENANCESystem responds by displaying Maintenance menu. application. 2Press 1 (SYSTEM softkey).Softkey prompts change. System level is accessed. 3Press 7 (RESUME-PRTRCommand line responds with: softkey). RESUME-PRTRand softkey prompts change. 4Press 7 (PRINTER-PLIDCommand line responds with: softkey). RESUME-PRTR PRINTER-PLIDBAY/SLOT/CIRCUIT EXT-NUM CANCEL 5Select BAY/SLOT/CCT orSystem prompts for plid or extension number. EXT-NUM Softkey prompts change to CANCEL and ENTER. 6Press 0 (ENTER softkey)Command line clears and softkey prompts return to System Level format. 7Press 6 (QUIT softkey) to return to Maintenance menu. ALTERNATIVELY 4Press 8 (PRINTER-PORTCommand line responds with: softkey)RESUME-PRTR PRINTER-PORT and softkeys CANCEL and ENTER 5PRESS 5 (CANCEL softkey)or 0 (ENTER softkey). 6Press 6 (QUIT softkey) to return to Maintenance menu. Page 15