    Have a look at the manual Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 618
    							‘: :::... . .  .
    Step
    1
    2
    3
    -~~~
    otccess MAINTENANCE
    spplication.
    Press 1[SYSTEM softkey).
    Press 1 (SET softkey).
    4Press 2 (TIME softkey).
    5
    6Enter time in either
    12- or 24-hour format.
    Press 0 (ENTER softkey).
    7
    8Repeat Step 3 through
    Step 5.
    Press 1 (PM softkey).
    9Press 0 (ENTER softkey).Setting System Time
    2.05System time may be set from the Maintenance Terminal. The
    new time will be reflected on the Maintenance Terminal display,
    the Attendant Console LCD display, and the 
    SUPERSET 4 telephone
    LCC display. Chart 2-3 shows the steps for testing setting of system
    time.
    CHART 2-3
    SETTING SYSTEM TIME
    ActionVerify
    System responds by displaying Maintenance menu.
    Softkey prompts change. System Level is accessed.
    Command line responds with:
    SETand 
    softkey prompts change.
    Command line responds with:
    SET TIME enter Time HH:MM
    snd softkeys are disabled.
    Command line shows digits entered,
    and PM, ENTER and CANCEL 
    softkeys are enabled.
    Command line clears, and new time is displayed. 
    Softkeyprompts return to system level functions.
    Command line shows digits entered, and PM, ENTER and
    CANCEL 
    softkeys are enabled.
    Command line shows:
    SET TIME 
    xX:xX PM
    and ENTER and CANCEL 
    softkeys are enabled.
    New time is displayed. 
    Softkey prompts change, returning
    to system level format. Test completed. 
    						
    							System Test Procedures: .>;;.:Setting System Time
    2.05System time may be set from the Maintenance Terminal. The
    new time will be reflected on the Maintenance Terminal display,
    the Attendant Console LCD display, and the 
    SUPERSET 4 telephone
    LCL’ display. Chart 2-3 shows the steps for testing setting of system
    time.
    CHART 2-3
    SETTING SYSTEM TIME
    StepActionVerify
    1Access MAINTENANCESystem responds by displaying Maintenance menu.
    application.
    2Press 1Softkey prompts change. System Level is accessed.
    (SYSTEM softkey).
    3Press 1 (SET softkey).Command line responds with:
    SETand 
    softkey prompts change.
    4Press 2 (TIME softkey).Command line responds with:
    SET TIME enter Time HH:MM
    and 
    softkeys are disabled.
    5Enter time in eitherCommand line shows digits entered,
    12- or 24-hour format.and PM, ENTER and CANCEL softkeys are enabled.
    6Press 0 (ENTER softkey).Command line clears, and new time is displayed. Softkeyprompts return to system level functions.
    7Repeat Step 3 throughCommand line shows digits entered, and PM, ENTER and
    Step 5.CANCEL 
    softkeys are enabled.
    8Press 1 (PM softkey).Command line shows:
    SET TIME 
    xX:xX PM
    and ENTER and CANCEL 
    softkeys are enabled.
    9Press 0 (ENTER softkey).New time is displayed. Softkey prompts change, returning
    to system level format. Test completed.
    Page 7 
    						
    							SECTION MITLSI 09-094-320-NAChanging Passwords
    2.06Passwords may be changed by a user for his or her access
    level, and all lower access levels. At the INSTALLER access
    level, all passwords may be changed. Chart 2-4 shows the steps for
    testing changing passwords at the INSTALLER level. If a different ac-
    cess level is chosen, only those levels equal to or below the chosen
    level will be available for testing setting of passwords.
    CHART 2-4
    CHANGING PASSWORDS
    StepActionVerify
    1Access MAINTENANCESystem responds by displaying Maintenance menu.
    application.
    2Press 1Softkey prompts change. System Level is accessed.
    (SYSTEM softkey).
    3Press 1 (SET softkey).Command line responds with:
    SETand 
    softkey prompts change.
    4Press 3 (PASSWORDCommand line responds with:
    softkey).’
    SET PASSWORDand 
    softkey prompts change.
    5Press 7 (INSTALLERCommand line responds with:
    softkey).
    SET PASSWORD INSTALLERand 
    softkey prompts clear except for CANCEL and ENTER.
    6Press 0 (ENTER softkey).Command line responds with:
    Enter Old Password then press RETURN/ENTER:
    and no 
    softkey prompts are displayed.
    Page 8 
    						
    							System Test Procedures;tep IActionCHART 2-4 (CONT’D)
    CHANGING PASSWORDSIVerifv
    7
    10
    11
    Enter Installer levelPassword is not displayed.
    password and pressCommand line responds with:
    RETURN.Enter New Password then press RETURN/ENTER:
    Enter new Installer
    password and press
    RETURN.
    Enter new Installer
    password again and press
    RETURN.
    Repeat Steps 3 through 9NOTE: When setting passwords for a lower level than the
    for remaining levels ofcurrent level of access, the prompt “Enter old Password
    access (SUPERVISOR,
    MAINTl, MAINT2,
    then press RETURN:” (as in step 6) will not appear. Instead
    ATTENDANT).the prompt to enter new password (as in step 7) appears
    immediately.IPress 6 (QUIT 
    softkey)~
     to return to Maintenancemenu.
    Test completed.if old password was correctly entered
    or:
    An invalid or incorrect password was entered
    if old password was incorrectly entered.If old password was correctly entered go to Step 8; if
    incorrectly entered, press 5 (CANCEL softkey) and go to
    Step 7.
    Password is not displayed. Command
    line responds with:
    Enter New Password to verify then press RETURN:
    Password is not displayed. Command
    line clears and 
    softkey prompts
    change to System Level format if password is verified. If
    password fails to verify, command line responds
    with:
    An invalid or incorrect password was entered.
    If password fails to verify, press 5 (CANCEL 
    softkey) andgo to Step 7.
    Page 9 
    						
    							SECTION MITL9109-094-320-NASetting Maintenance Terminal Port Baud Rate
    2.07 The baud rate of the Maintenance Terminal port may be
    changed from the value set at the time of 
    login. Any one of six
    baud rates may be chosen: 300, 600, 1200, 2400, 4800 or 9600 baud.
    Note that this operation changes the baud rate of 
    ,the Maintenance
    Terminal port only; the baud rate of the terminal itself must be
    changed separately. Chart 2-5 shows the steps for testing changing of
    the Maintenance Terminal port baud rate.
    CHART 2-5
    SETTING MAINTENANCE TERMINAL PORT BAUD RATE
    StepActionVerify
    1Access MAINTENANCESystem responds by displaying Maintenance menu.
    application.
    2Press 1 (SYSTEM softkey).Softkey prompts change. System Level is accessed.
    3Press 1 (SET softkey).Command line responds with:
    SETand 
    softkey prompts change.
    4Press 4 (SPEED softkey).Command line responds with:
    SET SPEEDand 
    softkey prompts change.
    5Press 1 (MAINT-PORTCommand line responds with:
    softkey).SET SPEED MAINT-PORT enter Speed then press RETURN:
    baud rates and CANCEL 
    softkey prompts are displayed.
    6Press the softkey with theCommand line responds with:
    corresponding baud rateSET SPEED 
    MAINT PORT =-BPS and CANCEL and
    ENTER 
    softkeys are displayed
    7Press 0 (ENTER softkey).Command line responds with:
    Change terminal speed and press RETURN when ready.
    Page 10 
    						
    							System Test Procedures
    CHART 2-5 (CONT’D)
    SETTING MAINTENANCE TERMINAL PORT BAUD RATE
    StepActionVerify8Check to ensure terminal
    speed is the same value as
    the maintenance port; if
    different, change terminal
    speed to coincide with
    selected Maintenance Port
    value.
    9Press RETURN.Command line clears and softkey prompts return to
    System Level format.
    10Press 6 (QUIT softkey) toTest completed.
    return to Maintenance
    menu.
    Page 11 
    						
    							SECTION MITL9109-094-320-NASetting Printer Port Baud Rate
    2.08 The baud rate of the Printer Port may be changed from its
    default value of 1200 baud. Any one of six baud rates may be
    chosen: 300, 600, 1200, 2400, 4800 or 9600 baud. Note that this opera-
    tion changes the baud rate of the Printer Port only; the 
    b,3ud rate of
    the printer itself must be changed separately. Chart 2-6 shows the
    steps for testing changing of the Printer Port baud rate.
    CHART 2-6
    SETTING PRINTER PORT BAUD RATE
    StepActionVerify
    1Access MAINTENANCESystem responds by displaying Maintenance menu.
    application.
    2Press 1 (SYSTEM softkey).Softkey prompts change. System Level is accessed.
    3Press 1 (SET softkey).Command line responds with:
    SETand 
    softkey prompts change.
    4Press 4 (SPEED softkey).Command line responds with:
    SET SPEEDand 
    softkey prompts change.
    5Press 8 (PRINTER-PORTCommand line responds with:
    softkey).SET SPEED PRINTER-PORT enter Speed then press
    RETURN:and no 
    softkey prompts are displayed.
    6Press the softkey with theCommand line responds with:
    corresponding baud rate.SET SPEED PRINTER-PORT 
    XXXX-BPS and CANCEL and
    ENTER 
    softkeys are displayed.
    Page 12 
    						
    							System Test Procedures
    CHART 2-6 (CONT’D)
    SETTING PRINTER PORT BAUD RATESt@P IActionVerify
    8Ensure printer speed
    coincides with selected
    printer port speed. If
    speeds do not coincide,
    either change printer
    speed, or repeat Steps 8
    and 9, selecting a printer
    port speed which coincides
    with the selected speed of
    the printer.
    Press 6 (QUIT softkey) to
    return to Maintenance
    menu.Test completed.
    Page 13 
    						
    							SECTION MITL9109-094-320-NASuspending Printer Device
    2.09 The print device may be suspended from printing either by
    specifying its 
    PLID or its port along with the SUSPEND-PRTR
    command.
    CHART 2-7
    SYSTEM LEVEL: SUSPEND-PRTR COMMAND
    StepActionVerify
    1Access MAINTENANCESystem responds by displaying Maintenance menu.
    application.
    2Press 1 (SYSTEM softkey).Softkey prompts change. System Level is accessed.
    3Press 5 (SUSPEND-PRTRCommand line responds with:
    softkey).
    SUSPEND PRTSand 
    softkey prompts change.
    4Press 7 (PRINTER-PLIDCommand line responds with:
    softkey).
    SUSPEND-PRTR PRINTER-PLIDBAY/SLOT/CIRCUIT EXT-NUM CANCEL
    5Select BAY/SLOT/CCT orSystem prompts for plid or extension number,
    EXT-NUM
    softkey prompts change.
    6Press 0 (ENTER softkey).Command line clears, and softkey prompts return to
    System Level format.
    7Press 6 (QUIT softkey) to
    return to Maintenance
    menu.
    ALTERNATIVELY
    4Press 8 (PRINTER-PORTCommand line responds with:
    softkey)SUSPEND-PRTR PRINTER-PORT and softkeys CANCEL and
    ENTER
    5Press 5 (CANCEL softkey)or 0 (ENTER softkey).
    6Press 6 (QUIT softkey) to
    return to Maintenance
    menu.
    Page 14 
    						
    							System Test ProceduresResume Print Device2.10 The print device may be commanded to resume printing by
    specifying either its 
    PLID or its port and the RESUME-PRTR
    command.
    CHART 2-8
    SYSTEM LEVEL: RESUME-PRTR COMMAND
    StepActionVerify
    1Access MAINTENANCESystem responds by displaying Maintenance menu.
    application.
    2Press 1 (SYSTEM softkey).Softkey prompts change. System level is accessed.
    3Press 7 (RESUME-PRTRCommand line responds with:
    softkey).
    RESUME-PRTRand 
    softkey prompts change.
    4Press 7 (PRINTER-PLIDCommand line responds with:
    softkey).
    RESUME-PRTR PRINTER-PLIDBAY/SLOT/CIRCUIT EXT-NUM CANCEL
    5Select BAY/SLOT/CCT orSystem prompts for plid or extension number.
    EXT-NUM
    Softkey prompts change to CANCEL and ENTER.
    6Press 0 (ENTER softkey)Command line clears and softkey prompts return to
    System Level format.
    7Press 6 (QUIT softkey) to
    return to Maintenance
    menu.
    ALTERNATIVELY
    4Press 8 (PRINTER-PORTCommand line responds with:
    softkey)RESUME-PRTR PRINTER-PORT and softkeys CANCEL and
    ENTER
    5PRESS 5 (CANCEL softkey)or 0 (ENTER softkey).
    6Press 6 (QUIT softkey) to
    return to Maintenance
    menu.