    Have a look at the manual Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 618
    							Installation Forms
    TABLE5-11(CONT’D)
    ANALOG BAY 5 PLUG ASSIGNMENTSPLUG PI0 (at Cross-Connect Field)Bay/
    Slot
    5-7
    5-8
    5-9
    5-10
    5-l 1
    5-12
    PairConnection/Comments
    cctPinColour(Extension Circuit Feature)
    26VI-BL1BL-W27w-o2o-w28W-G3G-W29W-BR4BR-W
    30w-s
    :Is-w
    R-BL:2BL-R
    R-O
    ;3O-R
    R-G8G-R
    34R-BR9BR-R35R-S
    :iS-R
    BK-BL11BL-BK37BK-0120-BK
    38BK-G
    iiG-BK
    BK-BR14BR-BK
    40BK-S
    15S-BK41Y-BL16BL-Y
    42Y-O
    17O-Y
    43Y-G
    18G-Y
    44Y-BR
    19BR-Y
    45Y-S
    20S-Y
    46V-BL
    21BL-V
    4:v-o
    o-v
    48V-G
    23G-V
    49V-BR
    24BR-V
    50v-sSPARE
    25S-VSPAREPage 145 
    						
    							SECTION MITL9109-094-206-NATABLE 5-12
    PERIPHERAL CABINET POWER FAIL TRANSFER CARD ASSIGNMENTS
    PLUG 
    P20 (Power Fail Connections to to Cross-Connect Field)
    PairLeadConnection/CommentsPinColourDesignation
    (Extension Circuit Feature)
    26W-BLSTATION Tl
    :7BL-WSTATION RI
    w-oLINE CARD Tl
    ;8o-wLINE CARD RI
    W-GTRUNK Tl3G-WTRUNK RI29W-BRTRUNK CARD Tl4BR-WTRUNK CARD RI
    30w-sSTATION T2
    51s-wSTATION R2
    R-BLLINE CARD T2
    :2BL-RLINE CARD R2
    R-OTRUNK T2
    s3O-R.TRUNK R2
    TRUNK CARD T2
    82:;TRUNK CARD R2
    34R-BRSTATION T39BR-RSTATION R335R-SLINE CARD T3
    iiS-RLINE CARD R3
    BK-BLTRUNK T311BL-BKTRUNK R337BK-0TRUNK CARD T3120-BKTRUNK CARD R3
    38BK-GSTATION T4
    :iG-BKSTATION R4
    BK-BRLINE CARD T414BR-BKLINE CARD R440BK-STRUNK T415S-BKTRUNK R441Y-BLTRUNK CARD T416BL-YTRUNK CARD R4
    42Y-OSTATION T517O-YSTATION R543Y-GLINE CARD T518G-YLINE CARD R544Y-BRTRUNK T519BR-YTRUNK R545Y-STRUNK CARD T520S-YTRUNK CARD R5
    46V-BLSTATION T621BL-VSTATION R6
    4;v-oLINE CARD T6
    o-vLINE CARD T648V-GTRUNK T623G-VTRUNK R649V-BRTRUNK CARD T624BR-VTRUNK CARD R6
    s-vSPARE
    v-s
    SPAREPage 146 
    						
    							Installation Forms
    TABLE 5-12 (CONT’D)
    PERIPHERAL CABINET POWER FAIL TRANSFER CARD ASSIGNMENTSPLUG P21 (Power Fail Connections to to Cross-Connect Field)
    Pin
    26
    :72
    28
    3
    29
    4
    30
    5
    31
    i2
    .;38
    34
    9
    35
    ::11
    37
    12
    38
    ii14
    40
    15
    41
    16
    42
    1743
    18
    44
    19
    45
    2046
    21
    47
    2248
    2349
    24
    50
    25
    PairLead
    ColourDesignation
    W-BLSTATION 
    TlBL-WSTATION RI
    w-oLINE CARD 
    Tlo-wLINE CARD RI
    W-GTRUNK 
    TlG-WTRUNK RI
    W-BRTRUNK CARD 
    TlBR-WTRUNK CARD RI
    w-sSTATION 
    12s-wSTATION R2
    R-ELLINE CARD T2
    BL-RLINE CARD R2
    R-OTRUNK T2
    O-RTRUNK R2
    R-GTRUNK CARD T2
    G-RTRUNK CARD R2
    R-BRSTATION T3
    BR-RSTATION R3
    R-SLINE CARD T3
    S-RLINE CARD R3
    BK-BLTRUNK T3
    BL-BKTRUNK R3
    BK-0TRUNK CARD T3
    0-BKTRUNK CARD R3
    BK-GSTATION T4
    G-BKSTATION R4
    BK-BRLINE CARD T4
    BR-BKLINE CARD R4
    BK-STRUNK T4
    S-BKTRUNK R4
    Y-ELTRUNK CARD T4
    BL-YTRUNK CARD R4
    Y-OSTATION T5
    O-YSTATION R5
    Y-GLINE CARD T5
    G-YLINE CARD R5
    Y-BRTRUNK T5
    BR-YTRUNK R5
    Y-STRUNK CARD T5
    S-YTRUNK CARD R5
    V-BLSTATION T6
    BL-VSTATION R6
    v-oLINE CARD T6
    o-vLINE CARD T6
    V-GTRUNK 
    T8G-VTRUNK R6
    V-BRTRUNK CARD T6
    BR-VTRUNK CARD R6
    s-v
    SPAREv-sSPAREConnection/Comments
    (Extension Circuit Feature)
    Page 147 
    						
    							MITEL STANDARD PRACTICESECTION MITL9109-094-210-NAIssue 1, April 1988
    SX-200” DIGITAL
    PRIVATE AUTOMATIC BRANCH EXCHANGE (PABX)
    CUSTOMER DATA ENTRY (CDE)
    @Copyright 1988, MITEL Corporation. All rights resewed.
    T”Trademark of MITEL Corporation
    @Registered Trademark of MITEL Corporation 
    						
    							9ECTION MITL9109-094-210-NANOTICE .
    The information contained in this document is believed to be accurate in all
    not warranted by 
    Mite1 Corporation (MITEL). The information is subject to change without
    notice and should not be construed in any way as a commitment by 
    Mite1 or any of its
    affiliates or subsidiaries. 
    Mite1 and its affiliates and subsidiaries assume no responsibility
    for any errors or omissions in this document. Revisions of this document or new editions of
    it may be issued to incorporate such changes. 
    						
    							Customer Data Entry (CDE)
    CONTENTS
    PAGE
    1. INTRODUCTION
    General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
    Reason for Issue . . . . . . . . . . . . . . . V . m . . . . . . ~ . m . m . . . . . . . . . 1
    2. EQUIPMENT USED FOR CUSTOMER DATA ENTRYGeneral.............................................3
    Attendant Console.....................................
    3
    ASCII CRT Terminal....................................
    3
    Form Editing.........................................
    3
    Levels of Access to Customer Data Entry....................
    43. CDE PACKAGE GROUPING
    General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
    4. OPERATION
    Loading of System Software.............................7
    Customer Data Entry Access from a terminal.................
    7
    Customer Data Entry Access from the Attendant Console........
    8
    Exit from CDE.......................................
    10Form 01 
    -System Configuration.........................11Form 02 
    -Feature Access Codes.........................17Form 03 
    -COS Define.................................20Form 04 
    -System Options/System Timers..................28
    Form 05
    - Tenant Interconnection Table....................32Form 06 
    -Tenant Night Switching Control..................34Form 07 
    -Console Assignments.........................36Form 08 
    - Console LDN Assignments......................39Form 09 
    -StationsKlJPERSET Telephones..................42
    SUPERSET Telephone Lines.............................45
    Review List for Form 09................................
    50Form 10 
    -Pickup Groups...............................52Form 11 
    -Data Circuit Descriptor........................54
    Data Circuit Descriptor Options..........................
    56
    Data Circuit Descriptor Parameters........................
    58
    Review List for Form 11................................
    65Form 12 
    -Data Assignment.............................67
    Form 13 
    - Trunk Circuit Descriptors.......................71
    Options for Trunk Circuit Descriptors......................75
    Review List for Form 13................................
    80Form 14 
    -Non-Dial-In Trunks...........................82Form 15 
    -Dial-In Trunks...............................85Form 16 
    - Trunk Groups
    ...............................88Form 17 
    -Hunt Groups................................90Form 18 
    -Miscellaneous System Ports....................94Form 19 
    -Call Rerouting Table..........................98Form 20 
    - ARS: COR Group Definition....................101Form 21 
    -ARS: Day Zone Definition......................103Form 22 
    - ARS: Modified Digit Table.....................105Form 23 
    - ARS: Route Definition........................107Form 24 
    - ARS: Route Lists
    ............................109
    . . .III 
    						
    							SECTION MITL9109-094-210-NACONTENTS (CONT’D)
    PAGEForm 25 
    - ARS: Route Plans............................111
    Form 26- ARS: Digit Strings...........................113
    ARS: Nested Digit Strings..............................
    115
    Form 27
    - ARS: Maximum Dialed Digits...................118Form 28 
    -Form Access Restriction Definition..............‘120
    Form 29- DTE Profile................................123
    Options For Form 29.................................125
    Review List for Form 29................................128Form 30 
    -Device Interconnection Table...................130
    Review List for Form 30...............................
    132
    Form 31
    - System Abbreviated Dial Entry..................134
    Form 32
    - Customer Data Print.........................136
    Form 33
    - Account Code Entry.........................140Form 34 
    -Directed IO................................143
    Form 35 
    - Global Find Access Code......................147Form 36 
    -Modem Assignment..........................149
    Form 37
    - Guest Room SUPERSET Keys Template...........152Form 38 
    -ACD Keys Template..........................154
    Form 39
    - ACD Agent Groups..........................156
    ACD Group Options For Form 39........................
    158
    Form 40
    - ACD Supervisors............................160
    Expand Sub-form for Form 40..........................
    162
    Form 41
    - ACD Path.................................164Form 42 
    -Tl Link Descriptors..........................168
    Link Descriptor Options for Form 42......................
    170Alarm 
    Debounce Timer..............................171
    B8ZS Zero Code Suppression.........................171
    Slip Rate Limits...................................171
    BER Limits.......................................171
    Framing Loss Limits................................172
    Limit Definitions...................................
    172
    RTS Timer 
    - Service Limit Exceeded....................172RTS Timer 
    -Net Slip Limit Exceeded...................172RTS Timer 
    - After Alarm.............................172
    Review List for Form 42...............................
    173Form 43 
    - T’l Link Assignment..........................174
    Form 44
    - Tl Network Sync............................1765. PROGRAMMING ERROR MESSAGES
    General 
    ,.......................................... 179
    LIST OF TABLES
    TABLETITLEPAGE
    4-l
    List of Customer Data Entry Forms................94-2
    Available Forms..............................104-3
    Form 01- System Configuration.................114-4Form 02 
    -Feature Access Codes................174-5
    Programmable Feature Access Codes.............194-6Form 03 
    - COS Define.........................20