Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual
Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual
Have a look at the manual Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
installation Forms TABLE 4-2 TRUNK CARD SWITCH SETTINGS - E&M/TIE TRUNK CARD BAV NUMBERBAV NUMBER SLOT NUMBERSLOT NUMBER CIRCUIT NUMBERCIRCUIT NUMBER LOOP CONDITION LOOP CONDITION NOT STOP DIAL NOT STOPDIAL NOTE: TRUNK CARD SWITCHES MUST BE SET TO ONE OF THE TWO POSSIBLE SETTINGS FOR EACH SWITCH AS DETAILED IN SECTION MITLglOB-095~ZOO-NA, SHIPPING, RECEIVING AND INSTALLATION INFORMATION. FRM0129RlPage 95
SECTION MITLSI 09-094-206-NATRUNK CONTROL SWITCHES /OPEN OUTGOING WINK2-WIRESPECIAL GAIN (NOTE 3)NORMAL SETTING 1 = CLOSED 10 = NOT USED LI”’INOT OUTGOINGNOT4-WIRE ‘NGllNGNORMAL WINKGAIN 600 S-2 Ir--l TRUNK 1I, IMPEDANCEIl SWITCHESLj (NOTE 1)9i53-6P-WIREPN103026 TRUNK CONTROL SWITCHES 60052 r--‘TRUNK 2 ‘IMPEDANCE kWiTt3iES-J(NOTE 1)9ool-i P-WIRE r-7 I I 16OOi-iL ’x11 4-WiR
Installation Forms NOTES FOR FIGURE 4-2 E&M/TIE TRUNK CARD SWITCH FUNCTIONSNotes: 1. Trunk impedance switches are located on the rear face of the Trunk Card. 2. Outgoing/incoming switch settings: OutgoingIncomingBusy SwitchBusy Switch ResultSet toSet to IdleBusyNormal trunk operation - if trunk is made busy by attendant, outgoing busy, incoming busy condition results. See below. BusyBusy /-G-+4- Trunk cannot be seized, incoming or outgoingfrom the ACD system. Recommended setting if trunk is not connected to trunk circuit. Outgoing calls receive busy tone. Incoming calls receive ringing tone but cannot be answered. Trunk is made busy by attendant, outgoing busy, incoming idle condition results. See below. The Incoming busy switch, when operated, will provide an outgoing seize signal when-ever the trunk is made outgoing busy (either from the outgoing busy switch on the trunk, or from the console).3. Normal gain provides 0.5 dB insertion loss through the ACD. Special gain provides for 4-wire operation with carrier systems requiring signal levels of +7 dB on the Rx pair, and -16 dB on the TX pair. Page 97
SECTION MITL9109-094-206-NATABLE 4-3 TRbNK CARD SWITCH SETTINGS - DID/TIE TRUNK CARD TRUNK 1 TRUNK 2 BAV NUMBER SLOT NUMBER CIRCUIT NUMBER TRUNK NUMBER (l-200) SWITCH “B” SETTING SWITCHES (3) NOT STOP DIALTRUNK 1 TRUNK 2 BAV NUMBER SLOT NUMBER CIRCUIT NUMBER TRUNK NUMBER (l-200) SWITCHES (3)NOT STOP DIAL NOTE: TRUNK CARD SWITCHES MUST BE SET TO ONE POSSIBLE SETTING FOR EACH SWITCH AS DETAILED IN SECTION MITLglOB-095-ZOO-NA. SHIPPING, RECEIVING AND INSTALlATION INFORMATION. FRM012BR2Page 98
Installation Forms TRUNK CONTROL SWITCHES TABLE NORMAL SETTING,- OPEN .-\SEE TABLE 5=CLOSED6=CLOSED7=CLOSED8=CLOSED9 = NOT USED 10 = NOT USED OUTG;;NG lNC~,OM;NG SWITCHSWgTCHIIA--- NOTNOT OUTGOING INCOMING WINKWINK SW11 Ir---7i-L:6OJQ :---:soon9oofzL---dSW3$$tyTRUNK 19ooclIMPEDANCE SWITCHES 8TRUNK BUSV SWITCHES 1 6OOcl7:sw1; I I I----- sz p;-< 9000L?-! 6009OOQ SW3yq!~1 I I SW21I ; TRUNK 2!.LJIMPEDANCE9oow SWITCHESI’ (TRUNK BUSY SWITCHES. PULSING Id--/ TRUNK 2 L1 PULSINGNORMAL SETTING 1=CLOSED 2=CLOSED 3=CLOSED4 =CLOSED5=OPEN 6=OPEN 7=CLOSED8=CLOSED S496ElRlFigure 4-3 DID/Tie Trunk Card Switch Functions Page 99
SECTION MITL9109-094-206-NANOTES FOR FIGURE 4-3 DID/TIE TRUNK CARD SWITCH FUNCTIONS Notes: 1. Trunk impedance switches are located on the rear face of the Trunk Card.Trunk Busy Switches 2.Outgoing Busy Switches (I per trunk) can be set for either of the following conditions: Idle setting - normal trunk operation Busy setting - trunk cannot be seized for outgoing call3. The “outgoing busy” condition may be set either by the outgoing busy switch (Note 2),or by the console “Trunk Busy Out” function. When this condition is in effect the incoming Busy Switch affects the trunk condition as follows: Idle setting - no answer will be given to incoming trunk calls Busy setting - a permanent seizure condition is given towards the trunk.TABLE 4-4 E&M TRUNK MODULE SWITCH SETTINGS FunctionSwitch Positions 12345678 Digital PABX to Line Gain (3 dB)oxxxxxxx Digital PABX to Line Gain (-13 dB)1 xx.xxxxxLine to Digital PABX Gain (-4 dB)Line to Digital PABX Gain (-11 dB)xoxxxxxx xlxxxxxxI 600 Ohm Termination Complex Termination 2-Wire Transmission 4-Wire Transmissionxx10xxxx xx01xxxxxxxxlxxx xxxxoxxx Type 1 Signaling Type 5 Signalingxxxxxlxx xxxxxoxx Note: 0 = Open, 1= Closed and x = Not ApplicablePage 100
5. CABLING AND CROSS-CONNECTIONSGeneral 5.01The forms contained in this Part show the plug assignments foreach circuit of each bay. The first four forms cover the four bcys in the all-digital variant. Plug assignment forms are also included for analog Bay 3 and Peripheral Cabinet, if needed. Power Fail Transfercard assignment forms are included for both Control and Peripheral cabinets. For more information,refer to Section MITLS 109-094- 200-NA, Shipping, Receiving and Installation Information. Page 101
SECTION MITL9109-094-206-NATABLE 5-l BAY 1 PLUG ASSIGNMENTS PLUG J7 (at Cross-Connect Field)Bay/ PairConnection/Comments Slot cctPinColour(Extension Circuit Feature) l-2 26W-BL:7BL-W w-o 2o-w28W-G3G-W 29W-BR4BR-W30W-S51s-w R-BL 6BL-R 32R-O z3O-R R-G8G-R34R-BR9BR-R 35R-S10S-R36BK-BL11BL-BK 37BK-0 120-BK 38BK-GNot Used13G-BK l-l 39BK-BR14BR-BK 40BK-S 15S-BK41Y-BL16BL-Y 42Y-O 17O-Y43Y-G18G-Y 44Y-BR 19BR-Y 45Y-S 20S-Y4:V-BL BL-V 47v-o 22o-v 48V-G 23G-V 49V-BR E;tBR-V v-s25s-v Page 102
Installation Forms TABLE 5-l (CONT’D) BAY 1 PLUG ASSIGNMENTSPLUG Jll (at Cross-Connect Field)Bay/ Slot l-4 l-3 PairConnection/Comments CctPinColour(Extension Circuit Feature) 26W-BL :7BL-W w-o $8o-w W-G3G-W 29W-BR4BR-W30w-s5S-W R-BL 6BL-R 32R-O i3O-R R-G8G-R34R-BR9BR-R 35R-S iiiS-R BK-BL11BL-BK37BK-0120-BK 38BK-GNot Used13G-BK 39 BK-BR14BR-BK 40BK-S 15S-BK41Y-BL16BL-Y 42Y-O 17O-Y 43Y-G 18G-Y 44Y-BR 19BR-Y 45Y-S 20S-Y 46V-BL 21BL-V 47v-o 22o-v 48V-G 23G-V 49V-BR 24BR-V50v-s25s-v Page 103
SECTION MITL9109-094-206-NATABLE 5-l (CONT’D) BAY 1 PLUG ASSIGNMENTS PLUG(atCross-Connect Bay/Slot l-6 l-5PairConnection/Comments CctPinColour(Extension Circuit Feature) 26W-BL:7BL-W w-o 2o-w28W-G3G-W 29W-BR4BR-W30w-s51s-w R-BL 6BL-R 32R-O z3O-R8;I; 34R-BR9BR-R 35R-S iiS-R BK-BL ;:BL-BK BK-0120-BK 38BK-GNot Used13G-BK 39BK-BR14BR-BK 40BK-S 15S-BK41Y-BL16BL-Y 42Y-O 17O-Y43Y-G18G-Y44Y-BR19BR-Y 45Y-S 20S-Y ;:V-BL BL-V 47v-o 22o-v 48V-G 23G-V49V-BR f ;tBR-V v-s25s-v Page 104