Have a look at the manual Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Customer Data Entry (CDE)Dataset. Because the DATASET 1102 is a dual DATASET, a second line appears for subcircuit 2 of the port. 3-DSI 102 CCTP:This softkey appears after the DATA DEV TYPE softkey has been pressed on the second line of a port assigned as a DATASET 1102. It is the only softkey available in this situation. Press- ing the DS1102 CCT2 softkey assigns the device type for subcircuit 2 of the port as an Asynchronous Rack Mount Dataset. 4-DSllOl: This softkey appears after the DATA DEV TYPE softkey has been pressed. Pressing this softkey assigns the device type as a data cartridge. 7-DS2102: This softkey appears after the DATA DEV TYPE softkey has been pressed. Pressing this softkey assigns the device type as an Asynchronous/Synchronous Rack Mount DATASET.8-DS2103: This softkey appears after the DATA DEV TYPE softkey has been pressed. Pressing this softkey assigns the device type as an Asynchronous/Synchronous Rack Mount DATASET. 9-DSCONS: This softkey appears after the DATA DEV TYPE softkeyhas been pressed. Pressing this softkey assigns the device type as a Mk 2 Console printer port. P-FIND EXT: Pressing the FIND EXT softkey displays the ENTER EX- TENSION NUM prompt. When a valid extension number of a DATASETis entered, its physical location is displayed on the command line. 3-FIND AVL:Pressing this softkey prompts the user to enter an extension number. When a valid extension number of an associated voice set is entered, and the ENTER softkey is pressed, the physical location of the DATASET which is associated with the selected voice set is displayed on the command line. 5-RANGE: This softkey facilitates block programming of data devices. Pressing this softkey displays FROM BAY; SLOT: and CIRCUIT: TO BAY: SLOT: CIRCUIT: prompts on the command line. The range of devices is then specified by entering valid bay, slot and circuit numbers for the first and last devices. The entry is completed by pressing the ENTER softkey. When the extension number for the first device is entered, the system automatically assigns incremented extension numbers, the same COS, COR, CDN, and DTE for each device in the block. A dual circuit DATASET cannot be included in range programming. 6-QUIT: Pressing this softkey returns the display to the level before DATASET DEV TYPE was selected. 7-BAY/SLT/CCT: When this softkey is pressed the command line displays: BAY: SLOT: CIRCUIT: prompts. Once the location is specified, and the softkey ENTER is pressed, the command line updates with information about the device and the cursor moves to the TYP field. If an invalid number is entered the system inhibits subsequent cursor movement. Page 69
SECTION MITL9109-094~Zl O-NA8-DELETE: This softkey appears when the cursor is positioned at data on the command line. Pressing the DELETE softkey removes the entry from the form. The deletion is completed by pressing the softkey: ENTER.O-DELETE FIELD: This softkey appears when the cursor is positioned in the AVL or HOTLINE field, when a value has been already pro- grammed. Pressing the DELETE FIELD softkey removes the value which is programmed in that field. The deletion is completed by pressing the ENTER softkey.O-ENTER: This softkey appears after data has been modified. Pressing the ENTER softkey commits each modification one at a time to the database.Page 70
Customer Data Entry (CDE) Form 13 - Trunk Circuit Descriptors 4.60Trunk circuit descriptors are similar to Classes of Service. A trunk circuit descriptor specifies the hardware options for eachtype of Trunk Card. Refer to Table 4-23, Trunk Circuit Descriptors for the form layout. Trunk circuit descriptors are complemented by the switch settings on the SX-200 type Trunk Cards. Refer to the Trunk Card Switch Assignments Forms in Part Number 9109-094-206-NA, Installation Forms. There are 12 Trunk Card types and are as follows:4-Circuit CO6-Circuit DID 6-Circuit COE&M Trunk4-Circuit DISAE&M Trunk DISA6-Circuit DISAE&M Trunk Module DISA2-Circuit DID/TIE2 Circuit TIE DISA EM MOD DISATl Trunk Each Trunk Card type has its own set of parameters as detailed in Table 4-25, Trunk Hardware Options. The system supports a maximum of 25 trunk circuit descriptors.TABLE 4-23 FORM 13 - TRUNK CIRCUIT DESCRIPTORS CDE TERMINAL DISPLAY 12:Ol AM 15-JAN-88alarm status = NO ALARM DESCR I PTORTRLhlK TYPENlblBER OF TRKS ASSIGNEDcoMlENTs 014-CIRCUIT CO0 024-CIRCUIT CO0 xi4-CIRCUIT CO06-CIRCUIT Co4 056-CIRCUIT co3 x;2-CCT DID/TIE04-CIRCUIT DISA xi2-CCT DID/TIEx2-CCT DID/TIE0 :c:2-CCT DID/TIE04-CIRCUIT DISA124-CIRCUIT DISA8 014-CIRCUIT CD0l-6 CZT CO2-6 CCT DISA3-E&M MOWLE4-6 CCT DID5-** MORE ** B-QUIT7-DESC NWlBER8-SEL. OPTION9-EM MCD DISAO-ATTENDANT CONSOLE DISPLAY DESCR I PTORTRUUK TYPENWIBER OF TRKS ASSIGNEDCCMENTS014-CIFWIT Co0F1>6 CCT coF2>8 CCT DISAF3>E&M MCIXJLEF4>6 CCT DID F5>F6XU I TF7>DESC NUdBERF8>SEL. OPTIONF9>FO> 4.61Field Description DESCRIPTOR: This field lists the trunk circuit descriptors, numbers 01 to 25. Page 71
SECTION MITLSI 09-094~Zl O-NATRUNK TYPE: This field lists one of eight trunk types for each trunk circuit descriptor. Note that the selected trunk type (the one that appears on the command line) is not displayed on the softkeys. NUMBER OF TRKS ASSIGNED: This field records the number of trunks which use each trunk circuit descriptor. The trunk circuit descriptor can be assigned a new trunk type only if this field is zero. To clear the NUMBER OF TRKS ASSIGNED field, the trunks must first be deassigned. Refer to Table 4-27, Non-Dial-In Trunks and Table 4-28, Dial-In Trunks. When a trunk type is assigned to a trunk circuit descriptor, the system prohibits any changes by clearing those softkeys that can alter the trunk types. COMMENTS: This field is reserved for additional data (a maximum of 20 characters). It is stored by the system but not used. 4.62 Commands l-6 CCT CO: Pressing this softkey specifies the selected trunk circuit descriptor as a CO Trunk type. Pressing the ENTER softkey completes the selection and the TYPE field displays the 6-CIRCUIT CO prompt. 1-4 CCT CO: This softkey appears when the MORE softkey has been pressed. Pressing this softkey assigns the CO Trunk type to the se- lected trunk circuit descriptor. Pressing the ENTER softkey completes the selection and the TYPE field displays the 4-CIRCUIT CO prompt. l-T1 LS/GS: This softkey appears when the MORE softkey has been pressed for the second time. Pressing this softkey defines the selected trunk circuit descriptor as a Tl Trunk simulating an LS/GS Trunk. l-T1 CO DISA: This softkey appears when the MORE softkey has been pressed for the third time. Pressing this softkey defines the selected trunk circuit descriptor as a T’l Trunk simulating a CO DISA Trunk. 2-6 CCT DISA: Pressing this softkey assigns the DISA Trunk type to the selected trunk circuit descriptor. Pressing the ENTER softkey com- pletes the selection and the TYPE field displays the 6-CIRCUIT DISAprompt. 2-4 CCT DISA: This softkey appears when the MORE softkey has been pressed. Pressing this softkey selects the DISA Trunk type for that trunk circuit descriptor. Pressing the ENTER softkey completes the selection and the TYPE field displays the 4-CIRCUIT DISA prompt. 2-Tl E&M: This soltkey appears when the MORE softkey has been pressed for the second time. Pressing this softkey defines the selected trunk circuit descriptor as a Tl Trunk simulating an E&M Trunk. 2-Tl E&M DISA: This softkey appears when the MORE softkey has been pressed for the second time. Pressing this softkey defines the selected trunk circuit descriptor as a Tl Trunk simulating an E&M DISA Trunk.Page 72
Customer Data Entry (CDE) 3-E&M MODULE: Pressing this softkey programs the selected trunk circuit descriptor as an E&M Trunk Module. Pressing the ENTER softkeycompletes the selection and the TYPE field displays the E&M MODULE prompt. 3-E&M TRUNK: This softkey appears when the MORE softkey has been pressed. Pressing this softkey programs the selected trunk circuit descriptor as an E&M Trunk Card. Pressing the ENTER softkey com- pletes the selection and the TYPE field displays the E&M CARD prompt. 3-Tl DID/TIE: This softkey appears wh.en the MORE softkey has been pressed for the second time. Pressing this softkey defines the selected trunk circuit descriptor as a Tl Trunk simulating a DID/TIE Trunk. 3-Tl TIE DISA: This softkey appears when the MORE softkey has been pressed for the third time. Pressing this softkey defines the selected trunk circuit descriptor as a Tl Trunk simulating a TIE/DISA Trunk. 4-6 CCT DID:Pressing this softkey programs the selected trunk circuit descriptor as a DID Trunk. Pressing the ENTER softkey com- pletes the selection and the TYPE field displays the 6 CCT DID prompt. 4-DID/TIE: This softkey appears when the MORE softkey has been pressed. Pressing this softkey specifies the selected trunk circuit de- scriptor as a DID/Tie Trunk. Pressing the ENTER softkey completes the selection and the TYPE field displays the 2-CCT DID/TIE prompt. 5-** MORE **: This softkey presents mbre trunk type selections, each time it is pressed until it returns the softkeys to their original format. (Refer to Table 4-23, Trunk Circuit Descriptors and Figure 4-13, More Trunk Types). Note that the current selected trunk type softkey is left blank.l-4 aT co2-4 CCT DISA3-E & M TRWK4-DID/TIE5- 6-QUIT7-DESC NlNBER8-SEL. O!JTlcN9-EM TRK DISAO-TIE DISA l-T1 LWGS2-Tl E&M3-Tl DID/TIE 4-5- B-QUIT‘I-DESC NLMBER8-SEL. OPTION 9-O- l-T1DISAB-QUIT2-3-4- 7-DESC MhlBER8-SEL. OPTION 9-Figure 4-13 More Trunk Types5-O-6-QUIT: Pressing the QUIT softkey when editing this form returns the display to the level before the field was modified. The change is not saved. At all other times, pressing this softkey exits Form 13 and returns the display to the level where the forms are selected. B-CANCEL: This softkey appears after a programming error has oc-Page 73
SECTION MITLSI 09-094-ZIO-NA curred. Pressing the CANCEL softkey returns the display to the level where the programming error occurred. The CANCEL softkey appears with an error message. 7-DESC NUM:Pressing this softkey displays ENTER DESC NUM: prompt. This soltkey selects a trunk circuit descriptor number. The selection is completed by entering a valid number (1 to 25). 8-SEL. OPTIONS: Pressing the SEL. OPTIONS softkey displays a new form. This form displays the options (parameters) associated with the trunk type that is assigned to that trunk circuit descriptor. Refer to Table 4-24, Trunk Circuit Descriptor Options. 9-EM TRK DISA: This softkey appears when the MORE softkey has been pressed. Pressing this softkey commits the (E&M) analogue trunk as a DISA trunk. 9-EM MOD DISA: Pressing this softkey programs the selected trunk circuit descriptor as an EM MOD DISA. O-REVIEW: Pressing the REVIEW softkey displays a new form (refer to Table 4-26, Review List for Form 13). This form displays a list of trunks that use the selected trunk circuit descriptor. Note that this softkeyappears only if “NUMBER OF TRKS ASSIGNED” on command line is greater than zero. O-ENTER: This softkey appears only after data for an entry has been modified. Pressing the ENTER softkey commits each modification one at a time to the database. O-TIE DISA: This softkey appears when the MORE softkey has been pressed. Pressing this softkey commits the DID/TIE (analog) trunk as a DISA trunk. Page 74
Customer Data Entry (CDE) Options for Trunk Circuit Descriptors 4.63 This form appears only when the SEL. OPTIONS softkey is pressed (refer to Table 4-23, Trunk Circuit Descriptors). This form displays the options (parameters) associated with each trunk type assigned to each trunk circuit descriptor. Refer to Table 4-24, Trunk Circuit Descriptor Options. TABLE 4-24 TRUNK CIRCUIT DESCRIPTOR OPTIONS FOR FORM 13 CDE TERMINAL DISPLAY 4:26 PM 15-JAN-88alarm status = NO ALARM I4CCTCOTRU’JK: 2I OPTION NAME [SUPERVISION PARAMETER]STATUS Far-end gives answer supervision Inhibit automatic supervision LizNo seize alarmYESNo release alarmYESToll office No Is this a CO YES DTMF YESImpedance COMPLEXDictation TrunkNOFar-end gives answer supervision No 1 -YES2- 3-4-5- 6-QUIT7- 8-9-O-ATTENDANT CONSOLE DISPLAY [ 4CCTCOTRWJK:2 1 OPTION NAME [SUPERVISION PARAMETER] Far-end gives answer supervision Fl>YESF2>F3>F4>F5>F6>oU ITF7>F8>F9>FO>STATUS NO4.64Field Description.: The header line displays the trunk type, the trunk circuit descriptor number and the type of parameter under observation. The parameter types are: Supervision, Transmission, In- coming, Outgoing and In/Out Going. Refer to Table 4-25, Trunk Hard- ware Options for a complete list of these options. STATUS: This field lists the option selected for each parameter. 4.65 Commands l-YES, NO, COMPLEX, 600 OHM, 60/40, IMMEDIATE: This softkeytoggles the status of the parameters. 2-30/20, WINK: This softkey toggles the status of the parameters. 3-66/33, DELAY: This softkey toggles the status of the parameters. 4-DELAY INTEG: This softkey toggles the status of the parameters. 6-QUIT: Pressing the QUIT softkey when editing this form returns the Page 75
SECTION MITL9109-094-210-NAdisplay to the level before the field was modified. The change is not saved. The following warning prompt appears on the command line: DATA HAS BEEN CHANGED BUT NOT YET SAVED IN DATABASE -- “ENTER” TO SAVE. At all other times, pressing this softkey returns the display to the point where the SEL. OPTION softkey was pressed.6-CANCEL: This softkey appears after a programming error has oc- curred. Pressing the CANCEL softkey returns the display to the level where the programming error was made. The CANCEL softkey appears with an error message.O-ENTER: This softkey appears only after data for an entry has been modified. Pressing the ENTER softkey commits each modification one at a time to the database. After all changes have been completed, theuser must press the ENTER softkey again to commit the form to the database.TABLE 4-25 TRUNK HARDWARE OPTIONS 4-CIRCUIT Co TRWJK and 4-CIRCUIT DISAReverse to Idle Far-End Gives Answer Supervision Inhibit Automatic Supervision No Seize Alarm No Release Alarm Toll Office Is this a CC DTMFImpedance (600 Ohms or Complex) Dictation Trunk 6-CIRCUIT CC TRUVK and 6-CIRCUIT DISAReverse to Idle Far-End Gives Answer Supervision Inhibit Automatic Supervision No Seize Alarm No Release Alarm Toll Office Is this a CC DThlFImpedance (600 Ohms or Complex) Post Call Metering (0 -+ 15 seconds) Calling Party Disconnect Timer (I * 12 minutes) Dictation Trunk Ignore Remote Disconnect Disconnect Timer (100 -) 9900 ms)(100 ms increments) Supervision Direction:Incoming Trunk Calls Also Guard Timer (0 + 3000 ms) (100 ms increments) Ring Cycle Timer (6 -+ IO seconds) Ignore Line Reversal During Seizure Ringing Expected Ringing Debounce Timer (5 + 12 seconds) Seize Timer (IO -) 60 s) (IO s increments) Flash Timer (200 + 700 ms)(100 ms increments) Interdigit Timer (300 4 600 ms)(100 ms increments) Digit Outpulsing Ratio (60/40, 30/20, 66/33)Page 76
Customer Data Entry (CDE) TABLE 4-25 (CONT’D)TRUNK HARDWARE OPTIONS Type :E&M M(WXILE and E&M MCDJLE DI SA Reverse to Idle Far-End Gives Answer Supervision Inhibit Automatic Supervision No Seize Alarm No Release Alarm Toll Office Is this a CC Dl%lFImpedance ** Use Module Dip Switches to Program ** (600 Ohms or (Complex) E Lead Invert M Lead Invert ** required for type 5 operation **Disconnect Timer (150 4 300 msl(50 ms increments) Release Acknowledge Timer (2000 + 9900 ms)(100 ms inc) Guard Timer (200 -+ 1000 ms)(100 ms increments) Dictation Trunk Incoming Start Type (Imned, Wink, Delay)Debounce Timer (20 -+ 150 ms)(IO ms increments) Wink Timer (150 + 300 ms) (50 ms increments) Outgoing Start Type (lamed,Wink, Delay or Delay Integ)Digit Outpulsing Ratio (60/40, 30/20, 66/33)Outpulse Delay Timer (100 -+ 2000 ms)(100 ms inc)Flash Timer (200 + 700 ms)(100 ms increments) Interdigit Timer (300 - 800 ms)(100 ms increments) Wait for Delay Timer (300 --) 5000 ms)(100 ms inc) Remote End is a Satellite Remote End is a Satellite with OPS Lines E&M TRUUK CARDReverse to Idle Far-End Gives Answer Supervision Inhibit Automatic Supervision No Seize Alarm No Release Alarm Toll Office Is this a CC DTMFImpedance (600 Ohms or Complex) Remote End is a Satellite Remote End is a Satellite with OPS Lines Dictation Trunk 2-CCT DID/TIE and 2 CCT TIE DISAReverse to Idle Far-End Gives Answer Supervision Inhibit Automatic Supervision No Seize Alarm No Release Alarm Toll Office Is this a CoDlIlFImpedance (600 Ohms or Complex) Remote End is a Satellite Remote End is a Satellite with OPS Lines 6-CCT DID Reverse to Idle Far-End Gives Answer Supervision Inhibit Automatic Supervision Page 77
SECTION MITL9109-094-210-NATABLE 4-25 (CONT’D) TRUNK HARDWARE OPTIONS 6-CCT DID (CCM’D)No Seize Alarm No Release Alarm Toll Office Is this a- CD DTMFImpedance (600 Ohms or Complex) Disconnect Timer (150 -) 300 ms)(50 ms increments) Release Acknowledge Timer (2000 -+ 9900 ms)(100 ms inc) Guard Timer (200 -+ 1000 ms)(100 ms increments) Start Type (Inmed)Debounce Timer (20 --) 150 ms) (10 ms increments) Wink Timer (150 --( 300 ms) (50 ms increments) Remote End is a Satellite Remote End is a Satellite with OPS Lines ‘1 E&l and Tl E&M DISAReverse to Idle Far-End Gives Answer Supervision Inhibit Automatic Supervision No Seize Alarm No Release Alarm Toll Office Is this a CD DTMFDisconnect Timer (150 --( 300 ms) (50 ms inc)Release Acknowledge Timer (2000 -+ 9900 ms) (100 ms inc)Guard Timer (200 + 1000) (100 ms inc)Incoming Start Type (Iraned. Wink or Delay)Debounce Timer (20 + 150 ms) (10 ms inc.) Wink Timer (150 -) 300 ms) (50 ms inc)Outgoing Start Type (Imned, Wink, Delay or Delay Integ)Digit Outpulsing Ratio (60140, 60/20, 66133)Outpulse.Delay Timer (100 + 2000 ms) (100 ms inc)Flash Timer (200 -+ 700 ms) (100 ms inc)Interdigit Timer (300 + 600 ms) (100 ms inc)Wait for Delay Timer (300 + 5000 ms) (100 ms inc) Remote end is a satellite Remote end is a sate1 I i te with OPS Lines ‘1 DID/TIE and Tl TIE DISAFar-End Gives Answer Supervision Inhibit Automatic Supervision No Seize Alarm No Release Alarm Toll Office Is this a CD DTMFDisconnect Timer (150 -+ 300 ms) (50 ms inc) Release Acknowledge Timer (24 120 s)Guard Timer (200 + 1000) (100 ms inc) Start Type (Irmted, Wink or Delay1Debounce Timer (20 + 150 ms) (10 ms inc) Wink Timer (150 + 300 ms) (50 ms inc) Outgoing Start Type (Imned, Wink, Delay or Delay Integ)Digit Outpulsing Ratio (60140, 80/20, 66133)Outpulse Delay Timer (100 --) 2000 ms) (100 ms inc) Flash Timer (200 + 700 ms) (100 ms inc) Interdigit Timer (300 + 800 ms) (100 ms inc)Wait for Delay Timer (300 -( 5000 ms) (100 ms inc) Remote End is a Satellite Remote End is a Satellite With OPS Lines Page 78