Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual
Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual
Have a look at the manual Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Installation Forms TABLE 3-19 FORM 13 - TRUNK CIRCUIT DESCRIPTORS DESCRIPTOR NO. 1TYPECOMMENTS 06 07 0809 12 19 20 21 22 23 24 25Notes: 1. Specify a Trunk Type for the required trunk circuit descriptors. The Trunk Types include: 4-CCT CO, 4-CCT DISA, 6-CCT CO, 6-CCT DISA, E&M MODULE, E&M MODULE DISA, E&M CARD, E&M TRK DISA, 2-CCT DID/TIE, 2-CCT TIE DISA, 6-CCT DID, Tl E&M, Tl E&M DISA, Tl DID/TIE, Tl TIE DISA, Tl LS/GS, and Tl CO DISA, 2. The COMMENTS field stores additional information. It is not used by the system and can have a maximum of 20 characters. Page 35
SECTION MITL9109-094-206-NATABLE 3-20 FORM 13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _IImpedance (600 Ohms or Complex) Dictation Trunk (Y or N)Notes: 1. x This form is a nested form and can only be accessed from Form 13 (Trunk Circuit Descriptors), via the SEL. OPTIONS softkeys.2. Specify the hardware options for the selected trunk circuit descriptor number. The options can be specified only after a trunk type has been assigned to a trunk circuit descriptor number, Page 36
Installation Forms TABLE 3-20 (CONT’D) FORM 13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS !SHEET _ OF _6-CIRCUIT CO TRUNK andTRUNK CIRCUIT DESCRIPTOR NUMBER (1 - 25) 6-CIRCUIT DISAOPTIONS-12-3-4-5-6-7-8-91-0Reverse to Idle (Y or N)IFar-End Gives Answer Supervision (Y or N)Inhibit Automatic Supervision (Y or N)No Seize Alarm (Y or N)No Release Alarm (Y or N)Toll Office (Y or N)~-IInterdigit Timer 300 - 800 ms (100 ms inc) Digit OUtpUking Ratio (60/40, 80/20, 66/33)Notes: 1. JC This form is a nested form and can only be accessed from Form 13 (Trunk Circuit Descriptors), via the SEL. OPTIONS softkeys. 2. Specify the hardware options for the selected trunk circuit descriptor number. The options can be specified only after a trunk type has been assigned to a trunk circuit descriptor number. Page 37
SECTION MITL9109-094-206-NATABLE 3-20 (CONT’D) FORM 13% - TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _ Ime(Immed, Wink,Delay or Delay Flash Timer 200 - 700 ms (IO@ ms inc)Interdigit Timer 300 + 800 ms (100 ms inc)Wait for Delay Timer 300 - 5000 ms (100 ms inc)Page 38
Installation Forms TABLE 3-20 (CONT’D) FORM 13% - TRUNK CIRCUIT DESCRIPTOR OPTIONS E&M MODULE and E&M MODULE DISA OPTIONS Remote End is a Satellite (Y or N)Remote End is a Satellite with OPS Lines (Y or N)SHEET _ OF _TRUNK CIRCUIT DESCRIPTOR NUMBER (1 - 25) -1 -2 -3 -4 -5 -5 -7 -8 -9 -0Notes: 1. x This form is a nested form and can only be accessed from Form 13 (Trunk Circuit Descriptors), via the SEL. OPTIONS softkeys.2. Specify the hardware options for the selected trunk circuit descriptor number. The options can be specified only after a trunk type has been assigned to a trunk circuit descriptor number. Page 39
SECTION MITLSI 09-094-206-NATABLE 3-20 (CONT’D) FORM 13% - TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET OF Notes: 1. # This form is a nested form and can only be accessed from Form 13 (Trunk Circuit Descriptors), via the SEL. OPTIONS softkeys. 2. Specify the hardware options f6r the selected trunk circuit descriptor number. The options can be specified only after a trunk type has been assigned to a trunk circuit descriptor number. Page 40
Installation Forms TABLE 3-20 (CONT’D) FORM 13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _P-CIRCUIT DID/TIE and Remote Endis aSatellite withOPSLinesNotes: 1. x This form is a nested form and can only be accessed from Form 13 (Trunk Circuit Descriptors), via the SEL. OPTIONS softkeys.2. Specify the hardware options for the selected trunk circuit descriptor number. The options can be specified only after a trunk type has been assigned to a trunk circuit descriptor number. Page 41
SECTION MITL9109-094-206-NATABLE 3-20 (CONT’D) FORM 13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _II6-CIRCUIT DID OPTIONS Wink Timer 150 - 300 ms (50 ms inc)Remote End is a Satellite (Y or N)Remote End is a Satellite With OPS Lines (Y or N)Notes: 1. x This form is a nested form and can only be accessed from Form 13 (Trunk Circuit Descriptors), via the SEL. OPTIONS softkeys. 2. Specify the hardware options for the selected trunk circuit descriptor number. The options can be specified only after a trunk type has been assigned to a trunk circuit descriptor number. Page 42
Installation Forms TABLE 3-20 (CONT’D) FORM 13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET_OF _Outgoing Start Type (Immed, Wink, Delay or Delay Integ)Digit Outpulsing Ratio (60/40, 80/20, 66/33) Outpulse Delay Timer 100 - 2000 ms (100 ms inc) Flash Timer 200 - 700 ms (100 ms inc)Interdigit Timer 300 - 800 ms (100 ms inc) Wait for Delay Timer 300 - 6000 ms (100 ms inc) Remote end is a satellite (Y or N)Remote end is a satellite with OPS Lines (Y or N)Notes: 1. x This form is a nested form and can only be accessed from Form 13 (Trunk Circuit Descriptors), via the SEL. OPTIONS softkeys. 2. Specify the hardware options for the selected trunk circuit descriptor number. The options can be specified only after a trunk type has been assigned to a trunk circuit descriptor number. Page 43
SECTION MITL9109-094-206-NATABLE 3-20 (CONT’D) FORM 13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _ NoRelease Alarm(Y or N)Toll Office (Y or N)Is this a CO (Y or N)DTMF (Y or N)Disconnect Timer 150 - 300 ms (50 ms inc)Release Acknowledge Timer 2 - 120 sGuard Timer 200 - 1000 (100 ms inc) Start Type (Immed, Wink or Delay) Debounce Timer 20 - 150 ms (IO ms inc)Wink Timer 150 - 300 ms (50 ms inc) OUtgOing Stat? Type (Immed, Wink, Delay or Delay Integ)Digit Outpulsing Ratio (60/40, 60/20, 66/33) Outpulse Delay Timer IOO - 2000 ms (100 ms inc) Flash Timer 200 - 700 ms (100 ms inc)Interdigit Timer 300 - 800 ms (100 ms inc) Wait for Delay Timer 300 - 5000 ms (100 ms inc) Remote End is a Satellite (Y or N)Remote End is a Satellite with OPS Lines (Y or N)Notes: 1. * This form is a nested form and can only be accessed from Form 13 (Trunk Circuit Descriptors), via the SEL. OPTIONS softkeys.2. Specify the hardware options for the selected trunk circuit descriptor number. The options can be specified only after a trunk type has been assigned to a trunk circuit descriptor number. Page 44