Home > Mitel > Communications System > Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual

Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 618
    							Installation Forms
    TABLE 3-19
    FORM 13 - TRUNK CIRCUIT DESCRIPTORS
    DESCRIPTOR NO. 1TYPECOMMENTS
    06
    07
    0809
    12
    19
    20
    21
    22
    23
    24
    25Notes: 1. Specify a Trunk Type for the required trunk circuit descriptors. The Trunk Types include:
    4-CCT CO, 4-CCT DISA, 6-CCT CO, 6-CCT 
    DISA, E&M MODULE, E&M MODULE DISA,
    E&M CARD, E&M TRK 
    DISA, 2-CCT DID/TIE, 2-CCT TIE DISA, 6-CCT DID, Tl E&M, Tl E&M
    DISA, 
    Tl DID/TIE, Tl TIE DISA, Tl LS/GS, and Tl CO DISA,
    2. The COMMENTS field stores additional information. It is not used by the system and can
    have a maximum of 20 characters.
    Page 35 
    						
    							SECTION MITL9109-094-206-NATABLE 3-20
    FORM 
    13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS
    SHEET 
    _ OF _IImpedance (600 Ohms or Complex)
    Dictation Trunk 
    (Y or N)Notes: 1. 
    x This form is a nested form and can only be accessed from Form 13 (Trunk Circuit
    Descriptors), via the SEL. OPTIONS 
    softkeys.2. Specify the hardware options for the selected trunk circuit descriptor number. The
    options can be specified only after a trunk type has been assigned to a trunk circuit
    descriptor number,
    Page 36 
    						
    							Installation Forms
    TABLE 3-20 (CONT’D)
    FORM 13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS
    !SHEET _ OF _6-CIRCUIT CO TRUNK andTRUNK CIRCUIT DESCRIPTOR NUMBER (1 
    - 25)
    6-CIRCUIT
    DISAOPTIONS-12-3-4-5-6-7-8-91-0Reverse to Idle 
    (Y or N)IFar-End Gives Answer Supervision 
    (Y or N)Inhibit Automatic Supervision 
    (Y or N)No Seize Alarm 
    (Y or N)No Release Alarm 
    (Y or N)Toll Office 
    (Y or N)~-IInterdigit Timer 300 
    - 800 ms (100 ms inc)
    Digit 
    OUtpUking Ratio (60/40, 80/20, 66/33)Notes: 1. 
    JC This form is a nested form and can only be accessed from Form 13 (Trunk Circuit
    Descriptors), via the SEL. OPTIONS softkeys.
    2. Specify the hardware options for the selected trunk circuit descriptor number. The
    options can be specified only after a trunk type has been assigned to a trunk circuit
    descriptor number.
    Page 37 
    						
    							SECTION MITL9109-094-206-NATABLE 3-20 (CONT’D)
    FORM 
    13% - TRUNK CIRCUIT DESCRIPTOR OPTIONS
    SHEET 
    _ OF _
    Ime(Immed, Wink,Delay or Delay
    Flash Timer 200 
    - 700 ms (IO@ ms inc)Interdigit Timer 300 
    + 800 ms (100 ms inc)Wait for Delay Timer 
    300 - 5000 ms
    (100 ms inc)Page 38 
    						
    							Installation Forms
    TABLE 3-20 (CONT’D)
    FORM 13% - TRUNK CIRCUIT DESCRIPTOR OPTIONS
    E&M MODULE and
    E&M MODULE 
    DISA OPTIONS
    Remote End is a Satellite 
    (Y or N)Remote End is a Satellite with OPS Lines
    (Y or N)SHEET 
    _ OF _TRUNK CIRCUIT DESCRIPTOR NUMBER (1 
    - 25)
    -1 -2 -3 -4 -5 -5 -7 -8 -9 -0Notes: 1. 
    x This form is a nested form and can only be accessed from Form 13 (Trunk Circuit
    Descriptors), via the SEL. OPTIONS 
    softkeys.2. Specify the hardware options for the selected trunk circuit descriptor number. The
    options can be specified only after a trunk type has been assigned to a trunk circuit
    descriptor number.
    Page 
    39 
    						
    							SECTION MITLSI 09-094-206-NATABLE 3-20 (CONT’D)
    FORM 
    13% - TRUNK CIRCUIT DESCRIPTOR OPTIONS
    SHEET OF
    Notes: 1. 
    # This form is a nested form and can only be accessed from Form 13 (Trunk Circuit
    Descriptors), via the SEL. OPTIONS softkeys.
    2. Specify the hardware options 
    f6r the selected trunk circuit descriptor number. The
    options can be specified only after a trunk type has been assigned to a trunk circuit
    descriptor number.
    Page 40 
    						
    							Installation Forms
    TABLE 3-20 (CONT’D)
    FORM 13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS
    SHEET 
    _ OF _P-CIRCUIT DID/TIE and
    Remote Endis aSatellite withOPSLinesNotes: 1. 
    x This form is a nested form and can only be accessed from Form 13 (Trunk Circuit
    Descriptors), via the SEL. OPTIONS 
    softkeys.2. Specify the hardware options for the selected trunk circuit descriptor number. The
    options can be specified only after a trunk type has been assigned to a trunk circuit
    descriptor number.
    Page 41 
    						
    							SECTION MITL9109-094-206-NATABLE 3-20 (CONT’D)
    FORM 13x 
    - TRUNK CIRCUIT DESCRIPTOR OPTIONS
    SHEET 
    _ OF _II6-CIRCUIT DID
    OPTIONS
    Wink Timer 
    150 - 300 ms (50 ms inc)Remote End is a Satellite 
    (Y or N)Remote End is a Satellite With OPS Lines
    (Y or N)Notes: 1. 
    x This form is a nested form and can only be accessed from Form 13 (Trunk Circuit
    Descriptors), via the SEL. OPTIONS softkeys.
    2. Specify the hardware options for the selected trunk circuit descriptor number. The
    options can be specified only after a trunk type has been assigned to a trunk circuit
    descriptor number.
    Page 42 
    						
    							Installation Forms
    TABLE 3-20 (CONT’D)
    FORM 13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS
    SHEET_OF _Outgoing 
    Start Type (Immed, Wink, Delay or Delay
    Integ)Digit Outpulsing Ratio 
    (60/40, 80/20, 66/33)
    Outpulse Delay Timer 100 - 2000 ms
    (100 ms inc)
    Flash Timer 
    200 - 700 ms (100 ms inc)Interdigit Timer 300 
    - 800 ms (100 ms inc)
    Wait for Delay Timer 
    300 - 6000 ms
    (100 ms inc)
    Remote end is a satellite 
    (Y or N)Remote end is a satellite with OPS Lines
    (Y or N)Notes: 1. 
    x This form is a nested form and can only be accessed from Form 13 (Trunk Circuit
    Descriptors), via the SEL. OPTIONS softkeys.
    2. Specify the hardware options for the selected trunk circuit descriptor number. The
    options can be specified only after a trunk type has been assigned to a trunk circuit
    descriptor number.
    Page 43 
    						
    							SECTION MITL9109-094-206-NATABLE 3-20 (CONT’D)
    FORM 
    13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS
    SHEET 
    _ OF _
    NoRelease Alarm(Y or N)Toll Office 
    (Y or N)Is this a CO 
    (Y or N)DTMF 
    (Y or N)Disconnect Timer 
    150 - 300 ms (50 ms inc)Release Acknowledge Timer 2 
    - 120 sGuard Timer 
    200 - 1000 (100 ms inc)
    Start Type (Immed, Wink or Delay)
    Debounce Timer 20 - 150 ms (IO ms inc)Wink Timer 
    150 - 300 ms (50 ms inc)
    OUtgOing Stat? Type (Immed, Wink, Delay or Delay
    Integ)Digit Outpulsing Ratio 
    (60/40, 60/20, 66/33)
    Outpulse Delay Timer IOO - 2000 ms
    (100 ms inc)
    Flash Timer 
    200 - 700 ms (100 ms inc)Interdigit Timer 300 
    - 800 ms (100 ms inc)
    Wait for Delay Timer 300 
    - 5000 ms
    (100 ms inc)
    Remote End is a Satellite 
    (Y or N)Remote End is a Satellite with OPS Lines
    (Y or N)Notes: 1. 
    * This form is a nested form and can only be accessed from Form 13 (Trunk Circuit
    Descriptors), via the SEL. OPTIONS softkeys.2. Specify the hardware options for the selected trunk circuit descriptor number. The
    options can be specified only after a trunk type has been assigned to a trunk circuit
    descriptor number.
    Page 44 
    						
    All Mitel manuals Comments (0)

    Related Manuals for Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual