Have a look at the manual Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
SECTION MITL9109-094-320-NACHART 2-15 (CONT’D) DIAGNOSTICS LEVEL: ENABLING AND DISABLING DIAGNOSTICS StepActionVerify 8Press 7 (DISABLE-DIAGCommand line responds with: softkey).DISABLE-DIAG and softkey prompts change. 9Press 1 (BACKGROUNDCommand line responds with: softkey).DISABLE-DIAG BACKGROUND and softkeys change, as in Step 5. 10Repeat Steps 6 and 7.Background Diagnostics disable message appears in display area. The selected diagnostics are disabled. Softkey prompts return to Diagnostics Level format. 11Repeat for POWER-UP diagnostics. 12Press 6 (QUIT softkey) toTest completed. return to Maintenance menu.Page 26
System Test Procedures CHART 2-16 REMOVING EQUIPMENT FROM AND RETURNING EQUIPMENT TO SERVICEtepActionVerify 1Access MAINTENANCE System responds by displaying Maintenance menu. application. 2Press 3 (DIAGNOSTICSSoftkey prompts change. Diagnostics Level is accessed. softkey). 3Press 0 (MORE-KEYSSoftkey prompts change. softkey). 4Press 3 (BUSY-OUTCommand line responds with: softkey).BUSY-OUT and softkey prompts change. 5Select qualifier, by pressing System prompts for input, and no softkey prompts are either 1 (BAY/SLOT/CCT), 2 displayed. (DEVICE TYPE) , or 3 (EXT-NUM). 6Enter required informationBusy-out message appears in display area. The selected (press RETURN if requiredequipment is removed from service. after entry) and press 0 (ENTER softkey). 7Press 5 (CANCEL softkey).Softkey prompts return to Diagnostics Level format. 8Press 8 (RET-TO-SVCCommand line responds with: softkey).RET-TO-SVC and softkey prompts change. 9Repeat Steps 5 through 7Return To Service message appears in display area. The for same device.selected equipment is returned to service. Softkeyprompts return to Diagnostics Level format. IOPress 6 (QUIT softkey) toTest completed. return to Maintenance menu. Page 27
SECTION MITL9109-094-320-NACHART 2-17 STOPPING PRINTER TESTS StepActionVerify 1Access MAINTENANCESystem responds by displaying Maintenance menu. application 2Press 3 (DIAGNOSTICSSoftkey prompts change. Diagnostics Level is accessed. softkey). 3Press 9 (STOP-TESTSoftkey prompts change. softkey). 4Press 9 (PRINTERS softkey). command line responds with: STOP-TEST PRINTERS 5Press 5 (CANCEL softkey)or 0 (ENTER softkey). Page 28
System Test Procedures Traffic Measurement2.18The Traffic Measurement Level (accessed from the Maintenance menu of the Maintenance Terminal) allows the user to SET and SHOW, Traffic Measurement parameters, and PRINT and READ Traffic Measurement reports from the Maintenance Terminal. Chart 2-16 shows the steps for testing the Traffic Measurement Level. CHART 2-18 TRAFFIC MEASUREMENT StepActionVerify 1Access MAINTENANCESystem responds by displaying Maintenance menu. application. 2Press 5 (TRAFFIC MEASSoftkey prompts change. Traffic Measurement Level is softkey). accessed. 3Press 1 (SET softkey).Command line responds with: SETand softkey prompts change. 4Select a SET qualifierCommand line prompts for information to be input, and (UNITS, PERIOD, DURATION, softkey prompts change. AUTOPRINT, START TIME, or CONDENSED softkeys). 5Enter appropriateDisplay area displays parameter set, and softkey prompts information, either byreturn to Traffic Measurement Level format. pressing the required softkey, or by entering the required digits, then pressing ENTER. 6Repeat Steps 4 and 5 for remaining SET qualifiers. 7Press 2 (SHOW softkey).Command line responds with: SHOWand softkey prompts change. 8Press 3 (STATUS softkey).Command line responds with: SHOW STATUS TM and softkey prompts change. Go to Step 9. Page 29
SECTION MITL9109-094-320-NACHART 2-18 (CONT’D) TRAFFIC MEASUREMENT StepActionVerify 9Press 0 (ENTER softkey).Command line clears, and display area displays Traffic Measurement status, measurement units, period, duration, autoprint statks, and condensed report status. Softkeyprompts return to Traffic Measurement Level format. 10Press 3 (PRINT softkey).Command line responds with: PRINT TRAFFRPT ALLand softkey prompts change. 11Press 0 (ENTER softkey).Command line clears, softkey prompts return to Traffic Measurement Level format, display area displays PRINT TRAFFRPT ALL message, and traffic report is printed on the printer. 12Press 4 (READ softkey).Command line responds with: READ TRAFFRPT ALLand softkey prompts change. 13Press 0 (ENTER softkey).Command line clears, softkey prompts return to Traffic Measurement Level format. The message: ***** No Traffic Report Available I****appears in display area if no reports are available. Otherwise, traffic reports appear in display area. 14Press 9 (STOP softkey).Command line responds with: STOPand softkey prompts change. Go to Step 15. Page 30
System Test Procedures CHART 2-18 (CONT’D) TRAFFIC MEASUREMENTStepActionVerify 15Press 1 (TRAFFRPT softkey). Command line responds with: STOP TRAFFRPTand softkey prompts change. 16Press 0 (ENTER softkey).Command line clears, STOP TRAFFRPT message appears in display area, traffic reports are halted, and softkeyprompts return to Traffic Measurement Level format. 17Repeat Step 14. 18Press 3 (PRINT softkey).Command line responds with: STOP PRINT TM and softkey prompts change. 19Press 0 (ENTER softkey).Command line clears. STOP PRINT TM message appears in display area. Softkey prompts return to Traffic Measurement Level format. 20Press 6 (QUIT softkey) toTest completed. return to Maintenance menu. Page 31
SECTION MITL9109-094-320-NALogs 2.19The Logs Level (accessed from the Maintenance menu of the Maintenance Terminal) allows the user to read, print, and delete maintenance log entries made by the system. Log entries consist of anythirg which affects the functioning of the system, such as failed circuits, removed or installed cards, and Bay resets. Chart 2-19 shows the steps for testing the Logs Level. CHART 2-19 LOGS LEVEL StepActionVerify 1Access MAINTENANCE System responds by displaying Maintenance menu. application. 2Press 7 (LOGS softkey).Softkey prompts change. Logs Level is accessed. 3Press 1 (SET softkey).Command line responds with: SET4Press 4 (AUTOPRINTCommand line responds with: softkey). SET AUTOPRINT LOGSand softkey prompts change. 5Press 1 (ON softkey).Command line responds with: SET AUTOPRINT LOGS ON and softkey prompts change. 6Press 0 (ENTER softkey). Command line clears, SET AUTOPRINT LOGS ON message appears in display area, and softkey prompts return to Logs Level format. Log entries will be printed on the printer as they occur. Page 32
System Test Procedures CHART 2-19 (CONT’D)LOGS LEVEL StepAction Verify 7Repeat Steps 3 and 4.As in Step 4. Go to Step 8. 8Press 2 (OFF softkey).Command line responds with: SET AUTOPRINT LOGS OFFand softkey prompts change. 9Press 0 (ENTER sof-tkey).Command line clears, SET AUTOPRINT LOGS OFF message appears in display area, and softkey prompts return to Logs Level format. Autoprint is disabled. 10Press 2 (READ softkey).Command line responds with: READ LOGSand softkey prompts change. 11Select READ LOGS qualifier If NEWEST or OLDEST softkey pressed, command line by pressing 1 (NEWESTresponds with: softkey), 2 (OLDESTenter Number Of Entries, then press RETURN: softkey), or 4 (ALL softkey). 12If NEWEST or OLDESTCommand line responds with: softkeys pressed, enterREAD LOGS NEWEST 005number of entries desiredor (e.g., 5) either in the format READ LOGS OLDEST 005 005 or 5. If entered as less or, if ALL softkey pressed, than three digits, press READ LOGS ALL RETURN. 13Press 0 (ENTER softkey).Read Logs message appears in display area. Command line clears. Requested log entries scroll into display area. If more than four log entries are available, scrolling halts at end of fourth log entry. 14If more than four logIf MORE softkey pressed, next log entries scroll into entries are available, pressdisplay area. Scrolling halts at end of next four entries (or 0 (MORE softkey) tofewer, if no more entries are available). continue reading log entries, or 5 (CANCELIf CANCEL softkey pressed, command line clears, reading softkey) to cancel readingof logs is halted, and softkey prompts return to Logs Level logs.format. Go to Step 15. Page 33
SECTION MITL9109-094-320-NACHART 2-19 (CONT’D) LOGS LEVEL StepActionVerify 15Generate a log entry by extracting then re-installing a vo.ce card. DO NOT extract any of the following: @Main Control Card l Digital Interface Cards l Peripheral Control Cards l Scanner Cards l Bay Control Card@Switch Matrix Card Repeat Steps 13-15,Command line responds with: selecting NEWEST as the READ LOGS NEWEST 002READ LOGS qualifier, and when instructed enter 002and softkey prompts change. to read the two newest log entries. 16Press 0 (ENTER softkey).Newest log entries are displayed in display area, reporting card extraction and re-installation. Command line clears, and softkey prompts return to Logs Level format. 17Press 3 (PRINT softkey).Command line responds with: PRINT LOGSand softkey prompts change. 18Select a PRINT LOGSCommand line responds with either: qualifier by pressing either PRINT LOGS NEWEST enter Number of Entries: 1 (NEWEST softkey), 2 (OLDEST softkey), or 4 (ALL or softkey). PRINT LOGS OLDEST enter Number of Entries:or PRINT LOGS ALLdepending on which softkey was pressed, and softkeyprompts change. Go to Step 19. Page 34
System Test Procedures CHART 2-19 (CONT’D)LOGS LEVELVerify Step 19 20 21 22 23 24Action Press 0 (ENTER softkey).NOTE: Printing of logs can be halted at any time by pressing 9 (STOP softkey)and 0 (ENTER softkey). Press 4 (DELETE softkey). Select DELETE LOGSqualifier by pressing either 1 (NEWEST softkey)or 2 (OLDEST softkey)or 3 (ALL softkeys)Enter number of entries to be deleted. NOTE: Once deleted, entries cannot be recovered. If a record of log entries is required, print logs to be deleted, prior to executing step 26. Press 0 (ENTER softkey).(Press 8 (CONFIRM softkey)followed by 0 (ENTER softkey) in case of DELETE LOGS ALL.)Press 6 (QUIT softkey) to return to Maintenance menu.Selected logs are printed on printer. Softkey prompts return to Logs Level format. Command line responds with: DELETE LOGSand softkey prompts change. Command line responds with: DELETE LOGS NEWEST enter Number Of Entries, then press RETURN:or DELETE LOGS OLDEST enter Number Of Entries, then press RETURN:or DELETE LOGS ALL(CONFIRM softkey appears. Skip step 22.) Command line displays entries to be deleted, in the format: DELETE LOGS OLDEST 002Selected log entries are deleted. Command line clears. Softkey prompts return to Logs Level format. Verify log entries have been deleted by reading log entries (Steps 10-13, above). Test completed. Page 35