    Have a look at the manual Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 618
    							SECTION MITL9109-094-320-NACHART 2-15 (CONT’D)
    DIAGNOSTICS LEVEL: ENABLING AND DISABLING DIAGNOSTICS
    StepActionVerify
    8Press 7 (DISABLE-DIAGCommand line responds with:
    softkey).DISABLE-DIAG
    and 
    softkey prompts change.
    9Press 1 (BACKGROUNDCommand line responds with:
    softkey).DISABLE-DIAG BACKGROUND
    and 
    softkeys change, as in Step 5.
    10Repeat Steps 6 and 7.Background Diagnostics disable message appears in
    display area. The selected diagnostics are disabled.
    Softkey prompts return to Diagnostics Level format.
    11Repeat for POWER-UP
    diagnostics.
    12Press 6 (QUIT softkey) toTest completed.
    return to Maintenance
    menu.Page 26 
    						
    							System Test Procedures
    CHART 2-16
    REMOVING EQUIPMENT FROM AND RETURNING EQUIPMENT TO SERVICEtepActionVerify
    1Access MAINTENANCE
    System responds by displaying Maintenance menu.
    application.
    2Press 3 (DIAGNOSTICSSoftkey prompts change. Diagnostics Level is accessed.
    softkey).
    3Press 0 (MORE-KEYSSoftkey prompts change.
    softkey).
    4Press 3 (BUSY-OUTCommand line responds with:
    softkey).BUSY-OUT
    and 
    softkey prompts change.
    5Select qualifier, by pressing System prompts for input, and no softkey prompts are
    either 1 
    (BAY/SLOT/CCT), 2 displayed.
    (DEVICE TYPE) , or 3
    (EXT-NUM).
    6Enter required informationBusy-out message appears in display area. The selected
    (press RETURN if requiredequipment is removed from service.
    after entry) and press 0
    (ENTER softkey).
    7Press 5 (CANCEL softkey).Softkey prompts return to Diagnostics Level format.
    8Press 8 (RET-TO-SVCCommand line responds with:
    softkey).RET-TO-SVC
    and 
    softkey prompts change.
    9Repeat Steps 5 through 7Return To Service message appears in display area. The
    for same device.selected equipment is returned to service. 
    Softkeyprompts return to Diagnostics Level format.
    IOPress 6 (QUIT softkey) toTest completed.
    return to Maintenance
    menu.
    Page 27 
    						
    							SECTION MITL9109-094-320-NACHART 2-17
    STOPPING PRINTER TESTS
    StepActionVerify
    1Access MAINTENANCESystem responds by displaying Maintenance menu.
    application
    2Press 3 (DIAGNOSTICSSoftkey prompts change. Diagnostics Level is accessed.
    softkey).
    3Press 9 (STOP-TESTSoftkey prompts change.
    softkey).
    4Press 9 (PRINTERS softkey). command line responds with:
    STOP-TEST PRINTERS
    5Press 5 (CANCEL softkey)or 0 (ENTER softkey).
    Page 28 
    						
    							System Test Procedures
    Traffic Measurement2.18The Traffic Measurement Level (accessed from the Maintenance
    menu of the Maintenance Terminal) allows the user to SET and
    SHOW, Traffic Measurement parameters, and PRINT and READ Traffic
    Measurement reports from the Maintenance Terminal. Chart 2-16
    shows the steps for testing the Traffic Measurement Level.
    CHART 2-18
    TRAFFIC MEASUREMENT
    StepActionVerify
    1Access MAINTENANCESystem responds by displaying Maintenance menu.
    application.
    2Press 5 (TRAFFIC MEASSoftkey prompts change. Traffic Measurement Level is
    softkey).
    accessed.
    3Press 1 (SET softkey).Command line responds with:
    SETand 
    softkey prompts change.
    4Select a SET qualifierCommand line prompts for information to be input, and
    (UNITS, PERIOD, DURATION, 
    softkey prompts change.
    AUTOPRINT, START TIME,
    or CONDENSED softkeys).
    5Enter appropriateDisplay area displays parameter set, and softkey prompts
    information, either byreturn to Traffic Measurement Level format.
    pressing the required
    softkey, or by entering the
    required digits, then
    pressing ENTER.
    6Repeat Steps 4 and 5 for
    remaining SET qualifiers.
    7Press 2 (SHOW softkey).Command line responds with:
    SHOWand 
    softkey prompts change.
    8Press 3 (STATUS softkey).Command line responds with:
    SHOW STATUS TM
    and 
    softkey prompts change.
    Go to Step 9.
    Page 
    29 
    						
    							SECTION MITL9109-094-320-NACHART 2-18 (CONT’D)
    TRAFFIC MEASUREMENT
    StepActionVerify
    9Press 0 (ENTER softkey).Command line clears, and display area displays Traffic
    Measurement status, measurement units, period, duration,
    autoprint 
    statks, and condensed report status. Softkeyprompts return to Traffic Measurement Level format.
    10Press 3 (PRINT softkey).Command line responds with:
    PRINT TRAFFRPT ALLand 
    softkey prompts change.
    11Press 0 (ENTER softkey).Command line clears, softkey prompts return to Traffic
    Measurement Level format, display area displays PRINT
    TRAFFRPT ALL message, and traffic report is printed on
    the printer.
    12Press 4 (READ softkey).Command line responds with:
    READ TRAFFRPT ALLand 
    softkey prompts change.
    13Press 0 (ENTER softkey).Command line clears, softkey prompts return to Traffic
    Measurement Level format. The message:
    ***** No Traffic Report Available I****appears in display area if no reports are available.
    Otherwise, traffic reports appear in display area.
    14Press 9 (STOP softkey).Command line responds with:
    STOPand 
    softkey prompts change.
    Go to Step 15.
    Page 30 
    						
    							System Test Procedures
    CHART 2-18 (CONT’D)
    TRAFFIC MEASUREMENTStepActionVerify
    15Press 1 (TRAFFRPT softkey). Command line responds with:
    STOP TRAFFRPTand 
    softkey prompts change.
    16Press 0 (ENTER softkey).Command line clears, STOP TRAFFRPT message appears in
    display area, traffic reports are halted, and 
    softkeyprompts return to Traffic Measurement Level format.
    17Repeat Step 14.
    18Press 3 (PRINT softkey).Command line responds with:
    STOP PRINT TM
    and 
    softkey prompts change.
    19Press 0 (ENTER softkey).Command line clears. STOP PRINT TM message appears in
    display area. 
    Softkey prompts return to Traffic
    Measurement Level format.
    20Press 6 (QUIT softkey) toTest completed.
    return to Maintenance
    menu.
    Page 31 
    						
    							SECTION MITL9109-094-320-NALogs
    2.19The Logs Level (accessed from the Maintenance menu of the
    Maintenance Terminal) allows the user to read, print, and delete
    maintenance log entries made by the system. Log entries consist of
    anythirg which affects the functioning of the system, such as failed
    circuits, removed or installed cards, and Bay resets. Chart 
    2-19 shows
    the steps for testing the Logs Level.
    CHART 2-19
    LOGS LEVEL
    StepActionVerify
    1Access MAINTENANCE
    System responds by displaying Maintenance menu.
    application.
    2Press 7 (LOGS softkey).Softkey prompts change. Logs Level is accessed.
    3Press 1 (SET softkey).Command line responds with:
    SET4Press 4 (AUTOPRINTCommand line responds with:
    softkey).
    SET AUTOPRINT LOGSand 
    softkey prompts change.
    5Press 1 (ON softkey).Command line responds with:
    SET AUTOPRINT LOGS ON
    and 
    softkey prompts change.
    6Press 0 (ENTER softkey).
    Command line clears, SET AUTOPRINT LOGS ON message
    appears in display area, and 
    softkey prompts return to
    Logs Level format. Log entries will be printed on the
    printer as they occur.
    Page 32 
    						
    							System Test Procedures
    CHART 2-19 (CONT’D)LOGS LEVEL
    StepAction
    Verify
    7Repeat Steps 3 and 4.As in Step 4.
    Go to Step 8.
    8Press 2 (OFF softkey).Command line responds with:
    SET AUTOPRINT LOGS OFFand 
    softkey prompts change.
    9Press 0 (ENTER sof-tkey).Command line clears, SET AUTOPRINT LOGS OFF message
    appears in display area, and 
    softkey prompts return to
    Logs Level format. Autoprint is disabled.
    10Press 2 (READ softkey).Command line responds with:
    READ LOGSand 
    softkey prompts change.
    11Select READ LOGS qualifier If NEWEST or OLDEST softkey pressed, command line
    by pressing 1 (NEWESTresponds with:
    softkey), 2 (OLDESTenter Number Of Entries, then press RETURN:
    softkey), or 4 (ALL 
    softkey).
    12If NEWEST or OLDESTCommand line responds with:
    softkeys pressed, enterREAD LOGS NEWEST 005number of entries desiredor
    (e.g., 5) either in the format READ LOGS OLDEST 005
    005 or 5. If entered as less or, if ALL 
    softkey pressed,
    than three digits, press
    READ LOGS ALL
    RETURN.
    13Press 0 (ENTER softkey).Read Logs message appears in display area. Command
    line clears. Requested log entries scroll into display area.
    If more than four log entries are available, scrolling halts
    at end of fourth log entry.
    14If more than four logIf MORE softkey pressed, next log entries scroll into
    entries are available, pressdisplay area. Scrolling halts at end of next four entries (or
    0 (MORE 
    softkey) tofewer, if no more entries are available).
    continue reading log
    entries, or 5 (CANCELIf CANCEL 
    softkey pressed, command line clears, reading
    softkey) to cancel readingof logs is halted, and softkey prompts return to Logs Level
    logs.format.
    Go to Step 15.
    Page 33 
    						
    							SECTION MITL9109-094-320-NACHART 2-19 (CONT’D)
    LOGS LEVEL
    StepActionVerify
    15Generate a log entry by
    extracting then re-installing
    a 
    vo.ce card. DO NOT
    extract any of the
    following:
    @Main Control Card
    l Digital Interface Cards
    l Peripheral Control Cards
    l Scanner Cards
    l Bay Control Card@Switch Matrix Card
    Repeat Steps 13-15,Command line responds with:
    selecting NEWEST as the
    READ LOGS NEWEST 002READ LOGS qualifier, and
    when instructed enter 002and 
    softkey prompts change.
    to read the two newest log
    entries.
    16Press 0 (ENTER softkey).Newest log entries are displayed in display area, reporting
    card extraction and re-installation. Command line clears,
    and 
    softkey prompts return to Logs Level format.
    17Press 3 (PRINT softkey).Command line responds with:
    PRINT LOGSand 
    softkey prompts change.
    18Select a PRINT LOGSCommand line responds with either:
    qualifier by pressing either PRINT LOGS NEWEST enter Number of Entries:
    1 (NEWEST softkey), 2
    (OLDEST softkey), or 4 (ALL or
    softkey).
    PRINT LOGS OLDEST enter Number of
    Entries:or
    PRINT LOGS ALLdepending on which 
    softkey was pressed, and softkeyprompts change.
    Go to Step 19.
    Page 34 
    						
    							System Test Procedures
    CHART 2-19 (CONT’D)LOGS LEVELVerify
    Step
    19
    20
    21
    22
    23
    24Action
    Press 0 (ENTER 
    softkey).NOTE: Printing of logs can
    be halted at any time by
    pressing 9 (STOP 
    softkey)and 0 (ENTER softkey).
    Press 4 (DELETE softkey).
    Select DELETE LOGSqualifier by pressing either
    1 (NEWEST 
    softkey)or
    2 (OLDEST 
    softkey)or
    3 (ALL 
    softkeys)Enter number of entries to
    be deleted. NOTE: Once
    deleted, entries cannot be
    recovered. If a record of
    log entries is required,
    print logs to be deleted,
    prior to executing step 26.
    Press 0 (ENTER 
    softkey).(Press 8 (CONFIRM 
    softkey)followed by 0 (ENTER
    softkey) in case of DELETE
    LOGS ALL.)Press 6 (QUIT 
    softkey) to
    return to Maintenance
    menu.Selected logs are printed on printer. 
    Softkey prompts
    return to Logs Level format.
    Command line responds with:
    DELETE LOGSand 
    softkey prompts change.
    Command line responds with:
    DELETE LOGS NEWEST enter Number Of Entries, then
    press RETURN:or
    DELETE LOGS OLDEST enter Number Of Entries, then press
    RETURN:or
    DELETE LOGS ALL(CONFIRM 
    softkey appears. Skip step 22.)
    Command line displays entries to be deleted, in the
    format:
    DELETE LOGS OLDEST 002Selected log entries are deleted. Command line clears.
    Softkey prompts return to Logs Level format.
    Verify log entries have been deleted by reading log entries
    (Steps 10-13, above).
    Test completed.