Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual
Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual
Have a look at the manual Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Shipping, Receiving, and Installation Information TABLE 5-l MAINTENANCE PANEL RS-232 CONNECTOR PIN ASSIGNMENTSDTEDCERS-232RS-232data terminal equipment data communication equipment pinsignal[local (dte) port] [remote (dce) port] 2TRANSMIT DATAfrom terminalto modem 3RECEIVE DATAto terminalfrom modem 4REQUEST TO SENDfrom terminalto modem 5CLEAR TO SENDto terminal 6DATA SET READYto terminal 7SIGNAL GROUND 8CARRIER DETECTto terminalfrom modem 20DATA TERMINAL READYfrom terminalto modem Notes:Remote (DCE) connector may be on the Maintenance Panel or on the Power Distribution Panel at rear of cabinet. On the Universal Cabinet, RS-232 and PRINTER port connectors are wired as follows: J5 DTE pins 6, 8, and 20 are tied together. DCE pin 5 and DTE pin 20 are tied together. J8 PRINTER pins 6, 8, and 20 are tied together. Page 85
SECTION MITLSI 09-094-200-NATERMINAL REMOTE - DEDICATED, PUBLIC NETWORK REMOTELV LOCATED TERMINAL REMOTE - DIAL-UP TO DPABX VIA CENTRAL OFFICE ~0 PAIRCROSSCONNECTFOR AUTO-ANSWER MODEM.REMOTELV LOCATED TERMINAL NOTE: The Auto-Answer MODEM is permanently connected to onelocal station circuit (extension). 7707ElRFigure 5-18 Maintenance Terminal Connections - SX-200 Cabinet Page 86
Shipping, Receiving, and Installation Information REMOTE - DEDICATED, PUBLIC NETWORK REMOTELY LOCATED TERMINAL REMOTE - DIAL-UP REMOTELY LOCATED TERMINAL CONNECTAUTO-ANSWER MODEM. NOTE: The Auto-Answer MODEM is permanently connected to one local station circuit (extension).TO DPABX VIA CENTRAL OFFICE MODEM KAOl97EOROFigure 5-19 Maintenance Terminal Connections - SX-200 Universal Cabinet Page 87
CHART 5-18 INSTALL ATTENDANT CONSOLE-ISECTION MITL9109-094-200-NAStepActionComments 1.Unpack console and place it in position atRefer to Figure 5-20. Attendant workstation. 2.Connect headset (or handset) to its cord, andThe two jacks are in parallel; plug cord into jack at side of console.either may be used. 3.Plug the console modular cord into the jack atJack is marked LINE PORT. the back of the console and into its assigned modular telephone jack. 4.At the distribution frame, cross connect theFor wiring information for the cable from the modular jack to the PABX; to the consoles and the console modular console module of the Universal card. Refer tojacks, refer to Figure 5-25. Figure 5-21. The LCD Console connects to a Console Module on the Universal Card using a four-wire connec- tion. The Console jack on the Maintenance panel must be connected to its default position (Bay 2, Slot 3, Position 1 of a COMBO backplane or Bay 1 Slot 5 of a 672-port Control Cabinet), to allow access to the default connected to this jack, during installation and initial Customer Data Entry. The card slot must contain a Universal Card with a Console module in position 1. The maximum loop length from the cabinet to the console is 300 m (1000 ft) using 26-AWG wire.Notes: Page 88
Shipping, Receiving, and installation Information I,PRE-FORMED/ FOAM PACKAGING SHIPPING CARTON 7959EOROFigure 5-20 Unpacking Attendant Console Page 89
SECTION MITL9109-094-200-NA DPABX CROSS - y!I’IyMODULAR JACK 25 PAIR CONNECTORIZEDCABLE xQUAD STATION WIRE CONSOLEMODULAR CORDCONSOLE MODULE ON UNIVERSAL CARDNOTE:USE ONLY MITEL CABLE P/N 559900007 FOR THE CONSOLE MODULAR CORD. 770BEZRlFigure 5-21 Console Installation Page 90
Shipping, Receiving, and Installation Information CHART 5-19 INSTALL SUPERCONSOLE 1000TM ATTENDANT CONSOLE StepActionComments 1.Unpack console and place it in position at Attendant workstation. 2. 3.C )nnect handset (or headset) to its cord, andThe two jacks are in parallel; plug cord into jack at side of console.either may be used. Plug the console modular cord into the LINE PORT jack at the back of the console and into its assigned modular telephone jack. 4.At the distribution frame, cross connect the cable from the modular jack to its assigned Digital Line Card in the PABX. Refer to Figure 5-22.For console modular jack wiring information, refer to Figure 5-25. Notes:The Superconsole 1000 attendant console uses a two-wire connection to connect to one circuit on a Digital Line Card (tip to tip and ring to ring). The Console jack on the Maintenance panel must be connected to its default position (Bay 2, Slot 3, Circuit 2 of a COMBO backplane or Bay 1, Slot 5, Circuit 2 of a 672-port Control Cabinet), to allow access to the default database from a Superconsole 7000 attendant console connected to this jack, during installation and initial Customer Data Entry. The card slot must contain a Digital Line Card. The maximum loop length from the cabinet to the console is 1000 m (3300 ft) using 26-AWG wire. The RS-232 printer connector on the back of the Superconsole 1000 attendant console uses the following pins: pinsignalpinsignal 1frame ground6dataset ready 2transmit data7signalground 3receive data8carrierdetect 4ready to send20data terminal ready 5clear to send Page 91
SECTION MITL9109-094-200-NA PAEXCROSS -..--_CONNECT FIELDMODULAR JACK 25 PAIR CONNECTORIZED CABLE xSTATION WIRE(1 PAIR) CONSOLE MODULAR CORDTO ONE CIRCUIT ON A DIGITAL LINE CARD NOTE:USE ONLY MITEL CABLE P/N 559900007 FOR THE CONSOLE MODULAR CORD. KAO’IIOEOROFigure 5-22 Superconsole 1000 Attendant Console Installation Page 92
Shipping, Receiving, and Installation Information CHART 5-20 INSTALL UNIVERSAL CARD AND MODULESStepActionComments 1.While wearing the antistatic wrist strap, unpackFigure 5-23 shows a Universal the universal card(s) and its modules.Card and Modules. 2.Inspect for loose or missing components, andComplete repair tag, repack, and for damage.return any damaged or incorrect items. 3.Insert the modules into their assigned locations,Total power rating per universal press them until they snap into their standoffscard cannot exceed 10. and then insert the Universal card into its assigned slot in the card shelf. Refer to Figure5-24. 4. 5.Complete the Tip & Ring Assignment form forFor Tip & Ring assignments for each module on the Universal Card. Ensure thateach Universal Card module, refer the correct equipment cross-connections areto Figure 5-25, Table 5-2, and performed at the MDF to connect this card withTable 5-3. For module power its associated equipment.ratings, refer to Table 5-4. If a Console Module is not being installed in Bay 2, Slot 3, Circuit 1, remove the maintenancepanel cable from J27 of the backplane.-TABLE 5-2 BACKPLANE T&R ASSIGNMENTS FOR EACH MODULE POSITION Module Position 1Tl RlT2 R2T3 R3 2T4 R4T5 R516 R6 3T7 R7 T8 R8T9 R9 4T10 RlOTll RllT12 R12 Page 93
SECTION MITL9109-094-200-NATABLE 5-3 TIP 8i RING ASSIGNMENTS Module Tl RlT2 R2T3 R3 TX nc Relay 1Relay 2 (subcircult 5) (subcircuit 6) PA outputrelay contacts TRI RR1El Ml Note: The relays on the Receiver card are program-controlled (and are NOT associated with the DTMF receivers). The relay on the MOH/Pager is operated when the paging circuit is in use (primarily for controlling an external amplifier). The system will indicate an alarm and ignore the universal card if its total module power rating is greater than 10. Therelay contacts must not be used to switch AC mains power to a device, even if the device draws less current than the contact rating of 0.5 A.TABLE 5-4 MODULE POWER RATING IModulePower Ratinn Console Receiver/Relay MOH/Pager E&M Trunk5 2 1 3TABLE 5-5 CONSOLE MODULAR JACK CONNECTIONS Jack Pair PinColour 2yellow 5blackDescription Tl - line out Rl - line out Page 94