    Have a look at the manual Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 618
    							Shipping, Receiving, and Installation Information
    TABLE 5-l
    MAINTENANCE PANEL RS-232 CONNECTOR PIN ASSIGNMENTSDTEDCERS-232RS-232data terminal equipment data communication equipment
    pinsignal[local (dte) port]
    [remote (dce) port]
    2TRANSMIT DATAfrom terminalto modem
    3RECEIVE DATAto terminalfrom modem
    4REQUEST TO SENDfrom terminalto modem
    5CLEAR TO SENDto terminal
    6DATA SET READYto terminal
    7SIGNAL GROUND
    8CARRIER DETECTto terminalfrom modem
    20DATA TERMINAL READYfrom terminalto modem
    Notes:Remote (DCE) connector may be on the Maintenance Panel or on the Power Distribution Panel at
    rear of cabinet.
    On the Universal Cabinet, RS-232 and PRINTER port connectors are wired as follows:
    J5 DTE pins 6, 8, and 20 are tied together.
    DCE pin 5 and DTE pin 20 are tied together.
    J8 PRINTER pins 6, 8, and 20 are tied together.
    Page 85 
    						
    							SECTION MITLSI 09-094-200-NATERMINAL
    REMOTE 
    - DEDICATED, PUBLIC NETWORK
    REMOTELV LOCATED
    TERMINAL
    REMOTE 
    - DIAL-UP
    TO DPABX VIA
    CENTRAL OFFICE
    ~0 PAIRCROSSCONNECTFOR AUTO-ANSWER
    MODEM.REMOTELV LOCATED
    TERMINAL
    NOTE: The Auto-Answer MODEM is
    permanently connected to 
    onelocal station circuit (extension).
    7707ElRFigure 5-18 Maintenance Terminal Connections 
    - SX-200 Cabinet
    Page 86 
    						
    							Shipping, Receiving, and Installation Information
    REMOTE - DEDICATED, PUBLIC NETWORK
    REMOTELY LOCATED
    TERMINAL
    REMOTE 
    - DIAL-UP
    REMOTELY LOCATED
    TERMINAL
    CONNECTAUTO-ANSWER
    MODEM.
    NOTE: The Auto-Answer MODEM is
    permanently connected to one
    local station circuit (extension).TO DPABX VIA
    CENTRAL OFFICE
    MODEM
    KAOl97EOROFigure 5-19 Maintenance Terminal Connections 
    - SX-200 Universal Cabinet
    Page 87 
    						
    							CHART 5-18
    INSTALL ATTENDANT CONSOLE-ISECTION 
    MITL9109-094-200-NAStepActionComments
    1.Unpack console and place it in position atRefer to Figure 5-20.
    Attendant workstation.
    2.Connect headset (or handset) to its cord, andThe two jacks are in parallel;
    plug cord into jack at side of console.either may be used.
    3.Plug the console modular cord into the jack atJack is marked LINE PORT.
    the back of the console and into its assigned
    modular telephone jack.
    4.At the distribution frame, cross connect theFor wiring information for the
    cable from the modular jack to the PABX; to the consoles and the console modular
    console module of the Universal card. Refer tojacks, refer to Figure 5-25.
    Figure 5-21.
    The LCD Console connects to a Console Module on the Universal Card using a four-wire connec-
    tion.
    The Console jack on the Maintenance panel must be connected to its default position (Bay 2, Slot 3,
    Position 1 of a COMBO backplane or Bay 1 Slot 5 of a 672-port Control Cabinet), to allow access to
    the default connected to this jack, during installation and initial Customer Data Entry. The card slot
    must contain a Universal Card with a Console module in position 1.
    The maximum loop length from the cabinet to the console is 300 m (1000 ft) using 26-AWG wire.Notes:
    Page 88 
    						
    							Shipping, Receiving, and installation Information
    I,PRE-FORMED/ FOAM
    PACKAGING
    SHIPPING
    CARTON
    7959EOROFigure 5-20 Unpacking Attendant Console
    Page 89 
    						
    							SECTION MITL9109-094-200-NA
    DPABX
    CROSS
    - y!I’IyMODULAR
    JACK
    25 PAIR
    CONNECTORIZEDCABLE
    xQUAD
    STATION
    WIRE
    CONSOLEMODULAR
    CORDCONSOLE MODULE
    ON UNIVERSAL
    CARDNOTE:USE ONLY 
    MITEL CABLE
    P/N 559900007 FOR THE
    CONSOLE MODULAR CORD.
    770BEZRlFigure 5-21 Console Installation
    Page 90 
    						
    							Shipping, Receiving, and Installation Information
    CHART 5-19
    INSTALL SUPERCONSOLE 1000TM ATTENDANT CONSOLE
    StepActionComments
    1.Unpack console and place it in position at
    Attendant workstation.
    2.
    3.C 
    )nnect handset (or headset) to its cord, andThe two jacks are in parallel;
    plug cord into jack at side of console.either may be used.
    Plug the console modular cord into the LINE
    PORT jack at the back of the console and into
    its assigned modular telephone jack.
    4.At the distribution frame, cross connect the
    cable from the modular jack to its assigned
    Digital Line Card in the PABX. Refer to Figure
    5-22.For console modular jack wiring
    information, refer to Figure 5-25.
    Notes:The Superconsole 1000 attendant console uses a two-wire connection to connect to one circuit on
    a Digital Line Card (tip to tip and ring to ring).
    The Console jack on the Maintenance panel must be connected to its default position (Bay 2, Slot 3,
    Circuit 2 of a COMBO backplane or Bay 1, Slot 5, Circuit 2 of a 672-port Control Cabinet), to allow
    access to the default database from a Superconsole 7000 attendant console connected to this jack,
    during installation and initial Customer Data Entry. The card slot must contain a Digital Line Card.
    The maximum loop length from the cabinet to the console is 1000 m (3300 
    ft) using 26-AWG wire.
    The RS-232 printer connector on the back of the Superconsole 1000 attendant console uses the
    following pins:
    pinsignalpinsignal
    1frame ground6dataset ready
    2transmit data7signalground
    3receive data8carrierdetect
    4ready to send20data terminal ready
    5clear to send
    Page 91 
    						
    							SECTION MITL9109-094-200-NA
    PAEXCROSS
    -..--_CONNECT
    FIELDMODULAR
    JACK
    25 PAIR
    CONNECTORIZED
    CABLE
    xSTATION
    WIRE(1 PAIR)
    CONSOLE
    MODULAR
    CORDTO ONE CIRCUIT ON
    A DIGITAL LINE CARD
    NOTE:USE ONLY MITEL CABLE
    P/N 559900007 FOR THE
    CONSOLE MODULAR CORD.
    KAO’IIOEOROFigure 5-22 Superconsole 1000 Attendant Console Installation
    Page 92 
    						
    							Shipping, Receiving, and Installation Information
    CHART 5-20
    INSTALL UNIVERSAL CARD AND MODULESStepActionComments
    1.While wearing the antistatic wrist strap, unpackFigure 5-23 shows a Universal
    the universal card(s) and its modules.Card and Modules.
    2.Inspect for loose or missing components, andComplete repair tag, repack, and
    for damage.return any damaged or incorrect
    items.
    3.Insert the modules into their assigned locations,Total power rating per universal
    press them until they snap into their standoffscard cannot exceed 10.
    and then insert the Universal card into its
    assigned slot in the card shelf. Refer to Figure5-24.
    4.
    5.Complete the Tip & Ring Assignment form forFor Tip & Ring assignments for
    each module on the Universal Card. Ensure thateach Universal Card module, refer
    the correct equipment cross-connections areto Figure 5-25, Table 5-2, and
    performed at the MDF to connect this card withTable 5-3. For module power
    its associated equipment.ratings, refer to Table 5-4.
    If a Console Module is not being installed in
    Bay 2, Slot 3, Circuit 1, remove the maintenancepanel cable from J27 of the 
    backplane.-TABLE 5-2
    BACKPLANE T&R ASSIGNMENTS FOR EACH MODULE POSITION
    Module
    Position
    1Tl RlT2 R2T3 R3
    2T4 R4T5 R516 R6
    3T7 R7
    T8 R8T9 R9
    4T10 RlOTll RllT12 R12
    Page 93 
    						
    							SECTION MITL9109-094-200-NATABLE 5-3
    TIP 
    8i RING ASSIGNMENTS
    Module
    Tl RlT2 R2T3 R3
    TX
    nc
    Relay 1Relay 2
    (subcircult 5) (subcircuit 6)
    PA outputrelay contacts
    TRI RR1El Ml
    Note: The relays on the Receiver card are program-controlled (and are NOT
    associated with the DTMF receivers). The relay on the MOH/Pager is
    operated when the paging circuit is in use (primarily for controlling an
    external amplifier). The system will indicate an alarm and ignore the
    universal card if its total module power rating is greater than 10. Therelay contacts must not be used to switch AC mains power to a device,
    even if the device draws less current than the contact rating of 0.5 A.TABLE 5-4
    MODULE POWER RATING
    IModulePower Ratinn
    Console
    Receiver/Relay
    MOH/Pager
    E&M Trunk5
    2
    1
    3TABLE 5-5
    CONSOLE MODULAR JACK CONNECTIONS
    Jack
    Pair
    PinColour
    2yellow
    5blackDescription
    Tl - line out