Home > Mitel > Communications System > Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual

Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 618
    							MITEL STANDARD PRACTICESECTION MITL9109-094-200-NAIssue 
    1, April 1988
    SX-200” DIGITAL
    PRIVATE AUTOMATIC BRANCH EXCHANGE (PABX)
    SHIPPING, RECEIVING, AND INSTALLATION INFORMATION
    @Copyright 1988, MITEL Corporation. All rights reserved.
    T”Trademark of MITEL Corporation
    @Registered Trademark of MITEL Corporation 
    						
    							SECTION MITLSI 09-094-200-NA
    NOTICEThe information contained in this document is believed to be accurate in all respects but is
    not warranted by 
    Mite1 Corporation (MITEL). The information is subject to change without
    notice and should not be construed in any way as a commitment by 
    Mite1 or any of its
    affiliates or subsidiaries. 
    Mite1 and its affiliates and subsidiaries assume no responsibility
    for any errors or omissions in this document. Revisions of this document or new editions of
    it may be issued to incorporate such changes. 
    						
    							Shipping, Receiving, and Installation Information
    CONTENTS
    PAGE1. INTRODUCTION
    General.............................................1
    Reason for Issue......................................1
    Notice to Installation Personnel...........................12. CONFIGURATION
    General.............................................3
    Welded Control Cabinet.................................
    4
    Universal Control Cabinet................................
    4
    672-port Control Cabinet................................4
    Analog Peripheral Cabinet...............................
    4
    672-Port Peripheral Cabinet.............................
    11
    Printed Circuit Cards..................................11
    Control Shelf........................................11
    Analog Peripheral Shelf................................13
    Digital Peripheral Shelf.................................13
    Maintenance Panels...................................15
    Connecting Cables....................................
    16
    Power Fail Transfer...................................16
    DTMF Receiver/Relay Module............................16
    Night Bell Connection.................................17
    Attendant Console/Console Module.......................17
    Paging, Music on Hold Equipment........................
    17Alternate Music Source 
    - ACD only
    .......................18
    E&M Trunk Module....................................
    18
    Reserve Power Supply.................................18Remote Maintenance of an 
    SX-2OCJ@ DIGITAL PABX...........18
    Data Cabinet, Datashelf, and 
    Datasets......................18
    Modem Pooling Installation.............................
    1 g3. INSTALLATION REQUIREMENTS
    Environmental Requirements............................2 1
    Floor Space.........................................21
    Equipment Location...................................21
    Power Supply Requirements.............................22
    Recommendations....................................
    22
    Equipment Grounding..................................
    224. CONTROL SHELF AND PERIPHERAL SHELF BACKPLANES AND WIRING
    Control Shelf (with COMBO backplane 
    - 336, 456, and 480 ports) . 25
    672-Port Control Cabinet and Control Backplane.............25
    Peripheral Shelf 
    - 480-Port Configuration...................25
    Peripheral Shelf 
    - 336-Port Configuration...................26
    Peripheral Shelf 456-Port Configuration....................
    26
    672-Port Peripheral Cabinet and Shelves...................
    265. INSTALLATION CHARTS
    Precautions.........................................45
    Overview of System Installation..........................
    45
    System Configuration..................................
    46672 
    Port System Installation
    .............................46
    . . .III 
    						
    							SECTION MITL9109-094-200-NACONTENTS (CONT’D)
    PAGEDisk Handling Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
    1306. CABLING AND CROSS-CONNECTIONS
    General . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . 133
    Telephone Set and Trunk Cabling . . . . . . . . . . . . . . . . . . . . . . . .
    133System Cable Terminations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
    7. UPGRADING AN EXISTING SX-200 PABX TO AN SX-200 DIGITAL PABX
    Strategy........................................... 145
    General Comments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
    8. UPGRADE A 336 PORT PABX TO A 672 PORT PERIPHERAL CABINET
    General...........................................149TABLETITLE
    PAGE2-l
    5-l
    5-2
    5-3
    5-4
    5-5
    5-6
    6-l
    6-2
    6-3
    6-4
    6-5
    6-6
    6-7
    6-8
    6-9
    6-10
    6-11
    PCM Cable Connections.......................16Maintenance Panel RS-232 Connector Pin Assignments 85
    Backplane T&R Assignments for Each Module Position . 93
    Tip 
    & Ring Assignments
    ........................94
    Module Power Rating..........................
    94
    Console Modular Jack Connections...............
    94
    E&M Trunk Module Switch Settings...............
    95
    Control Shelf Tip 
    & Ring Assignments...........134
    Control Shelf Tip 
    & Ring Assignments...........135
    Control Shelf Tip 
    81 Ring Assignments...........136
    Power Fail Transfer 
    Jl Connections..............137
    External Plug and Jack Connections (to Cross-Connect
    Field)....................................138
    External Plug and Jack Connections (to Cross-Connect
    Field)...................................139
    External Plug and Jack Connections (to Cross-Connect
    Field)...................................140
    External Plug and Jack Connections (to Cross-Connect
    Field)...................................141
    Interconnect Card Connections Bay 3 Plug PI9 orBay 4 Plug 
    P19.............................142
    Bay 3 or Bay 4 Power Fail Transfer Card Connections
    143
    USOC Connector Pin Designations...............
    144LIST OF TABLES 
    						
    							Shipping, Receiving, and Installation Information
    CHARTTITLE
    PAGE
    5-15-2
    5-3
    5-4
    5-5
    5-6
    5-7
    5-8
    5-9
    5-10
    5-115-12
    5-13
    5-14
    5-15
    5-16
    5-17
    5-18
    5-19
    5-20
    5-21
    5-22
    5-23
    5-24
    5-25
    5-26
    5-27
    5-28
    5-29
    5-30
    5-31
    5-32
    5-33
    7-l
    8-1
    Prepare System Configuration...................47
    Unpack Equipment Cabinets and Equipment Except
    Printed Circuit Boards.......................
    48
    Inspect Equipment............................
    48
    Install Control Cabinet.........................
    50
    Verify Ground Connection......................
    51
    Install Analog Peripheral Cabinet.................52
    Install a 672-Port Digital Peripheral Cabinet.........
    52Install an Analog Bay 3 Kit into an 
    SX-ZOO
    Cabinet..................................
    54Install an Analog Bay 3 Kit into an SX-200
    Universal Cabinet...........................58
    Install Digital Peripheral Bay....................
    61
    PFT Kit Installation Instructions - Universal
    Cabinet..................................
    73
    Install Bay 5.................................
    78
    Analog Peripheral Cabinet Reserve Power Supply
    Installation................................
    79
    Install Uninterruptable Power Supply (UPS)..........
    80
    Connect Cables to System and Cross-Connect
    Field.....................................83
    Cross-Connect Cables at Cross-Connect Field.......
    83Install Maintenance Terminal to an SX-200
    Control Cabinet............................84
    Install Attendant Console.......................
    88
    Install Super-console 
    1000TM Attendant
    Console.................................
    91
    Install Universal Card and Modules................93Install Floppy Disk Drive pn 9109-124-000..........
    99
    Unpack and Install Printed Circuit Cards...........
    102
    Install a Main Control Card.....................
    105Install a 
    Tl Trunk Card - Including Adapter and
    Tl Clock Module..........................106Installation of Modem Pooling on an SX-200
    DIGITAL PABX............................112Set CO Trunk Card Switches (Types -01 l/l 11)......
    115Set CO Trunk Card Switches (Types 
    -211/311)......118
    Set E&M/TIE Trunk Card Option Switches..........
    122
    Set DID/TIE Trunk Card Option Switches..........
    125
    Set 
    LWGS Trunk Card Jumpers.................127Initial System Power-On......................
    129
    Install Diskette into Disk Drive..................
    130
    Repacking for Shipment.......................
    131SX-200 PABX Upgrade to SX-200 DIGITAL PABX....
    146Convert a 336 Port Control Cabinet to a 672 Port
    Peripheral Cabinet.........................149LIST OF CHARTS
    V 
    						
    							SECTION MITLSI 09-094~200-NALIST OF ILLUSTRATIONS
    FIGURETITLE
    PAGE2-l
    2-2
    2-3
    2-4
    2-5
    2-6
    2-7
    2-8
    4-l
    4-2
    4-3
    4-4
    4-5
    4-6
    4-7
    4-8
    4-9
    4-10
    4-11
    4-12
    4-13
    4-14
    4-15
    4-16
    4-17
    4-18
    5-15-2
    5-3
    5-4
    5-5
    5-6
    5-7
    5-8
    5-9
    5-10
    5-115-12
    5-13
    5-14SX-200 DIGITAL PABX Welded Control Cabinet........
    5
    SX-200 Universa! Control Cabinet.................6Universal Control Cabinet with Digital Peripheral Shelf . . 7
    SX-200 DIGITAL PABX Peripheral Cabinet............8SX-200 672 port DIGITAL PABX Control Cabinet.......
    9
    SX-200 672 port DIGITAL PABX Peripheral Cabinet....10
    Main Control Card and Decryption Module..........12
    Digital Interface Card..........................14
    SX-200 Welded Cabinet Control Shelf Backplane.....27Rear View of SX-200 Control Cabinet 
    - Grounding....28Rear View of SX-200 Control Cabinet 
    - Power.......29Rear View of SX-200 Control Cabinet 
    - Signal Cables . 30
    SX-200 Universal Cabinet Control Shelf Backplane....31Rear View of SX-200 Universal Control Cabinet 
    -
    Grounding................................32Rear View of SX-200 Universal Control Cabinet 
    - Power 33
    Rear View of SX-200 Universal Control Cabinet 
    -
    Signal Cables..............................34
    SX-200 Connector Locations (Peripheral Cabinet).....
    35
    Power Fail Transfer Wiring Diagram...............
    36
    SX-200 Peripheral Cabinet Backplanes.............
    37
    Universal Cabinet (Digital Shelf) AC Distribution and
    Grounding................................
    38
    Universal Cabinet (Digital Shelf) Signal Cables except
    to MDF...................................
    39
    672-Port Control Backplane.....................
    40Rear View of 672-Port Control Cabinet 
    - Power and
    Grounding................................41Rear View of 672-Port Control Cabinet 
    - PCM Signal
    Cables...................................42
    Rear View of 672-Port Peripheral Cabinet 
    - Power and
    Grounding................................
    43
    Rear View of 672-Port Peripheral Cabinet 
    - PCM Signal
    Cables...................................
    44
    Remove External Packaging.....................
    49
    Installation of an Intercabinet Cable Assembly (672 port) 53
    Cardfile to Frame and Backplane Ground Connections . 62
    Interconnect Card Ground and DC Power Cable
    Connections.................................
    63
    DC Power Cable (PN114904501)..................
    64Installation of Rear Door Power Supply and Supports . . 65
    Installation of Fan Assembly.....................66
    Install Digital Peripheral Bay and Panel.............
    68
    Digital Peripheral Bay Connections................
    69Digital Peripheral 
    Cardfile Ground Connection Details . . 70
    Digital Peripheral Ground Connection Details........71
    Digital Peripheral Backplane Ground Connection Details 72
    Power Fail Transfer Card.......................
    75
    Locating PFT Card in an SX-200 Universal Cabinet....
    76
    Vi 
    						
    							Shipping, Receiving, and Installation InformationFIGURE5-15
    5-16
    5-17
    5-18
    5-19
    5-20
    5-215-22
    5-23
    5-24
    5-25
    5-26
    5-27
    5-28
    5-29
    5-30
    5-3 15-32
    5-33
    5-34
    5-35
    5-36
    5-37
    5-38
    5-39
    5-40
    5-41LIST OF ILLUSTRATIONS (CONT’D)
    TITLEPAGE
    PFT Card Connections.........................
    77
    Charging Unit...............................
    81
    Reserve Power Supply.........................82Maintenance Terminal Connections 
    - SX-200 Cabinet . 86
    Maintenance Terminal Connections - SX-200 Universal
    Cabinet..................................
    87
    Unpacking Attendant Console....................
    89
    Console Installation...........................
    90
    Superconsole 1000 Attendant Console Installation....
    92
    Universal Card and Modules.....................
    96
    Installation of Module onto Universal Card..........
    97
    Music, Paging, and Relay Connections.............
    98
    Floppy Disk Drives...........................
    100
    Disk Drive Connections.......................
    101
    Printed Circuit Card Packaging..................104
    Installation of Modules onto an MCC.............
    107Installation of a 
    Tl Clock Module onto an MCC.....108
    Main Control Card Jumpers and Switches.........
    109Installation of a 
    Tl Adapter Cable Assembly........110Installation of a 
    Tl Adapter Card onto a Backplane . . 111
    Modem Pooling with a Standalone 
    DATASET.......113
    Modem Pooling with Rack Mounted 
    DATASET and
    Modem Interconnect Panel...................
    114CO Trunk Card Types 91 
    lo-01 1 and -111.........116
    CO Trunk Card Switch Functions................
    119
    E&M/Tie Trunk Card Switch Settings.............
    123
    DID 
    / TIE Trunk Card Switch Functions............126
    LWGS Trunk Card...........................128
    Disk Drive Latches...........................
    132
    vii 
    						
    							Shipping, Receiving, and Installation Information
    1. INTRODUCTIONGeneral
    1.01This section provides a general identification, and shipping,
    receiving, and installation procedures for the SX-2OU@ DIGITALPABX. The PABX consists of one or two cabinets. The 
    Control cabinet
    contains a control shelf and an optional peripheral shelf. The 2-cabinet
    configuration consists of the Control cabinet, and a Peripheral cabinet
    containing one or two peripheral shelves.Reason for Issue
    1.02This Section is issued to provide information required for in-
    stalling the SX-200 DIGITAL PABX, with Generic 1003 software,
    in a 336-port, a 456-port, a 
    480-port, or a 672-port configuration.
    Notice to Installation Personnel
    1.03 Only persons who have successfully completed a 
    MITEL In-
    stallation and Maintenance training course for the SX-200 DIGI-
    TAL PABX should install an SX-200 DIGITAL PABX.
    Page 1 
    						
    							SECTION MITL9109-094-200-NA
    Page 2 
    						
    All Mitel manuals Comments (0)

    Related Manuals for Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual