    Have a look at the manual Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 618
    							Installation FormsTABLE5-9(CONT’D)ANALOG BAY 3 PLUG ASSIGNMENTS
    PLUG P3 (at Cross-Connect Field)48V-e
    23G-V
    49V-BR24BR-V
    50v-s25s-vSPARE
    SPARE
    Page 135 
    						
    							SECTION MITLSI 09-094-206-NATABLE5-9(CONT’D)
    ANALOG BAY 3 PLUG ASSIGNMENTS
    PLUG P4 (at Cross-Connect Field)
    Bay/PairSlotcctPinColour
    3-7
    26W-EL1BL-W27w-o
    $8o-w
    W-G3G-W29W-BR4BR-W
    3-8
    30w-s
    :Is-w
    R-BL6BL-R32R-O
    ;3O-R
    R-G8G-R
    3-9
    34R-BR9BR-R35R-S::S-R
    BK-BL
    11BL-BK
    37BK-0
    120-BK
    3-10
    38BK-G13G-BK39BK-BR14BR-BK
    40BK-S
    15S-BK41Y-BL16BL-Y
    3-l 142Y-O
    17O-Y
    43Y-G
    18G-Y
    44Y-BR
    19BR-Y
    45Y-S
    20S-Y
    3-1246V-BL
    21BL-V
    47v-o
    22o-v
    48V-G
    23G-V
    49V-BR
    24BR-V
    50v-sSPARE
    25S-VSPAREConnection/Comments
    (Extension Circuit Feature)
    Page 136 
    						
    							Installation Forms’
    TABLE5-9(CONT’D)
    ANALOG BAY 3 PLUG ASSIGNMENTSPLUG P5 (at Cross-Connect Field)
    Bay/PairSlotcctPinColour3-13
    26W-BL1BL-W27w-o
    o-w
    $8 W-G
    z9G-W
    W-BR4BR-W
    3-14
    30w-s
    ;Is-w
    R-BL:2BL-R
    R-O
    :3O-R R-G8G-R
    3-15
    34R-BR
    $5BR-R
    R-S
    IOS-R
    36BK-BL
    i:BL-BK
    BK-0120-BK
    PLUG P6 (at Cross-Connect Field)Connection/Comments
    (Extension Circuit Feature)
    3-13
    .38BK-G
    :iG-BK
    BK-BR14BR-BK
    40BK-S
    15S-BK41Y-BL16BL-Y
    3-1442Y-O
    17O-Y
    43Y-G
    18G-Y
    44Y-BR
    19BR-Y
    45Y-S
    20S-Y
    3-1546V-BL
    21BL-V
    47v-o
    22o-v
    48V-G
    23G-V
    49V-BR
    24BR-V
    50v-sSPARE25s-vSPAREPage 137 
    						
    							SECTION MITL9109-094~206-NATABLE5-10
    ANALOG BAY 4 PLUG ASSIGNMENTS
    PLUG P2 (at Cross-Connect Field)Bay/
    Blot
    4-l
    4-2
    1-31-4
    r-51-6
    PairConnection/Comments
    cctPinColour(Extension Circuit Feature)
    26W-BL,:7BL-W
    w-o
    Z8o-w
    W-G3G-W29W-BR4BR-W
    30w-s
    :Is-w
    R-BL6BL-R
    32
    :3
    ;I;R-G
    8G-R
    34R-BR9BR-R35R-S
    iiS-R
    BK-BL::BL-BK
    BK-0
    120-BK
    38BK-G13G-BK39BK-BR14BR-BK
    40BK-S
    15S-BK41Y-BL16BL-Y
    42Y-O
    17O-Y
    43Y-G
    18G-Y
    44Y-BR
    19BR-Y
    45Y-S
    20S-Y
    46V-BL
    21BL-V
    4:v-o
    o-v
    48V-G
    23G-V
    49V-BR
    24BR-V
    50v-sSPARE25S-VSPAREPage 138 
    						
    							Installation Forms
    TABLE 5-10 (CONT’D)
    ANALOG BAY 4 PLUG ASSIGNMENTSPLUGP3 (at Cross-Connect Field)
    22o-v
    48V-G
    23G-V
    49V-M24BR-V
    50v-s25s-vSPARE
    SPAREPage 139 
    						
    							SECTION MITL9109-094-206-NATABLE5-10(CONT’D)
    ANALOG BAY 4 PLUG ASSIGNMENTS
    PLUG P4 (at Cross-Connect Field)
    Bay/PairConnection/Comments
    Slot
    cctPinColour
    (Extension Circuit Feature)
    4-7
    26W-BL:7BL-W
    w-o
    2o-w28W-G3G-W29W-BR4BR-W
    4-8
    30W-S
    :Is-w
    R-BL:2BL-R
    R-O
    ;3O-R
    R-G8G-R
    4-9
    34R-BR
    i5BR-R
    R-S10S-R36BK-BL2BL-BK
    BK-0
    120-BK
    4-10
    38BK-G13G-BK39BK-BR14BR-BK40BK-S15S-BK41Y-BL16BL-Y
    4-1142Y-O
    17O-Y43Y-G18G-Y44Y-BR19BR-Y
    45Y-S
    20S-Y
    1-1246V-BL21BL-V47v-o22o-v
    48V-G
    23G-V49V-BR24BR-V
    50v-sSPARE
    25s-vSPAREPage 140 
    						
    							Installation Forms
    TABLE 5-10 (CONT’D)
    ANALOG BAY 4 PLUG ASSIGNMENTS
    PLUG PI9 onInterconnect Card (Miscellaneous Connections to Cross-ConnectField)Bay/
    Slot
    4-15
    4-14
    4-13
    4-15
    4-14
    1-13
    I
    PairConnection/Comments
    CctPinColour(Extension Circuit Feature)
    26W-BLSPARE1BL-WSPARE
    27w-o
    &Io-w
    W-G
    ;9G-W
    W-BR4BR-W30w-s5s-w
    31R-BL
    BL-R
    i2 R-O
    z3O-R
    R-G8G-R34R-BR9BR-R
    35R-S10S-R36BK-BL11BL-BK37BK-0
    ii0-BK
    BK-G13G-BK
    39BK-BR14BR-BK
    40BK-S
    15S-BK41Y-BL16BL-Y
    42Y-O
    17O-Y
    43Y-G18G-Y44Y-BR19BR-Y
    45Y-S
    20S-Y
    46V-BL
    21BL-V
    47v-o
    22o-v
    48V-G
    23G-V
    49V-BR
    BR-V
    fi v-s25S-V
    Page 141 
    						
    							SECTION MITL9109-094~206-NATABLE5-11
    ANALOG BAY 5 PLUG ASSIGNMENTS
    PLUG P7 (at Cross-Connect Field)
    Bay/Pair
    SlotcctPinColour
    5-l
    25W-BL1BL-W27w-o2o-w28W-G
    ;9G-W
    W-BR4BR-W
    5-2
    30w-s
    ;Is-w
    R-BL6BL-R
    32R-O
    :3O-R
    R-G
    8G-R
    5-3
    34R-BR9BR-R35R-S
    iiS-R
    BK-BL11BL-BK37BK-0120-BK
    5-4
    38BK-G
    ii:G-BK
    BK-BR14BR-BK
    40BK-S
    15S-BK41Y-BL16BL-Y
    5-542Y-O
    17O-Y
    43Y-G
    18G-Y
    44Y-BR
    19BR-Y
    45Y-S
    20S-Y
    j-646V-BL21BL-V
    47v-o
    22o-v48V-G23G-V
    49V-BR
    24BR-V
    9:v-sSPAREs-vSPAREConnection/Comments
    (Extension Circuit Feature)
    Page 142 
    						
    							Installation Forms
    TABLE5-11(CONT’D)
    ANALOG BAY 5 PLUG ASSIGNMENTSPLUG P8 (at Cross-Connect Field)
    Bay/Slot
    5-l
    5-2
    5-3
    5-4
    j-5
    j-6
    PairConnection/Comments
    cctPinColour(Extension Circuit Feature)
    26W-BL1BL-W27W-O
    $8o-w
    W-G
    ;9G-W
    W-BR4BR-W
    30w-s5S-W31R-BL
    i2BL-R
    R-O
    i3O-R8;I;
    34R-BR:5BR-R
    R-S
    10S-R36BK-BL2BL-BK
    BK-0
    120-BK
    38BK-G13G-BK39BK-BR14BR-BK
    40BK-S
    15S-BK41Y-BL16BL-Y
    42Y-O
    17O-Y
    43Y-G
    18G-Y
    44Y-BR
    19BR-Y
    45Y-S
    20S-Y
    46V-BL
    21BL-V
    47v-o
    22o-v
    48V-G
    23G-V
    49V-BR
    24BR-V
    2v-sSPAREs-vSPAREPage 143 
    						
    							SECTION MITL9109-094-206-NATABLE5-11(CONT’D)
    ANALOG BAY 5 PLUG ASSIGNMENTS
    PLUG P9 (at Cross-Connect Field)
    Bay/PairSlotCctPinColour
    5-7
    26W-EL1BL-W27w-o2o-w26W-G19G-W
    W-BR
    4BR-W
    5-6
    30w-s5s-w31R-BL
    BL-R
    t2 R-O
    ;3O-R
    R-G6G-R
    5-9
    34R-BR9BR-R35R-S
    iI:S-R
    BK-BL11BL-BK37BK-0120-BK
    5-10
    36BK-G13G-BK39BK-BR14BR-BK40BK-S15S-BK41Y-BL16BL-Y
    5-l 142Y-O
    17O-Y
    43Y-G
    16G-Y44Y-BR19BR-Y
    45Y-S
    20S-Y
    5-1246V-BL
    21BL-V
    47v-o
    22o-v46V-G23G-V49V-BR24BR-V
    I:v-sSPAREs-vSPAREConnection/Comments
    (Extension Circuit Feature)
    Page 144 
    						
    All Mitel manuals Comments (0)