    							SECTION MITL8350-047-102-NA 
    Table 3-l (Cont’d), SMarT-1 tm Hardware Specifications 
    SPECIFICATION 
    DIAL TONE 
    CO 
    SIDE FEED: Gain 300 Hz 
    INTERNAL FEED: 350 Hz 
    DTMF RECEIVER 
    LEVEL 
    LEVEL DIFFERENCE 
    FREQ: To receive 
    To not receive 
    DURATION 
    TIME BETWEEN TONES 
    ROTARY RECEIVER 
    MAKE IMPEDANCE 
    MAKE DURATION 
    BREAK IMPEDANCE 
    BREAK DURATION 
    RATE 
    DTMF SENDER 
    LEVEL 
    FREQUENCY 
    DURATION (Programmable) 
    ROTARY SENDER 
    TIMING (Programmable) 
    TIMING (At 60/40): Make 
    Break 
    RATE (At 60/40) 
    INTERDIGIT PAUSE (Programmable) 
    OPERATING RANGE 
    TEMPERATURE 
    HUMIDITY 
    ALLOWABLE VOLTAGE: connected to any 
    point 
    MIN. 
    -2 
    -20 
    -6 
    -1.5 
    -3.5 
    40 
    30 
    20 
    8 
    20 
    7 
    -8 
    -1.3 
    40 
    40/30 
    35 
    55 
    9.9 
    400 
    0 
    0 
    TYP. 
    0 
    n/a 
    -6 
    60 
    60/40 
    10 
    800 
    MAX. 
    +2 
    +3 
    +6 
    +I.5 
    +3.5 
    700 
    100 
    100 
    20 
    -3 
    +I.3 
    130 
    60/40 
    45 
    65 
    10.1 
    1300 
    55 
    85 
    300 
    UNITS 
    dB 
    darn? 
    dB 
    % 
    % 
    ms 
    ms 
    fi 
    ms 
    KQ 
    ms 
    PPs 
    dBmT 
    % 
    ms 
    ms/ms 
    ms 
    ms 
    PPs 
    ms 
    “C 
    % 
    Volts 
    j+ With reference to 600~ Termination. 
    Page 6  
    						
    							SECTION MITL8350-047-102-NA 
    PARAMETER 
    BAUD RATE: 
    PARITY: 
    BITS PER CHARACTER: 
    BIT EIGHT SENSE: 
    MODE: 
    OPERATION: RS-232 PORT 
    3.02 
    Table 3-2 below contains the specifications for the SMarT-I’” 
    Dialer RS-232 Auxiliary Port. This port may be used for 
    pro- 
    gramming or for SMDR Output. 
    Table 3-2, RS-232 Port Specifications 
    SPECIFICATION 
    110 to 9600 Baud programmable; default 
    = 1200 Baud 
    None 
    Eight bits per character with one stop 
    bit. 
    Space 
    On line. 
    Full duplex mode. 
    ELECTRICAL/MECHANICAL 
    3.03 
    Table 3-3 contains the Electrical and Mechanical specifications 
    for the SMarT-1’” Dialer with PAV. These specifications apply 
    to 
    all models of the Controller (4- or 2-line units) unless otherwise noted. 
    3.04 
    This section does not contain all of the specifications for the 
    Controller at present. Other specifications will be added as they 
    are received. 
    Table 3-3, Electrical/Mechanical Specifications 
    PARAMETER 
    DIMENSIONS: 
    WEIGHT: Dialer 
    Power 
    MOUNTING: 
    POWER: 
    Range: 
    CONNECTIONS: SUPPlY SPECIFICATION 
    7.625” (19.37cm) Wide X 10.625” 
    (26.99cm) H X 1.375” (3.49cm) D 
    2 Ibs (0.907 kg) 
    1 lb (0.453 kg) (Approximately) 
    Wall Mount with Supplied Bracket 
    115 Volts AC, 60 Hz 8 300 mA 
    103.5 to 126.5 VAC 
    Standard RJ31X Network Connections  
    						
    							SECTION MITL8350-047-102-NA 
    3.05 
    The specifications in the Tables above are subject to change 
    without notice. The inclusion of ‘n/a’ for a specific parameter 
    means that the specification is not available at the time of this pub- 
    lication. It will be added at a later date. 
    Page 8  
    						
    							SECTION MITL8350-047-102-NA 
    4. UNPACKING, INSTALLATION AND ORDERING INFORMATION 
    SHIPPING AND RECEIVING 
    4.01 The SMarT-I’” Dialer with PAV is shipped in a single carton that 
    contains the Dialer, the Power Supply, a Wall Mounting Bracket, 
    four RJ31X Cables and appropriate documentation. All of these items 
    are protected within the carton by Styrofoam inserts. 
    Note: Some production units do not require the wall mounting 
    brackets since these units are mounted to a wall by use of 
    keyslots included on the unit case. 
    4.02 In some instances where more than one unit is shipped, a 
    larger carton may be used that would contain five of the small- 
    er cartons. Each of the smaller cartons would contain the items listed 
    in 4.01 above. 
    Unpacking 
    4.03 The procedure below lists steps to take when unpacking the 
    equipment (refer to Figures 4-l and 4-2): 
    1) Open carton and remove contents. 
    2) Check each item removed for damage. 
    3) Check each item against the packing list. 
    4) Notify the vendor if any items are missing or appear to be 
    damaged or defective. 
    Repacking 
    4.04 If an item is found to be defective or damaged and is to be 
    returned to the vendor, it should be tagged and packaged to 
    prevent damage. If units are to be shipped from one location to 
    another, these units should also be packaged in such a manner as to 
    prevent damage. Figure 4-1 shows how the equipment was originally 
    packed. This method of packaging should be followed as closely as 
    possible. 
    4.05 If the original packaging material is no longer available, the 
    returned parts should be wrapped in several layers of air- 
    cushion type of wrap, placed in a suitable container, and surrounded 
    with paper to minimize the movement of the items. 
    INSTALLATION REQUIREMENTS 
    4.06 The SMarT-1’” Dialer is position independent. It may be mount- 
    ed anywhere that will accommodate the unit size as listed in 
    the specifications in Table 3-3 on Page 7. 
    4.07 
    The Dialer will operate within a 0-55°C temperature and a 
    Page g  
    						
    							SECTION MITL8350-047-102-NA 
    RJ31WCA31A 
    CABLES 
    DOCUMENTATIOI 
    DIALER 
    CARDBOARD 
    FLAP DETAIL 
    Figure 4-1, Equipment Unpacking and Repacking 
    Page 10  
    						
    							SECTION MlTL8350-047-102-NA 
    SINGLE UNIT 
    CARTON 
     
     /-- 
    /-- 
     /-- 
     _-- 
    ‘Y--- /-- 
     
     /.-- 
     
    I-  
    MULTI-UNIT 
    CARTON 
    Figure 4-2, Multi-Unit Packing and Repacking 
    Page 11  
    						
    							SECTION MITL8350-047-102-NA 
    O-85% humidity range. 
    POWER REQUIREMENTS 
    The customer must provide a single phase power receptacle 
    with the following recommendations: 
    115V, 60Hz fused and capable of delivering 350mA per unit 
    installed. 
    The power receptacle should be wired and fused independently 
    from all other receptacles that are not controller related. 
    A warning tag should be attached to circuit breaker type fuses 
    to prevent unauthorized manual operation. 
    The power receptacle should not be controlled by a switch. 
    The live and neutral conductors at the receptacle should be 
    wired to their proper respective connections. 
    The power receptacle must be a 3-wire type, with the ground 
    wire connected to the ground of the electrical system. 
    The receptacle should be easily accessible for the removal of 
    the plug for maintenance. 
    The receptacle location should be selected to prevent acciden- 
    tal removal of the power cord. 
    The power cord between the receptacle and the unit should not 
    present a hazard to the user. 
    MOUNTING 
    4.09 If the unit requires the wall mounting bracket, simply mount the 
    bracket to a surface with screws. Mount the Dialer housing to 
    the bracket by matching the four holes on the rear of the case with the 
    mounting pins of the bracket. Press firmly into place. 
    4.10 If the unit is the keyslot type, mount by using the provided 
    template to find screw locations. Insert #6 X 3/4 wood or self- 
    tapping screws in these locations, leaving approximately l/8 inch gap 
    between the surface and the cap-head. Mount the Dialer by positioning 
    the keyslots over the screw heads, pressing toward and then down 
    from the mounting surface. 
    CONNECTIONS 
    Note: The Dialer with PAV should be 
    ing any connections. Refer to 
    initialization procedure. initialized prior to 
    accomplish- 
    Part 6, paragraph 
    6.06 for the 
    4.11 Connections to the Dialer are made at the Connector Panel 
    located along the bottom edge of the housing. Figure 4-l illus- 
    trates the connection panel. The steps below outline the connection 
    procedure: 
    Page 12  
    						
    							SECTION MITL8350-047-102-NA 
    TRUNK 
    CONNECTIONS 
    [Cl / 
    COMPUTER 
    PORT (RS-232) 
    [Dl 
    Figure 4-3, Controller I/O Connections 
    110 
    VAC 
    cl 0 
    0 
    SMART-1 
    CONTROLLER 
    POWER 
    SUPPLY 
    RJ3lX 
    CA31A 
    ’ 1 L__-_______I 
    ‘L______--____-___I I 
    L-,-,___,,__,__,,,,_,,I 
    =n 
    Figure 4-4, Typical Controller Installation Configuration 
    Page 13  
    						
    							, 
    SECTION MlTL8350-047-102-NA 
    CENTRAL 
    OFFICE 
    LINES MDF DF 
    CENTRAL OFFICE ‘SPLIT’ TYPE 
    DEMARC 
    STATION BLOCK 
    i T_ 
    a-_ T 
    _-_ 
    ST 
    --- -- _ 
    - -- 
    SR 
    - -- 
    - -- - 
    - -- _ EQUIPMENT 
    - -- - 
    - -- _ 
    - -- - 
    ‘66 BLOCK BRIDGE BRIDGE 
    OR RJZlX CLIPS CLIPS 1 1 
    RJBlX I I 
    MDF OR CAPlA 
    (T) TIP 
    (R) RING 
    L--l-aI-,ld----J 
    I I I 
    Figure 4-5, Typical Connection Configuration 
    14 20 
    25 
    yrJ SIGNAL 
    1 
    FRAME GND 
    2 
    RxD 
    (Signal in) 
    3 
    TxD (Signal Out) 
    4,5 
    TIED TOGETHER 
    6,8,20 TIED TOGETHER 
    7 GND 
    c 
    Figure 4-6, RS-232 Interface Connector (Viewed from outside Dialer) 
    I 
    Page 14  
    						
    							SECTION MITL8350-047-102-NA 
    1 
    I 
    !- 
    Figure 4-7, USOC RJ3lX Jack and Cable ASSY. 
    Page 15  
    						