Have a look at the manual Vodavi Infinite Dvx Iii Hybrid Key Telephone System Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 60 Vodavi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
PRINTING SYSTEM DATABASE PARAMETERSinfiniteTld DVX I’Digital Key Telephone System System DataBase Parameters (Cont’d) D.Printing CO and Station Port Parameters Programming Steps If CO/Station parameters need to be printed:1. Press the CO/Station Port Parameters flexible button (Button #4). The following message will be shown on the display phone: 2.To print the CO/Station Port parameters,press the HOLD button. The following message will be shown on the display phone: When the system has finished sending the re-quested Information to the printer, conkna- tion tone will be heard.DescriptionWith a printer connected to the RS-232C port (future) on the Central Processor Unit (CPU) orto either Port #3 or Port #4 on the I/O Expan- sion Module, the currently stored customer database can be printed or “uploaded” Into a file. This command allows either a range of station data or all stations dam information to be “dumped” as a permanent record which canserve as a hard copy of the station attribute database .The system Baud rate must match that of the printer or receiving device. 4Refer to the following Figure for an example of a Station attribute database printout. Default: NoneRelated Programming: Refer to Sec. 710.8, Baud Rate Assignments, for setting the baud rate of the RS-232C port on the Central Proces-sor Unit (CPU) (future) on Central Processor Unit (CPU), Port #3 or Port #4 on the I/O Expansion Module. 775-8 Issue 1, February 1994
infrnitem DVX I’ DigitaI Key Telephone System PRINTING SYSTEM DATABASE PARAMETERS CARDco-- 01-01 02 03040506 07080910 1112 02-13 14 15161718 19202122 2324 03-25 26 27282930 31323334 3536 04-37 38 39404142 43444546 4748 CARDSTA- 01-100 101102103 104105106107108109110111 02 -112 113114115116117118 119120121122123 03-124 125126127 128129130131132133134135 04-136 137138139140141142143144145 146147 05-148 149150151 152153154155156157158159 06-160 161162163164165166167168169 170171 07-172 173174175176177178 179180181182183 08-184 185186187188189190191192193 194195Figure 775-4 DB Printout of CO/Station Parameters Issue 1, February 1994 775-9
PRINTING SYSTEM DATABASE PARAMETERSinfinitem DVX I’Digital Key Telephone System System DataBase Printouts (Cont’d) E. Printing Exception Tables Programming Steps If a printout of the Exception tables are desired: 1.Press the EXCEPTTABLES flexible button (Button #5). The following message will beshown on the display phone: 2. To print the Except Tables, press the HOLD button. The following message will be shown on the display phone: When the system has finished sending the re-quested information to the printer, confirma- tion tone will be heard.DescriptionWith a printer connected to the RS-232C port (future) on the Central Processor Unit (CPU) orto either Port #3 or Port #4 on the I/O Expan- sion Module, the currently stored customer database can be printed or “uploaded” into a file. This command allows each exception tableto be printed individually to serve as a perma- nent record which can be saved as a hard copy of the exception table database .The system Baud rate must match that of the printer or receiving device. When printing information from the Exceptiontables, the following data i9 printed: l Allow Table A l Deny Table A l Allow Table B l Deny Table B l SpecialTable 1 l Special Table 2 l Special Table 3 l Special Table 4 Refer to the following Figure for an example of the Exception Tables database printout. Default: NoneRelated Programming: Refer to Sec. 7 10.8, Baud Rate Assignrnents, for setting the baud rate of the RS-232C port on the Central Proces-sor Unit (CPU) (future) on Central Processor Unit (CPU), Port #3 or Port #4 on the I/O Expansion Module. ,: 775- 10Issue 1, February 1994
infznitem DVX I’ Digitd Key Telephone System PRINTING SYSTEM DATABASE PAIWMETERSAllow Table A SPECIAL TABLE 1 AREA CODE 0102 03 04 05 06 07 08 09 10Deny Table A 11 12 13 14 15 16 17 18 1920ALLOWED OFFICE CODES SPECIAL TABLE 2 AREA CODE ALLOWED OFFICE CODES SPECIAL TABLE 3 AREA CODE -___-ALLOWED OFFICE CODES 0106 0207 0308 04 0905 10Allow Table BSPECIAL TABLE 4 HOME AREA CODE ALLOWED OFFICE COD;; 0102 03 04 05 06 07 08 09 10Deny Table B 11 12 13 14 15 16 17 18 1920 0106 0207 0308 04 090510Figure 775-5 DB printout of Exception Tables Issue 1, February 1994 775-l 1
PRINTING SYSTEM DATABASE PARAMETERSinfznitem DVX I’Digital Key Telephone System System DataBase Printouts (Cont’d) F.Printing System Speed Bins Programming Steps If a printout of the System speed dial entries are desired: 1.Press the SYSTEM SPEED flexible button (Button #6). The following message will beshown on the display phone: 2.To print the System Speed bins, press the HOLD button. The following will be shownon the display phone: PRINTINTSISSP,.,,, When the system has finished sending the re-quested information to the printer, confirma- tion tone will be heard.DescriptionWith a printer connected to the RS-232C port (future) on the Central Processor Unit (CPU) orto either Port #3 or Port #4 on the I/O Expan- sion Module, the currently stored customer database can be printed or “uploaded” into a file. This command allows either a range of system speed dial bins or all bins can be “dumped” as a permanent record which can serve as a hard copy of the system speed dial database .The system Baud rate must match that of the printer or receiving device.Refer to the following Figi.& for an example of a System Speed Dial database printout. Default: NoneRelated Programming: Refer to Sec. 710.8, Baud Rate Assignments, for setting the baud rate of the RS-232C port on the Central Proces-sor Unit (CPU) (future) on Central Processor Unit (CPU), Port #3 or Port #4 on the I/O Expansion Module. 775-12Issue 1, February 1994
infinitem DVX I’ Digital Key Telephone System PRINTING SYSTEM DATABASE PARAMETERS SYSTEM SPEED NUMBERS 50 20 51 21 52 22 53 23 54 24 55 25 56 26 57 27 58 28 59 . 29 60 30 61 31 62 32 63 33 64 34 65 35 66 36 67 37 68 38 69 39 70 40 71 41 42 43 44 45 46 47 48 49 . . .and so on thru Speed Numbers 99 Figure 775-6 DB Printout of System Speed Numbers Issue 1, February 1994 775-13
PRINTING SYSTEM DATABASE PARAMETERSinfinitem DVX I’Digital Key Telephone System System DataBase Printouts (Cont’d) G. Printing LCR Tables Programming Steps If a printout of the LCR tables are desired:1. Press the LCR TABLES flexible button (Button #7). The following message will beshown on the display phone: 2.To print the LCRTables, press the HOLD button. The following will be shown on thedisplay phone. When the system has finished sending the re-quested information to the printer, confirrna- tion tone will be heard.DescriptionWith a printer connected to the RS-232C port (future) on the Central Processor Unit (CPU) orto either Port #3 or Port #4 on the I/O Expan- sion Module, the currently stored customer database can be printed or “uploaded” into a file. This command allows each exception tableto be printed individually to serve as a perma- nent record which can be saved as a hard copy of the exception table database .The system Baud rate must match that of the printer or receiving device.When printing information from the LCR Ta- bles, the following data is @inted:l Exception Table l Route List Table l Insert/Delete Table l Daily Time Table l Weekly Time Tablel Toll Tables l 6-Digit Table l 3-Digit Table Refer to the following Figures for examples of the LCR Tables database printout. Default: NoneRelated Programming: Refer to Sec. 710.8, Baud Rate Assignments, for setting the baud rate of the RS-232C port on the Central Proces-sor Unit (CPU) (future) on Central Processor Unit (CPU), Port #3 or Port #4 on the I/O Expansion Module. 775-14 Issue 1, February 1994
infmitem DVX HJDigital Key Telephone System PRINTING SYSTEM DATABASE PARAMETERS EXCEPTION CODE TABLE 32771##1CODEROUTE NO -- 42771##1ROUTE LIST TABLE DIGIT INS/DEL TABLE RT TIME COST CO GRP INS/DEL GRP PR TABLEDIGITS 0 1 0261 2 0261 3 0261 4 026111 0001 2 0001 3 0001 4 00012 1 0101 2 0101 3 0101 4 01013 1 0721 2 0721 3 0721 4 07214 1 1711 2 1711 3 1711 4 17115 1 1061 2 1061 3 1061 4 10616 1 2771 2 2771 ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## ## 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1DAILY START TIME TABLE TABLETIME 1800 21700 32300a4####WEEKLY SCHEDULE TABLE START TIMEMTWTFSS 8001111133 17002 2 2 2 2 3 2 23003 3 3 3 3 3 3 ####3 3 3 3 3 3 3LCR ROUTE FOR 555-1212 ##6 DIGIT TABLE AREA ROUTE OFFICE CODESCODE NO -- Figure 775-7 DB Printout of LCR Tables Issue 1, February 1994 775-15
PRINTING SYSTEM DATABASE PARAMETERSinJinitem DVX I’Digital Key Telephone System 3 DIGIT TABLE 25628N17N 25728N17N CODE LEADING1NON-LEADING12582 8N17NRR PP6RR PP 625928N17N 26028N17N 11 ## ##N6 ## N 26128N17N 200 0 11N## ## N26228N17N 201 0 11N## ## N26328N17N 202 0 11N## ## N26428N17N 203 0 11N## ## N26528N17N 204 3 11N## ## N26628N17N 205 0 11N## ## N 26728N17N 206 0 11N## ## N 26828N17N 207 0 11N## ## N26928N17N 208 0 11N## ## N27028N17N 209 0 11N## ## N27128N17N 210 0 11N## ## N27228N17N 212 0 11N## ## N27328N17N 213 0 11N## ## N 27428N17N 214 0 11N## ## N 27528N17QN215 0 11N## ## N27628N17N 216 0 11N## ## N27728N17N 217 0 11N## ## N 27828N17N 218 0 11N## ## N 27928N17N 219 0 11N## ## N28028N17N 220 2 8N1 7 N 28128N17N 221 2 8N1 7 N28228N17N 222 2 8N1 7 N28328N17N 223 2 8N1 7 N 28428N17N 224 2 8N1 7 N28528N17N 225 2 8N1 7 N 28628N17N 226 2 8N1 7 N 28728N17N 227 2 8N1 7 N 28828N17N 228 2 8N1 7 N 28928N17N 229 2 8N1 7 N 29028N17N 230 2 8N1 7 N 29128N17N 231 2 8N1 7 N29228N17N 232 2 8N1 7 N 29328N17N 233 2 8N1 7 N29428N17N 234 2 8N1 7 N 29528N17N 235 2 8N1 7 N 296 28N17N 236 2 8N1 7 N 29728N17N 237 2 8N1 7 N 298 28N17N 238 2 8N1 7 N 29928N1,..7N 239 2 8N1 7 N 300011N####N 240 2 8N1 7 N301011N####N 241 2 8N1 7 N 302011N####N 242 2 8N1 7 N303011N####N 243 2 8N1 7 N 304011N####N 244 2 8N1 7 N 305011N####N 245 2 8N1 7 N 306311N####N 246 2 8N1 7 N 307011N####N 247 2 8N1 7 N308011N####N 248 2 8N1 7 N 309011N####N 249 2 8N1 7 N310011N####N 250 2 8N1 7 N312011N####N 251 2 8N1 7 N 313011N####N 252 2 8N1 7 N314011N####N 253 2 8N1 7 N315011N####N 254 2 8N1 7 N 316011N####N 255 2 8N1 7 N 317011N####N Figure 775-S DB Printout of LCR Default 775-16 Issue 1, February 1994
infmite~ DVX I’Digital Key Telephone System PRINTING SYSTEM DATABASE PARAMETERS 318011N####N37928N17N319011N####N38028N17N 32028N17N38128N17N32128N17N38228N17N 32228N17N38328N17N32328N17N38428N17N32428N17N38528N17N 32528N17N38628N17N32628N17N38728N17N 32728N17N38828N17N32828N17N38928N17N 32928N17N39028N17N33028N17N39128N17N33128N17N39228N17N 33228N17N39328N17N33328N17N39428N17N 33428N17N39528N17N33528N17N39628N17N33628N17N39728N17N 33728N17N39828Nal7N33828N17N39928N17N 33928N17N400011N####N 34028N17N401011N####N34128N17N402011N####N 34228N17N403311N####N34328N17N404011N####N34428N17N405011N####N 34528N17N406011N####N34628N17N407011N####N34728N17N408011N####N 34828N17N409011N####N34928N17N410011N####N35028N17N41114N13N 35128N17N412011N####N 35228N17N413011N####N35328N17N414011N####N35428N17N415011N####N 35528N17N416311N####N35628N17N417011N####N 35728N17N418311N####N35828N17N419011N####N35928N17N42028N17N36028N17N42128N17N 36128N17N42228N17N36228N17N42328N17N 36328N17N42428N17N36428N17N42528N17N36528N17N42628N17N 36628N17N42728N17N36728N17N42828N17N 36828N17N42928N17N36928N17N43028N17N37028N17N43128N17N 37128N17N43228N17N37228N17N43328N17N 37328N17N43428N17N37428N17N43528N17N37528N17N43628N17N 37628N17N43728N17N37728N17N43828N17N37828N17N43928N17NFigure 775-S DB Printout of LCR Default (Cont’d)Issue 1, February 1994 775-17