Have a look at the manual Vodavi Infinite Dvx Iii Hybrid Key Telephone System Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 60 Vodavi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
M&e TM Diilbl SystemsTF NO: 58 TruM Card (CotIt’d) PROGRAMMING Tl ALARM INFORMATION Press FLASH and dial [47j in the programming mode. The buttons in the FLASH 47 programming mode are as follows: The LCD on the telephone displays the following: Buttons l-7 represent each of the 7 alarm conditions. These alarm settings govern all Tl trunk cards installed in the system. To select a particular alarm press a button (l-7) that represents the alarm condition you wish to Set. The LED lights steady when the button is pressed. The alarms that can be programmed are as follows: Button # 1Carrier LossButton # 5Excessive Bipolar Variations (BPV) Button # 2Blue Alarm Button # 6Slip Button # 3Yellow Alarm Button # 7Data Errors -Button # 4Red Alarm Once the desired alarm is selected, the following conditions can be programmed: Button # 11 Button # 12 Button # 13 Button # 14 Button # 15 Button # 16Enable/Disable the alarm. Clear the alarm Minor threshold setting Major threshold setting Time period for minor/major alarms Send LCD message of major alarms to first attendant station Page 35 of 46TF NO. 58 mmLRahtmMwscdtsw$R65260(Wua-mo
intinite m Digiil SystemsTF NO: 58 Tl TN& Card (Cont’d) For example the procedure for setting all the alarm conditions for Carrier Loss are as follows:Button % ll- ENABLE/DISABLE 1.Press Button # 1, to activate the Carrier Loss alarm. The default condition Button # 11 is also lit and the LCD displays the following message: :/ &km w: : q i::i;:: :.:if:.,:(ii/j: .:::. . :..:,:. ~.:..:i:::. ..:j::.. !*li-:1:..::.:-.-: :::. ,,;;j,,;,,: ,:j .:,,, /1,j:;;::, .:.’ ‘. Where O-l is the range of numbers that can be entered on the dial pad to Enable or Disable the alarm. 2.Enter 0 to disable the alarm, or a 1 to enable it. Enabled is the default. (Enter 0 to disable) 3.Press the HOLD button to confirm the entry. A confirmation tone is heard and the !-CD display is updated.Button # 12-- CLEAR ALARM 1.With Button # 11 still Lit, Press Button # 12 ( Clear Alarm). The LCD displays the following: 2.Press the HOLD button to confirm the entry. A confirmation tone is heard and the display is updated. The alarm is cleared for all Tl trunk cards in the system.Page 36 of 46TF NO. 58 83mrltamlm&atsda$REs26lJ(WIlbam
infinite TM Digital SystemsTF NO: 58 Tl Trunk Card (Cti’d)Button # 13- MINOR ALARM 1.Button # 1 remains lit. Press Button # 13 to enter a value for the alarm. 3.Enter a two-digit value on the dial pad that represents the threshold limit (00-99 Default 15). This value can be set for all the alarms. The alarms where it should be set are EXC BPV, SLIP, or EXC DATA ERRORS.\ 4.Press the HOLD button to confirm the entry. Confirmation tone is heard and the display updates. This threshold is set for all Tl trunk cards in the system.a This value represents a peg count. If the error counter in the Tl trunk software reaches the number programmed in this field within the time entered in the Time Period program, the system reports a minor alarm. Button % 14- MAJOR ALARM 1.Be sure Button # 1 is still Lit. 2.Press Button # 14 to enter a value for the alarm. 3.Enter a two-digit value on the dial pad that represents the threshold limit (00-99 Default = 30). This value can be set for all the alarms. It should be set for EXC BPV, SLIP, or EXC DATA ERRORS. 4.Press the HOLD button to confirm the entry. Confirmation tone is heard and the display updates. This threshold is set for all Tl trunk cards in the system. This value represents a peg count. If the error counter in the Tl trunk software reaches the number programmed irrthis field within the time entered in the Time Period program, the system reports a major alarm.Page 37 of 46TF NO. 58 83ooE.RahmMueL3cats&R65260WW-QI)o
int7nite Tb4 Dii*tal SystemsTF NO: 58 Tl Trudc Card (Cont’d) Button # 15 TIME PERIOD 1.Press Flexible Button #l. 2..Press Button # 15 to enter a value for the alarm. 3.Enter a two-digit value on the dial pad that represents the time period limit (00-99 minutes). This value can be set for all the alarms. It should be set for EXC BPV, SLIP, or EXC DATA ERRORS. 4.Press the HOLD button to confirm the entry. Confirmation tone is heard and the display updates. This time period is set for all Tl trunk cards in the system. Button # 16-- ATTENDANT STATION 1.Press Flexible Buttons # 1. 2.Enter 0 (Disable) or 1 (Enable) on the dial pad to disable or enable the alarm. d”/ 3.Press the HOLD button to confirm the entry. A confirmation tone is heard and the LCD display is updated. The attendant clears the display by dialing the code [606]. General Procedure to Program Alarm Conditions Button # ll- ENABLE/DISABLE (ANY ALARM) 1.Press the desired alarm button. (Buttons 1 through 7). 2.Enter 0 (Disable) or 1 (Enable) on the dial pad to disable or enable the alarm. - e”’Where XXXXXXXXX is the alarm name (ie: CARRIER LOSS, RED ALARM, BLUE ALARM, YELLOW ALARM, EXC BPV, SLIP, or EXC DATA ERRORS.) 3.Press the HOLD button to confirm the entry. A confirmation tone is heard and the LCD display is updated. Page 38 of 46TF NO. 58 83ooLlialwthiw~k85260WI-~
infinite m Digiil SystemsTF NO: 58 Tl Trudc Card (Co&d)Button W 12- CLEAR ALARM (ANY ALARM) 1.Press the desired alarm button. ( Buttons 1 through 7). 2.Press Button # 12 to clear or disable the alarm. The LCD displays the following message: Where XXXXXXXXX is the alarm name (i.e. CARRIER LOSS, RED ALARM, BLUE ALARM, YELLOW ALARM, EXC BPV, SLIP, or EXC DATA ERRORS). , 3.Press the HOLD button to confirm the entry. A confirmation tone is heard and the display is updated. The alarm is cleared for all Tl trunk cards in the system..Button # 13-- MINOR ALARM (ANY ALARM) 1.Press the desired alarm button. Only Buttons 5-7 can be set for a threshold. 2.Press Button # 13 to enter a value for the alarm. 3.Enter a two-digit value on the dial pad that represents the threshold limit (00-99). Where XXXXXXXXX is the name of the alarm. This value can be set for all the alarms. It should be set for EXC BPV, SLIP, or EXC DATA ERRORS. 4.Press the HOLD button to confirm the entry. Confirmation tone is heard and the display updates. This threshold is set for all Tl trunk cards in the system. This value represents a peg count. if the error counter in the Tl card trunk software reaches the number programmed in this field within the time entered in the Time Period program, the system reports a minor alarm.Page 39 of 46TF NO. 58 MwrRshtltemsamdi&R85260WI-~
hfmite TM Digiil SystemsTF NO: 58 Tl Tank Card (Cont’d)Button % 14- MAJOR ALARM (ANY ALARM) 1.Press the desired alarm button (5-7). 2. Press Button # 14 to enter a value for the alarm. 3.Enter a twodigit value on the dial pad that represents the threshold limit (00-99).Where XXXXXXXXXX is the alarm name. This value can be set for all the alarms. It should be set for EXC BPV, SLIP, or EXC DATA ERRORS. 4.Press the HOLD button to confirm the entry. Confirmation tone is heard and the display updates. This threshold is set for all Tl trunk cards in the system.._ This value represents a peg count. If the error counter in the Tl card trunk software reaches the number programmed in this field within the time entered in the Time Period program, the system reports a major alarm.Button # 15- TIME PERIOD (ANY ALARM) 1.Press the desired alarm button (5-7). 2.Press Button # 15 to enter a value for the alarm. 3.Enter a two-digit value on the dial pad that represents the time period limit (00-99 minutes). This value can be set for all the alarms. It should be set for EXC BPV, SLIP, or EXC DATA ERRORS.. 4.Press the HOLD button to confirm the entry. Confirmation tone is heard and the display updates. This time period is set for all Tl lines in the system.Page 40 of 46TF NO. 58
inl7nife TM Digital SystemsTF NO: 58 Tl Tnvlk Card (Cor#d)Button # 16.. AlTENDANT DISPLAY (ANY ALARM) 1.Press the desired alarm button. (Buttons 1 through 7). 2.Enter 0 (Disable) or 1 (Enable) on the dial pad to disable or enable the alarm. ‘.: .:.::.:g &i’ ~::,.:: :...:::; ‘..‘. ./ : Where XXXXXXXXX is the alarm name (ie: CARR!ER LOSS, RED ALARM, BLUE ALARM, YELLOW ALARM, EXC BPV, SLIP, or EXC DATA ERRORS.) 3.Press the HOLD button to confirm the entry. A confirmation tone is heard and thf LCD display is updated. The attendant can clear the display by dialing the code [606].Page 41 of 46TF NO. 58 83alLRmMlwllrivekottdrs,ka526clww--
hWte TM Digiil SystemsTF NO: 58 Tl Tndc Card (Cont’d) Inttialiiation of Tl System Parameters Descr#bn: This section describes the procedures and steps necessary to initialize the system database returning any programmed data to its original or default value. The entire system database may be initialized or various portions of the database may be individually initialized. In addition to initialization of the entire database, a system reset (Button ##20) command can also be used. The buttons on the digital terminal are defined as shown below when entering the Initialization DataBase Parameters programming area: Programming: 1.Press FLASH and dial [80]. The following message is shown on the display phone: iNlTIALlZE DATA-BASEENTER 8UTTON NUMBER’e 2.Press the System Parameters Button (Button # 1). The following message will be shown on the display phone: ~INITIALIZE SYSTEM PABAM PRESS,HOLD.I.. 3.To initialize the Tl System Parameters, including Tl Alarm Settings press the HOLD button. Confirmation tone will be heard. Page 42 of 46TF NO. 58 83ooLlwmm~kW26U(802)-=
iniinife m Diiltal SystemsTF NO: 58 Tl Truh Card (Cont’d) Prhthg of Tl System Parameters: Desaipii: This section describes the procedures and steps necessary to print Data Base Parameters and various p(#Ons of the system. A complete description of these instructions is included in Section 775 of the infinite DVX Digital Telephone System-- General Description, Installation and Maintenance Manual. With a printer connected to the RS-232C port (Port #3) on the Backplane I/O Expansion Module, the currently stored customer database can be printed or “downloaded” into a file. This command allows the entire database to be “dumped” as a permanent record which can serve as a hard copy of the database. The system Baud rate must match that of the printer or receiving device. Default: Nonea Related Programmhg: Refer to Sec. 710.10, Baud Rate Aignments for setting the baud rate of the RS-232C port on the Backplane I/O Expansion Module on theDVX??Isystem.._ The buttons on the key telephone as shown below when entering the Print Data Base Parameters programming area. Programm’hg: 1.Press FLASH and dial [85]. The following message displays on the phone LCD: Page 43 of 46TF NO. 58
inGnite TM Digital SystemsTF NO: 58 I Tl Trunk Card (Cont’d) For a printout of the Tl System Parameters: PlogramButtonWl: To obtain a printout of the programmed Tl alarms in the system, use the System database printout function (Flash 85, Button #l). 1.Check to see that Button # 1 is lit. 2.Press the HOLD button. The following message displays on the phone LCD: /pnlM ’ 4 When the system finishes sending the information to the printer, confirmation tone is heard. The following is a sample report of the Tl Alarm Settings.. 3.ALARM DESCRIPTION ALARM CARRIER LOSS Y BLUE ALARM Y YELLOW ALARM Y RED ALARM YBIPOLAR VARIATIONS Y SLIP ALARM Y DATA ERRORSYPERIODTHRESHOLDATTENDANT MINOR MAJOR DISPLAY 1530Y 1530Y1530Y 1530Y1530Y1530Y1530YPage 44 of 46TF NO. 58 8woLkammetlamc@Rw260VW--