Have a look at the manual Vodavi Infinite Dvx Iii Hybrid Key Telephone System Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 60 Vodavi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
INITIALIZE DATABASE PARAMETERSinfinite” DVX I’Digital Key Telephone System INIT. DATABASE PARAMET ERS (Cont’d) M. Initialize VM Group Parameters Programming Steps If VM Group Parameters need to be initialized:1. Press the VM Group Parameters flexible button (Button #13). The following mes- sage will be shown on the display phone:Description VM Group parameters maybe initialized setting all data fields to their original, default values.2. To initialize the VM Group parameters, press the HOLD button. Confirmation tone will be heard.4PROGRAM CODE ~WITON~1 FLASH 651 FLEX 1 FEATUREDEFAULT VALUE-(after initializing)I 1-8 I Vnire Mail CT-mlps 4&)-447No Voice Mail groups are establishedI- -. ---- _._-L ULVCFLASH 66 9Alternate VM Group AssignNo Alternate VM groupassignment is made 10 Leave TableNo outpulsing table is referenced 11 12l-7 Retrieve Table VM Station Assignments Voice Mail Out-Pulsing Tablesfor in-band signalingNo outpulsing table isreferenced NO stations are assignedOut-pulse tables are empty by default FLASH 67 8 Voice Mail Disconnect Table Disconnect table is empty 1In-Band Digits for Incoming co CalIsDisabled by default 2 Voice Mail Transfer/ForwardDisabled by default 770-1s Issue 1, February 1994
infinite” DVX I’Digital Key Telephone System INITIALIZJ3 DATABASE PARAMETERS INIT. DATABASE PARAMET ERS (Cont’d) N. System Reset Programming StepsIf the system needs to be reset but not initial- ized:1. Press the RESET flexible button (Button #20). The following message will be shownon the display phone: Description This feature provides a hard system reset from the keyset instead of the KSU. This is useful incases where miscellaneous data errors have occurred and the system needs to be reset without initializing the entire database. 2.To reset the system without initializing thedatabase, press the HOLD button. No Confirmation tone will be heard and the system will now reset.Issue 1, February 1994 770-19
infznitem DVX I’ Digital Key Telephone SystemSECTION 775 775.1TABLE OF CONTENTS FOR SECTION 775 PRINTING SYSTEM DATABASE PARAMETERS.........................775- 1INTRODUCTION.................................................................................... 775- 1A. Printing System Parameters...................................................... .775-2 B.Printing CO Line Attributes........................................................775-4 C.Printing Station Attributes.........................................................775-6D. Printing CO and Station Port Parameters.................................. .775-8E. Printing Exception Tables........................................................ 775- 10F. Printing System Speed Bins.....................................................775-12 G. Printing LCR Tables.................................................................775-14 H. Printing Entire System Data Base............................................775-23 I.Printing ICLID Tables...............................................................775-24 J.Printing Directory Dialing Table Parameters.......i.....................775-27 K. Printing Hunt Group Parameters..............................................775-29 L.Printing ACD or UCD Group Parameters..................................775-3 1 M.Printing Voice Mail Group Parameters......................................775-33 N. Abort Printing..........................................................................775-35 Issue 1, February 1994775-i
infznite” DVX I’Digital Key Telephone System PRINTING SYSTEM DATABASE PARAMETERS SECTION 775PRINTING SYSTEM DATABASE PARAJUETERS 775.1INTRODUCTION Program.ming Steps If the system is in the programming mode, continue using the program codes. If starting toprogram here, enter the programming mode. Refer to Sec. 700.2, Program Mode Entry (Key Station). If DataBase Parameters need to be printed: 1.Press FLASH and dial [85]. The following will be shown on the display phone: 2.Choose the portion of the database to be printed by pressing the appropriate but- ton in the flexible button field.DescriptionThis section describes the procedures and steps necessary to print Data Base Parameters and various portions of the system.The buttons on the key telephone are defined as shown below when entering the Print Data Base Parameters programming area. * Features available with optional software.With a printer connected to the RS232C port (future) on the Central Processor Unit (CPU) orto either Port #3 or Port #4 on the I/O Expan- sion Module, the currently stored customer database can be printed or “uploaded” into a file. This command allows the entire databaseto be “dumped” as a permanent record which can serve as a hard copy of the database .The system Baud rate must match that of the printer or receiving device.Refer to the following Figures for examples of the database printouts. Also refer to the follow- ing paragraphs for instructions on printing onlyportions of the database . Default: NoneRelated Programming: Refer to Sec. 710.8, Baud Rate Assignments, for setting the baud rate of the RS-232C port (future) on Central Processor Unit (CPU), Port #3 or Port #4 on the I/O Expansion Module. Issue 1, February 1994 775-l
System DataBase Printouts (Cont’d) A Printing System Parameters Programming StepsDescription If a printout of all System Parameters is desired: 1.Press the SYSTEM PARAMETERS flexible button (Button # 1). The following messagewill be shown on the display phone:With a printer connected to the RS-232C port (future) on the Central Processor Unit (CPU) orto either Port #3 or Port #4 on the I/O Expan- sion Module, the currently stored customer database can be printed or “uploaded” into a file. This command allows the System Parame-ters database to be “dumped” as a permanent record which can serve as a hard copy.The system Baud rate must match that of the printer or receiving device. When printing the System Parameters the fol- lowing data is printed; l All System Timersal All System wide options (i.e. external night ringing, Hold preference etc.. .)l Attendant programming l Other system assignments (i.e. Page/Relay Assignments, Execu- tive/Secretary, SMDR etc. ..)l Weekly Night Mode schedule Refer to the following Figure for an example of the system parameters database printout. Default: None 2.To print the system parameter database ,press the HOLD button. The following message will be shown on the display phone: When the system has finished sending the in- formation to the printer, confirmation tone will be heard.System Timers: SHR= System Hold Recall Timer EHR= Exclusive Hold Recall Timer ART= Attendant Recall Timer XFR= Transfer Recall Timer PFT= Preset Forward Timer CFN= Call Forward No-Answer Timer PT= Pause Timer CPT= Call Park Timer CFT= Conference Timer PTO= Page Timeout Timer COT= CO Ring Detect Timer SRT= Single Line Receiver Timer MWT= Message Wait Reminder Tone IdIT= Hook Flash Timer HFD= Hookswitch Bounce Timer CQT= SMDR Call Qualification Timer ACB= Auto Call Back Timer RR= Reminder Ring Timer RG= Release Guard TimerRelated Programmiug: Refer to Sec. 710.8, Baud Rate Assignments, for setting the baud rate of the RS-232C port on the Central Proces-sor Unit (CPU) (future) on Central Processor Unit (CPU), Port #3 or Port #4 on the I/O Expansion Module. System Features: AO=Attendant Override SY= Hold PreferenceENR= External Night Ringing EO=Exec Override Warn Tone PW= Page Warning ToneBGM= Background Music LCR= LCR Enable/Disable AC=Forced Account Codes GL=Group Listening S=Idle Speaker Mode CC= Call Cost Display FeatureMH= Music On Hold V= Handset Receiver Gain Q= Call Qualification Tone Option 775-2 Issue 1, February 1994
infkiteTM DVX I’Digital Key Telephone System PRINTING SYSTEM DATABASE PARAMETERS SYSTEM PARAMETERS Eng. Ver. 2.3D-0FFFSYSTEM TIMERS -SHR EHR ART XFR PFT CFN PT 60180 14510152CPT CFT PTO COT SRT MWT HFT 1801015320010HFD CQT ACB RR RG 10 300 0 3 SYSTEM FEATURES A0 SY ENR EO PW BGM LCR N Y NYYY N AC GL S CC MH V Q N NN N YNN BARGE IN WARN TONE ENABLED SYSTEM LED FLASH RATES INC CO RING30 IPM FLASH INC ICM RING120 IPM FLUTTER CALL FORWARD 30 IPM FLASH MESSAGE WAITING15 IPM FLASH ATTENDANT STATIONS 100 ### ### DATE & TIME FORMATMM/DD/YY, 12 HOURS PBX DIALING CODES ## ## ## ## ## EXECUTIVE/SECRETARY PAIRINGS l=######2=######3=######4=######RELAY ASSIGNMENTS ON BOARD RELAY 1NONE2NONE3NONE 4NONE5NONE 6NONE7NONE RELAY/SENSOR ### 1NONE2NONE 3NONE4NONE5NONE 6NONERELAY/SENSOR ### 1NONE2NONE3NONE 4NONE5NONE 6NONE RELAY/SENSOR ### 1NONE2NONE 3NONE4NONE5NONE 6NONE RELAY/SENSOR ### 1NONE2NONE3NONE 4NONEa5NONE 6NONE I/O BAUD RATE ~- Port1/On Board=2400Port2/Modem=1200Port3/RS232=2400 Port 4/RS422=2400 ACCESS CODE 1 DISA ACCESS 1002 ADMIN PASSWORD 3226 SDR TPE PNT BAUD PORT NLD 802400 1 AUTO NIGHT MODEN WEEKLY NIGHT MODE SCHEDULE -ENDSTART DAYTIMETIME M 008001700 Tl08001700 w 208001700 T 308001700 F 408001700 s 5 ######## S 6######## DIAL PULSE RATIOSPEED 6040 1OPPSSYSTEM SLOT TYPE ssssccccssss Figure 775-l DB Printout of System Parameters Issue 1, February 1994 775-3
PRINTING SYSTEM DATABASE PARAMETERSin$initem DVX I’Digital Key Telephone System System DataBase Printouts (Cont’d) B.Printing CO Line Attributes Programming Steps If a printout of the CO Line Attributes is desired:1. Press the CO LINE ATTRIBUTES flexible button (Button #2). The following message will be shown on the display phone: 2.To print the data for ALL CO Lines, press the HOLD button. To print CO Line data for a specified CO Line Range enter four digits to specify the CO Line range (two digits for the first line within the range and two digits for the last line in the range i.e. [0115]). If a printout of only one line is desired enter that line twice (i.e. [OlOl]).Then press the HOLD button. 3. The following message will be shown on the display phone and the CO Line data will be printed: When the system has finished sending the re-quested information to the printer, confirma- tion tone will be heard.DescriptionWith a printer connected to the RS-232C port (future) on the Central Processor Unit (CPU) orto either Port #3 or Port #4 on the I/O Expan- sion Module, the currently stored customer database can be printed or “uploaded” into a file. This command allows either a range of COLines or the entire CO Line database to be “dumped” as a permanent record which can serve as a hard copy of the CO Line attribute database .The system Baud rate must match that of the printer or receiving device.When printing the CO Lint attributes the fol- lowing data is printed:l All CO Line parameters within the specified range. 0CO Line ringing assignments within the specified range.l Dial Pulse Ratio and Speed settings Refer to the following Figure for an example of the CO Line attribute database printout. Default: NoneRelated Programming: Refer to Sec. 710.8, Baud Rate Assignments, for setting the baud rate of the RS-232C port on the Central Proces-sor Unit (CPU) (future) on Central Processor Unit (CPU), Port #3 or Port #4 on the I/O Expansion Module. Definition of Terms for CO Lines Printout SIGNAL= DTMF/Dial Pulse ?YPE= CO/PBX UNA= Universal Night Answer PRI= CO Line Privacy SUPV= Loop Supervision DISA= Direct Inward System Access FLTM= Flash TimerGRP= CO Line Group COS= CO Line Class of Service DIR= Trunk Direction RD= Ring Delay Timer775-4Issue 1, February 1994
infinitem DVX I’ Digital Key Telephone System PRINTING SYSTEM DATABASE PARAMETERS CO LINE ATTRIBUTES co 01 LINE 01 SIGNAL TYPE UNA CONF PRI DTMF CO YY Y SUPV DISA FLTM GRP COS DIR RD NN10 1 1 2 00 RING ASSIGNMENTS 100Bco 02 LINE 02 SIGNAL TYPE UNA CONF PRI DTMF CO YY Y SUPV DISA FLTM GRP COS DIR RD NN10 1 1 2 00 RING ASSIGNMENTS 100Bco 03co 05 -- LINE 05 SIGNAL TYPE UNA CONF PRI DTMF CO YY Y SUPV DISA FLTM GRP COS DIR RD NN10 1 12 00 RING ASSIGNMENTS 100BCO 06 LINE 06 SIGNAL TYPE UNA CONF PRI DTMF CO YY Y SUPV DISA FLTM GRP C& DIR RD NN10 1 12 00 RING ASSIGNMENTS 100Bco 07 LINE 07 LINE 03 SIGNAL TYPE UNA CONF PRI DTMF CO YY Y SUPV DISA FLTM GRP COS DIR RD NN10 1 1 2 00 RING ASSIGNMENTS 10OBco 04 LINE 04 SIGNAL TYPE UNA CONF PRI DTMF CO YY Y SUPV DISA FLTM GRP COS DIR RD NN10 1 12 00 RING ASSIGNMENTS 100BSIGNAL TYPE UNA CONF PRI DTMF CO YY Y SUPV DISA FLTM GRP COS DIR RD NN10 1 12 00 RING ASSIGNMENTS 100BCO 08 -- LINE 08 SIGNAL TYPE UNA CONF PRI DTMF CO YY Y SUPV DISA FLTM GRP COS DIR RD NN 10 1 12 00 RING ASSIGNMENTS 100B . . .and so on thru CO Lines 48 Figure 775-2 DB Printout of CO Line Attributes Issue 1, February 1994775-5
PRINTING SYSTEM DATABASE PARAMETERSinfinitem DVX I’Digital Key Telephone System System DataBase Printouts (Cont’d) C. Printing Station Attributes Programming Steps If a printout of the Station Attributes is desired:1. Press the STATION ATTRIBUTES flexible button (Button #3). The following messagewill be shown on the display phone: jPRINT STATIONS 2. To print data for all stations, press the HOLD button. To print Station data for a specified Station Range enter six digits to specify the Station range (three digits for the first station within the range and three digits for the last station in the range i.e. [ 1001091). If a printout of only one stationis desired enter that station twice (i.e. [lo1 1011). Then press the HOLD button.3. The following message will be shown on the display phone and the requested infor- mation will be printed: ,,,,,,,,,,,,,, When the system has finished sending the re-quested information to the printer, confirma- tion tone will be heard. PaPe “A” Features: PAGE= Paging Access DND= Do Not Disturb CONF= Conference EOR=Executive Override PRI= Privacy SPD= System Speed Dial Access QUE= Line Queue Access PLA= Preferred Line AnswerOHVO=Off-Hook Voice Over FWD= Station Call Forward Access LCR= LCR Class of ServiceSUB= ACD Supervisor Monitor Barge-m REM= CO Line Ringing Options DescriptionWith a printer connected to the RS-232C port (future) on the Central Processor Unit (CPU) orto either Port #3 or Port #4 on the I/O Expan- sion Module, the currently stored customer database can be printed or “uploaded” into a file. This command allows either a range of station data or all stations data information to be “dumped” as a permanent record which canserve as a hard copy of the station attribute database .The system Baud rate must match that of the printer or receiving device. When printing the Station attributes the follow- ing data is printed;l All current station parameters Refer to the following Figure for an example of a Station attribute database printout. Default: NoneRelated Programming: Refer to Sec. 710.8, Baud Rate Assignments, for setting the baud rate of the RS-232C port on the Central Proces-sor Unit (CPU) (future) on Central Processor Unit (CPU), Port #3 or Port #4 on the I/O Expansion Module. Pee “B” Features: SID= Station IDAID= Associated ID (DSS/DIS Console) DCOS= Day Class of Service NCOS= Night Class of ServiceSPK= Speakerphone Option PICKUP= Pickup Groups PAGE= Paging Groups PREFWD= Preset Forward Assignment LCOS=LCR Class of ServiceBUTTONS= Refer to Table 730-2 Flexible Button Display Designations, Page 730-24.775-6 Issue 1, February 1994
in$initew DVX I’ Digitd Key Telephone System PRINTING SYSTEM DATABASE PARAMETERS STATION ATTRIBUTES STA 102 STA 100 PAGE DND CONF EOR PRI SPD QUEY Y YN/A Y Y Y PLA OHVO FWD LCR SUB REM NN Y N N N SID AID DCOS NCOS SPK 0110PICKUP PAGE PREFWD LCOS 110 CO ACCESS 1 BUTTONS OlDlOO 02D101 03D102 04D103 05D104 06D10507D106 08D107 09DlO8lODlO9 llDll0 12Dlll 13COOl 14COO2 15COO316COO4 17COO5 18COO6 19LP2OPLl21CBK 22FWD23DND 24CNF PRIME KEY 0 Y STA 101 PAGE DND CONF EOR PRI SPD QUEY Y YN/A Y Y Y PLA OHVO FWD LCR SUB REM NN Y N N N SID AID DCOS NCOS SPK 0110PICKUP PAGE PREFWD LCOS110 CO ACCESS 1 BUTTONS OlDlOO 02D101 03D102 04D103 05D104 06D10507D106 08D107 09D108 lOD109 llCOO1 12CO0213coo3 14coo4-15coo516COO6 17coo7 18COO8 19LP2OPLl21CPO22LQU23CBK 24PKU 25MSG 26FWD 27DND 28CNFPRIME KEY 0 Y PAGE DND CONF EOR PRI SPD QUEY Y YN/A Y Y Y PLA OHVO FWD LCR SUB REM NN Y N N N SID AID DCOS NCOS SPK0110 PICKUP PAGE PREFWD LCOS110 CO ACCESS 1 BUTTONS OlDlOO 02DlOl 03D10204D103 05D104 06D105 07D106 08D107 09D108lOD109 11COOl 12COO2 13coo3 14coo4 15coo516COO6 17coo7 18COO819LP2OPLl21CPO I 22LQU 23CBK 24PKU 25MSG 26FWD27DND 28CNFPRIME KEY 0 Y STA 103 PAGE DND CONF EOR PRI SPD QUEY Y YN/A Y Y Y PLA OHVO FWD LCR SUB REMN N Y N N N SID AID DCOS NCOS SPK0110 PICKUP PAGE PREFWD LCOS110 CO ACCESS 1 BUTTONS OlDlOO 02D101 03D10204D103 05D104 06D10507D106 08D107 09D108 lOD109 11COOl 12COO213coo3 14coo4 15coo5 16COO6 17coo7 18COO819LP2OPLl21CPO 22LQU23CBK 24PKU 25MSG 26FWD27DND 28CNFPRIME KEY 0 Y and so on thru stations 195Figure 775-3 DB Printout of Station Attributes Issue 1, February 1994775-7