    Have a look at the manual Vodavi Infinite Dvx Iii Hybrid Key Telephone System Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 60 Vodavi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 609
    							INITIALIZE DATABASE PARAMETERSinfinite” DVX I’Digital Key Telephone System
    INIT. DATABASE PARAMET
    ERS (Cont’d)
    M. Initialize VM Group Parameters
    Programming Steps
    If VM Group Parameters need to be initialized:1. Press the VM Group Parameters flexible
    button (Button 
    #13). The following mes-
    sage will be shown on the display phone:Description
    VM Group parameters maybe initialized setting
    all data fields to their original, default values.2. To initialize the VM Group parameters,
    press the HOLD button. Confirmation
    tone will be heard.4PROGRAM CODE
    ~WITON~1  FLASH 651  FLEX 1
    FEATUREDEFAULT VALUE-(after initializing)I 1-8 I
    Vnire Mail CT-mlps 4&)-447No Voice Mail groups are
    establishedI- -. ---- _._-L ULVCFLASH 66
    9Alternate VM Group AssignNo Alternate VM groupassignment is made
    10
    Leave TableNo outpulsing table is
    referenced
    11
    12l-7
    Retrieve Table
    VM Station Assignments
    Voice Mail Out-Pulsing Tablesfor in-band signalingNo outpulsing table isreferenced
    NO stations are assignedOut-pulse tables are empty
    by default
    FLASH 67
    8
    Voice Mail Disconnect Table
    Disconnect table is empty
    1In-Band Digits for Incoming
    co CalIsDisabled by default
    2
    Voice Mail Transfer/ForwardDisabled by default
    770-1s
    Issue 1, February 1994 
    						
    							infinite” DVX I’Digital Key Telephone System
    INITIALIZJ3 DATABASE PARAMETERS
    INIT. DATABASE PARAMET
    ERS (Cont’d)
    N. System Reset
    Programming StepsIf the system needs to be reset but not 
    initial-
    ized:1. Press the 
    RESET flexible button (Button
    #20). The following message will be shownon the display phone:
    Description
    This feature provides a hard system reset from
    the 
    keyset instead of the KSU. This is useful incases where miscellaneous data errors have
    occurred and the system needs to be reset
    without initializing the entire database.
    2.To reset the system without initializing thedatabase, press the HOLD button. No
    Confirmation tone will be heard and the
    system will now reset.Issue 1, February 1994
    770-19 
    						
    							infznitem DVX I’
    Digital Key Telephone SystemSECTION 775
    775.1TABLE OF CONTENTS FOR SECTION 775
    PRINTING SYSTEM DATABASE PARAMETERS.........................775- 
    1INTRODUCTION....................................................................................
    775- 1A. Printing System Parameters......................................................
    .775-2
    B.Printing CO Line Attributes........................................................775-4
    C.Printing Station Attributes.........................................................775-6D. Printing CO and Station Port Parameters..................................
    .775-8E. Printing Exception Tables........................................................
    775- 10F. Printing System Speed Bins.....................................................775-12
    G. Printing LCR Tables.................................................................775-14
    H. Printing Entire System Data Base............................................775-23
    I.Printing ICLID Tables...............................................................775-24
    J.Printing Directory Dialing Table Parameters.......i.....................775-27
    K. Printing Hunt Group Parameters..............................................775-29
    L.Printing ACD or UCD Group Parameters..................................775-3 1
    M.Printing Voice Mail Group Parameters......................................775-33
    N. Abort Printing..........................................................................775-35
    Issue 1, February 1994775-i 
    						
    							infznite” DVX I’Digital Key Telephone System
    PRINTING SYSTEM DATABASE PARAMETERS
    SECTION 775PRINTING SYSTEM DATABASE 
    PARAJUETERS
    775.1INTRODUCTION
    Program.ming Steps
    If the system is in the programming mode,
    continue using the program codes. If starting toprogram here, enter the programming mode.
    Refer to Sec. 700.2, Program Mode Entry (Key
    Station).
    If 
    DataBase Parameters need to be printed:
    1.Press FLASH and dial [85]. The following
    will be shown on the display phone:
    2.Choose the portion of the database to be
    printed by pressing the appropriate but-
    ton in the flexible button field.DescriptionThis section describes the procedures and
    steps necessary to print Data Base Parameters
    and various portions of the system.The buttons on the key telephone are defined
    as shown below when entering the Print Data
    Base Parameters programming area.
    * Features available with optional software.With a printer connected to the 
    RS232C port
    (future) on the Central Processor Unit (CPU) orto either Port 
    #3 or Port #4 on the I/O Expan-
    sion Module, the currently stored customer
    database can be printed or “uploaded” into a
    file. This command allows the entire databaseto be “dumped” as a permanent record which
    can serve as a hard copy of the database .The system Baud rate must match that of the
    printer or receiving device.Refer to the following Figures for examples of
    the database printouts. Also refer to the follow-
    ing paragraphs for instructions on printing onlyportions of the database .
    Default: NoneRelated Programming: Refer to Sec. 710.8,
    Baud Rate Assignments, for setting the baud
    rate of the RS-232C port (future) on Central
    Processor Unit (CPU), Port 
    #3 or Port #4 on the
    I/O Expansion Module.
    Issue 1, February 1994
    775-l 
    						
    							System DataBase Printouts (Cont’d)
    A Printing System Parameters
    Programming StepsDescription
    If a printout of all System Parameters is desired:
    1.Press the SYSTEM PARAMETERS flexible
    button (Button # 1). The following messagewill be shown on the display phone:With a printer connected to the RS-232C port
    (future) on the Central Processor Unit (CPU) orto either Port 
    #3 or Port #4 on the I/O Expan-
    sion Module, the currently stored customer
    database can be printed or “uploaded” into a
    file. This command allows the System Parame-ters database to be “dumped” as a permanent
    record which can serve as a hard copy.The system Baud rate must match that of the
    printer or receiving device.
    When printing the System Parameters the fol-
    lowing data is printed;
    l All System Timersal All System wide options (i.e. external
    night ringing, Hold preference etc.. .)l Attendant programming
    l Other system assignments (i.e.
    Page/Relay Assignments, Execu-
    tive/Secretary, SMDR etc. ..)l Weekly Night Mode schedule
    Refer to the following Figure for an example of
    the system parameters database printout.
    Default: None
    2.To print the system parameter database ,press the HOLD button. The following
    message will be shown on the display
    phone:
    When the system has finished sending the in-
    formation to the printer, confirmation tone will
    be heard.System Timers:
    SHR= System Hold Recall Timer
    EHR= Exclusive Hold Recall Timer
    ART= Attendant Recall Timer
    XFR= Transfer Recall Timer
    PFT= Preset Forward Timer
    CFN= Call Forward No-Answer Timer
    PT= Pause Timer
    CPT= Call Park Timer
    CFT= Conference Timer
    PTO= Page Timeout Timer
    COT= CO Ring Detect Timer
    SRT= Single Line Receiver Timer
    MWT= Message Wait Reminder Tone
    IdIT= Hook Flash Timer
    HFD= Hookswitch Bounce Timer
    CQT= SMDR Call Qualification Timer
    ACB= Auto Call Back Timer
    RR= Reminder Ring Timer
    RG= Release Guard TimerRelated 
    Programmiug: Refer to Sec. 710.8,
    Baud Rate Assignments, for setting the baud
    rate of the RS-232C port on the Central Proces-sor Unit (CPU) (future) on Central Processor
    Unit (CPU), Port 
    #3 or Port #4 on the I/O
    Expansion Module.
    System Features:
    AO=Attendant Override
    SY= Hold PreferenceENR= External Night Ringing
    EO=Exec Override Warn Tone
    PW= Page Warning ToneBGM= Background Music
    LCR= LCR Enable/Disable
    AC=Forced Account Codes
    GL=Group Listening
    S=Idle Speaker Mode
    CC= Call Cost Display FeatureMH= Music On Hold
    V= Handset Receiver Gain
    Q= Call Qualification Tone Option
    775-2
    Issue 1, February 1994 
    						
    							infkiteTM DVX I’Digital Key Telephone System
    PRINTING SYSTEM DATABASE PARAMETERS
    SYSTEM PARAMETERS
    Eng. Ver.
    2.3D-0FFFSYSTEM TIMERS
    -SHR EHR ART XFR PFT CFN PT
    60180
    14510152CPT CFT PTO COT SRT MWT HFT
    1801015320010HFD CQT ACB RR RG
    10 300 0 3
    SYSTEM FEATURES
    A0 SY ENR EO PW BGM LCR
    N Y NYYY N
    AC GL S CC 
    MH V Q
    N NN N YNN
    BARGE IN WARN TONE ENABLED
    SYSTEM LED FLASH RATES
    INC CO RING30 IPM FLASH
    INC ICM RING120 IPM FLUTTER
    CALL FORWARD
    30 IPM FLASH
    MESSAGE WAITING15 IPM FLASH
    ATTENDANT STATIONS
    100 ### ###
    DATE 
    & TIME FORMATMM/DD/YY, 12 HOURS
    PBX DIALING CODES
    ## ## ## ## ##
    EXECUTIVE/SECRETARY PAIRINGS
    l=######2=######3=######4=######RELAY ASSIGNMENTS
    ON BOARD RELAY
    1NONE2NONE3NONE
    4NONE5NONE
    6NONE7NONE
    RELAY/SENSOR ###
    1NONE2NONE
    3NONE4NONE5NONE
    6NONERELAY/SENSOR ###
    1NONE2NONE3NONE
    4NONE5NONE
    6NONE
    RELAY/SENSOR ###
    1NONE2NONE
    3NONE4NONE5NONE
    6NONE
    RELAY/SENSOR ###
    1NONE2NONE3NONE
    4NONEa5NONE
    6NONE
    I/O BAUD RATE
    ~-
    Port1/On Board=2400Port2/Modem=1200Port3/RS232=2400
    Port
    4/RS422=2400
    ACCESS CODE
    1 DISA ACCESS
    1002 ADMIN PASSWORD
    3226
    SDR TPE PNT BAUD PORT
    NLD 802400 1
    AUTO NIGHT MODEN
    WEEKLY NIGHT MODE SCHEDULE
    -ENDSTART
    DAYTIMETIME
    M 008001700
    Tl08001700
    w 208001700
    T 308001700
    F 408001700
    s 5
    ########
    S 6########
    DIAL PULSE
    RATIOSPEED
    6040
    1OPPSSYSTEM SLOT TYPE
    ssssccccssss
    Figure 775-l DB Printout of System Parameters
    Issue 1, February 1994
    775-3 
    						
    							PRINTING SYSTEM DATABASE PARAMETERSin$initem DVX I’Digital Key Telephone System
    System 
    DataBase Printouts (Cont’d)
    B.Printing CO Line Attributes
    Programming Steps
    If a printout of the CO Line Attributes is desired:1. Press the CO LINE ATTRIBUTES flexible
    button (Button #2). The following message
    will be shown on the display phone:
    2.To print the data for ALL CO Lines, press
    the HOLD button. To print CO Line data
    for a specified CO Line Range enter four
    digits to specify the CO Line range (two
    digits for the first line within the range and
    two digits for the last line in the range i.e.
    [0115]). If a printout of only one line is
    desired enter that line twice (i.e. [OlOl]).Then press the HOLD button.
    3. The following message will be shown on
    the display phone and the CO Line data
    will be printed:
    When the system has finished sending the re-quested information to the printer, confirma-
    tion tone will be heard.DescriptionWith a printer connected to the RS-232C port
    (future) on the Central Processor Unit (CPU) orto either Port 
    #3 or Port #4 on the I/O Expan-
    sion Module, the currently stored customer
    database can be printed or “uploaded” into a
    file. This command allows either a range of COLines or the entire CO Line database to be
    “dumped” as a permanent record which can
    serve as a hard copy of the CO Line attribute
    database .The system Baud rate must match that of the
    printer or receiving device.When printing the CO 
    Lint attributes the fol-
    lowing data is printed:l All CO Line parameters within the
    specified range.
    0CO Line ringing assignments within the
    specified range.l Dial Pulse Ratio and Speed settings
    Refer to the following Figure for an example of
    the CO Line attribute database printout.
    Default: NoneRelated Programming: Refer to Sec. 710.8,
    Baud Rate Assignments, for setting the baud
    rate of the RS-232C port on the Central Proces-sor Unit (CPU) (future) on Central Processor
    Unit (CPU), Port 
    #3 or Port #4 on the I/O
    Expansion Module.
    Definition of Terms for CO Lines Printout
    SIGNAL= DTMF/Dial Pulse
    ?YPE= CO/PBX
    UNA= Universal Night Answer
    PRI= CO Line Privacy
    SUPV= Loop Supervision
    DISA= Direct Inward System Access
    FLTM= Flash TimerGRP= CO Line Group
    COS= CO Line Class of Service
    DIR= Trunk Direction
    RD= Ring Delay Timer775-4Issue 1, February 1994 
    						
    							infinitem DVX I’
    Digital Key Telephone System
    PRINTING SYSTEM DATABASE PARAMETERS
    CO LINE ATTRIBUTES
    co 01
    LINE 01
    SIGNAL TYPE UNA CONF PRI
    DTMF CO YY Y
    SUPV DISA FLTM GRP COS DIR RD
    NN10 1 1 2 00
    RING ASSIGNMENTS
    100Bco 02
    LINE 02
    SIGNAL TYPE UNA CONF PRI
    DTMF CO YY Y
    SUPV DISA FLTM GRP COS DIR RD
    NN10 1 1 2 00
    RING ASSIGNMENTS
    100Bco 03co 05
    --
    LINE 05
    SIGNAL TYPE UNA CONF PRI
    DTMF CO YY Y
    SUPV DISA FLTM GRP COS DIR RD
    NN10 1 12 00
    RING ASSIGNMENTS
    100BCO 06
    LINE 06
    SIGNAL TYPE UNA CONF PRI
    DTMF CO YY Y
    SUPV DISA FLTM GRP 
    C& DIR RD
    NN10 1 12 00
    RING ASSIGNMENTS
    100Bco 07
    LINE 07
    LINE 03
    SIGNAL TYPE UNA CONF PRI
    DTMF CO YY Y
    SUPV DISA FLTM GRP COS DIR RD
    NN10 1 1 2 00
    RING ASSIGNMENTS
    10OBco 04
    LINE 04
    SIGNAL TYPE UNA CONF PRI
    DTMF CO YY Y
    SUPV DISA FLTM GRP COS DIR RD
    NN10 1 12 00
    RING ASSIGNMENTS
    100BSIGNAL TYPE UNA CONF PRI
    DTMF CO YY Y
    SUPV DISA FLTM GRP COS DIR RD
    NN10 1 12 00
    RING ASSIGNMENTS
    100BCO 08
    --
    LINE 08
    SIGNAL TYPE UNA CONF PRI
    DTMF CO YY Y
    SUPV DISA FLTM GRP COS DIR RD
    NN
    10 1 12 00
    RING ASSIGNMENTS
    100B
    . . .and so on thru CO Lines 48
    Figure 775-2 DB Printout of CO Line Attributes
    Issue 1, February 1994775-5 
    						
    							PRINTING SYSTEM DATABASE PARAMETERSinfinitem DVX I’Digital Key Telephone System
    System 
    DataBase Printouts (Cont’d)
    C. Printing Station Attributes
    Programming Steps
    If a printout of the Station Attributes is desired:1. Press the 
    STATION ATTRIBUTES flexible
    button (Button #3). The following messagewill be shown on the display phone:
    jPRINT STATIONS
    2. To print data for all stations, press the
    HOLD button. To print Station data for a
    specified Station Range enter six digits to
    specify the Station range (three digits for
    the first station within the range and three
    digits for the last station in the range i.e.
    [ 1001091). If a printout of only one stationis desired enter that station twice (i.e.
    [lo1 1011). Then press the HOLD button.3. The following message will be shown on
    the display phone and the requested infor-
    mation will be printed:
    ,,,,,,,,,,,,,,
    When the system has finished sending the re-quested information to the printer, confirma-
    tion tone will be heard.
    PaPe “A” Features:
    PAGE= Paging Access
    DND= Do Not Disturb
    CONF= Conference
    EOR=Executive Override
    PRI= Privacy
    SPD= System Speed Dial Access
    QUE= Line Queue Access
    PLA= Preferred Line AnswerOHVO=Off-Hook Voice Over
    FWD= Station Call Forward Access
    LCR= LCR Class of ServiceSUB= ACD Supervisor Monitor Barge-m
    REM= CO Line Ringing Options
    DescriptionWith a printer connected to the RS-232C port
    (future) on the Central Processor Unit (CPU) orto either Port 
    #3 or Port #4 on the I/O Expan-
    sion Module, the currently stored customer
    database can be printed or “uploaded” into a
    file. This command allows either a range of
    station data or all stations data information to
    be “dumped” as a permanent record which canserve as a hard copy of the station attribute
    database .The system Baud rate must match that of the
    printer or receiving device.
    When printing the Station attributes the follow-
    ing data is printed;l All current station parameters
    Refer to the following Figure for an example of
    a Station attribute database printout.
    Default: NoneRelated Programming: Refer to Sec. 710.8,
    Baud Rate Assignments, for setting the baud
    rate of the RS-232C port on the Central Proces-sor Unit (CPU) (future) on Central Processor
    Unit (CPU), Port 
    #3 or Port #4 on the I/O
    Expansion Module.
    Pee “B” Features:
    SID= Station IDAID= Associated ID 
    (DSS/DIS Console)
    DCOS= Day Class of Service
    NCOS= Night Class of ServiceSPK= Speakerphone Option
    PICKUP= Pickup Groups
    PAGE= Paging Groups
    PREFWD= Preset Forward Assignment
    LCOS=LCR Class of ServiceBUTTONS= Refer to Table 730-2 Flexible
    Button Display Designations, Page 
    730-24.775-6
    Issue 1, February 1994 
    						
    							in$initew DVX I’
    Digitd Key Telephone System
    PRINTING SYSTEM DATABASE PARAMETERS
    STATION ATTRIBUTES
    STA 102
    STA 100
    PAGE DND CONF EOR PRI SPD QUEY Y YN/A Y Y Y
    PLA OHVO FWD LCR SUB REM
    NN Y N N N
    SID AID DCOS NCOS SPK
    0110PICKUP PAGE PREFWD LCOS
    110
    CO ACCESS 1
    BUTTONS
    OlDlOO 02D101 03D102
    04D103 05D104 06D10507D106 08D107 09DlO8lODlO9 llDll0 12Dlll
    13COOl 14COO2 15COO316COO4 17COO5 18COO6
    19LP2OPLl21CBK
    22FWD23DND 24CNF
    PRIME KEY 0 Y
    STA 101
    PAGE DND CONF EOR PRI SPD QUEY Y YN/A Y Y Y
    PLA OHVO FWD LCR SUB REM
    NN Y N N N
    SID AID DCOS NCOS SPK
    0110PICKUP PAGE PREFWD LCOS110
    CO ACCESS 1
    BUTTONS
    OlDlOO 02D101 03D102
    04D103 05D104 06D10507D106 08D107 09D108
    lOD109 llCOO1 12CO0213coo3 14coo4-15coo516COO6 17coo7 18COO8
    19LP2OPLl21CPO22LQU23CBK 24PKU
    25MSG 26FWD 27DND
    28CNFPRIME KEY 0 Y
    PAGE DND CONF EOR PRI SPD QUEY Y YN/A Y Y Y
    PLA OHVO FWD LCR SUB REM
    NN Y N N N
    SID AID DCOS NCOS SPK0110
    PICKUP PAGE PREFWD LCOS110
    CO ACCESS 1
    BUTTONS
    OlDlOO 02DlOl 03D10204D103 05D104 06D105
    07D106 08D107 09D108lOD109 11COOl 12COO2
    13coo3 14coo4 15coo516COO6 17coo7 18COO819LP2OPLl21CPO I
    22LQU 23CBK 24PKU
    25MSG 
    26FWD27DND
    28CNFPRIME KEY 0 Y
    STA 103
    PAGE DND CONF EOR PRI SPD QUEY Y YN/A Y Y Y
    PLA OHVO FWD LCR SUB REMN
    N Y N N N
    SID AID DCOS NCOS SPK0110
    PICKUP PAGE PREFWD LCOS110
    CO ACCESS 1
    BUTTONS
    OlDlOO 02D101 03D10204D103 05D104 06D10507D106 08D107 09D108
    lOD109 11COOl 12COO213coo3 14coo4 15coo5
    16COO6 17coo7 18COO819LP2OPLl21CPO
    22LQU23CBK 24PKU
    25MSG 
    26FWD27DND
    28CNFPRIME KEY 0 Y
    and so on thru stations 195Figure 
    775-3 DB Printout of Station Attributes
    Issue 1, February 1994775-7 
    						