REMOTE ADMIN & MAINT PROCEDURES SECTION 200-096-600 FEBRUARY 1991 TABLE RM-F PROGRAM 92 (continued) LCD CHARACTER MESSAGE MEMORY INITIALIZATION iTEP ACTION DISPLAY/PRINTOUT 1 Enter Program Mode >MODE PROG At the >MODE prompt, enter 4 B w H q . 2 Enter Program Number 92 P 92 Press [9 P92 3 Enter m . P92 P92 3 4 Enter key number 1 1. P92 P92 3 02 N 5 Change 02 key to “ON” by entering 1 P92 P92 3 02 N Y 6 Press m . P92 P92 3 02 N Y 03 N 7 Change key 03 to “ON” by entering 1 P92 P92 3 02 N Y 03 N Y 8 Press [9 . P92 Initialization complete. P92 3 02 N Y NOTE: If program data is not entered correctly, q will 03 N Y not respond. To retry, press m q P92 . 9 Clear the timed reminders using the procedure on the next page. . -_j : -14-
REMOTE AOMIN 81 MAINT PROCEDURES SECTION 200-096-600 FEBRUARY 1991 TABLE RM-G PROGRAM 92 (continued) TIMED REMINDERS INITIALIZATION ;TEP ACTION DISPLAY/PRINTOUT 1 Enter Program Mode >MODE PROG At the >MODE prompt, enter i B m 1 q . 2 Enter Pro ram Number 92 d P 92 Press - P92 3 Enter1 . P92 P92 4 4 Enter key number 11 P92 P92 4 02 N 5 Change key 02 to “ON” by entering [ . P92 P92 4 02 N Y 6 Press m two times. P92 P92 4 02 N Y 03 N 04 N 7 Change key 04 to “ON” by P92 entering [ . P92 4 02 N Y 03 N 04 N Y 8 Press q P92 Initialization complete. P92 4 02 N Y NOTE: If program data is not entered correctly, q will 03 N not respond. To retry, press m q 04 N Y . P92 9 To exit this program, press 11 q . -15-
REMOTEADMlN&MAlNTPROCEDURES SECTION 200-096-600 FEBRUARY1991 STEP/ TABLERM-Gl PROGRAM 92(continued) DlGlTALTELEPHONEVOLUMELEVELlNlTlALlZATlON . ACTION DISPLAY/PRINTOUT 1 Enter Program Mode >MODE PROG At the >MODE prompt, enter w B 1 H q . P 2 Enter Program Number 92 P 92 Press q . P92 3 Enter 1 . P92 5 4 Enter q ; change key 01 to “ON” by entering a. P92 5 01 N Y 5 Press m four times. P92 5 01 N Y 02 N 03 N 04 N 05 N 6 Change key 05 to “ON” by entering 1. P92 5 01 N Y 02 N 03 N NOTE: If program data is not entered correctly, [9 will not 04 N respond. To retry, press ),11131=1 q . 05 N Y 7 Press q . P92 5 01 N Y Initialization complete. 02 N 03 N 04 N 05 N P92 8 To exit this program, press m B (9. , -16-
REMOTE ADMIN & MAINT PROCEDURES SECTION 200-096-600 FEBRUARY 1991 TABLE RM-GP PROGRAM 92 (continued) CALL FORWARD BACKUP RAM INITIALIZATION STEP ACTION DISPLAY/PRINTOUT 1 Enter Program Mode >MODE PROG At the S-MODE prompt, enter 1 1 m @ q 2 P 92 P92 I I 3 Enter1 . P92 P92 9 4 Enter key number 11 . P92 P92 9 03 N 5 Change key 03 to “ON” by P92 entering B . P92 9 03 N Y 1 I 6 Press m . P92 P92 9 03 N Y 04 N 7 I I Change key 04 to “ON” by P92 entering 1 . P92 9 03 N Y 04 N Y 8 Press q P92 Initialization complete. P92 9 03 N Y I I NOTE: If program data is not entered correctly, q will not respond. To retry, press m q . 04 N Y P92 9 To exit this program, press [[m . IMPORTANT NOTE: This program clears call forward memory for all stations, but does not reset the call forward indication on the station (call forward LCD information and/or call forward button/LED), To clear station call forward indications, system power must be turned OFF for five seconds, then ON. Fixed call forward is not cleared by this program. -16A-
REMOTEAOMIN & MAINTPROCEDURES SECTION 200-096-600 FEBRUARY1991 TABLERM-H TYPEIPROGRAMPROCEDUREEXAMPLE (PROGRAMS: IO-I, 10-2, 1 O-3, 15-0, 15-1, 16,42-O, 77-1,77-2) . STEP/ ACTION DISPLAY/PRINTOUT 1 Enter Program Mode >MODE PROG 0 At the >MODE prompt, enter B 1 m @ q . P 2 Enter Program Number P 10 Refer to the record sheet and enter the desired Example: Program IO-I, enter 0 1, press d rogram number. PlO - . Enter Program Code or Digit(s) Per Record Sheet 3 El or other digit required. PlO 1 NOTE: Most programs do not require a second digit. 4 Enter Key/LED Number PlO 1 01 g (see note) Enter the desired key/LED number. I Example: Key/LED 01, enter 1 n . 5 To Change Key/LED Status Pl0 1 01 N Y Refer to the System Record Sheet and change the key/LED status, if required (Y or N). Example: Enter 1 6 To Advance to Next Key/LED PlO 1 01 Y Press m Repeat step 5 if necessary. 02 N 7 To Review Key/LED Status Change Enter q . PlO 1 01 Y- Key LED “ON” - Re-enter steps 3 and 4. Key LED Number Program Code NOTE: This step is optional and not required to save data. LL Program Number 8 To Exit Program/Store Data PlO A) To store data, press q B) To exit this program, press 1 1, then press q . PlO ## P C) Continue returning to step 2 until all Type 1 programs are completed. 9 To Exit the Program Mode > MODE Pressu[m . IO To Enter Another Mode Press mmmim (datadump) OlMiW (test) m 0 H H q (LCD messages) moii[9 (speed dial) NOTE: Y = key/LED “ON’: N = key/LED “OFF” D T (no prompt) R -16B-
REMOTE ADMIN & MAINT PROCEDURES SECTION 200-096-600 FEBRUARY 1991 TABLE RM-I TYPE 2 PROGRAM PROCEDURE EXAMPLE . ,81 - 89) DISPLAY/PRINTOUT >MODE PROG P I (PROGRAMS: 17,20,30,31,35,40,41,43, i ACTION iTEF 1 Enter Program Mode At the >MODE prompt, enter 4 1 m 1 q . Enter Program Number Refer to the record sheet and enter the desired program number. Example: Program 30, enter1 m, press q . Enter Port Number 0 0 or Port Range 0 0 10 0 Refer to the System Record Sheet and enter the desired port number(s). Example: 1 1. Press i key. 2 P 30 3 P30 P30 04 4 P30 04# 5 Enter the Desired Key/LED Number Example: Key/LED 01, enter: 1 0. P30 04# 01 N_ (Note iIf 6 To Change Key/LED Status Refer to the System Record Sheet and change the key/LED status, if required (Y or N). Example: Enter a P30 04# 01 N Y 7 To Advance to Next Key/LED Press m (repeat step 6 if necessary). 8 To Review Key/LED Status Change Press q Re-enter steps 3, 4, and 5. 9 To Exit Program/Store Data A) To store data, press q B) To exit this program, press 1 1, then press q . C) Continue returning to step 2 until all Type 2 programs are completed. >MODE To Exit the Program Mode Press aim 11 To Enter Another Mode, Press NImlm (datadump) OINIm (test) ~~~~~ (LCD messages) ~~~~~ (speed dial) D T (no prompt) R VOTE: Y = key/LED(s) “ON”, N = key/LED(s) “OFF”; U = key/LED(s) ‘0N”some parts and ‘OFF” other parts, -17-
REMOTEADMlN&MAlNTPROCEDURES SECTION 200-096-600 FEBRUARY1991 TABLERM-J PROGRAM00 SOFTWARECHECK/REMOTEMAINTENANCE-SECURITYCODE . TEP ACTION DISPLAY/PRINTOUT ’ Enter Program Mode >MODE PROG At the >MODE prompt, enter NlH H[9 . P 2 Enter Program Number 00 I? 00 Press q . PO0 3 To Check Software Version PO0 0 Version = Do 00 Enter Action Code 0. System will display the version of software POO that is in the PCTU(S). PCTU type Press q Software version 4 To Change Level 1 Security Code PO0 1 0000 Enter Action Code 1. The system will display the present PO0 level 1, 4-digit code. Refer to the System Record Sheet and change if required. Press (9 . 5 To Change Level 2 Security Code PO0 2 0000 Enter Action Code 2. The system will display the present PO0 level 2, 4-digit code. Refer to the System Record Sheet and change if required. Press q . 6 To Exit This Program Press 1 1 q . PO0 ## P -18-
REMOTEADMlN&MAlNTPROCEDURES SECTlON200-096-600 FEBRUARY1991 TABLERM-K PROGRAM03 FLEXIBLEPCBSLOTASSIGNMENTS ;TEP ACTION DISPLAY/PRINTOUT 1 Enter the Program Mode >MODE PROG At the >MODE prompt, enter w 1 m 1 (9. P 2 Enter Program Number 03 P 03 Press q . PO3 3 Enter the Slot Number PO3 Refer to the System Record Sheet and enter the desired PO3 00 91 slot number. Example: Slot number 00, enter 1 1. 4 Enter the PCB Code Number PO3 Refer to the System Record Sheet and enter the desired PO3 00 91 92 PCB code number. Example: PCB code 92, enter 1 1 . 5 To Exit Program/Store Data PO3 A) To store data, press q . PO3 00 91 92 B) Continue returning to step 3 until all Program 03 PO3 ## data is entered. P C) To exit this program, press 1 1, press q 6 Turn system power “OFF” for 5 seconds and then turn Remote maintenance is disconnected. power “ON” to store data in working memory (see Notes). IMPORTANT NOTES: 1. This program must be completed with on-site assistance (after installing PCBs) because the system must be powered down momentarily after PCB code entry. 2. Even though PCB codes display as being changed, they are not entered into working memory until the system DC power is cycled OFF and ON. 3, If PCB codes are not entered into working memory by cycling DC power, PCB options will not function. 4. Only Program 03 requires the system power to be turned OFF and ON to store data into working memory. -19-
REMOTEAOMlN&MAlNTPROCEOURES SECTION 200-096-600 FEBRUARY1991 TABLERM-L PROGRAM04 PORT/STATIONNUMBERASSlGNMENT ;TEP ACTION DISPLAY/PRINTOUT 1 Enter the Program Mode >MODE PROG At the >MODE prompt enter i m @ H q P 2 Enter Program Number 04 P 04 Press q . PO4 3 Enter the Port Number PO4 Refer to the System Record Sheet and enter the desired PO4 01 port number. Example: Port number 01, enter a 0. 4 Press 1 key. PO4 System displays present station number. Refer to the PO4 Ol# 201 206 System Record Sheet and enter the desired station number. Example: Station number 206, enter 1 1 1. 5 To Exit Program/Store Data PO4 A) To store data; press q PO4 ## B) Continue returning to step 3 until all Program 04 P data is entered. C) To exit this program, press fl 1 [9 . NOTE: A blank is displayed by ‘N”. TABLERM-M PROGRAM05 FLEXIBLEACCESSCOOENUMBERING iTEP ACTION DISPLAY/PRINTOUT 1 Enter the Program Mode >MODE PROG At the >MODE prompt, enter i 0 u H q . 2 Enter Program Number 05 P 05 Press q PO5 3 Enter Access Code number that you wish to change (0 - 9) PO5 4 4 Example: 4 (if it was not previously changed, the system will print another 4. If it has been previously changed, the system will print the number to which it was changed). 4 Change the number if required (one or two digits) PO5 4 4 6 Example: Change to 6, press q 5 Continue returning to step 3 until all required access codeshavebeenchanged. 6 To Exit this Program P Press 1 1 q . , NOTE: Program 10, use Type I procedure. -2o-
REMOTEADMlN&MAlNTPROCEDURES SECTION 200-096-600 FEBRUARY1991 TABLERM-N PROGRAM12 SYSTEM ASSIGNMENTS-BASICTIMING ;TEP ACTION DISPLAY/PRINTOUT 1 Enter the Program Mode >MODE PROG At the >MODE prompt, enter w m B 1 q . P 2 Enter Program Number 12 P 12 Press q . P12 3 Check the record sheet and enter the program code that is P12 3 1 required. As an example, feature 3, enter 1. The present selection will be displayed. 4 Refer to the record sheet and change if required. P12 3 1 2 As an example, change it to 2. Enter 1 . 5 To Exit Program/Store Data P12 A) To store data, press q . p12 # # B) Continue returning to step 3 until all Program 12 data is P entered. C) To exit this program, press 1 1 q TABLERM-0 PROGRAM13 DEFININGTHEMESSAGECENTER STEP ACTION DISPLAY/PRINTOUT 1 Enter the Program Mode >MODE PROG At the >MODE prompt, enter 1 1 1 H q . P 2 Enter Program Number 13 P 13 Press q . P13 3 Enter the number a . The present port number will be displayed. P13 P13 1 NN 4 Refer to the record sheet and enter the required port number. P13 1 NN 00 Example: Port 00, enter 1 1 q . P13 5 To Exit this Program P13 ## Press B 1 q . P NOTES: 1. A blank is displayed by ‘N”. 2. Programs 15, 16, use Type 1 procedure. Program 77, use Type 2 procedure. -21-