    							INSTALLATION-WIRING DIAGRAMS 
    SECTION 200-096-209 
    FEBRUARY 1991 
    TABLE 9-B 
    STATION LOOP REQUIREMENTS 
    Device Description 
    PEKU 
    (ckts 1 - 8) Electronic 
    P%JZ telephone, 
    door phone/ 
    control boxes 
    (ckts 5 - 8) 
    PEKU 
    (ckts 7 & 8) DSS consoles 
    Max Loop Resistance 
    Max Distance from 
    (Including Device) 
    KSU to Device 
    40 ohms 1000 ft. (303 m) 
    20 ohms 
    500 ft. (152 m) 
    Number of 
    Wire Pairs 1 
    All need 2-pair. 
    EKTs which 
    receive OCA 
    calls need 
    3-pair.’ 
    PSTU Standard 
    Approx. 3000 ft. (909 m) 
    (ckts 1 - 8) telephones, with 150 ohm device. See 
    P&U * voice mail, 300 ohms 
    manufacturer’s product 
    auto attendant, 
    specifications for exact 
    (ckts 1 & 2) 
    etc. resistance of device. 
    PDKU Digital 
    (ckts 1 - 8) telephones 40 ohms 
    1000 ft. (303 m) 
    PDKU 
    (ckt 8) DDSS consoles 40 ohms 
    1000 ft. (303 m) 
    PDKU 
    (ckts 1 - 7) PDIU-DI 40 ohms 
    1000 ft. (303 m) 
    PDKU 
    (ckts 1 - 7) PDIU-DS 40 ohms 1000 ft. (303 m) 
    NOTES: 
    1. Use 24 A WG twisted pairs. 
    2. PESU circuits 3 and 4 are not used. 
    3. Two-pair or larger wire is required to achieve maximum range, see table 9-D. 
    1 -pair 
    1 -pair 
    1 -pair 
    Shares digital 
    telephone 
    wire-pair? 
    1 -pair3 
    TABLE 9-C 
    NETWORK REQUIREMENTS 
    I 
    TOSHIBA  TOSHIBA 
    Printed Circuit Board  Printed Circuit Board 
    I 
    Pcou/Pcou2  Pcou/Pcou2 
    (Loop Start Line)  (Loop Start Line) 
    PEMU  PEMU 
    (Type I, TIE Line)  (Type I, TIE Line) 
    2-wire  2-wire 
    4-wire  4-wire 
    PESU*/PSTU/PSTU2 
    (Off-premises 
    Station) 02LS2 
    RJ14C 0.2B 
    TLIlM 
    RJ2EX N/A 
    TL31 M 
    RJ2GX N/A 
    OL13A RJ21 X 
    N/A 
    I 
    *Circuits 1 and 2 Facility 
    Interface Code Ringer 
    Equivalence 
    9-2  
    						
    							INSTALLATION-WIRING DIAGRAMS 
    SECTION 200-096-209 
    FEBRUARY 1991 
    TABLE 9-D 
    DIGITAL TELEPHONE/DIU/DDSS CONSOLE/LOOP LIMITS . 
    PPSU 1 OOOft (303m) 1 OOOft (303m) 
    DDSSI 060A 
    Battery Backup 500ft (151m) 1 OOOft (303m) 
    *Battery backup applies to instances when the system is being powered 
    by batteries exclusively. 
    9-2A  
    						
    							INSTALLATION-WIRING DIAGRAMS 
    SECTION 200-096-209 
    FEBRUARY1991 
    This page is intentionally blank. 
    9-2B  
    						
    							INSTALLATION-WIRING DIAGRAMS 
    SECTION 200-096-209 
    FEBRUARY1991 
    BUILDING #l BUILDING #2 
    TELEPHONE 
    &I Secondary protectors 
    PEMU  PEMU 
    PCOU  PCOU 
    1 I E&M TIE LINE 
    CO LINE 
    HtiUHt Y-A-StWNDARY PROTECTOR DIAGRAM 
    IMPORTANT! 
    To protect against transient voltages and currents, secondary protectors must be installed if 
    there is outside wiring (Figure 9-A). These protectors, which contain fast semiconductors in 
    addtion to fuses, shall comply with the requirements forsecondarypro tectors for communica tion 
    circuits, UL 497A. As of October I, 1990, the following manufacturers offer secondary 
    protectors that are UL listed. 
    9-2c  
    						
    							INSTALLATION-WIRING DIAGRAMS 
    SECTION 200-096-209 
    FEBRUARY1991 
    1. Certron Corp; Anaheim, California 92807 
    l Secondary protector: Model 08450. 
    2. Curtis Mfg. Co. lnc; Jaffrey, New Hampshire 03452 
    l Secondary protector: Model Diamond Chip. For indoor use on the protected side of the 
    telephone circuit only. 
    3. Oneac Corp; Libertyville, Illinois 60048 
    l Secondary protector: Model OnLine 614+ and OnLine DG/S. For indoor use on the 
    protected side of primary telephone protector only. 
    4. Siemon Co.; Watertown, Connecticut 06795 
    l Secondary protector for communication circuits: Model PM-2305. Intended for use with 
    Listed Siemon 66Ml Block: Models PG-04, -25, -50, or PK-04 ground kit and Listed Type 
    I enclosure. For use on the protected side of a Listed Primary Telecommunications 
    Protector for indoor use only. 
    5, Simplex Time Recorder Co.; Gardner, Massachusetts 07440 
    l Isolated loop circuit protectors: Models 2081-9027 and 2081-9028. Intended for use 
    between data communication equipment or signal lines of building system equipment. 
    Install and test the secondary protectors per the installation instructions of the applicable 
    manufacturer. 
    9-2D  
    						
    							INSTALLATION-WIRING DIAGRAMS 
    SECTION 200-096-209 
    FEBRUARY 1991 
    TO P 
    C EKU W/FEMALE 
    :ONNECTOR BRIDGING 
    VOICE Tl 
    DATA Ti 
    DATA RI 
    =+r CIRCUIT 4  1 654321 
    R1  OCA 
    Rl  STATION CABLE 
    TWISTED PAIR  1 PAIR 
    IG 
    CIRCUIT 5 
    NOTE: See Program 28 
    for electronic telephone 
    CIRCUIT 6 to DSS assignments. 
    VOICE PAIR-NOT USED 
    CIRCUIT 7 
    DATA TIP 7 
    DATA RING 7) 
    I TELEPHONE 
    IR-NOT USED ASSOCIATED 
    WITH DSS/BLF ‘ATION 
    CIRCUIT 3 ELECTRONIC 
    TELEPHONE 
    CIRCUIT 4 RECEIVES 
    OFF-HOOK CALLS 
    NOTE: Place 
    PEKlJ SW1 to DSS. 
    GN-Y 1 18 - 
    &; 
    LY-BR ! 44 ; 
    k BR-V ! 24 ; 
    NOTE: See Program 27 to assign DSS buttons. loop resistance: 20 ohms 
    from PEKU to DSS (500 ft). 
    DSS/BLF CONSOLE 
    FIGURE 9-2 
    MDF WIRING/DSS/BLF CONSOLE AND ASSOCIATED ELECTRONIC TELEPHONE WIRING TO PEKU 
    9-4  
    						
    							INSTALLATION-WIRING DIAGRAMS 
    SECTION 200-096-209 
    FEBRUARY1991 
    TO PEKU OR PESU 
    W/FEMALE CONNECTOR BR’DG’NG 
    /-I InP 
    66M150 SPLIT BLOCK ’ CIRCUIT 5 
    CIRCUIT 6 
    CIRCUIT 7 
    CIRCUIT 8 
    NOT USED SCREW 
    1654321 u uuun I I l”lYL n 
    MDFB (REAR VIEW) 
    ( , ; 4 , / lDOO$--1 
    I VR VT 
    MDFB 
    DOOR 
    PHONE B 
    OR DOOR 
    LOCK 
    CONTROL 
    I I 
    I 
    See Note I l J 
    See Note 2 
    1 MDFB (DOOR PHONE) STATION #s 
    See Note 3 
    NOTES: 
    26 1 161 1 162 1 163 
    1. On PEKU or PESU, cut W9. See Programs 39, 
    77-I. 77-2, and 79. 
    2. HDCB “B” output options: 
    SWI: Always in DOOR position. 
    SW2: DOOR position; “B” connects to door phone. 
    LOCK (Release 2 only) position; 
    “B” connects to door lock. 
    3. Door phones may be connected to circuit 5 on 
    ports 4, 12,20 and 28 only. 
    I 
    FlGURE9-3-MOFWIRING-DOOR PHONE/LOCKTO PEKU/PESU 
    9-5  
    						
    							INSTALLATION-WIRING DIAGRAMS 
    SECTION 200-096-209 
    FEBRUARY 1991 
    TO PEKU W/FEMALE 
    ‘CONNECTOR BRIDGING STATION CABLING (24 AWG, TWISTED PAIRS) 
    VOICE Tl (VT) 
    1 VOICE RI (VR) 
    DATA Tl (DT) 
    DATA Rl (DR) 
    J TO ELECTRONIC TELEPHONE 1 
    (PORT 00) 
    CIRCUIT 2 TO ELECTRONIC 
    TELEPHONE (PORT 01) 
    I. 
    Available with R2 software only. 
    BACKGROUND MUSIC 
    \,R9 l!=mRT n3 - 
    SOURCE OUTPUT 
    (600 OHMS; 1 V RMS MAX) 
    CAUTION: To avoid distortion, do not 
    connect port 02 to 8-ohm outputs. 
    PTRONIC 
    .03)  CIRCUIT 4 TO ELEC 
    TELEPHONE (PORT 
    CIRCUIT 5 TO ELEC 
    TELEPHONE OR :TRONIC 
    36 NOTES: 
    I. PEKU must be installed in slot 01. 
    2. Program 10-2, button/LED 09 “‘on’: fo. 
    BGM connection to port 02. 
    3. Cut W5 jumper on PEKU in slot 01. 
    4. Provide BGM to electronic telephone 
    and external page (PIOU/PIOUS/PEF 
    5. Volume is adjusted at BGM source 
    on/y (not at PEKU). r 
    spe, 
    ‘U). akers 
    A 
    -- II ! DR 1 OR DSS (PORT 06) 
    ~-j$--#~~ 1 -0CATi (OT) 
    1 OCA Rl (OR) TO EL 
    1-1 /_- -- ‘- ’ - .ECTRONIC TELEPHONES THAT RECEIVE oc 
    CIRCUIT 2 TO ELECTRONIC TELEPHONES THAT RECEIVE OCA 
    CIRCUIT 3 TO ELECTRONIC TELEPHONES THAT RECEIVE OCA 
    CIRCUIT 4 TO ELECTRONIC TELEPHONES THAT RECEIVE OCA 
    CIRCUIT 5 TO ELECTRONIC TELEPHONES THAT RECEIVE OCA 
    CIRCUIT 6 TO ELECTRONIC TELEPHONES THAT RECEIVE OCA 
    CIRCUIT 7 TO ELECTRONIC TELEPHONES THAT RECEIVE OCA 
    CIRCUIT 8 TO ELECTRONIC TELEPHONES THAT RECEIVE OCA 
    NOT USED 
    L v-o -a 
    
    						
    							INSTALLATION-WIRING DIAGRAMS 
    SECTION 200-096-209 
    FEBRUARY1991 
    MDF BLOCK NO. DKSU SLOT NO. . 
    NOTES: 
    1. Indicate if BGM or electronic telephone is connected (see Program IO-2 and 19); BGM connects to VT 
    and VR, circuit 3 only (DT and DR not used). 
    2. Indicate if electronic telephone or HDCB (allowed HDCB port numbers: 04, 12, 20, 28). 
    3. Indicate if electronic telephone or DSS no. 1, 2, 3, or 4. 
    4. Copy for each PEKU installed. 
    5. OCA wiring not shown, see MDF-to-electronic telephone wiring. 
    FlGURE9-5-PEKUSTATION/MDFCROSSCONNECTRECORD 
    9-7  
    						