Toshiba Strata Dk24, Dk56, Dk96 Instruction Manual
Have a look at the manual Toshiba Strata Dk24, Dk56, Dk96 Instruction Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
PROGRAMMINGPROCEDURES-INSTRUCTIONS/SYSTEMRECORDS SECTlON200-096-302 FEBRUARY1991 PROGRAM69(RELEASE3) VERlFlEDACCOUNTCODES(050-099) 7 More Codes 1 . SELECT = Verified Account Code Number (VACN) 1 VERIFIED Al VACN l-r 12 CCOUNT CODE (1 - 15 DIGITS) I- Verified Account Code (1 - 15 digits) . 1 VERIFIED ACCOUNT CODE (1 - 15 DIGITS) VACN 1 12 13 1415 16 17 18 ~9~10~11~12(13~14~15 - 076 077 078 083 084 085 087 097 098 099 Notes from page 2- 100 apply. 2-101
PROGRAMMINGPROCEDURES-INSTRUCTIONS/SYSTEMRECORDS SECTION 200-096-302 FEBRUARY1991 PROGRAM69(RELEASE3) VERIFIED ACCOUNTtODES(lOO-149) 7 More Codes 7 lXl-~S~H1!lSOC SELECT = Verified Account Code Number (VACq COUNT CODE (1 - 15 DIGITS) 1 VERIFIEDAC VACN 1 2 3 4 5 1617 18 ~9~10~11~12~13~14~15 100 1 i i i i i i i i i I 107,,,,,,,,,,,,,,, 108 116 118 l~-~-*q-ppp--j-p-j L Verified Account Code (1 - 15 digits) - , 1 VAIN!* ACCOUNT CODE (1 - 15 DIGITS) 2-102
PROGRAMMINGPROCEDURES-INSTRUCTIONS/SYSTEMRECORDS SECTION 200-096-302 PROGRAM69(RELEASE3) FEBRUARY1991 VERlFlEDACCOUNTCODES(150-199) 7 More Codes - SELECT = Verified Account Code Number (VACN) - L- Verified Account Code 11 w 15 diaits) Notes from page 2- 100 apply. 2-103
PROGRAMMING PROCEDURES-INSTRUCTIONS/SYSTEMRECORDS SECTION 200-096-302 FEBRUARY1991 PROGRAM69(RELEASE3) VERlFlEDACCOUNTCODES(200-249) I- More Codes -I SELECT = Verified Account Code Number (VACNI 1 VACN VERIFIED ACCOUNT CODE (1 - 15 DIGITS) 1 Notes from page 2- 7 00 apply. L-- Verified Account Code (1 - 15 dioits) 2-104
PROGRAMMINGPROCEDURES-INSTRUCTIONS/SYSTEMRECORDS SECTION 200-096-302 FEBRUARY1991 PROGRAM69(RELEASE3) VERlFlEDACCOUNTCODES(250-299) SELECT = Verified Account Code Number (VACN) 1 -VERIFIED ACCOUNT CODE (1 - 15 DIGITS) 1 VACN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 255 256 257 258 259 260 261 - 262 - 266 267 268 L Verified Account Code (I - 75 digits) CODE (1 - 15 DIGITS) Notes from page 2- 100 apply. 2-105
PROGRAMMlNGPROCEDURES-INSTRUCTIONS/SYSTEMRECORDS SECTION 200-096-302 FEBRUARY1991 PROGRAM70(RELEASE3) VERlFlEDACCOUNTCODETOLLRESTRlCTlONASSlGNMENTS (VAC 000 - 099) SELECT = Verified Account y DATA = VAC &yjt Code Number (VACN) 000 - 299 Restriction Cod;? 0 or 7 Enter 0 for no digit restriction. Enter 1 for digit restriction. NOTES: 1 063 1 1 I VAC Restrict Code (0 - 6) Enter 0 for No Station To// Restriction. Enter 1 for Area Code Toll Restriction. Enter 2 for Area Code Toll Restriction and 0 or 1 as 1st or 2nd digit. Enter 3 for Class 1 Toll Restriction. Enter 4 for Class 2 Toll Restriction. Enter 5 for Class 3 Toll Restriction. Enter 6 for Class 4 Toll Restriction. 1. For more information, see the instructions preceding the record sheets. 2. Initialized data reads 00 for all VACNs. 3. This restriction overrides the normal station restriction assigned in Program 48 when ‘a VAC is entered at the station. The station resumes its Program 48 restriction after the call is disconnected. .* 4. Range programming is not available. 2-106
PROGRAMMINGPROCEDURES-INSTRUCTIONS/SYSTEMRECORDS SECTlON200-096-302 FEBRUARY1991 PROGRAM70(RELEASE3) VERlFlEDACCOUNTCODETOLLRESTRlCTlONASSlGNMENTS (VAClOO-199) SELECT = Verified Account ____-----------,-‘;-7 DATA = VA C Digit VAC Restriction Code (0 - 6) Code Number (VACN) Restriction Code 0 or 1 Enter 0 for No Station Toll Restriction. Enter 0 for no digit restriction. Enter I for Area Code Toll Restriction. Enter 1 for digit restriction. Enter 2 for Area Code Toll Restriction and 0 or I as 1st or 2nd digit. Enter 3 for Class 1 Toll Restriction. Enter 4 for Class 2 Toll Restriction. Enter 5 for Class 3 Toll Restriction. Enter 6 for Class 4 Toll Restriction. 106 1 I in7 I 108 1 109 I VAC Digit Restrict VACN Code 164 165 166 167 168 169 170 171 172 173 174 “AC Restrict Code 3 3 Notes from page 2- IO6 apply. 2-107
PROGRAMMINGPROCEDURES-INSTRUCTIONS/SYSTEMRECORDS SECTION 200-096-302 FEBRUARY1991 PROGRAM70(RELEASE3) VERlFlEDACCOUNTCODETOLLRESTRlCTlONASSlGNMENTS , (VAC200-299) / SELECT = Verified Account Code Number (VACN) Restriction Code 0 or 1 Enter 0 for no digit restriction. Enter I for digit restriction. VAC Restriction Code (0 - 6) Enter 0 for No Station Toll Restriction. Enter 1 for Area Code Toll Restriction. Enter 2 for Area Code Toll Restriction and 0 or 1 as 1st or 2nd digit. Enter 3 for Class 1 Toll Restriction. Enter 4 for Class 2 Toll Restriction. Enter 5 for Class 3 Toll Restriction. Enter 6 for Class 4 Toll Restriction. 228 1 Notes from page 2- 106 apply. 2-108
PROGRAMMING PROCEDURES-INSTRUCTIONS/SYSTEM RECORDS SECTION 200-096-302 FEBRUARY 1991 PROGRAM 77-1 PERIPHERAL OPTIONS (DOOR PHONES/IMDU/PIOU/PIOUS/PEPU) p-pJT;lT;llpJ-pJr;l-$-JYJ-pJ-r;1 7 SELECT = 1 LED Key Light the key.s/LEDs that are marked with an X in the table below. NOTES: 1. For more information, see the instructions preceding the record sheets. 2. Initialized data leaves all LEDs off. 3. HDCB = Door Phone Control Box. Up to four HDCBs may be installed in a system. They must be assigned a PEKU or PEW port number to operate. 4. If a modem unit (IMDU) is installed on a PIOU or PIOUS, it can be accessed by dialing station 19. 5. If NT1 is turned on at an electronic or digital telephone, then the door phone will ring over external page. 6. This option applies to the PIOU/PIOUS/PEPU Door Lock Control (DRLK 0) assigned to electronic or digital telephone keys using Code 71 in Program 39; it does not apply to HDCB door locks. 7. HDCB4 is available with PCTU (1, 2, or 3), but not with PCTUSI. 8. Assigns Tenants 1 and 2 CO lines to night ring over PIOU external paging zones 1 - 4 (see the Installation Section 200-096-208 for more information regarding night ringing over selected paging zones). 2-109
I PROGRAMMINGPROCEDURES-INSTRUCTIONS/SYSTEMRECORDS SECTION 200-096-302 FEBRUARY1991 PROGRAM77-2 DOORPHONEBUSYSIGNAL/DOORLOCKASlGNMENTS SELECT = 2 LED Key Light the LED keys marked with an X in the table below. LED x Kev LED ON LED OFF 20 - - 19 - - 18 - - 17 - 16 (R2) HDCB4 B-jack is Door Lock Control #44 15 Door phone 4C Busy Out 14 Door phone 4B Busy Out 13 Door phone 4A Busv Out - B is connected to Door Phone 4B No Busy Signal No Busy Signal No Busv Sianal 12 (R2) 11 10 HDCB3 B-jack is Door Lock Control #3 Door phone 3C Busy Out Door phone 3B Busy Out 09 Door phone 3A Busy Out 08 (R2) HDCB2 B-jack is Door Lock Control #2 07 Door phone 2C Busy Out 06 Door phone 2B Busy Out 05 Door phone 2A Busv Out B is connected to Door Phone 3B No Busy Signal No Busy Signal No Busy Signal B is connected to Door Phone 2B No Busy Signal No Busy Signal No Busv Sianal 04 (R2) 03 02 HDCBl B-jack is Door Lock Control #l Door phone 1 C Busy Out Door phone 1 B Busy Out B is connected to Door Phone 1 B No Busy Signal No Busy Signal 01 I I Door phone 1A Busy Out No Busy Signal NOTES: 1. For more information, see the instructions preceding the record sheets. 2. initialized data reads all LEDs OFF. 3. HDCB Door Lock Control is available with Release 2 and higher. 4. HDCB4 is not available with PCTUS. 5. HDCB cannot be connected to PDKU or PSTU ports. HDCB PEKU/PESU Port Assignments 2-110