12 Printing System Database Parameters This chapter desc ribes the procedures and steps nec essary to print the system database parameters and various portions of the system.
Introduction 12-3 Introduction Print Database Parameters Pro g ram mi ng S te ps Pre ss FLASH an d di al [8 5]. The following message displays: Des crip ti on The buttons on the key telephone are defined as shown in the following ta bl e wh en e nt er ing t he P r in t Dat aba se P ar ame te rs pr ogr ammi ng a re a: The Print Database Parameters command dumps the entire database as a permanent record which can serve as a hardcopy of the database. The system baud rate must match that of the printer or receiving device. R efe r to th e f o ll o win g fi gu r es fo r ex ampl es o f the da ta base p ri nto u t s. Al so re fe r t o t he fol low ing par agr aph s for i nst r ucti ons on pr in ti ng portions of the database. PR IN T D ATAB A SE EN TER B UT TON N UMB ER SY STEM PAR AMETERSCO LINE ATTR IBUTESSTATION ATTRIBUTESPO RT - STA/CO =1Q=2W=3E=4R EXCEPTION TABLESSYSTEM SPEED NU MBER SLC R TAB LESEN T I R E SYSTEM =5T=6Y=7U=8I ICLID-D ID TABLESDI REC TOR Y DI A L TA BL EHU NT GRO UPSACD * OR U CD GR OUPS =9O=10 P=11 A=12 S VOICE MAIL GROUPSVERIFIED ACCT CODES =13 D=14 F=15 G=16 H =17 J=18 K=19 L=20 ; =21 Z=22 X=23 C=24 V * Features available with opti onal software.
12-4 Data base Prin ting Datab ase Printin g Pr in t Sys t em Pa ra m et er s Pro g ram mi ng S te ps 1. Press the SYSTEM PARAMETERS flexible button ( FLASH 85, Bu tton #1). Th e f oll owing me ssa ge dis pla ys: 2. To print the System Parameters database, press the HOLD button. The f oll owing me ssa ge dis pl ays: Whe n t he syst em fi nis hes se ndi ng t he in form at ion to t he pr in te r, a confirma tion tone is he ard. Des crip ti on The currently stored customer database can be printed or uploaded into a file. This command dumps the entire database as a permanent record whi ch can s er ve as a har dcopy of t he dat aba se . T he syst e m ba ud r at e must ma tc h tha t of t he pr int e r or r ec e iv ing de vic e . W hen pr int i ng t he System Parameters the following data prints: †All System Timers †All System Wide Options (External Night Ringing, Hold Preference) †Attenda nt Station(s ) Prog ram ming †Other System Assignments (Page/Relay Assign, Exec/Sec, SMDR) †Wee kl y Ni ght Mode Sche dul e P RIN T SY S PAR AM P RE SS H OLD P RIN T SY S PAR AM
Da ta b a se P r i n t i n g 1 2- 5 Figure 12-1: Sy stem Pa ra me ters Printout ----- SYSTEM PARAMETERS ---- --------------------SYSTEM FEATURES ------------- SYS HOLD RECALL EXC HOLD RECALL ATND RECALL TIMER TRANSFER RECALL PRESET FWD TIMER CALL FWD NO ANS PAUSE TIMER CALL PARK TIMER CONFERENCE TIMER PAGING TIMEOUT CO RING DETECT SLT RCVR TIMER M/W TONE TIMER HOOK SWITCH TIME HOOK SWT BOUNCE SMDR CALL QUAL AUTO CALL BACK REMINDER RING RELEASE GUARD INTERDIGIT T/O RPT REDIAL ATTENDANT DISPLAY CALL COVERAGE RING MODEM ANSWER T/O INT DIGIT PULSE DTMF ON/OFF TIME -- SYSTEM FEATURES ATTENDANT OVERRIDE HOLD PREFERENCE EXTERNAL NIGHT RING EXECUTIVE WARNING PAGE WARNING TONE BACKGROUND MUSIC LEAST COST ROUTING FORCED ACCOUNT CODE GROUP LISTENING IDLE SPEAKER MODE CALL COST DISPLAY MUSIC ON HOLD CALL QUALIFIER TONE BARGE IN WARN TONE60 180 1 45 10 15 2 180 10 15 3 20 0 10 10 30 3 0 3 5 60 1 5 25 300 1 -------- DISABLED SYSTEM DISABLED ENABLED ENABLED ENABLED DISABLED DISABLED DISABLED DISABLED DISABLED ENABLED DISABLED ENABLEDCO RING TONES VERIFIED ACCT CODES CALL FWD DISPLAY EXTERNAL DAY RING OVERFLOW STA FWD DIRECT XFER STATION LOCK LCR CALL PROGRESS RECORDING WARN TONE MAINTENANCE RINGBACK ON XFER 911 FEATURE -------------SYSTEM INC CO RING INC ICM RING CALL FORWARD BTN MSG WAIT VM BTN MSG CBCK DSS/BLF DND DSS/BLF AUTO CBCK DSS/BLF UCD UNAVL DSS/BLF TRANSFER CO RING RECALL CO RING EXCLUSIVE HOLD QUEUED CO RING SYSTEM HOLD IN USE HOLD CAMP ON BTN CALL BACK BTN LINE QUEUE BTN DND BTN ICM HOLD BTN LEADING DIGIT 1 LEADING DIGIT 2 LEADING DIGIT 3 LEADING DIGIT 4 LEADING DIGIT 5 LEADING DIGIT 6 LEADING DIGIT 7 LEADING DIGIT OPTION CENTREX DIGITS VM ID DIGITSENABLED DISABLED ENABLED DISABLED DISABLED ENABLED DISABLED ENABLED ENABLED DISABLED DISABLED DISABLED LE D RE D RE D RE D RE D RE D RE D RE D RE D RE D RE D GREEN GREEN RE D GREEN RE D RE D RE D RE D RE D LEADING NONE NONE NONE NONE NONE NONE DISABLED 4 3FLASH RATES ------- 480 IPM FLUTTER 120 IPM FLUTTER STEADY ON STEADY ON 120 IPM FLUTTER 60 IPM DBL WINK OFF 120 IPM FLASH 60 IPM DBL WINK OFF 120 IPM FLASH 480 IPM FLUTTER 120 IPM FLASH 480 IPM FLUTTER 60 IPM DBL WINK OFF 60 IPM FLASH 120 IPM FLASH 120 IPM FLASH 480 IPM FLUTTER STEADY ON 15 IPM FLASH DIGIT
12-6 Data base Prin ting MUSIC CHANNEL[3..8] CABINET SLOT TYPE CO - ## #### ## ## ## ------- ---- ---- 0 0 LCOB ATTENDANT STATIONS 0 1 DTIB 100 ## ## ## ## ## ## 0 2 LCOB 0 3 DTIB DATE & TIME FORMAT 0 4 LCOB MM/DD/YY, 12 HOURS 0 5 DTIB 0 6 LCOB PBX DIALING CODES 0 7 DTIB ## ## ## ## ## EXECUTIVE/SECRETARY PAIRINGS 1 = ### ### 2 = ### ### 3 = ### ### 4 = ### ### POWER SUPPLY TYPES ---------------------------- ON BOARD RELAY ASSIGNMENTS 10 AMPS 10 AMPS 10 AMPS 10 AMPS NONE NONE ALARM DESC. ALARM PERIOD THRESHOLD ATTENDANT MINOR MAJOR I/O BAUD RATE CARRIER LOSS Y 5 15 30 Y ------------------ BLUE ALARM Y 5 15 30 Y Port 1 = 9600 YELLOW ALARM Y 5 15 30 Y Port 2 = 9600 RED ALARM Y 5 15 30 Y Port 3 = 9600 BIPOLAR VAR. Y 5 15 30 Y Port 4 = 9600 SLIP ALARM Y 5 15 30 Y DATA ERRORS Y 5 15 30 Y AUTO NIGHT MODE N COLINE GROUP QUEUING WEEKLY NIGHT MODE SCHEDULE -------------------- -------------------------- GROUP 0 ENABLED END START GROUP 1 ENABLED DAY TIME TIME GROUP 2 ENABLED M 0 0800 1700 GROUP 3 ENABLED T 1 0800 1700 GROUP 4 ENABLED W 2 0800 1700 GROUP 5 ENABLED T 3 0800 1700 GROUP 6 ENABLED F 4 0800 1700 GROUP 7 ENABLED S 5 #### #### S 6 #### #### DIAL PULSE - 60/40 10 PPS Figure 12-1: Sy stem Pa ra me ters Printout
Da ta b a se P r i n t i n g 1 2- 7 Print CO Line Attributes Pro g ram mi ng S te ps 1 . Pr es s t he CO LI NE ATT R IBU TES fl ex ibl e but ton (F L ASH 8 5, Bu tton #2). Th e f oll owing me ssa ge dis pla ys: 2. To print data for: †AL L CO Li ne s, p re ss the HO LD button. †A specified CO Line Range, enter 6 digits (3 digits for the first line and 3 digits for the last line in the range) †One CO Li ne, en te r tha t l i ne twi c e: [0 01 0 01 ] 3 . The n pr ess the HO LD but t on. Th e fol lowi ng me ss age d is pla ys and the CO L ine da ta pr int s: When the system finishes sending the requested information to the printer, a conf irmation to ne is hea rd. Des crip ti on The Print CO Line Attributes command dumps the entire database as a permanent record which can serve as a hardcopy of the database The system baud rate must match that of the printer or receiving device. Whe n pr in ti ng t he CO Li ne at tr i but es the f oll owing dat a pr int s: †All CO Line parameters within the specified range. †CO Lin e r i ngin g as si gnmen ts wi thi n t he spe c if ie d r ange . †Di al Pulse Ra ti o a nd S pee d s etti ngs PRINT CO LINES P RE SS H OLD PRINTI NG CO LINE S
12-8 Data base Prin ting Figure 12-2: CO Line Attributes Printout CO LINE ATTRIBUTES ------------------ CO 01 CO 02 ------ ----- DIAL PULSE/DTMF - DTMF DIAL PULSE/DTMF - DTMF PBX/CO - CO PBX/CO - CO UNIVERSAL NIGHT ANS - ENABLED UNIVERSAL NIGHT ANS - ENABLED DISA TRK TO TRK - ENABLED DISA TRK TO TRK - ENABLED PRIVACY - ENABLED PRIVACY - ENABLED LOOOP SUPERVISION - 4 LOOP SUPERVISION - 4 DISA TYPE - NONE DISA TYPE - NONE LINE GROUP - 1 LINE GROUP - 1 CLASS OF SERVICE - 1 CLASS OF SERVICE - 1 LINE IDENTIFICATION - LINE 01 LINE IDENTIFICATION - LINE 02 CO DIRECTION - INCOMING-OUTGOING CO DIRECTION - INCOMING-OUTGOING RING ASSIGNMENTS RING ASSIGNMENTS 100A 100A TRANSMIT VOLUME - 0DB TRANSMIT VOLUME - 0DB PRESET FORWARD DEST - NONE PRESET FORWARD DEST - NONE PRESET FWD VMID - NONE PRESET FWD VMID - NONE UNIVERSAL DAY ANSWER - DISABLED UNIVERSAL DAY ANSWER - DISABLED MOH CHANNEL - 1 MOH CHANNEL - 1 RING TONE - 0 RING TONE - 0 911 TRUNK - DISABLED 911 TRUNK - DISABLED FLASH TIMER - 10 FLASH TIMER - 10 RING DELAY TIMER - 0 RING DELAY TIMER - 0 WINK TIMER - 140 WINK TIMER - 140 RELEASE TIMER - 20 RELEASE TIMER - 20 RESEIZE TIMER - 200 RESEIZE TIMER - 200 GUARD TIMER - 50 GUARD TIMER - 50 SEIZE TIMER - 10 SEIZE TIMER - 10 PRESET FWD TIMER - 100 PRESET FWD TIMER - 100 ... and so on through CO lines 012
Da ta b a se P r i n t i n g 1 2- 9 Print Station Attributes Pro g ram mi ng S te ps 1 . Pr es s t h e STATI ON AT TR I B U TE S f le x ib le bu t to n (FLASH 85, Bu tton #3). Th e f oll owing me ssa ge dis pla ys: 2. To print data for: †Al l st at ions , p re ss the HO LD but ton. †A specified Station Range, enter six digits to specify the Station ra nge (thr ee di gi ts for t he fir st st at i on and th re e d igi ts for t he la st st at ion in the r ange ): [100-131] = Tri ad- S †One station, enter that station twice: [101101] 3 . The n pr ess the HO LD but t on. Th e fol lowi ng me ss age d is pla ys and the requested information prints: When the system finishes sending the requested information to the printer, a conf irmation to ne is hea rd. Des crip ti on The Print Station Attributes command dumps the entire database as a permanent record which can serve as a hardcopy of the database. The system baud rate must match that of the printer or receiving device. Whe n pr in ti ng t he St at io n at t ri but es th e f oll owin g dat a pr int s: >> > All Cu rr en t St at io n P ar a met ers PRINT STATIONS P RE SS H OLD PRINTI NG STAT IONS