2-14 Sy stem Timers Des crip ti on The SLT Hook Flash Debounce Timer determines the time needed to determine a v alid on-hook or off- hook cond ition for single line telephones. On -Hook or Off -Hook signals that a re sh orter in duration than this timer are ignored by the system. Refer to Fi gur e 2-1 . By de faul t, th e S LT H ook Fl ash Deb ounce T im er is se t t o 0 .3 0 s econd s and is va ri abl e fro m 0 -1 se c onds in 10 m s i nc re me nts . T his i s a 3 -di git e nt ry where 010 equals 0.1 seconds. Figure 2-1: Hook S witch Activity SMD R Call Qu alif icatio n Timer Pro g ram mi ng S te ps 1 . Pr es s t he SM D R CA LL QUA L T IM ER fl ex b utt on ( FLASH 01, Bu tton #16). T he f oll owin g me ssa ge dis pl ays: 2. Enter a valid number on the dial pad that corresponds to 00-60 seconds in 1-second increments. 3. Press HOLD to save the entry. A confirmation tone is heard and the display updates. SMDR CALL QUA L 0 0-6 0 30 IGNORED Valid HOOK-FLASHValid ON-HOOK TIME (in seconds) 0 .1 .2 .3 .4 .5 .8 .9 1.0 1.5 2.0.7 .6
Syst em Timers 2 -15 Des crip ti on The SMDR Call Qualification Timer determines the time needed to det e rmi ne a va li d S MD R c al l fo r r ep o rt in g pur po se s. B y de faul t, the S MD R Call Qualification Timer is set to 30 seconds and is variable from 00-60 seconds in 1-second increments. Automatic Call Back Timer Pro g ram mi ng S te ps 1 . Pr es s t he AU TO CA LL BA CK TI ME R fl ex but ton (FLASH 01, Bu tton #17). T he f oll owin g me ssa ge dis pl ays: 2. Enter a valid number on the dial pad that corresponds to 00-99 seconds in 1-second increments. 3. Press HOLD to save the entry. A confirmation tone is heard and the display updates. Des crip ti on The Automatic Call Back Timer in vokes a call back a nytime a user listens to busy tone for a p rogramm able p eriod of time. By d efa ult, the Au to ma ti c Ca ll B ac k Ti me r is se t fo r 03 s ec o nds (e nabl ed ), a nd i s var ia ble from 00-99 seconds. A value of 00 disables this timer. An Automatic Call Back d oes not occur when this timer is disab led. Reminder Ring Timer Pro g ram mi ng S te ps 1. Pres s the REMINDER RING flex button (FLASH 01, Button #18). T he following message displays: AUTO C ALL BACK 0 0-9 9 03 REMINDER RING 00-99 00
2-16 Sy stem Timers 2. Enter a valid number that corresponds to 00-99 seconds in 1 second increments. A value of 00 disables the timer, therefore the user only r ec e iv es one ri ng b urs t at th e b egi nni ng of th e c a ll . 3. Press HOLD to save the entry. A confirmation tone is heard and the display updates. Des crip ti on Whe n a CO l ine r ings at a bus y s tat i on, t he cal l ri ngs at t he st ati on usin g muted ringing. The CO Line Ringing Option feature enables a user to receive a reminder ring instead of muted ring. This timer provides a re mi nder r in g e ver y t i me the t im er ex pir es , a s l ong as the i nc omin g CO line re mains connected . If the u ser continues their present conversation and the CO party does not hang up, the Re min der Ring tim er ex pire s an d the use r re ceives another ring burst. When the key set user ends the existing call, ringing for the CO call reverts to normal ringing. By default, the Reminder Ring Timer is set to 00 second and is variable from 00-99 seconds in 1 second increments. Inter-Digit Time-Out Pro g ram mi ng S te ps 1 . Pr es s t he I NTE R -DI GI T T IM E OUT fl ex but ton (FLA SH 01, Bu tton #20). The following message displays: 2. Enter a valid number on the dial pad that corresponds to 01-99 seconds in 1 second increments. 3. Press HOLD to save the entry. A confirmation tone is heard and the display updates. Des crip ti on The Inter-Digit Time-Out feature provides inter-digit time-out pr ogra mmi ng on a s yst em- wid e b asi s and appl ie s to int er com a nd L CR c al ls. DI SA , DI D. TI E i nt er -di gi t ti me -o u t s r em ain u naf fec t ed by thi s ti mer . By default, the Inter-Digit Time-out is set for 5 seconds, and is variable fr om 1–9 9 se conds. INTERDIGIT T / O 0 1-9 9 05
Additional Sy stem Timers 2 -17 Additional System Timers Pro g ram mi ng S te ps If the system is in the programming mode, continue using the program codes. If starting to program here, enter the programming mode. Pr es s FLASH and di al [02 ]. The following message displays: Des crip ti on Thi s sect i on de scr ibe s the pr oced ure s a nd s te ps nece ss ary t o pr ogr am addi tiona l Syste m T ime rs i n the Ti mer s prog ra mmin g ar ea . SY ST EM TIMER S EN TE R B U TTON N UM BE R SYSTEM R EDIAL TIMERATD DISPLAY TIM ERCALL CVRG RING TIMERMO DE M ANSWER T/O =1Q=2W=3E=4R PUL SE DIAL I/O TIMERDTMF TIME OP E RA T I ON =5T=6Y=7U=8I =9O=10 P=11 A=12 S =13 D=14 F=15 G=16 H =17 J=18 K=19 L=20 ; =21 Z=22 X=23 C=24 V
2-18 Additio nal Sy stem Timers Repeat Red ial Timer Pro g ram mi ng S te ps 1. Pres s the RPT REDIAL TIMER flex b utton ( FLASH 02, Butto n #1 ). The following message displays 2. Enter a valid number that corresponds to 006-999 seconds. 3. Press HOLD to save the entry. A confirmation tone is heard and the display updates. Des crip ti on The Repe at Redi al Ti me r l et s a digi t al k ey s ta ti on pr es s a fl ex ibl e b utt on or di al a code a nd r ed ial a bus y or no- answe r numbe r at sp eci fic int er va ls . The user is signaled via a queue callback indication. The Redial flexible button flashes at the callback rate of 120 ipm for 15 seconds. †If st at ion doe s not a nswe r wit hi n 1 5 second s, t he cal lb ack i s cancelled. †If st at ion is busy wi th an i nte rn al/e xte r nal cal l w hen t he Red ial que ue callba ck occurs, the callb ack occurs a fter the user g oes on-hook . By default, the Repeat Redial Timer is set for 1 minute (60) and is variable from 006-999 seconds. Tabl e 2- 2: Addi ti o nal Sys tem Ti m ers Def aul ts Program CodeFl ex ButtonF eat ureDefa ult (after initialization) Addi t io nal Sy st em Ti me rs FLASH 0 2 1 2 3 4 5 6Rep ea t Red ia l Timer AT D Di s pl ay T i m e r Ca l l C ov era ge Rin g Timer Mod em A nswer Time-o ut Pul se D ial I nter -Di gi t Tim er DTMF Ti me Op era tio n060 seco nds 01 sec on ds 5 seco nds 25 sec on ds 3 00ms 100ms ON / 100ms OFF R PT R ED I A L 0 06- 99 9 06 0
Additional Sy stem Timers 2 -19 Attendant Display Timer Pro g ram mi ng S te ps 1. Press the ATTENDANT DISPLAY TIMER flex button (FLASH 02, Bu tton #2). The fo ll owing mes sag e d is pla ys: 2. Enter a valid number on the dial pad that corresponds to 00-99 seconds. 3. Press HOLD to save the entry. A confirmation tone is heard and the display updates. Des crip ti on The Attendant Display Timer modifies the way in which multiple calls ringing at the attendant station display. Currently, if two calls are ringing at an at te ndant s ta ti on, when th e s ta ti on goe s off h ook, t he fi rs t call i s answ er ed. The LC D upd at es to s how t he sec on d c al l t hat i s r i nging whi ch sometimes does not allow the station to view the current call’s LCD information. This timer keeps the current call’s information on the LCD for the set time period, then shows any other calls ringing in at the time. By default, the Attendant Display Timer is set for 1 second and is variable from 00-99 seconds. Call C overage Ring Timer Pro g ram mi ng S te ps 1. Pres s the CALL CVRG RIN G TIMER f lex button (FLA SH 02, Butto n #3) . The following message displays: 2. Enter a valid number on the dial pad that corresponds to 00-99 seconds. 3. Press HOLD to save the entry. A confirmation tone is heard and the display updates. ATTENDANT DISPLAY 00-99 01 CAL L COVE RA GE RING 0 0-9 9 05
2-20 Additio nal Sy stem Timers Des crip ti on A Call Coverage Ring Timer enables the user to place another station under a flex button. When that station rings with an internal or external cal l, the D SS but ton for t hat st at ion ri ngs or fl ashe s. By de faul t , t he Ca ll Cov er age Ri ng T ime r is se t for 5 se conds and is var ia bl e f rom 00 -9 9 se conds. A va lue of 00 r es ult s in the LE D fla shi ng but the ca ll cove ra ge station does not ring. Modem Answer Timer Pro g ram mi ng S te ps 1. Press the MODEM ANSWER TIMER flex button (FLASH 02, Bu tton #4). Th e f oll owing me ssa ge dis pla ys: 2. Enter a valid number that corresponds to 025-999 seconds. 3. Press HOLD to save the entry. A confirmation tone is heard and the display updates. Des crip ti on The Mode m Answe r Ti me r deter mi nes how l ong the O n Boa rd mode m pr ovid es a car ri e r t one to a di st ant mode m. I f a con nect ion is not m ade at the end of this timer, the On Board modem hangs up. By default, the Modem Answer Timer is set fo r 25 seconds and is variable from 025-999 seconds. Pulse Dial Inter-Digit Timer Pro g ram mi ng S te ps 1 . Pr es s t he P ULS E D IA L I / D TI ME R fl ex but ton (FLASH 02, Bu tton #5). The following message displays: 2 . Ent er a val id numbe r on t he dia l pad tha t cor r esp onds to 30 0- 6 00 ms. MOD EM A NS WE R T/ O 0 25- 99 9 25 I N T D I G I T PU LS E 3 00- 60 0 30 0
Syst em Feat ures 1 Programm ing 2 -21 3. Press HOLD to save the entry. A confirmation tone is heard and the display updates. Des crip ti on This governs the inter-digit time o f the Pulse Dial Digits, rotary dial mode. By de faul t , t he Pulse D ial Ri ng T ime r is se t for 30 0 ms and is var i abl e f rom 300-600 ms. DT MF On / Of f Ti me Op erat io n Pro g ram mi ng S te ps 1. Press the DTMF TIME OPERATION flex b utton ( FLASH 02, Bu tton #6). The following message displays: 2. Enter a valid number (1-9) for DTMF On and Off Times (100-900 ms). 3. Press HOLD to save the entry. A confirmation tone is heard. Des crip ti on The DTMF On/Off Time feature lets the installer select the DTMF On/Off Ti me on a sys te m-wi de ba si s. Thi s l et s the i nst al le r cust omi ze t he sys te m for cer t ain app li cat ions t hat r equi r e m ore t han t he st and ard DT MF T ime of 100ms on and 100ms off. By de faul t , t he DT MF T ime O per at i on i s s et for 1 0 0ms O n and 1 00 ms Off . Sy stem Features 1 Pro gramming Pro g ram mi ng S te ps If the system is in the programming mode, continue using the program codes. If starting to program here, enter the programming mode. Pr es s FLASH and di al [05 ]. The following message displays: DTMF ON/OF F TIME 1- 9 1 SY ST EM FEATU R ES 1 EN TE R B U TTON N UM BE R
2-22 Sys tem Feat ures 1 Prog ra mming Des crip ti on Thi s sect i on de scr ibe s the pr oced ure s a nd s te ps nece ss ary t o pr ogr am Sys te m F eat ur es i n t he Syst e m Fe at ur es pr ogra mmin g ar ea . T he but tons on a digital telephone are shown in the following illustration: ATTN OV ERRID EHO L D PREFEREN CEEXTERNAL NIGHT RIN GEXECU TIV E OV ERRI DE =1Q=2W=3E=4R PAGE W ARN TO NEBACKGROUND MUS I CLCR ENABLEACCOUNT CODES =5T=6Y=7U=8I GRO UP LISTENINGIDLE SP EAK ER MODECALL COST DI SPL A YMUS I C ON HOLD =9O=10 P=11 A=12 S CALL QUALIFIER TO NE OPTIO N =13 D=14 F=15 G=16 H =17 J=18 K=19 L=20 ; =21 Z=22 X=23 C=24 V Ta bl e 2-3 : S yst em Feat ure s 1 De faul t s Pro gra m Co de Fl ex But to n Feat ureDefault (After Initialization) FLASH 05 1 2 3 4 5 6 7 8 9 10 11 12 13Atten dan t Overri de Ho ld Preference Ex ter nal Ni gh t R ing Executi ve War ning Pag e Warn in g Ton e Ba ck g rou nd Mu sic Le a s t C os t Ro ut ing Acco un t C o de Gro up L isten in g Id le Sp eak er Mod e Call Cost Display Feat ure Music On Ho ld Ca ll Qua li fier Ton e Opt io nDisabled System Disabled Enabled Enabled Enabled Disabled Disabled Disabled Disabled Disabled Enabled Disabled
Syst em Feat ures 1 Programm ing 2 -23 Attendant Override Pro g ram mi ng S te ps 1. Press the ATTN OVERRIDE flex button (FLASH 05, Button #1). 2. Enter a 0 or 1that corresponds with the following entries: [0] = Disab le d [1] = Ena ble d 3. Press HOLD to save the entry. A confirmation tone is heard. Des crip ti on When the Attendant Override feature is enabled, it lets the attendant ove rr id e a bus y st at i on or a st at ion in DND. By defa ult , At t enda nt Ov er ri de is di sa ble d. Ho ld Pre ference Pro g ram mi ng S te ps 1. Press the HOLD PREF flex button ( FLASH 05, Butto n #2). 2 . Ent er a val id numbe r (0 or 1 ) t hat cor re sponds wi th t he f oll owin g entries: [0] = Excl usi ve Hold [1] = Sys te m Hol d 3. Press HOLD to save the entry. A confirmation tone is heard. ATTENDANT OVERRIDE 1-0 DISA BLE D At ten dant Ov erri de fun ctio ns ONL Y whe n the At ten dant stati on is as si gne d a fle x butt on de si gna ted as A tten dan t Ov err ide . HOLD PREFERENCE 0-1 SY ST EM