    Have a look at the manual Siemens Saturn Epabx Oc1e Dyad Digital Telephone User Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 428 Siemens manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							SATURN EPABX A30808-X5051-E120-l-B919 
    CMU Procedures Issue 1, December 1984 
    CUSTOMER MEMORY UPDATE PROCEDURE: ATTASSN 
    TITLE: Attendant Assignments 
    Access Level: 3, 4 Page 1 of 2 
    I STEP NO. PROMPT/EXPLANATION 
    I. 
    1. ) DIS ATTASSN 
    2. ATTENDANT CONSOLE NUMBER (I-12) = nn , . . nn 
    Requests attendant console number(s) for which data is to be dis- nn = console number (1-12). 
    played. If more than one, separate each by spaces. Enter (CR) 
    to display all attendant assignments. 
    3. 1 DISPLAY ASSIGNABLE KEYS? (Y/N) = a 
    I 
    Requests whether key assignment data is to be shown for selected a = Y = Yes, a = N = No. 
    console(s). 
    NOTE: Entering (CR) is the same as entering N for No. 
    1. > ADD ATTASSN 
    2. PORT EQUIPMENT NUMBER (WXYZ) = nnnn 
    I 
    Requests PEN for new console assignment. nnnn = valid PEN. 
    3. ATTENDANT EXT # = nnnn 
    I 
    Requests station number to be assigned to added console. 
    NOTE: Assignment of an attendant station number is required. nnnn = extension number (O-9999). 
    4. EXCLUSIONS (CAS,INC,OPR,RCL) = aaa . . . aaa 
    Requests call type exclusions to be permanently assigned to the aaa = exclusion type (0 to 3 types sepa- 
    console; the attendant is not alerted for calls of these types. Enter rated by spaces); see Table 303.1. 
    (CR) for no exclusions. 
    1. 
    > DEL ATTASSN 
    I 
    2. ATTENDANT CONSOLE NUMBER (1-12) = nn 
    I 
    Requests attendant console number which is to be deleted. nn = console number (1-12). 
    NOTE: The attendant console must be placed out of service before the console can be deleted. 
    1. 
    > CHA ATTASSN 
    NOTE: The console must be placed out of service before the console can be changed. 
    2. ATTENDANT CONSOLE NUMBER (l-12) = nn 
    I 
    Requests attendant console number for which data is to be changed. nn = console number (1-12). 
    3. ATTENDANT EXT # = nnnn 
    Requests station number to be assigned to console. Enter (CR) nnnn = new extension number (O-9999). 
    for no change. 
    4. EXCLUSIONS (CAS,INC,OPR,RCL) = aaa . . . aaa 
    Requests type of call exclusions to be changed at this console. If 
    aaa = exclusion type (0 to 3 types); 
    more than one, separate each by spaces. Enter (CR) for no change. see Table 303.1.  
    						
    							SATURN EPABX A30808-X5051-E120-l-B919 
    CMU Procedures issue 1, December 1984 
    CUSTOMER MEMORY UPDATE PROCEDURE: ATTASSN 
    TITLE: Attendant Assignments 
    STEP NO. PROMPT/EXPLANATION Page 2 of 2 
    5. CALL EXCLUSION STATE (ON / OFF) = aaa . . . aaa 
    Requests new state for each exclusion type specified above. If more 
    aaa = exclusion state: ON or OFF. 
    than one, separate each by spaces. (Enter in same sequence.) 
    Table 303.1 Call Exclusion Types 
    ALPHANUMERIC 
    INPUT 
    CAS 
    INC 
    OPR 
    RCL Centralized Attendant Calls 
    Incoming Calls 
    Dialing 0 (Operator) Calls 
    Recalls DESCRIPTION 
    MNEMONICS USED IN THIS CMU PROCEDURE: 
    Mnemonic Definition 
    PEN Port Equipment Number  
    						
    							,’ - 
    SATURN EPABX 
    CMU Procedures A30808-X5051-E120-i-B919 - 
    Issue 1, December 1984 
    CUSTOMER MEMORY UPDATE PROCEDURE: ATTMAP 
    TITLE: Attendant Console Map Assignments 
    Access Level: 3, 4 ATTMAP 
    Page 1 of 3 
    STEP NO. PROMPT/EXPLANATION 
    1. )DIS ATTMAP 
    2. ATTENDANT CONSOLE NUMBER (1-12) = nn . . . nn 
    Requests attendant console number(s) for which data is to be dis- 
    played. If more than one, separate each by spaces. Enter (CR) 
    to display key assignment data for all consoles. nn = console number(s) (1-12). 
    1. )CHA ATTMAP 
    NOTE: The attendant console must be placed out of service before map assignments can be changed. 
    2. ATTENDANT CONSOLE NUMBER (1-12) = nn 
    Requests attendant console number for which assignments are to 
    nn = console number (l-12). 
    be changed. 
    3. ATTENDANT KEY NUMBER(S) (l-34) = nn . . . nn 
    Requests key number(s) to have assignment(s) changed. If more nn = key number(s); see Figure 304.1. 
    than one, separate each by spaces. 
    4. OLD KEY FEATURE ASSIGNMENT(S) = aaaaaaaa . . . aaaaaaaa 
    Requests old feature assigned to key(s) specified above. If more aaaaaaaa = feature; see Table 304.1. 
    than one, separate each by spaces. 
    5. NEW KEY FEATURE ASSIGNMENT(S) = aaaaaaaa . . . aaaaaaaa 
    Requests new feature to be assigned to key(s) specified. If more aaaaaaaa = feature; see Table 304.1. 
    than one, separate each by spaces. 
    6. ACCESS CODE FOR FEATURE = nnnn . . . nnnn 
    Requests access code(s) to be assigned to feature(s) assigned to nnnn = access code(s). 
    key(s). If more than one, separate each by spaces. Enter (CR) if 
    none. 
    NOTE: An access code must have been previously assigned before it can be inputted. 
    7. TRUNK GROUP NUMBER (O-31) = nn . . . nn 
    Requests trunk group number(s) to be assigned for ACOFTG fea-. nn = trunk group number (O-31). 
    ture. If more than one, separate each by spaces. Enter (CR) if none.  
    						
    							SATURN EPABX 
    A30808-X5051-El20-l-B919 
    CMU Procedures 
    Issue 1, December 1984 
    CUSTOMER MEMORY UPDATE PROCEDURE: ATTMAP 
    TITLE: Attendant Console Map Assignments 
    Page 2 of 3 
    Console Assignable Keys Console Preassigned Keys 
    3 1 
    4 2 
    6 5 
    7 10 (see Note 2) 
    i 21 16 
    11 22 
    12 23 
    13 24 
    14 26 
    15 (see Note 1) 27 
    17 28 
    18 29 
    19 31 
    20 32 
    25 33 
    30 34 
    NOTES: 1. The “FLASH” key must be assigned to key number 15 at a CAS Main. 
    2. The “CAS” key is automatically assigned in a CAS System. This key is not used in nor-&AS Systems. 
    Figure 304.1 Console Key Assignments  
    						
    							SATURN EPABX A30808-X5051-E120-l-B919 
    CMU Procedures Issue 1, December 1984 
    /’ CUSTOMER MEMORY UPDATE PROCEDURE: ATTMAP 
    TITLE: Attendant Console Map Assignments 
    Page 3 of 3 
    Table 304.1 Attendant Console Key Features 
    ALPHAMERIC 
    INPUT SEE 
    DESCRIPTION NOTE 
    NASN Not Assigned 
    SMDR Attendant-Activated SMDR 
    CONF Attendant Conference 
    ACOFACC ACOF: Feature Access Codes (See Table 304.2) 
    ACOFTG ACOF: Trunk Group Access 
    ACCT Attendant-Entered SMDR Account Code 
    OVERFLOW Attendant Overflow Facility 
    OVERRIDE Attendant Override 
    FLASH Attendant Trunk Flash Capability 
    TRKGRP Attendant Trunk Group Access 
    PAGE Attendant Voice Paging 
    EXCCAS Call Exclusion: CAS Calls 
    EXCINC Call Exclusion: Incoming Trunk Calls 
    EXCOPR Call Exclusion: Operator (Dial 0) Calls 
    EXCRCL Call Exclusion: Recalls 
    PARK Call Park 
    MSGSET Message Waiting Activation 
    MSGCAN Message Waiting Cancellation 
    MINALM Minor Alarm Identification 
    VOLUME Volume Control - Attendant 
    NOTES: 1. Not applicable to domestic (U.S.) systems. 
    2. Access code (ACC) required if this feature assigned. 
    3. Trunk group number required if this feature assigned. 
    4. Each ACOFACC Key controls only one feature access code. Refer to Table 304.2. 1 
    2,4 
    3 
    2 
    2 
    2 
    2 
    Table 304.2 Feature Access Codes Which Can Be Controlled Via the ACOFACC Key 
    Code Call Access 
    Dictation Access and Control 
    Meet-Me Conference Paging 
    Station-Controlled Conference 
    MNEMONICS USED IN THIS CMU PROCEDURE: 
    Mnemonic Definition 
    ACOF Attendant Control of Facilities 
    CAS Centralized Attendant Service 
    SMDR Station Message Detail Recording  
    						
    							SATURN EPABX A30808-X5051-E120-l-B919 - 
    CMU Procedures Issue 1, December 1984 
    CUSTOMER MEMORY UPDATE PROCEDURE: AUDIT 
    TITLE: Audit Control 
    Access Level: 3, 4 Page 1 of 2 
    STEP NO. PROMPT/EXPLANATION 
    1. ) DIS AUDIT 
    2. TYPE (TSTLIST, DMND) = aaaa 
    Requests type of audit data to be displayed. If TSTLIST, go to step aaaa = type of data; TSTLIST OR DMND. 
    3; otherwise, procedure is completed. 
    NOTE: Enter TSTLIST to display the status (enabled, disabled or standby) of the automatic test list shown in 
    Table 524.1; enter DMND to list the identity of any automatic test currently waiting to run as the result 
    of a user demand (see BEG AUDIT). 
    3. 1 DISPLAY TEST TYPE = aaaaaaa 
    Requests test type to be displayed. Enter (CR) to display the con- 
    tents of all the automatic tests shown in Table 524.1. aaaaaaa = test type; see Table 524.1. 
    NOTE: Audits which are enabled in the automatic test list are periodically run by the system, without manual 
    intervention. 
    1. ) BEG AUDIT 
    2. TEST TYPE = aaaaaaa 
    Requests type of audit test to be initiated. aaaaaaa = test type; see Table 524.1. 
    3. NUMBER OF TEST RUNS (l-9) = n 
    Requests number of test runs. n = test quantity (l-9). 
    NOTES: 1. A demand audit is a test initiated by a “BEG AUDIT” command. A demand audit is started immed- 
    iately, unless execution is blocked because another test is already running. Only one demand audit 
    can be waiting to run at any given time. An attempt to queue up a second demand audit will be rejected. 
    2. The execution of an audit test (demand or automatic) may result in the processor idle-time indicator 
    lights to stop, indicating that all processor idle time is being consumed by the test. 
    3. A display of alarm data will contain specific information regarding test failures from audit tests (de- 
    mand or automatic). 
    1. > CHA AUDIT 
    I I I 2. 
    CHANGE TEST TYPE = aaaaaaa 
    Requests type of audit test change to be made. aaaaaaa = test type; see Table 524.1. 
    3. 
    STATUS (ENABLED, DISABLED, STANDBY) = aaaaaaa 
    Requests status of audit test. aaaaaaa = test status: 
    ENABLED - will run periodically on active processor. 
    DISABLED - will not run periodically. 
    STANDBY - will run periodically on standby processor only.  
    						
    							SATURN EPABX 
    A30808-X5051-E120-l-8919 
    CMU Procedures 
    Issue 1, December 1984 
    CUSTOMER MEMORY UPDATE PROCEDURE: AUDIT 
    TITLE: Audit Control 
    Table 524.1 Audit Test Types 
    ALPHAMERIC 
    INPUT 
    DIGAPPR 
    DTMF 
    IOPLOOP 
    MEMCONT 
    MEMMIS 
    MEMPAR 
    MTSMEM 
    SPEECH DESCRIPTION 
    Digital Data Apparatus (OC II Only) 
    Dual-Tone Multifrequency Receiver and Tone Generator 
    Input/Output Processor Loop-Around 
    Memory Contents 
    Memory Mismatch (Duplex Systems Only) 
    Memory Parity 
    Memory Time Switch Memory Control 
    Speech Highway Control CAN RUN 
    ON 
    STANDBY 
    NO 
    NO 
    YES 
    YES 
    NO 
    YES 
    NO 
    NO 
    MNEMONICS USED IN THIS CMU PROCEDURE: 
    Mnemonic Definition 
    DMND Demand Test Type 
    TSTLIST 
    Test Listing Page 2 of 2  
    						
    							SATURN EPABX 
    CMU Procedures A30808-X5051-E120-l-B919 - 
    Issue 1, December 1984 
    CUSTOMER MEMORY UPDATE PROCEDURE: AUTHCODE 
    TITLE: Authorization Code Assignments 
    Access Level: 4 1 AUTHCODE ] 
    Page 1 of 2 
    I STEP NO. PROMPT/EXPLANATION 
    I 
    1. > DIS AUTHCODE 
    I 
    2. AUTH CODE OR INDEX? (A/l) = a 
    Requests whether authorization code or index range is to be dis- a = A = authorization code 
    played. If A is entered go to Setp 3. If I is entered go to step 4. a = I = index range. 
    3. AUTHORIZATION CODE = nnnnnn 
    Requests authorization code to be displayed. Enter (CR) for none. nnnnnn = Authorization code (00-999999) 
    Procedure is completed. 
    4. 1 INDEX RANGE = nn . . . nn 
    I 
    Requests index range for which authorization codes are to be dis- nn = index numbers (O-9999) 
    played. Separate index numbers by spaces. Enter (CR) for all. 
    Procedure is completed. 
    1. 
    2. 
    3. 
    4. 
    5. > ADD AUTHCODE 
    NEW AUTHORIZATION CODE = nnnnnn 
    Requests new two- to six-digit authorization code. nnnnnn = code (00-999999). 
    NOTE: For proper operataion of this feature, all authorization codes must be of the same length. 
    DISPLAY CODE ON SMDR? (Y/N) = a 
    Requests whether to display authorization code on SMDR. 
    NOTE: Entering (CR) is the same as entering Y for Yes. a = Y = Yes; a = N = No. 
    CLASS OF SERVICE NUMBER (O-31) = nn 
    Requests COS to apply to added authorization code. 
    DATA CLASS OF SERVICE NUM,(O-31) = nn 
    Requests data COS to apply to added authorization code. 
    (Needed for OC II feature package only.) 
    NOTE: Enter (CR) to indicate no data class of service. nn = COS (O-31). 
    nn = data COS (O-31). 
    I I I 1 
    I 1. 
    > DEL AUTHCODE 
    I 
    I I 1 I 2. AUTHORIZATION CODE TO BE DELETED = nnnnnn 
    Requests authorization code to be deleted. nnnnnn = code (00-999999).  
    						
    							SATURN EPABX A30808-X5051-E120-l-B919 
    CMU Procedures Issue 1, December 1984 
    CUSTOMER MEMORY UPDATE PROCEDURE: AUTHCODE ‘ 
    TITLE: Authorization Code Assignments 
    Page 2 of 2 
    STEP NO. PROMPT/EXPLANATION 
    1. ) CHA AUTHCODE 
    2. AUTHORIZATION CODE TO BE CHANGED = nnnnnn 
    Requests authorization code to be changed. nnnnnn = code (00-999999). 
    3. NEW AUTHORIZATION CODE = nnnnnn 
    Requests new two- to six-digit authorization code. Enter (CR) for nnnnnn = code (00-999999). 
    no change. 
    4. DISPLAY CODE ON SMDR? (Y/N) = a 
    Request whether to display authorization code on SMDR. a = Y = Yes; a = N = No. 
    NOTE: Enter (CR) for no change. 
    5. CLASS OF SERVICE NUMBER (O-31) = nn 
    Requests COS to apply to new authorization code. nn = COS (O-31). 
    NOTE: Enter (CR) for no change. 
    6. DATA CLASS OF SERVICE NUM (O-31) = nn 
    Requests data COS to apply to new authorization code. (Needed nn = data COS (O-31). 
    for OC II feature package only.) 
    NOTE: Enter (CR) for no change. 
    MNEMONICS USED IN THIS CMU PROCEDURE: 
    Mnemonic 
    cos 
    DISA Definition 
    Class of Service 
    Direct Inward System Access  
    						
    							SATURN EPABX A30808-X5051-E120-l-B919 - 
    CMU Procedures Issue 1, December 1984 
    CUSTOMER MEMORY UPDATE PROCEDURE: COMMAND 
    TITLE: CMU Command Name (Change) 
    Access Level: 4 1 COMMAND 1 
    Page 1 of 1 
    I STEP NO. PROMPT/EXPLANATION 
    I 
    1. ) DIS COMMAND 
    NOTE: This action displays all CMU procedures that can be accessed at the access level of the current user. 
    Note, however, that the DIS (Display) operation is allowed by many CMU procedures, even if the user 
    is blocked from Adds, Deletes, or Changes. 
    MNEMONICS USED IN THIS CMU PROCEDURE: 
    Mnemonic Definition 
    CMU Customer Memory Update (. ;  
    						