    Have a look at the manual Siemens Saturn Epabx Oc1e Dyad Digital Telephone User Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 428 Siemens manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							A30808-X5051-CliO-l-6919 
    Issue 1, December 1984 
    Table 4.04 Call-Type information Displays 
    (Continued) 
    Display definition 
    netted to the manually recalling station (destination) party. Both source 
    and destination parties were previously placed by the attendant in a locked 
    loop mode (via a LOOP key in the console). 
    on off Answered and connected to an incoming trunk or station (source) party 
    that was previously placed by the attendant in a park (hold) condition 
    (via the call park access code or the PARK key in the console). 
    CMU procedures. 
    4-514-6  
    						
    							SATURN EPABX 
    Attendant Console General Description and Operating Instructions .-..d 
    40-Character Alphanumeric Display Unit 
    25RCL 
    CALL P/RK 
    n n n! /,I R i I ..A!,- 
    i -1 
    26RCL 
    CAMP-ON 
    nn/nn r 
    27RCL 
    DATA 
    PR/I V 
    nn/nn 
    I 
    32 RIG L 
    Q’D TRU/NK 
    nn/nn 
    ! 
    ! 
    NOTES: 
    a/n = Alphanumerical value 
    a = Alphabetical letter 
    n = Numerical digit 
    0 = Attendant-dialed numerical digit (i.e.; station, trunk and/or access code numbs 
    nn/nn = Trunk group number (00 to 31) and trunk number (00 to 99) 
    nn nnnn = Station class-of-service (00 to 31) and station number (0000 to 9999) 
    NOTE: Screened areas denote typical displays since such incoming trunk identifications are customer-defined v  
    						
    							SRC 
    I 
    I I I I LED 
    nnnn on 
    k!zkl- nnnn on 
    El- 
    on 
    I 
    l&l4 on 
    / nnnn on 
    Fl+H 
    Iid 
    on 
    DEST 
    LED 
    on 
    on 
    off 
    off 
    on 
    off 
    off 
    off 
    A30808-X5051-CllO-l-B919 
    Issue 1, December 1984 
    Table 4.04 Call-Type Information Displays 
    (Continued) 
    Display Definition 
    Answered and connected to an incoming trunk or station (source) party 
    that was previously placed by the indicated station (destination) party 
    in a park (hold) condition which subsequently timed-out and automati- 
    cally rerouted to console for service. 
    Answered and connected to an incoming trunk (source) party that was 
    previously and automatically placed by the attendant console in a camp- 
    on (waiting) mode to the indicated busy station (destination) party which 
    subsequently timed-out and automatically rerouted to console for service. 
    Answered and connected to an incoming DID or DIT trunk (source) party 
    that was automatically rerouted to console since it extended to a station 
    number which is class-marked as a data line. 
    Answered and connected to a station (source) party that is manually recall- 
    ing the attendant which previously activated the message waiting fea- 
    ture (via the message waiting access code or MSG SET key in the 
    console) for such indicated station number. 
    Answered and connected to an incoming trunk (source) party that was 
    previously extended to the indicated station (destination) party which did 
    not answer after a predetermined number of rings and automatically 
    rerouted to console for service. 
    Answered and connected to a station (source) party that is class-marked 
    with the supervised release feature. A station class-marked with such 
    a feature and remains off-hook without dialing or connected to a busy 
    number for more than a predetermined time, is automatically rerouted 
    to console on an intercept treatment basis. 
    Answered and connected to an incoming DID or DIT trunk (source) that 
    was automatically rerouted to console since it extended to a station num- 
    ber which is out-of-service. 
    Answered and connected to an outgoing trunk (source) that was previ- 
    ously busy when attendant attempted to access it to place an outgoing 
    ~ trunk call and consequently activated the outgoing call queuing feature 
    c to automatically callback the console when an outgoing trunk is idle. 
    MU procedures. 
    4-714-8  
    						
    							SATURN EPABX 
    Attendant Console General Description and Operating Instructions 
    # 40-Character Alphanumeric Display Unit 
    33-R C L 
    Q’D TRUNK 
    nnlnnO@@@@@@@@@@@O 
    I II 
    34RCL 
    RESTRCTD nn 
    n n n n 
    nnnnnnnnr 
    35RCL 
    SERIES nn/nn 
    I I 
    NOTES: 
    a/n = Alphanumerical value 
    a = Alphabetical letter 
    n = Numerical digit 
    @ = Attendant-dialed numerical digit (i.e.; station, trunk and/or access code number) 
    nn/nn = Trunk group number (00 to 31) and trunk number (00 to 99) 
    nn nnnn = Station class-of-service (00 to 31) and station number (0000 to 9999)  
    						
    							A30808-X5051-C110-1-EI919 
    issue 1, December 1984 
    Table 4.04 Call-Type Information Displays 
    (Continued) 
    SRC 
    LED DEST 
    LED 
    Ofl off 
    on off 
    on 
    on 
    on 
    on 
    on off Display Definition 
    Answered and connected to an outgoing trunk (source) that was previ- 
    ously busy when attendant attempted to access it to place an outgoing 
    trunk call via the least cost route and consequently activated the outgo- 
    ing call queuing feature to automatically callback the console and out- 
    pulse the indicated stored trunk number (previously dialed by the 
    attendant) when an outgoing trunk is idle. 
    Answered and connected to a station (source) party that was automatical- 
    ly rerouted to console since it extended to the indicated trunk number which 
    is restricted for usage by such station because of its marked class-of-service 
    Answered and connected to an automatic recalling incoming trunk (source) 
    party that was previously placed by the attendant in a locked loop mode 
    (via a LOOP key in the console) along with a station (destination) party 
    which has disconnected from the call. This display indicates to the atten- 
    dant that the incoming trunk (source) party originally requested a serial 
    call, whereby it allows the trunk party to make a series of calls through 
    the attendant without the need to hang-up and call back into the EPABX. 
    Answered and connected to an incoming trunk (source) party that was 
    previously placed by the indicated station (destination) party in a hold 
    mode which subsequently timed-out and automatically rerouted to con- 
    sole for service. 
    Answered and connected to an incoming trunk (source) party that was 
    previously extended to the indicated station (destination) party which at- 
    tempted to transfer the incoming trunk party to another destination party 
    but the transferring process failed and the trunk party was automatical- 
    ly rerouted to console for service. 
    Answered and connected to an incoming DID or DIT trunk (source) party 
    that extended to a vacant station or code intercept number and auto- 
    matically rerouted to a vacant/ number recording announcement (via 
    customer-provided equipment) which was not available, and consequently 
    rerouted to console for service’.  
    						
    							SATURN EPABX A30808-X5051-CllO-l-6919 
    Attendant Console General Description and Operating instructions Issue 1. December 1984 
    1 A ANSWERING INCOMING-TYPE 
    “INC” KEY: TRUNK CALLS VIA 
    I 
    I 
    1 
    IIN/Ci IX/XlX/X/XiXIXiXl / / 1 ( 1 / 1 1  n n I n n II ! //I I I I i I I i / ! ! I j / 1 
    I I 
    SOURCE DESTINATION 
    0 0 
    I-- Refer to Table 4.04 for description of incoming-type trunk call information displays. 
    i B ANSWERING OPERATOR-TYPE CALLS VIA “OPR” KEY: 
    TALK TO 
    SOURCE 
    PARTY ) 
    I 
    o~PIR/ X1X1X ~1x1~ XIX1 In ~lnl~i~l~inl I 1 j I / I / I I j / / j / / I ! I ~ ’ 
    DESTINATION 
    0 or 0 
    L Refer to Table 4.04 for description of operator-type call information displays. 
    4-11  
    						
    							SATURN EPABX 
    Attendant Console General Description and Operating Instructions 
    . 
    A30808-X5051-CllO-l-B919 
    Issue 1, December 1984 
    1 c 
    ANSWERING RECALL-TYPE CALLS VIA. “RCL” KEY: 
    I 
    I I 
    R; c; L/ IXiXiX~X~XjXjx~Xj j ni ~1”i’,i~~~i I j / j 1 / / i / / / ! j / j j j / j i 
    I I 
    SOURCE DESTINATION 
    0 0 or0 
    L Refer to Table 4.04 for description of recall-type call information displays. 
    1 ANSWERING EITHER INCOMING, OPERATOR OR 
    RECALL-TYPE CALLS VIA “ANS” KEY: 
    I SOURCE DESTINATION 
    0 0 or 0 
    - Refer to Table 4.04 for description of incoming, operator and recall-type call information displays. 
    4-12  
    						
    							SATURN EPABX 
    Attendant Console General Description and Operating Instructions A30808-X5051-CllO-l-8919 
    Issue 1, December 1984 
    2 NO CONNECTION REQUESTED: 
    (a) (b) w (4 (e) 
    t 
    o/pJRi-injnj / /Rici~i--jn/n/ j / IiN/Ci-inin/ j i / i I !N/OjVi liioi 1 j4;::4,5 
    SOURCE 
    @ DESTINATION 
    0 
    NOTE: This display is prompted whenever the console is in an idle state and provides the 
    following information: 
    (a) Number of operator-type calls waiting for service. 
    (b) Number of recall-type calls waiting for service. 
    (c) Number of incoming-type trunk calls waiting for service. 
    (d) Current date. 
    (e) Time of day. 
    4-13  
    						
    							SATURN EPABX 
    A30808-X5051-CllO-l-B919 
    Attendant Console General Description and Operating Instructions 
    Issue 1, December 1984 
    3A REQUESTS CONNECTION TO STATION (STATION IDLE): 
    OPTIONAL 
    STATION ANSWERS 
    ANNOUNCE CALL i 
    I I 
    XIX/xi 1x1 XI x x XI x x x I 
    xxxxxxx 
    1 IR/ I IN/G! IINIGI /nnl id@@ 
    SOURCE 
    0 
    DESTINATION 
    0 
    NOTE: (1) Depressing a flashing INC, OPR, RCL or ANS key performs the same function in 
    addition to connecting the next call for processing 
    3B REQUESTS CONNECTION TO STATION (STATION WAS 
    RINGING BUT CALL ANSWERED BY ANOTHER STATION): 
    OPTIONAL 
    STATION ANSWERS 1 
    ANNOUNCE CALL j 
    I I (2) 
    XI xi X/ 1 XI XI X/ X/ XI XI X/ X/ / X/ XI XI X/ x1 XI / ~1 A/ LI ~1 / PI I / C/ K/ -1 ui P/ ! n/ n/ j r-1 n/ n/ n 
    I 
    / 
    SOURCE 
    0 
    DESTINATION 
    0 
    NOTES: (1) Depressing a flashing INC, OPR, RCL or ANS key performs the same function in 
    addition to connecting the next call for processing. 
    (2) Dialed station number is displayed first, then the station number which picked 
    up (answered) the call. 
    4-14  
    						
    							SATURN EPABX 
    A30808-X5051-CllO-l-6919 
    Attendant Console General Description and Operating Instructions 
    Issue 1, December 1984 
    3c REQUESTS CONNECT-ION TO A UCD GROUP 
    DIAL UCD 
    I OPTIONAL 
    b PILOT 
    NUMBER ) piq I,,, ) 
    R’-NGBACK / STATION ANSWERS 
    TONE HEARD ) I ANNOUNCE CALL 
    j 
    X/ X/ XI 1 X/ ~1 XI Xi X/ Xi Xi Xi 1 Xi X/ Xi Xi X/ X/ X/ / U/ C/ D/ / R/ I / N/ Gl I / N/ Gi ! 1 / j @@ 
    SOURCE 
    DESTINATION 
    0 
    0 
    NOTE: (1) 
    Depressing a flashing INC. OPR, RCL or ANS key performs the same function in 
    addition to connecting the next call for processing. 
    3D REQUESTS CONNECTION TO STATION (STATION BUSY 
    BUT A “HUNT” GROUP MEMBER): 
    RINGBACK 
    =I ) TONE HEARD ) OPTIONAL : 
    STATION ANSWERS 
    ANNOUNCE CALL 
    (2) . 
    I 
    xi x/ x/ I : 
    / X, Xi Xl Xi Xi Xi Xi Xi ! XI Xi Xi X/ XI Xi ! Hi U! Ni T/ / R/ I ; N/ Gi I / N( Gi j n: n ; 1 n: nl nl n 
    DESTINATION 
    0 . 
    NOTES: (1) 
    Depressing a flashing INC, OPR, RCL or ANS key performs the same function in 
    addition to connecting the next call for processing. 
    (2) 
    Dialed statlon number IS dlsplayed first, then changes to the hunted-to station 
    number. 