    Have a look at the manual Siemens Saturn Epabx Oc1e Dyad Digital Telephone User Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 428 Siemens manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							SATURN EPABX 
    Attendant Console General Description and Operating Instructions 
    11 L CALLING A STATION (STATION CLASS-MARKED 
    DIAL DESIRED STATION NUMBER > ,---, , ToNIJ;;ARD -, DRELpSR;fsyS 
    WHEN CONSOLE IS IDLE A30808-X5051-CilO-l-B919 
    Issue 1, December 1984 
    AS A DATA LINE): 
    SOURCE DESTINATION 
    0 gJ 
    NOTE: Busy override cannot be performed on this condition. 
    11 M CALLING A STATION (STATION IN A “LINE LOCKOUT” MODE): 
    4-46  
    						
    							SATURN EPABX A30808-X5051-CilO-l-6919 
    Attendant Console General Description and Operating Instructions Issue 1, December 1984 
    11 N CALLING A STATION (STATION IS OUT-OF-SERVICE): 
    I 
    I IOIU~TI IOIF~ /s!vIc! I I I l@l0l@~@l I I I I I I / ) I I I / / I ! I I ! 1 ’ 
    SOURCE DESTINATION 
    0 @ 
    110 CALLING A STATION (VACANT STATION OR CODE INTERCEPT 
    NUMBER): 
    4-47  
    						
    							SATURN EPABX 
    Attendant Console General Description and Operating Instructions 
    12A OVERRIDING (STATION BUSY): 
    A30808-X5051-CllO-l-6919 
    Issue 1, December 1984 
    (REFERENCE ONLY) 
    BUSY 
    TONE HEARD OF PRIORITY CALL 
    I 
    INFORM OTHER OR 
    (4) (5) 
    PRIMARY PARTY 
    ) TO GO ON-HOOK ) WI) Ai?=-:::~Y ) p( 
    SOURCE 
    0 
    DESTINATION 
    0 
    L[ f r,“,” --(Denotes source connected party) 
    NOTES: (1) Optional key. 
    (2) Override tone applied to connection. 
    (3) Both destination parties can hear attendant. 
    (4) OVERRIDE key LED extinguishes when either of the destination parties goes 
    on-hook and allows attendant to extend call. 
    (5) Depressing a flashing INC, OPR, RCL or ANS key performs the same function 
    in addition to connecting the next call for processing. 
    (6) “BY-OV” is displayed after attendant has actually broken-in to the connection; 
    if “PRVCY” is displayed instead, the Attendant Break-In Security or Data Priva- 
    cy feature is active in either of the destination parties and connection cannot be 
    overridden. 
    A station involved in a conference cannot be overridden at any time. 
    4-48  
    						
    							SATURN EPABX 
    Attendant Console General Description and Operating Instructions A30808-X5051-CllO-l-6919 
    Issue 1, December 1984 
    12B OVERRIDING (STATION IN A “DO NOT DISTURB” MODE): 
    (REFERENCE ONLY) 
    (1) 
    DEPRESS RINGBACK 
    INFORM PARTY OF 
    TONE HEARD ) OVERRIDE KEY ) TONE HEARD ) PRIORITY MESSAGE i 
    I 
    I 
    1 
    RINGING1 1 n/n j l~l0~0~0l I / / 1 I j I I I / I i I i i I / ! 1 ( 
    SOURCE 
    0 
    DESTINATION 
    (ZJ 
    Note: (1) OVERRIDE key’s LED remains extinguished. 
    4-49  
    						
    							SATURN EPABX A30808-X5051-CllO-i-B919 
    Attendant Console General Description and Operating Instructions Issue 1, December 1984 
    13A CALLING A PUBLIC NETWORK NUMBER (OUTGOING 
    TRUNK IDLE): 
    (1) 
    (2) IF ‘SMDR’ ACCOUNT CODE IS REQUIRED 
    DIAL DIRECT TRUNK DEPRESSTRK 
    GROUP ACCESS CODE or GRP KEY WHEN (1) 
    WHEN CONSOLE IS IDLE CONSOLE IS IDLE ) I[ ) ;;;;L$Ey;; ) Dr$L;;;;P:;:;ELs 
    I ACCOUNTCODE 
    I 
    I I 
    (1) CO DIAL DIAL PUBLIC CO RINGBACK 
    ) TONE HEARD ) NETWORKNUMBER ) TONE HEARD ) TRUNK ANSWERS , 
    TALK TO PARTY 
    i /OIUiTi !X X X X1X1X XIX1 n n ilnini 
    1 
    / / I ! I II / I II 11 j 1’ 
    I / 
    I I 
    SOURCE DESTINATION 
    0 @ 
    I- (Customer-defined via CMU procedures) 
    NOTES: (1) Number is displayed when dialed. 
    (2) Optional key. 
    4-50  
    						
    							SATURN EPABX A30808-X5051-CllO-i-B919 
    Attendant Console General Description and Operating Instructions Issue 1, December 1984 
    13Bl CALLING A PUBLIC NETWORK NUMBER (OUTGOING 
    TRUNK GROUP BUSY - NO QUEUING DESIRED): 
    (1) 
    DIAL DIRECT TRUNK 
    (2) DEPRESS 
    TRK GRP KEY I -IF ‘SMDR’ ACCOUNT CODE IS REQUIRED 
    (1) 
    GROUP ACCESS CODE or WHEN CONSOLE 
    WHEN CONSOLE IS IDLE IS IDLE 
    ! 
    ACCOUNT CODE 
    I 
    I 
    BUSY 
    TONE HEARD 
    L (Customer-defined via CMU procedures) DESTINATION 
    0 
    NOTES: (1) Number is displayed when dialed. 
    (2) Optional key. 
    4-51  
    						
    							SATURN EPABX A30808-X5051-CllO-l-B919 
    Attendant Console General Description and Operating instructions Issue 1, December 1984 
    13B2 CALLING A PUBLIC NETWORK NUMBER (OUTGOING 
    TRUNK GROUP BUSY - CALLBACK QUEUING DESIRED): 
    (4 
    (1) DEPRESS 
    DIAL DIRECT TRUNK TRK GRP KEY 
    GROUP ACCESS CODE or WHEN CONSOLE 
    WHEN CONSOLE IS IDLE IS IDLE IF ‘SMDR’ ACCOUNT CODE 1s REQUIRED 
    (1) 
    ACCOUNT CODE 
    .~~ 
    I 1 
    1 \O)uiTi 1 /x/~~X~+~x/xIx! 
    lQlU/E/U/Eid 
    / / 1 1 / / 1 
    1 ! 1 1 1 1 / / i ! 
    ! 1 1 
    1 I 
    SOURCE DESTINATION 0 0 
    - (Customer-defined via CMU procedures) 
    NOTES: (1) Number is displayed when dialed. 
    (2) Optional key. 
    (3) If busy tone continues and ‘Q-FULL” is displayed instead, retry later since all 
    facilities are presently busy. 
    When trunk is free, queuing feature recalls attendant. 
    4-52  
    						
    							SATURN EPABX A30808-X5051-CliO-l-B919 
    Attendant Console General Description and Operating Instructions Issue 1, December 1984 
    13B3 ‘CALLING A PUBLIC NETWORK NUMBER (OUTGOING 
    TRUNK GROUP BUSY - STANDBY QUEUING DESIRED): 
    (2) (1) DEPRESS 
    DIAL DIRECT TRUNK TRK GRP KEY 
    GROUP ACCESS CODE or WHEN CONSOLE 
    WHEN CONSOLE IS IDLE IS IDLE -IF ‘SMDR’ ACCOUNT CODE IS REQUIRED i 
    (1) I 
    ACCOUNT CODE 
    I 
    j 
    (3) SILENCE OR REMAIN OFF-HOOK 
    BUSY LOW TONE 
    ) TONE HEARD) HEARD b MUSIC IS 
    b UNTIL DIAL TONE 
    HEARD IS HEARD 
    I 
    1 
    SOURCE 
    0 
    (Customer-defined via CMU procedures) DESTINATION 
    0 
    NOTES: (1) Number displayed when dialed. 
    (2) Optional key. 
    (3) If busy tone continues and “Q-FULL” is displayed instead, retry later since all 
    facilities are presently busy. 
    . 
    4-53  
    						
    							SATURN EPABX A30808-X5051-CllO-l-6919 
    Attendant Console General Description and Operating Instructions Issue 1, December 1984 
    13c CALLING A PUBLIC NETWORK NUMBER WITH 
    ‘LCR’ 
    (OUTGOING TRUNK WITH ‘LCR’ IDLE): 
    (‘1 
    DIAL LEAST COST IF ‘SMDR’ ACCOUNT CODE IS REQUIRED 
    ROUTING (LCR) ACCESS 
    (1) 
    CoDE w,;:;~Nso” ) rsRC[ ) NEz&Ry;;;BER ) ;;;;LiL&;; ) D&LPEPEkD;~S 
    ACCOUNT CODE 
    (2) 
    b CONFIRMATION TONE 
    b CO RINGBACK TRUNK ANSWERS 
    IS HEARD TONE HEARD ) TALK TO PARTY ) Ey:Esv” ) m 
    I 
    SOURCE DESTINATION 
    0 0 
    NOTES: (1) Number displayed when dialed. 
    (2) Confirmation tone heard if SMDR special account code was dialed. 
    . 
    4-54  
    						
    							SATURN EPABX A30808-X5051-CllO-l-B919 
    Attendant Console General Description and Operating Instructions Issue 1, December 1984 
    13Dl CALLING A PUBLIC NETWORK NUMBER (OUTGOING 
    TRUNK GROUP WITH ‘LCR’ BUSY - NO QUEUING DESIRED): 
    (1) 
    DIAL LEAST COST 
    ROUTING (LCR) ACCESS 
    (1) 
    CODE W,;i;FNSOLE , 1~1 , DIAL PUBLIC 
    NETWORK NUMBER 
    (2) 
    b CONFIRMATION TONE 
    IS HEARD , IF ‘SMDR’ ACCOUNT CODE IS REQUIRED 
    (1) 
    b RECALL DIAL 
    b DIAL REQUIRED DIGITS 
    TONE HEARD OF ‘SMDR’ SPECIAL 
    ACCOUNT CODE 
    /: 
    SOURCE 
    0 
    DESTINATION 
    0 
    NOTES: (1) Number displayed when dialed. 
    (2) Confirmation tone heard if SMDR special account code was dialed. 