    Page 7
    NUMBERING PLAN
    19 Call Back (Cancel) Entry Number is “11”
    2000 – 2018 4-digit Administration Station Number
    3000 – 3011 4-digit Guest Station Number
    4
    Vacant Numbers 5
    6
    7
    80 Vacant Numbers
    81 Access to Area A Route Number: 2
    82 Access to Area B Route Number: 3
    83 Access to Area C Route Number: 4
    84 Access to Area D Route Number: 5
    85 Access to Area E Route Number: 6
    86
    Vacant Numbers
    87
    88 Access to Paging Equipment Route Number: 10
    89 Vacant Number
    9 Access to Central Office Route Number: 1
    Table 3  Example of Dial Access Numbering Plan for Guest Station
    Access Number Function Remarks
    0Same Number Access (Special Administration 
    Station Call)Special Administration 
    Station Number “2000”
    10
    Vacant Numbers 11
    12
    13
    14 Automatic Wake Up (Entry) Cancel Number is “15”
    15 Automatic Wake Up (Cancel) Entry Number is “14” Table 2  Example of Dial Access Numbering Plan for Administration Station (Continued)
    Access Number Function Remarks 
    						
    							NEAX2400 IMX Hotel Feature Programming Manual
    Page 8ND-70284 (E), Issue 2
    NUMBERING PLAN
    Commands Related to the Numbering Plan
    This section explains the commands related to the Numbering Plan and also explains command assignment
    procedure. 
    For details of command, refer to the NEAX2400 IMX Office Data Specification Manual.
    1. ASYD (Assignment of System Data)
    The system data pertaining to the Numbering Plan is as follows:
    SYS1 INDEX 160 b6
    This data is for determining whether the Numbering Plan Development Table is to be provided in common
    or separately for Administration and Guest stations. The commands to be used vary with the value
    assigned to the data as follows:
    a.) When the Table is to be provided in common for Administration and Guest stations. 
    (b
    6 = 1) 16
    Vacant Numbers 17
    18
    19
    2 Vacant Level
    3000 – 3011 4-digit Guest Station Number
    4
    Vacant Level 5
    6
    7 Floor ServiceIF: STN = 2001 Call,
    2F: STN = 2002 Call
    8 Vacant Level
    9 Access to Central Office Route Number: 1 Table 3  Example of Dial Access Numbering Plan for Guest Station (Continued)
    Access Number Function Remarks
    AANPAASP ASPS (Common)
    (Common)
    (Common)
    ASPF (Common)
    AAST (for Administration)
    AGST (for Guest) 
    						
    							NEAX2400 IMX Hotel Feature Programming Manual
    ND-70284 (E), Issue 2
    Page 9
    NUMBERING PLAN
    Commands Related to the Numbering Plan (cont’d)
    b.) When the Table is to be provided separately for Administration and Guest stations.
    (b
    6 = 0)
    Note:
    Administration stations can call Guest stations, but calls from Guest stations to Administration stations are restricted.
    A call from a Guest Station to a predetermined Administration Station is allowed via Same Number Access (Split
    Access) service.
    
    SYS1 INDEX 161 b6, b7
    b6: “#” code is used in Timing Start Service.
    (0/1 = Ineffective/Effective)
    b
    7: “*” code is used in Timing Start Service.
    (0/1 = Ineffective/Effective)
    When Timing Start is used, the system can have the following numbering:
    Examples:
    Floor
    Room No.Station No.
    1st 11 8111
    11th 11 81111
    In this case, if a 5-digit station number is dialed, the call is immediately connected to the called station.
    However, if a 4-digit station number is dialed, the call is connected to the called station with a certain
    delay. This is because the necessary number of digits of the access level assigned by the AANP/AGNP
    command is set to the number of digits of station number of larger number of digits. Thus, when a
    station number of smaller number of digits is dialed, the call is not connected to the called station until
    the Register Inter-Digit Timer in the system is timed out. In order that a call by dialing a station number
    of smaller number of digits can be immediately connected to the called station, assignment of these
    system data is necessary. If use of “#” code is made effective, a call to a station of smaller number of
    digits is connected immediately to the called station with “#” code dialed after the station number.
    2. AANP/AGNP (Assignment of Administration Numbering Plan/Assignment of Guest Numbering Plan)
    These commands are used to assign the minimum required number of digits to be used for determining the
    required service according to the first digit received.
    Note:
    When the Timing start service is used, the minimum required number of digits is assigned to the station number of
    larger number of digits.
    For example, when Station Number 200 and Station Number 2000 exist, Number of Necessary Digits (NND) = 4 is to
    be assigned with respect to the 1st Digit (1st DC) = 2.
    3. A dummy number (SID36, STATE 63) is necessary for the following case: When the system has stations
    “200” and “21000”, assign a dummy number for “210” with NND = 2.
    4. AASP/AGSP (Assignment of Administration Special Access Code/Assignment of Guest Special Access
    Code)
    These commands are used to specify the kind of service to be executed or the route to be accessed when
    a Special Access Code or Trunk Access Code is dialed. This data pertains to Administration stations.AANPAASP 
    ASPS (Common)
    (for Admin.)
    (for Admin.)
    ASPF (Common)
    AAST
    (for Admin.)
    AGNPAGSP 
    (for Guest)
    (for Guest)
    AGST
    (for Guest) 
    						
    							NEAX2400 IMX Hotel Feature Programming Manual
    Page 10ND-70284 (E), Issue 2
    NUMBERING PLAN
    Commands Related to the Numbering Plan (cont’d)
    5. ASPS (Assignment of Special Access Code for Same Number Access)
    When Split Access (Same Number Access) is required, these commands are used to specify the kind of
    service to be executed or the route to be accessed when a Special Access Code or Trunk Access Code is
    dialed.
    6. ASPF (Assignment of Special Access Code for Floor Service)
    This command is used to assign the calls from Guest stations on each floor, and can be terminated to a
    service station, such as laundry service and room service, on the same floor as the Guest Station.
    7. AAST/AGST (Assignment of Administration Station Data/Assignment of Guest Station Data)
    These commands are used to assign station data. When the system provides the floor service, these
    commands are used to assign floor service data with respect to Guest Room Service Station.
    Examples of Numbering Plan Data Assignments
    Examples of Numbering Plan data assignments are shown below. The procedures for data assignment are explained
    in the subsequent pages.
    Example:
    1. Dial Access Number
    For Administration
    Access Code
    Access To
    “0” Operator Call
    “100” ~ “1000” Guest Station on 1F
    “200” ~ “2000” Guest Station on 2F 
    “3000” ~ “3500” Administration Station Number
    “4000” Special Administration Station
    “5000” Room Service Station for 1F
    “5001” Room Service Station for 2F
    “9” C.O. Trunk
    For Guest
    Access Code
    Access To
    “0” Special Administration Station Call
    “100” ~ “1000” Guest Station on 1F
    “200” ~ “2000” Guest Station on 2F
    “8” Floor Service 
    “9” C.O. Trunk
    2. Others
    Numbering Plan Development Table is provided separately for Administration and Guest.
    Use of “#” code in the Timing Start Service is made effective. 
    						
    							NEAX2400 IMX Hotel Feature Programming Manual
    ND-70284 (E), Issue 2
    Page 11
    NUMBERING PLAN
    Examples of Numbering Plan Data Assignments (cont’d)
    Entry Procedure:
    START
    ASYD
    AANP
    SYS1INDEX 160, b6 = 0
    Numbering Plan Development Table is provided separately for 
    Administration and Guest.
    INDEX 161, b
    6 = 0
    Use of “#” code in the Timing Start Service is made effective.
    INDEX 165, b
    7 = 1
    Floor Service is provided.
    With respect to the 1st digit code (1ST DC), assign Number of 
    Necessary Digits (NND) as follows.
    1ST DC
    NND
    0 1
    1 4
    24
    3 4
    4 4
    5 4
    9 1
    With respect to the 1st digit code (1ST DC), assign Number of 
    Necessary Digits (NND) as follows.
    1ST DC
    NND
     0 1
     1 4
     2 4
     8 1
     9 1
    With respect to the Access Code (ACC) assign service 
    features as follows.
    ACCSRVSIDNo.KIND
    0SSC57 0 0
    ACC
    SRV RT
    9OGC1
    AGNP
    A
    AASP 
    						
    							NEAX2400 IMX Hotel Feature Programming Manual
    Page 12ND-70284 (E), Issue 2
    NUMBERING PLAN
    Examples of Numbering Plan Data Assignments (cont’d)
    AGSP
    ASPS
    With respect to the Access Code (ACC) assign service features 
    as follows:
    ACC
    SRVSIDNo.KIND
    0SSC57 0 0
    8SSC56 0 –
    ACC
    SRV RT
    9OGC1
    With respect to the data assigned by AASP and AGSP, assign 
    service features as follows:
    No.
    FSRVSIDSTN
     00SSC 2 –
    0 1 STN –  4000
    Assign the station data of Administration stations. Also, assign 
    the data for floor service as follows:
    STN
    ROOM CLASS
    “3000” ~ “3500” 0
    “4000” 0
    “5000” 1 – 7
    “5001” 1 – 7
    Assign the station data of Guest stations.
    (STN “100” – “1000”, STN “200” – “2000”)
    Assign the data related to the Room Service.
    Station on each floor as follows:
    No.
    ANXGFLRDC
     0 0 0 1 5000
     0 0 0 2 5001
    AAST
    AGST
    ASPF
    END
    A 
    						
    							NEAX2400 IMX Hotel Feature Programming Manual
    ND-70284 (E), Issue 2
    Page 13
    DESCRIPTION OF SERVICE FEATURES
    CHAPTER 3 DESCRIPTION OF SERVICE FEATURES
    Hotel Service Features
    This section explains each Hotel service feature by the following items:
     General Description
     Operating Procedure
     Service Conditions
     Assignment Procedure
    General Description
    This item explains a general description of the service feature.
    Operating Procedure
    This item explains the procedure to be followed for receiving a specific service feature concerned. When testing a
    service feature, perform installation test work steps by referring to this item.
    Service Conditions
    These items explain the functional outline of a specific service feature concerned and the matter of caution
    (hardware requirements, etc.) related to performance of that service feature. It is recommended that these items be
    referred to for more extensive knowledge of the service feature concerned.
    Assignment Procedure
    This item explains the procedure of assigning various kinds of data required for performance of a specific service
    feature concerned. When recording necessary data into Data Programming Sheets, make data entry by referring to
    this item. 
    						
    							NEAX2400 IMX Hotel Feature Programming Manual
    Page 14ND-70284 (E), Issue 2
    This page is for your notes. 
    						
    							NEAX2400 IMX Hotel Feature Programming Manual
    ND-70284 (E), Issue 2
    Page 15
    Automatic Wake-Up A-10
    A-10 Automatic Wake-Up
    General Description
    This service feature allows the system to be programmed to automatically call guest rooms at specified times. Upon
    answering, the guest is connected to a recorded announcement or music source. A printout of unanswered or blocked
    wake-up attempts for guest rooms is provided at the Hotel printer. This feature can be activated from the guest room
    stations, administration stations, Console, PMS Terminal, or predetermined Special Administration Station. 
    Operating Procedure
    To set AUTOMATIC WAKE-UP from a guest room:
    a.) With separate set and cancel codes (24-hour time only):
    b.) When set and cancel codes are the same:
    To cancel AUTOMATIC WAKE-UP from Guest Room:
    a.) With separate set and cancel codes (24-hour time only):
    b.) When set and cancel codes are the same:
    Step Action Result
    1
    Lift the handset. Receive dial tone.
    2Dial WAKE-UP code. Hear special dial tone.
    3Dial desired time of AUTOMATIC WAKE-UP. Hear service set tone.
    4Hang up.
    Step Action Result
    1
    Lift the handset. Receive dial tone.
    2Dial WAKE-UP code. Hear special dial tone.
    3Dial desired time of AUTOMATIC WAKE-UP. Hear service set tone.
    4Hang up.
    Step Action Result
    1
    Lift the handset. Receive dial tone.
    2Dial CANCEL AUTOMATIC WAKE-UP code. Hear service dial tone.
    3Hang up.
    Step Action Result
    1
    Lift the handset. Receive dial tone.
    2Dial WAKE-UP code. Hear special dial tone.
    3Dial the digit “3”. Hear service set tone.
    4Hang up. 
    						
    							NEAX2400 IMX Hotel Feature Programming Manual
    Page 16ND-70284 (E), Issue 2
    A-10 Automatic Wake-Up
    Operating Procedure (cont’d)
    To set AUTOMATIC WAKE-UP from a Regular Administration Station:
    Only separate set and cancel codes will operate from a regular administration station.
    To cancel AUTOMATIC WAKE-UP from a Regular Administration Station:
    Only separate set and cancel codes will operate from a regular administration station.
    To set AUTOMATIC WAKE-UP from a Special Administration Station:
    Only separate set and cancel codes will operate from a special Administration station.
    To cancel AUTOMATIC WAKE-UP from a Special Administration Station:
    To set AUTOMATIC WAKE-UP from the Front Desk Terminal or Console using the WUS/WUR (Wake-Up Set/
    Wake-Up Reset) key:
    a.) When guest calls to request a wake-up call (see DIRECT SERVICE SET/RESET [D-25]):
    Step Action Result
    1
    Lift the handset.  Receive dial tone.
    2Dial SET WAKE-UP code. Hear special dial tone.
    3Dial desired time of AUTOMATIC WAKE-UP. Hear service set tone.
    4Hang up.
    Step Action Result
    1
    Lift the handset.  Receive dial tone.
    2Dial CANCEL WAKE-UP code. Hear service set tone.
    3Hang up.
    Step Action Result
    1
    Lift the handset.  Receive dial tone.
    2Dial SET WAKE-UP code. Hear special dial tone.
    3Dial desired time of AUTOMATIC WAKE-UP, then 
    dial the guest room number.Hear service set tone.
    4Hang up.
    Step Action Result
    1
    Lift the handset.  Receive dial tone.
    2Dial CANCEL WAKE-UP code and guest room 
    number.Hear service set tone.
    3Hang up.
    Step Action Result
    1
    Press the WUS key while still connected with the 
    guest room.
    2Dial the wake-up time requested. (Use of 12-hour or 
    24-hour time is set in system data.). 
    						