Home > Lucent Technologies > Communications System > Lucent Technologies Definity Audix System Release 4.0 Screens Reference Manual

Lucent Technologies Definity Audix System Release 4.0 Screens Reference Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies Definity Audix System Release 4.0 Screens Reference Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-9 disable/enable Alarm-Origination 
    3
    disable/enable Alarm-Origination
    The Disab le/Enab le Alarm-Orig ination sc reens are used  to temporarily d isable 
    (or reenab le) the automatic  alarm rep orting  feature, take status of any alarms, 
    and  test alarms. It is typ ic ally used  b y Luc ent Tec hnolog ies p ersonnel to d isab le 
    alarm rep orting while troubleshooting  and  rep airing  the system. (Alarm 
    orig ination is automatic ally re-enab led  when the log in that d isab led  it log s off.)
    enable alarm-origination
     
    disable alarm-origination
     
    status alarm-origination
    test alarm-origination
    Pressing    (Enter) after initially entering  the sc reen will d isable (or reenab le) the 
    alarm orig ination feature. 
    NOTE:
    This c ommand  req uires craft or hig her-level log in permissions.
     
    Field Descriptions
    This is a d isp lay only sc reen. There are no d ata entry field s. 
    F3 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-10 disable/enable Alarm-Origination 
    3
    status Alarm-Origination
    The Status Alarm-Orig ination sc reen d isp lays the c urrent status of the alarm 
    orig ination feature. 
    status alarm-origination
     
    NOTE:
    This sc reen c an b e ac c essed while the DEFINITY AUDIX System is in the 
    OA&M state.
    Field Descriptions 
    Field Name Description Valid Entries (display only)
    alarm-orig ination Current alarm-orig ination state off (alarm orig ination is turned  off) 
    active (an alarm c all in p rog ress) 
    enab led  (alarm orig ination is enab led  
    b ut c urrently id le) 
    d isabled (alarm orig ination is 
    temporarily disabled)
    remote port status Current status of the remote 
    acc ess p ort.Incoming, Outgoing , Idle 
    d ata rate Currently ad ministered d ata 
    transmission rate. 1200, 2400, 4800, 9600 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-11 disable/enable Alarm-Origination 
    3
    test Alarm-Origination
    The Test Results Orig ination sc reen initiates a d emand  alarm orig ination test and  
    d isp lays the results of the test. 
    test alarm-origination
    nPress   (Enter) after initially entering  the sc reen to start the test. 
    nPress   (Canc el) after initially entering  the sc reen to return the user to the 
    c ommand  line without starting  the test. 
    nPress   (Enter) after starting  the test to p ut the test in the bac kg round  
    and  return the user to the c ommand  line. 
    nPress   (Canc el) after starting  the test to abort the test and  return the 
    user to the c ommand  line. 
    NOTE:
    This c ommand  req uires the craft or hig her-level login p ermissions.
    F3
    F1
    F3
    F1 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-12 disable/enable Alarm-Origination 
    3
    Field Descriptions 
    Field Name Description Valid Entries (display only)
    Date Date and  time test was req uested .
    Resourc e Typ e of resource b eing tested .
    Loc . Loc ation of the alarm orig ination 
    resourc e.7 c harac ter string  that 
    ind icates port network, carrier, 
    slot, and  p ort. For examp le, 
    01a0201 ind icates 
    p ort-network= 01, carrier= a, 
    slot= 02, p ort= 01. 
    Test Name Name of test b eing  exec uted .
    Most Rec ent Test 
    Res ul tCode ind ic ating  the results of the last 
    tests run.b lank (test not exec uted)
    R (test is running )
    P (last test p assed
    F (last test failed) 
    A (last test ab orted ) 
    Test Result String Ad ditional test result information.
    Test Counters
    Pass  No. of times the test has p assed  sinc e 
    the test c ommand was exec uted . 
    Fail  No. of times the test has failed sinc e the 
    test c ommand  was exec uted . 
    Abort  No. of times the test has ab orted  sinc e 
    the test c ommand was exec uted .  
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-13 disable/enable Alarm-Origination 
    3
    Additional Specifications
    While the test is running , you have three op tions: 
    1. Press   (Canc el) to ab ort the test and  return to the c ommand  line. 
    2. Wait for the test to c omp lete. 
    3. Press   (Enter) to p ut the test in the b ac kg round  and  return to the 
    c ommand  line. 
    Ty p e  status test
     to rec onnec t to the sc reen of a test running  in b ac kg round , or to 
    d isp lay the results of the most rec ently c omp leted  test. 
    A one-minute d elay is availab le to allow remote testing  (test will fail b usy if you 
    are logg ed  on remotely.) To use this test feature:
    1. Start test.
    2. Put in b ac kg round .
    3. Logoff.
    4. Log  b ac k in after one minute.
    5. Check log for pass/fail status.
    F1
    F3 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-14 display Alarms 
    3
    display Alarms
    Th e Alarm Rep ort sc reen d isp lays ac tive or resolved  DEFINITY AUDIX System 
    alarms. 
    display alarms
    The Alarm Rep ort sc reen has two p ag es as shown b elow. Use the first pag e to 
    sp ec ify whic h alarms will b e d isp layed  in the rep ort. 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-15 display Alarms 
    3
    The sec ond  p ag e d isp lays the req uested alarm information.
    Field Descriptions 
    Field Name Description Valid Entries
    NOTE:
    The first time this sc reen is used after a restart or reb oot, the field s on the 
    selec tion pag e of the sc reen are b lank. Sub seq uently, eac h field on the 
    selec tion pag e of the sc reen is p op ulated  with the value entered the last 
    time the sc reen was used .
    SELECTION PAGE
    ALARM TYPES
     Active? Disp lays ac tive alarms in the alarm report.  y (d isplay active alarms) 
    n (not d isp lay ac tive 
    alarms)
    NOTE:
    There must be a y in either the Ac tive field or the Resolved ? field  for 
    alarm entries to b e d isp layed  in the rep ort. You must req uest either 
    ac tive or resolved alarms, b ut not b oth alarms simultaneously. 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-16 display Alarms 
    3
    Resolved ?  Disp lays resolved  alarms in the alarm rep ort.  y (d isplay resolved  alarms)
    n (not d isp lay resolved  
    alarms)
    NOTE:
    You may req uest major alarm, minor alarm, warning , or any 
    comb ination of these for a report.
    Major? Disp lays major alarms in the alarm rep ort.  y (d isplay major alarms)
    n (not d isp lay major 
    alarms) 
    Minor? Disp lays minor alarms in the alarm rep ort.  y (d isplay minor alarms)
    n (not d isp lay minor 
    alarms)
    Warning ? Disp lays warning s in the alarm rep ort.  y (d isplay warnings) 
    n (not d isp lay warning s)
    Start Date Beg inning  d ate for the alarm report.
    yy <  70 is assumed  to b e the 21st c entury.blank (d isp lays all ac tive or 
    resolved  alarms) 
    date in mm/d d /yy format 
    Time Beg inning  hour and  minute of the g iven d ay 
    for the alarm report. The Start Date field  must 
    have valid  entries before this field  can b e 
    used.blank (d isp lays all alarms 
    for the spec ified  Start Date)
    time in hh:mm format
    Resourc e Typ e Spec ific typ e of alarmed  resource for the 
    alarm rep ort. If this field contains a resource 
    typ e, only alarms related  to the sp ec ified  
    resourc e type are d isplayed .any resource type defined 
    in 
    DEFINITY AUDIX System 
    Release 4.0 Maintenance
    , 
    585-300-121. 
    Loc ation Further sp ecifies the alarm rep ort b y 
    req uesting  a DEFINITY AUDIX System 
    loc ation for the fault resource typ e. If this 
    field c ontains a location, the Resource Typ e 
    field  must c ontain a value. Disp lays only 
    alarms related  to the sp ecified  resourc e typ e 
    and  loc ation. To view valid  locations for this 
    system, ac c ess list configuration or 
    display voice group screen.5 to 7 charac ter p ort 
    ad d ress of the sc reen 
    port-network (2 d igits), 
    carrier (1 letter), slot (2 
    dig its), and p ort (2 dig its). 
    For examp le, 01a0201 
    sp ec ifies a p ort location as 
    follows: p ort-network= 01, 
    carrier= a, slot= 02, and  
    port=01. 
    NOTE:
    A b oard  location consists of only five c haracters that sp ec ify the 
    port-network, the carrier, and  the slot. If the first five c haracters 
    sp ec ify a valid b oard  location, entering  d ig its in the 6th and  7th 
    positions (for a port) will generate an error message. A p ort loc ation 
    req uires all seven charac ters. Valid  ranges are:
    Port-network 0 - 99 
    Carrier   A - E 
    Slot   01 - 24 
    Port   01 - 24 Field Name Description Valid Entries 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-17 display Alarms 
    3
    Fault Code Fault c ode for the g iven resource type. If this 
    field c ontains a fault c od e, d isp lays only 
    alarms with this fault c od e.0 - 9999
    NOTE:
    Eac h resource typ e has its own set of fault c od es. Therefore, 
    sp ec ifying  a fault cod e without a resourc e type name c an d isplay 
    multiple resourc e typ es with the same fault c ode. 
    DISPLAY PAGE 
    Resourc e Typ e Spec ific typ e of alarmed  resource. Possible values in this field 
    are any resourc e typ e 
    defined  in 
    DEFINITY 
    AUDIX System Release 4.0 
    Maintenanc e
    , 
    585-300-121.
    Loc ation 5 to 7 c haracter location for the fault 
    resourc e type.
    Alm Lvl Alarm severity level. MAJ (major), MIN (minor), 
    WRN (warning) 
    Fault Code Fault c od e for a spec ific alarm for the given 
    resourc e type. Eac h resourc e type has its 
    own set of fault c od es.0 to 9999
    Ack Ind icates whether the alarm was p resent 
    d uring  the last alarm orig ination c all, i.e., the 
    alarm has b een reported  to the servic es 
    org anization. However, alarms may not have 
    b een sent if there were a sig nificant numb er 
    of hig her p riority alarms. y (alarm was p resent 
    during  the last referral c all) 
    n (alarm was not p resent 
    during  the last referral c all)
    Date/Time Alarmed Date and  time the alarm was raised  against 
    the g iven resourc e. This field  should  always 
    have a value. If the Date/Time Resolved 
    field s are b lank, the alarm 
    is c urrently ac tive. 
    Date/Time Resolved Date and  the time the alarm was resolved  If 
    these fields are blank, the alarm is c urrently 
    active. If only ac tive alarms are 
    displayed, these fields 
    should always be blank.
    If only resolved alarms are 
    disp layed, this field should  
    always have a value.
    Resolve Reason Cause of the alarm resolution. This field  is 
    b lank for active alarms.Maint (resolved by 
    maintenanc e, resourc e 
    rec overed .) 
    Reb oot (system reb ooted . 
    All ac tive alarms resolved .
    Remove (alarm resolved by 
    removing  the resource.  Field Name Description Valid Entries 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-18 add Announcement-Set 
    3
    add Announcement-Set
    The Announc ement Set sc reens are used to add , remove, c op y or list an 
    announc ement set. 
    add announcement set
     
    annc-set-name 
    remove announcement set
     
    annc-set-name 
    copy announcement set 
    annc-set-name
    list announcement set annc-set-name
    Th e  announcement-set-name is the name of the announc ement set to b e ac ted  
    up on.
    Field Descriptions 
    Field Name Description (display only)
    Announc ement Set Name of the announcement set b eing ad ded  or removed , as entered on 
    the c ommand  line. For add, the annc. set named by 
    annc-set-name must 
    not exist and  must be touc h-tone unique with other existing  annc. set 
    names. For remove, the annc . set named b y 
    annc-set-name must exist 
    and  must not b e the active annc. set.  
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies Definity Audix System Release 4.0 Screens Reference Manual