Home > Lucent Technologies > Communications System > Lucent Technologies Definity Audix System Release 4.0 Screens Reference Manual

Lucent Technologies Definity Audix System Release 4.0 Screens Reference Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies Definity Audix System Release 4.0 Screens Reference Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-219 display System-Parameters imapi-Options 
    3
    LA N  Su b n e t  M as k Set s  A U D I X I P Su b n e t  M as k.  
    This is obtained  from the LAN 
    administrator.nnn.nnn.nnn.nnn where nnn 
    is a number between 0 to 
    255. (You must enter  “ .” )
    Default LAN 
    Gateway IP Ad d ressSets Default LAN Gateway IP 
    Ad d ress. This is ob tained  from 
    the LAN ad ministrator.
    nnn.nnn.nnn.nnn where nnn 
    is a numb er from 1 to 126 or 
    from 128 to 254. (You must 
    enter  “.”)
    Link Integ rity Must b e ad ministered  to 
    ind icate if the LAN Network 
    Interfac e Card  has link integ rity 
    turned on or off.y (link integrity is on)
    n (link integ rity is off)y 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-220 display System-Parameters Limits 
    3
    display System-Parameters Limits
    The System-Parameters Limits sc reen is used  to ad minister limits on sp ac e 
    alloc ation for messag es, sub sc rib ers, and  ad ministration lists and  log s. 
    display system-parameters limits 
    change system-parameters limits  
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-221 display System-Parameters Limits 
    3
    Field Descriptions
    Name Description Valid Entries Default
    Messag e Leng ths, 
    MaximumLeng th, in second s, of the long est 
    messag e that c an b e c reated  b y any 
    sub sc rib er. Maximum messag e 
    lengths for individual subscribers 
    c an b e further restricted  on the c lass 
    of servic e and sub scrib er sc reens.16 to 1200 1200 
    Messag e Leng ths, 
    MinimumLeng th, in tenths of a second, of the 
    shortest messag e that the DEFINITY 
    AUDIX System rec ognizes as a 
    messag e0 to 99 10 tenths
    Messag es, Total in 
    All Mailb oxesMaximum numb er of messag es 
    exp ec ted  in all sub sc rib ers’ 
    mailb oxes at any one time0 to 999999 50000 
    Messag es, Awaiting  
    DeliveryMaximum numb er of messag es 
    exp ec ted  in the system d elivery 
    q ueue. The rec ommended  value is 
    10% of the value in the Messag es, 
    Total in All Mailb oxes field .0 to 999999.  5000 
    Sub sc ribers, Loc al Maximum numb er of local 
    sub sc rib ers that can be 
    administered  on this DEFINITY 
    A U D I X Sy st e m1 to 100000 1000
    Sub sc r i b e r s,  
    Administered  
    Rem ot eMaximum numb er of remote 
    administered  sub sc rib ers that this 
    DEFINITY AUDIX System c an 
    acc ommod ate0 to 50000000 1000
    Lists, Total Entries Total number of entries allowed in all 
    sub sc rib ers’ lists0 to 999999 50000 
    Lists/Sub sc rib ers Maximum numb er of lists allowed  
    per subscribers0 to 999 100 
    Rec ipients/List Maximum numb er of entries 
    (rec ipients) allowed p er sub scrib er 
    list0 to 250 250 
    Administration Log  
    Ent r i esMaximum numb er of ad ministration 
    log  entries. When the maximum is 
    reac hed , the oldest entries are 
    removed to make room for the 
    newest.1 to 2000 1000  
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-222 display System-Parameters Link-Log (CL Mode) 
    3
    display System-Parameters Link-Log 
    (CL Mode)
    The System-Parameters Link Log sc reen is used  to ad minister the link log , 
    inc lud ing  enabling  or d isab ling  the link-log  d ata c ollec tion, enab ling  or d isab ling 
    the log g ing  of MWI up d ates, setting  the maximum numb er of link-log  entries, and  
    c learing  the link log. 
    display system-parameters link-log 
    change system-parameters link-log 
    NOTE:
    The activation commands for this sc reen can be executed by users with 
    craft or hig her-level log in p ermissions. 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-223 display System-Parameters Link-Log (CL Mode) 
    3
    Field Descriptions
    Name Description Valid Entries Default
    Link Log  Enab led ? Enab les link log d ata c ollec tion. If 
    enab led , record s are written to the 
    log. If disabled, records are not 
    written to the log .y (link log  d ata 
    collec tion is enab led ) 
    n (link log d ata 
    collec tion is halted)n 
    Maximum Numb er of 
    Link Log  EntriesSpec ifies the maximum number of 
    rec ords in the link-log  file1 to 5000 5000 
    !WA R N I N G :
    Red ucing the maximum numb er of entries will c ause the link log  to b e c leared . 
    Clear All Entries in 
    Link Log ? Spec ifies whether the entries in the 
    link log  will b e resety (p ressing   (Enter) 
    clears the link log ) 
    n (has no effect)nF3 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-224 display System Parameters Maintenance 
    3
    display System Parameters 
    Maintenance
    The System Parameters Maintenanc e sc reen is used to d efine system 
    p arameters related to installation and  maintenanc e, inc lud ing  system serial 
    numb er, name, loc ation, alarm rep orting  telep hone numb er, and  other 
    maintenanc e features. 
    display system-parameters maintenance 
    change system-parameters maintenance 
    You c annot make c hang es using  this sc reen while an alarm c all is in p rog ress. 
    NOTE:
    Th e  change system-parameters maintenance
     c ommand  c an b e 
    exec uted  by users with 
    craft or hig her-level log in p ermissions. This sc reen 
    c an b e ac tivated  while the DEFINITY AUDIX System is in the OA&M state. 
    The System Parameters Maintenanc e
     sc reen has two p ag es. 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-225 display System Parameters Maintenance 
    3
    Field Descriptions
    Name Description Valid Entries Default
    PA G E  1
    Prod uct 
    Identification 
    Numb erNumb er b y which this DEFINITY AUDIX 
    System is known to the Op erational 
    Su p p o r t Sys t em  ( OSS) .  Thi s f i el d  i s 
    required  if an entry is made in the 
    Automatic Alarm Rep orting Telephone 
    Numb er field  on this screen.blank 10 digit integer 
    b eginning with the d ig it 2blank 
    Mac hine 
    Network 
    NameDesc rip tive name for the DEFINITY 
    AUDIX System, d efined  on the Mac hine 
    screenname of up  to 8 
    alp hanumeric  charac tersaud ix
    display 
    only
    System 
    Loc ationDesc rip tive loc ation name for the 
    DEFINITY AUDIX Systemname of up  to 30 
    alp hanumeric  charac tersblank
    Manual 
    Trouble 
    Reporting 
    Numb erTelephone number to manually rep ort 
    DEFINITY AUDIX troub les (normally the 
    AUDIX help line). Defaults to 
    1-800-56AUDIX, if c alling  from within 
    the USAnumb er of up  to 30 d igits 
    (and /or letters)  
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-226 display System Parameters Maintenance 
    3
    Automatic  
    Alarm 
    Reporting 
    Telep hone 
    Numb erMod em command  string  for automatic  
    alarm referral c alls g enerated  b y this 
    DEFINITY AUDIX System
    Multip le c ommas (,) may b e used  for a 
    g reater d elay time. If d ialing  from the 
    internal tip/ring modem port, ATDT 
    must b e the first c harac ters in the dial 
    string. If using an MPDM, B must b e the 
    first charac ter in the d ial string . For 
    examp le, to d ial 9, p ause, and  dial a 
    numb er on the tip /ring  p ort, enter 
    ATDT9,1234567. 1 to 65 
    alp hanumeric -c harac ter 
    c omp lete mod em 
    c ommand string 
    (inc lud ing  a c ommand 
    p refix suc h as ATDT, if 
    req uired ),
     (Pause, tip /ring  default 
    p ause =  2 sec ond s)
    B (send a 
    break to an 
    MPDM)
    AT (command  the 
    internal tip /ring  mod em 
    port
    DT (dial on the internal 
    tip/ring modem port)blank 
    Rem ot e  
    Mod em 
    Initialization 
    Str i n gInitialization string req uired  to set 
    p rotoc ols that will allow DEFINITY 
    AUDIX System to c ommunic ate with the 
    external mod em.For the US Rob otic s 
    Sp ortster 33.6:
    at&f0e1x4&a3&b1&k0&n
    6&u2s0= 1s13= 1y0&w0
    For the Parad yne 
    Comsphere mod els 3810 
    and  3820:
    at&f0e1b 0x6y0&d 2&t5\k1
    \q 0%c 0” h0s41= 3s49= 0s
    55= 1&w0
    For the Parad yne 
    Comsphere mod el 3910:
    at&f0e1x6y0&d 2&t5\k1\q
    0%c 0”h0s41= 3s49= 0s55
    =1&w0
    In the initialization string , 
    the letters must b e all 
    c ap italized or all lower 
    case.
    If you have a mod em 
    other than the ones listed  
    ab ove, see
     Installation 
    and  Switc h 
    Ad ministration for the 
    DEFINITY AUDIX System 
    Release 4.0,
     
    585-300-122.at&f0e1x4
    &a3&b 1&k
    0&n6&u2s
    0= 1s13= 1y
    0&w0
    Alarm 
    Origination 
    Rem ot e  
    Acc ess Port 
    Baud  RateBaud  rate used  when orig inating  an 
    outg oing  alarm call1200, 2400, 4800, 9600. 
    System 
    NOTEsUsed  to enter NOTEs ab out this 
    system, suc h as installation dates, 
    up grad e spec ifications and  d ates, 
    hard ware rep lacement rec ord sup  to four 80 charac ter 
    lines of alphanumeric  
    c haracterblank  Name Description Valid Entries Default 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-227 display System Parameters Maintenance 
    3
    PAGE 2 
    Alarm 
    Origination 
    Active?Sp ec ifies whether or not Alarm 
    Orig ination is active on this DEFINITY 
    AUDIX System. Alarm Orig ination 
    allows AUDIX to call an Operation 
    Supp ort System (OSS) when a major or 
    minor alarm oc curs.
    When this field is set to n, no Alarms 
    Resolved notific ation is sent b y the 
    DEFINITY AUDIX System, and  no alarm 
    c alls are not sent for alarms occ urring .y (ac tivate alarm 
    orig ination) 
    n (deactivate alarm 
    orig ination) n 
    All Alarms 
    Res ol v ed  
    Notific ation?Sp ec ifies whether All Alarms Resolved  
    Notification is enab led  on this DEFINITY 
    AUDIX System. If enab led , after all 
    acknowled g ed major and minor alarms 
    are resolved, the DEFINITY AUDIX 
    System send s an all-c lear messag e to 
    the Op erations Supp ort System (OSS). 
    This field  is not effec tive if Alarm 
    Orig ination is not active.y (enab le all alarms 
    resolved notific ation) 
    n (disab le all alarms 
    resolved notific ation)n 
    Alarm Ac tion Alarm ac tion for major & minor alarms 
    for each alarm category. call or none 
    for each alarm type (major or minor) for 
    eac h alarm categ ory. Relay and  b oth 
    for major alarms only for each alarm 
    category.
    If Alarm Orig ination is not active then 
    the both and  call are affected  as 
    follows. If both was spec ified , the 
    DEFINITY AUDIX System op erates only 
    the relay c ontact closure. If call was 
    spec ified  and  if the failure mod e in the 
    Close Contac ts on Alarm Orig ination 
    Failure field  ind icates that the c ontact 
    c losure should  b e op erated, this occ urs 
    within 5 minutes. Otherwise nothing is 
    done. mand atory inp ut field s 
    relay (op erate only the 
    c ontact closure relay)
    c all (p lace only an 
    alarm-origination call)
    b oth (p erform b oth 
    actions)
    none (perform neither 
    action)call
    NOTE:
    Alarm origination c annot b e activated  unless the Prod uct ID Number and  
    Automatic  Alarm Rep orting  Telep hone Numb er field s are filled  in. 
    Close 
    Contacts on 
    Alarm 
    Origination 
    Failure?Sp ec ifies whether to op erate relay 
    c ontact c losures when alarm orig ination 
    fails for major alarms with call sp ec ified.y (op erate relay-contac t 
    c losures) 
    n (do not op erate 
    relay-c ontact c losures)y 
    Maximum 
    Numb er of 
    Event Log  
    Ent r i esMaximum numb er of entries in the 
    event log .1 to 30000 10000  Name Description Valid Entries Default 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-228 change/display System-Parameters Outcalling 
    3
    change/display System-Parameters 
    Outcalling
    The System-Parameters Outc alling sc reen is used  to ad minister the 
    system-related  outc alling  p arameters. Outc alling  alerts sub sc rib ers when new 
    messages are received, by placing a call to a number specified by the 
    sub sc rib er. The outc alling  p arameters also affec t the AMIS Analog  Networking 
    and  Messag e Delivery features. This feature uses voic e p ort resourc es. 
    display system-parameters outcalling 
    change system-parameters outcalling 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies Definity Audix System Release 4.0 Screens Reference Manual