    Have a look at the manual Lucent Technologies Definity Audix System Release 4.0 Screens Reference Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-179 display Switch-Link (DS Mode) 
    3
    display Switch-Link (DS Mode)
    The system installer uses the Switch Link Embedded sc reen to d efine the 
    integ ration method  b etween the switc h and  the DEFINITY AUDIX System. This 
    sc reen is ac tive when the DEFINITY AUDIX System is running  in the Disp lay Set 
    (DS) switc h integ ration mod e (DS uses an eig ht p ort b oard ), as spec ified  on the 
    System-Parameters Customer Op tions sc reen. A different version of this sc reen 
    is ac tive for the CL mod e. The sc reen-ac tivation c ommand s are the same for 
    both modes. 
    display switch-link 
    change switch-link 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-180 display Switch-Link (DS Mode) 
    3
    Field Descriptions 
    Name Description Valid Entries Default
    Host Switch Switc h numb er assig ned  to the host 
    switc h1
    NOTE:
    The host switch numb er should not b e c hang ed  after installation. If 
    the host switch number is chang ed after installation, the switc h 
    numb er on the Sub sc rib er sc reen must b e c hang ed  to matc h this 
    numb er for all sub scrib ers; then a switc h translations aud it must be 
    run or the system must b e restarted .
    AUDIX DEFINITY AUDIX machine number 1 to 99 1
    Time out PARAMETERS
    Call Answer Time out Numb er of seconds the system waits 
    b efore assuming  that no touch-tone 
    d ig its will be entered  by the caller. 
    When the DEFINITY AUDIX System 
    answers a c all without rec eiving a 
    c onnec t messag e, the c all is 
    assumed  to b e c all answer rather 
    than voic e mail. When the Time out 
    number is exceeded , the sp ec ified 
    Time out treatment is used . 0 to 99 5 
    Time out Treatment Spec ifies how c alls are handled 
    when the c all answer Time out period  
    exp iresnone (d isc onnec t the 
    call)
    mailb ox (transfer to 
    the sp ec ified 
    mailb ox) transfer 
    (transfer to the 
    sp ec ified extension) none
    NOTE:
    Since some callers use rotary telephones and  will b e 
    unab le to make a selec tion, it is strong ly recommend ed  
    that the mailbox or transfer op tion b e used . 
    Extension Extension or the mailb ox dep end ing  
    on entry in the Time out Treatment 
    field) to which c alls are transferred  if 
    the call-answer Time-out period  has 
    exp ired3 to 10 d ig it 
    extension numbers. 
    blank (only if the Time 
    out Treatment is 
    none.)
    NOTE:
    If mailb ox is entered  in the Time out Treatment field, this 
    field  must identify a valid  DEFINITY AUDIX subsc rib er.  
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-181 display Switch-Link (DS Mode) 
    3
    busyout Switch-Link 
    The Busyout/Release Switc h Link sc reen is used  to b usyout or release the switc h 
    link and  to d isp lay the results of the b usyout or release op eration. 
    busyout switch-link 
    release switch-link 
    Field Descriptions 
    Name Description (display only)
    Resourc e Name of the ob jec t being b usied -out or released . For this sc reen, the 
    resourc e value is SWITCHLINK.
    Loc ation Loc ation of the switc h link b eing  b usied -out or released , in the 
    format, p ort network, c arrier, slot, and  p ort; for examp le, 01a0202
    State State of the switc h link:
    ISP (in servic e p end ing )
    ISB (in servic e and busy)
    OOS (out of servic e) 
    Reason If the switc h link is out of servic e (OOS), this field  ind ic ates the 
    reason:
    C (manually b usied  out, b y c raft)
    T (test in p rog ress)
    F (taken out of servic e b y maintenanc e and  the switc h link is 
    alarmed ) 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-182 display Switch-Link (DS Mode) 
    3
    status Switch-Link
    The Status Switc h Link sc reen is used  to d isp lay the status of the switc h link. 
    status switch link 
    NOTE:
    This sc reen c an b e ac tivated  while the DEFINITY AUDIX System is in the 
    OA&M state. 
    Field Descriptions 
    Name Description (display only)
    Typ e Typ e of switc h link c urrently ad ministered
    Baud Transmission rate for the switc h link (9600-19200)
    Loc ation Loc ation of the switc h link in the format, p ort network, c arrier, slot, 
    and  port id ; for examp le, 01a0202
    State Possib le switc h link states:
    ISP (in servic e p end ing : in servic e and  not alloc ated  for testing ; all 
    switc hes are out of d ata transfer.)
    ISB (in servic e and busy: in servic e and being used  for normal 
    op eration; at least one switc h is in d ata transfer)
    OOS (out of servic e: the switc h link is out of servic e for the reason 
    spec ified  in the “ reason”  field ) 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-183 display Switch-Link (DS Mode) 
    3
    Reason Possib le out of servic e reasons:
    C (manually b usied  out, b y c raft)
    T (test in p rog ress)
    F (a fault on the switc h link. All lines are d own.)
    FSW word s - level 
    13Failure status word for levels 13 of the switc h link
    FSW Level       Bits Used
    FSW 1               Bits 0-2 g ive the level 1 state:
                                0 - Carrier Detec t
                                1 - Clear To Send
                                 2 - Data Set Read y
    FSW 2               Bits 04 g ive the level 2 state.
    FSW 3               Bits 02 g ive the level 3 restart state.
    DCIU switc hes 
    (In/Out of d ata 
    transfer)Data transfer state for up  to 20 switc hes:
    I (In data transfer)
    O (Out of Data Transfer)
    b lank (Switc h is unassig ned )
    Counters
    Counter for the switc h-link protoc ol stack. 
    Counters         For
    1 - 6                 Level 1
    7 - 21               Level 2
    22                    Switc h no. for next 10 c ounters
    23 - 32             Level 3
    33                    Switc h no. for next 10 c ounters
    34 - 43             Level 3
    44                    Switc h no. for next 10 c ounters
    45 - 54             Level 3
    55                    Switc h no. for next 10 c ounters
    56 - 65             Level 3
    Name Description (display only) 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-184 display Switch-Link (DS Mode) 
    3
    test Switch-Link Long (CL Mode)
    Th e  Sw it c h - L i n k Test Results sc reen initiates a d emand  test of the 
    AUDIX-to-switc h d ata link and  d isp lays the result of the test. 
    test switch-link long
     
    If long
     is sp ec ified , a test of the c omp lete p ath to the switc h is p erformed . 
    test switch-link looparound
     
    If looparound
     is sp ec ified , a test to an external loop b ac k p lug  is p erformed . 
    NOTE:
    The activation commands for this sc reen can be executed by users with 
    craft or hig her level login p ermissions. This sc reen c an b e ac tivated  while 
    the DEFINITY AUDIX System is in the OA&M state. 
    Field Descriptions 
    Name Description (display only)
    Date Date and  time the test was invoked
    Resourc e This field  d isp lays the name of the ob jec t b eing  tested . For this 
    sc reen, the resourc e value is SWITCHLINK
    Loc ation Loc ation of the switc h link in the format, p ort network, c arrier, 
    slot, and  p ort id ; for examp le, 01a0202
    Te s t  N a m e Te s t  N a m e 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-185 display Switch-Link (DS Mode) 
    3
    Sample Tasks
    To p erform a c omp lete test of the AUDIX-to-switc h d ata link: 
    1. Type test switch link long
     and  p ress   (Enter). 
    2. Press   (Enter) to start the test, or   (Canc el) to return to the c ommand  
    line without exec uting  the test. 
    While the test is running , you have three op tions: 
    1. Press   (Canc el) to ab ort the test and  return to the c ommand  line. 
    2. Wait for the test to c omp lete. 
    3. Press   (Enter) to p ut the test in the b ac kg round  and  return to the 
    c ommand  line. 
    Ty p e  status test
     to rec onnec t to the sc reen of a test running  in b ac kg round , or to 
    d isp lay the results of the most rec ently c omp leted  test. 
    To p erform a looparound  test of the switc h link: 
    1. Type test switch-link looparound
     and press   (Enter). 
    2. Press   (Enter) to start the test, or   (Canc el) to return to the c ommand  
    line without exec uting  the tests. 
    While the test is running , you have three op tions: 
    1. Press   (Canc el) to ab ort the test and  return to the c ommand  line. 
    2. Wait for the test to c omp lete. 
    3. Press   (Enter) to p ut the test in the b ac kg round  and  return to the 
    c ommand  line. 
    Ty p e  status test
     to rec onnec t to the sc reen of a test running  in b ac kg round , or to 
    d isp lay the results of the most rec ently c omp leted  test.  Most Rec ent Test Result Result of the most rec ently run test. The first field  d isp lays one 
    of the following  c harac ters — R (for test running ), P (for test 
    p assed ), F (for test failed ), or A (for test ab orted ). The sec ond  
    field  c ontains up  to 20 c harac ters of ad ditional information on 
    the most rec ently run test. 
    Test Counters
    Pa s sNumb er of times the test has p assed  sinc e test c ommand  was 
    exec uted. 
    Fa i lNumb er of times the test has failed  sinc e test c ommand  was 
    exec uted. 
    Ab ortNumb er of times the test has ab orted  sinc e test c ommand 
    was executed. 
    Name Description (display only)
    F3
    F3F1
    F1
    F3
    F3
    F3F1
    F1
    F3 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-186 audit Switch-Names (DS Mode) 
    3
    audit Switch-Names (DS Mode)
    When the DEFINITY AUDIX System is running  in DS mod e, the Aud it Results 
    sc reen initiates a d emand  aud it on eac h sub sc rib er’s name and  d isp lays the 
    aud it results. This aud it c reates a d irec tory of extensions and the name 
    assoc iated  with eac h extension on the switc h. 
    audit switch-names
     
    NOTE:
    This screen is not accessible in CL mod e.
    Field Descriptions
    Name Description (display only)
    Date Date that the aud it was req uested
    Time Time that the aud it was req uested
    Aud it Name Name of the aud it being run
    Result 1 c harac ter c od e that ind ic ates the last result of the named  aud it, 
    and  up  to 20 c harac ters of text of ad d itional aud it-result information.
    blank (audit not exec uted)
    R (audit is running )
    P (last audit p assed )
    F (Last aud it failed )
    A (Last audit aborted) 
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-187 display Switch-Time-Zone 
    3
    display Switch-Time-Zone
    The Switc h Time Zone sc reen is used  to assign a time zone for the host switc h. 
    display switch-time-zone 
    change switch-time-zone  
    						
    							DEFINITY AUDIX System Release 4.0 Screens Reference  585-300-213  Issue 1
    May 1999
    Screen Descriptions 
    3-188 display Switch-Time-Zone 
    3
    Field Descriptions
    NOTE:
    When you c hang e the switc h time zone, you must reb oot for the c hang e to 
    take effec t. After reb ooting  verify that the switc h and  DEFINITY AUDIX times 
    are sync hronized . If they are not, resync hronize the times b y ac c essing  the 
    SET TIME
     sc reen and  selec ting  the synchronize to switch
     field .
    Name Description Valid Entries Default
    Time Zone Time zone numb er in whic h 
    the assoc iated  switc h is 
    loc ated . The time zone 
    numb er is the numb er of 
    hours d ifferenc e (measured  
    during standard time) 
    b etween the time zone of the 
    switc h and  universal 
    c oord inate time (formerly 
    c alled  Greenwic h mean time), 
    measured  east to west. b lank
    0 to 23
    4 (Atlantic  Stand ard  
    Ti m e )
    5 (Eastern Standard 
    Ti m e )
    6 (Central Stand ard  
    Ti m e )
    7 (Mountain Stand ard  
    Ti m e )
    8 (Pac ific  Stand ard 
    Ti m e )
    9 (Alaska)
    10 (Hawaii)5
    Daylig ht Saving s? Ind ic ates whether the 
    assoc iated  switc h is in a time 
    zone that imp lements d aylig ht 
    saving s time from Ap ril to 
    O c t o b e r.  Th e  D EFI N I TY 
    AUDIX System ad justs its time 
    rec ord s ahead  b y one hour in 
    Ap ril and  b ac k ag ain in 
    Oc tob er for a switc h with a y 
    in this field . y (d aylig ht saving s time 
    is implemented in this 
    time zone) 
    n (d aylig ht saving s time 
    is not imp lemented  in 
    this time zone)y
    Host Switc h Numb er assig ned  to the host 
    switc h. This no. is the no. of 
    the switc h in whic h the system 
    is embedded. A reboot is 
    required if the time zone of the 
    host switc h is c hang ed . (Use 
    the Switc h Link sc reen to 
    change the host switc h.) d isp lay only field 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies Definity Audix System Release 4.0 Screens Reference Manual