Have a look at the manual Lucent Technologies Definity Audix System Release 4.0 Screens Reference Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Organization 2-23 Screen Commands 2 Status Test
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Organization 2-24 Screen Commands 2
Screen Descriptions 3-1 3 DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 3 Screen Descriptions This c hap ter c ontains d esc rip tions of the sc reens arrang ed in alphab etic al ord er b y sc reen name. The sc reen name ap p ears at the b eg inning of eac h sc reen d esc rip tion. The c ommand s for eac h sc reen ap p ear b elow eac h head ing . Eac h sc reen d esc rip tion c ontains the following : nBrief d esc ription of what the sc reen d oes nCommand(s) used to ac c ess the sc reen nInformation p ertaining to sc reen p ermissions or other c ommand restric tions (if ap p lic ab le) NOTE: Most sc reens req uire only the cust log in. If a sc reen req uires craft or init log in, or has some other sp ec ific req uirement, that is noted in the sc reen d esc rip tion. nScreen example nField descriptions nSamp le task (for more c omplic ated sc reens) nAd d itional sp ec ific ations (op tional) More complicated commands, such as audit , save , reset , restore , and test have a Sample Tasks sec tion that illustrates how to use the sc reen.
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-2 display Activity-Log 3 display Activity-Log The Ac tivity-Log Rep ort sc reen d isp lays entries in the ac tivity log that c orresp ond to the sub sc rib er extension entered on the c ommand line. This sc reen may take several minutes to exec ute d ep end ing on the system load and the size of the log file. display activity-log extension Th e extension is a 3 to 10 d ig it extension of the loc al sub sc rib er whose ac tivity log is being displayed. The Ac tivity-Log Report sc reen has two p ag es. The first pag e d isp lays the extension entered on the c ommand line and the c orresp ond ing sub sc rib er’s name. If you want to view sp ec ific ac tivity log entries, enter the d ate and time for the start of the ac tivity-log entries on the first p ag e. The sec ond p ag e d isp lays the ac tivity-log entries. Press (Next Pag e) to view a next p age. F7
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-3 display Activity-Log 3 Field Descriptions Field Name Description Valid Entries Default Page 1 Sub sc r i b e r Ext en s io nExtension entered on the c ommand line.d isp lay-only field Sub sc riber Name Name of the sub sc rib er c orresp ond ing to the extension entered on the command line.d isp lay-only field Starting Date Month Starting month for the ac tivity log report.blank 1 to 12blank or month last entered NOTE: If the starting month is blank, all starting d ate and time fields must be b lank. This displays the earliest availab le d ata for this subscrib er. If end ing month is non-b lank, the d ay and year fields must be non-b lank. Starting Date Day Day of the g iven month the activity log report should begin.blank 1 to 31blank or d ay last entered Starting Date Year Year the ac tivity log rep ort should b eg in. A year < 70 is assumed to b e in the 21st century. blank 1 to 99blank or year last entered
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-4 display Activity-Log 3 Starting Time Hour Starting hour of the ac tivity log rep ort. blank 0 to 23 blank or hour last entered Starting Time Minute Starting minute of the ac tivity log rep ort. If the hour field is non-b lank, this field must b e non-b lank.blank 0 to 59blank or minute last entered End ing Date Month End ing month for the ac tivity log rep ort.blank 1 to 12current month NOTE: If the ending month is b lank, all ending d ate and time field s must be blank. This makes the end ing date and time the current d ate and time. If the ending month is non-b lank, the d ay and year field s must be non-blank. End ing Date Day Day of the g iven month the activity log report should end.blank 1 to 31current day End ing Date Year Year the ac tivity log rep ort should end . A year < 38 is assumed to b e in the 21st c entury. blank 0 to 37 90 to 99current year End ing Time Hour End ing hour of the ac tivity log rep ort.blank 0 to 23current hour End ing Time Minute End ing minute of the ac tivity log rep ort. If the ending hour field is non-b lank, this field must b e non-b lank.blank 0 to 59current minute PAGE 2 The following fields are disp lay only. DATE Date that the ac tivity was logged. TIME Time that the ac tivity was logged. ACTIVITY Activity identifier for each activity-log entry. The ac tivity id entifier is a 5- to 9-c harac ter string ind icating the ac tivity.log-in, log-off, rec eived , scheduled, c anc eled , status, mwi-on, mwi-off, or reset. DESCRIPTION Desc rip tion of the ac tivity-log entry. Field Name Description Valid Entries Default
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-5 list Address-Ranges 3 list Address-Ranges The Ad d ress Rang es sc reen d isp lays a numeric al list of ad d ress rang es that b elong to all mac hines in the network. list address ranges Disp lays all rang es list address ranges starting address Disp lay beg ins with the starting address. If the starting address inc lud es alphab etic c harac ters, they are c onverted to their Touc h-Tone numeric eq uivalent. For examp le, the ad dress D2000 would be 32000. NOTE: This sc reen c an b e ac tivated only if the AMIS analog networking feature or d ig ital networking feature has b een ac tivated on the System-Parameters Customer Op tions sc reen b y Luc ent Tec hnolog ies p ersonne l. Field Descriptions Field Name Description (display only) From Starting add ress of the ad d ress rang e. To End ing add ress of the ad dress range. Machines Mac hines for this add ress rang e (up to 16 mac hines for eac h rang e).
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-6 display Administration-Log 3 display Administration-Log The Administration Log screen displays problems that can be solved by the ad ministrator. NOTE: The ad ministrator should monitor this log on a reg ular basis and c orrec t the problems promptly. See Appendix A for a list of possible ad ministration-log entries and sug g ested remed ial ac tions. display administration-log The Administration Log sc reen has two p ages as shown below. The first p ag e of the sc reen is used to selec t the ad ministration alarm-entries to b e d isp layed in the rep ort. To d isp lay all alarms from the b eginning of the log file, blank all field s on the first p ag e using the (Clear Field ) key. To selec t a sub set of alarm entries to b e d isp layed , enter values in the Start Date, Time, and /or Typ e field s. F4
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-7 display Administration-Log 3 The sec ond p ag e d isp lays the selec ted alarms. Press (Next Pag e) to move to the next p ag e of the list.F7
DEFINITY AUDIX System Release 4.0 Screens Reference 585-300-213 Issue 1 May 1999 Screen Descriptions 3-8 display Administration-Log 3 Field Descriptions Additional Specifications Appendix A c ontains a list of p ossib le ad ministration log entries and sug g ested remed ial ac tions. Field Name Description Valid Entries Default SELECTION PAGE The first time this sc reen is used after installation, the field s on the selec tion p age are b lank. This sc reen-last-used d ate and time are p reserved ac ross restarts. Start Date Beg inning d ate for the log rep ort. Any year < 70 is assumed to b e the 21st c entury.blank (displays all q ualifying alarms) d ate in mm/d d/yy format d ate last entered Time Beg inning hour and minute of the given day for the log report. The Start Date field must have valid entries b efore this field c an b e used . b lank (d isp lays all alarms for the sp ec ified Start Date) hh:mm formattime last entered Typ e Ad ministration alarm type the rep ort should d isp lay. Refer to Ap pendix A for valid ad min. alarm typ es. b lank (rep orts all admin. alarm typ es). four alphanumeric c harac ters. If this field c ontains an alarm typ e, alarms of only that type are displayed.b lank DISPLAY PAGE The Ad ministration Log Rep ort d isp lays the following field s for eac h alarm: Date Date the ad min. alarm was log ged . Time Time on the g iven d ate the admin. alarm was log ged . Typ e Four-charac ter c od e rep resenting the ad min. alarm typ e. Refer to Appendix A for valid ad min. alarm typ es. Alarm Desc rip tion of the admin. alarm, two lines for each alarm.