    							Programming3-21
    Chapt er 3 - Key Station Featu res , Opera tion , an d Programmin g
    Table 3-6: S ta tion Application Programming Table
    S T A T I O N APPL ICATI ON R an ge De fa ul t De scri pti on
    1.
    UCD PROGRAMM ING
    UCD Group 1-24 24 UCD groups are a llowed in the system.
    Te nant 1-6 1 T he tena nt group to which the UCD group is
    assigned.
    UCD Attri b UCD/VA UCD T his de fi ne s the hunt group ty pe.
    2.
    UCD GROUP M EMBER
    Me mb er Any v alid s tation
    numbe rEach UCD group may has 24 members in it.
    Hunt Me thod Line /Dist/A ll Line T here a re 3 hunting me thods al lowe d: Li near
    ( LINE ) Dis tributed DIS T ) A ll Ring (A LL) .
    No Ans Tim e 5-6 0 1 0 T his option de fine s the length of time a call
    will ring a m em ber of the group be fore
    a dvancing to the ne xt me mb er.
    O ver 1 Tim er 0-255 0 T his tim er dete rmine s the le ngth of ti me that
    a ca ll will ring in the UCD group be f ore being
    transferred to the ov erflow 1 de stina ti on I f
    the time r is s et to 0 the n it wil l not ove rf low
    to the ove rf low 1 des tination.
    Ov er 1 D es t N u ll T h is is t h e ov er f lo w 1 des t in at io n an d c an be a ny
    va lid s ta tion numbe r or a nother UCD group.
    Ov er 2 Tim er 0 -25 5 0 T his is the s am e as the ove r 1 tim er exce pt it
    overflows to the over 2 destination.
    Ov er 2 D es t N u ll S am e as o ver 1 des t in at io n .
    Ov er Counter 1 -12 8 1 T his option de fine s how ma ny time s a
    u n a n sw er ed c all c yc le s t o t h e ov er f lo w 2
    de stina tion before going to the re route
    de stina tion.
    Re route Des t Null T his option de fine s the fi nal des tination f or
    una nsw ered c alls to a group. This option is
    used only whe n:
    †No overflow 2 destination is defined a nd
    the cal l re ma ined una nswere d by
    des tination 1 .
    †T he ca ll rem aine d una nswere d by the
    overflow 2 destination after the overflow
    count ha s e xpired.
    T he reroute can be a ny exte nsi on or anothe r
    UCD group. 
    						
    							3-22Programming
    Ch apter 3 - Key Station Featu res , Operation , an d P rog rammin g
    3.
    VOIC E MA IL
    VM Hunt Group 0/1-24 0 T he voice mail ports must be programmed in
    auniqueUCD group.TheVMHUNTgroup
    a nd the UCD groups m ust be the same
    group ( i.e: VM hunt group 1 = UCD group 1).
    Prefix Table T here a re 10 pre fix ta ble s that can be se nt to
    the VM in certa in conditions. The pref ix
    code s a re up to 4 digits in length a nd can
    includ e 0-9,*, # , a nd Pa use (P).
    ICM /VM Null T his pref ix is s ent to the VM prior to the us e r’s
    e xtension numbe r whe n check ing me ssage s.
    Trans f er Null T his pref ix is s ent to the VM prior to the us e r’s
    e xtension numbe r whe n a cal l is transfe rred
    dire ctly to the m ailbox.
    Dire ct Fwd. Null
    Bus y Fw d. Null T his pref ix is s ent to the VM prior to the us e r’s
    e xtension numbe r whe n the transferred ca ll
    goes to an extension that is in a busy call
    forward mode to the VM group.
    No_A ns F wd. Null T his pref ix is s ent to the VM prior to the us e r’s
    e xtension numbe r whe n the transferred ca ll
    goe s to an e xtension that is in a no answe r
    forward mode to the VM group.
    DND Fwd. Null T his prefix is sent to the VM prior to the use r’s
    e xtension numbe r whe n the transferred ca ll
    goe s to an e xtension that has DND enabl ed
    to the VM group.
    LN Re call Null
    UCD Ov erflow Null T his pre fix is sent to the VM prior to the UCD
    group transferring a ca ll from overflow to the
    VM group.
    Record Dgt Null
    Cle ar Ms g
    ICM Suf fix
    XF ER Suf fi x Null
    DIS Digit Null
    Table 3-6: S ta tion Application Programming Table
    S T A T I O N APPL ICATI ON R an ge De fa ul t De scri pti on 
    						
    							Programming3-23
    Chapt er 3 - Key Station Featu res , Opera tion , an d Programmin g
    Table 3-7: Line Application Programming Table
    L I N E APPLICATION Range Default Description
    1.
    TRUNK ROUTE System allows 24 different trunk groups.
    Trunk Route 01-24 - S elect a trunk group number.
    PBXCode 0-9 9 Trunksprogrammed asPBXtype,thePBXcode
    is not subje ct to Toll Re stric tion.
    PCS S endi ng Y/N Y T he pe riodic Clea ring Signa l (PCS ) al lows the
    ca lling party to ha ng-up a nd imm edia tely
    te rminate the CO ca ll.
    Hunt Method S EQL/ RA N/SE QF S EQL De term ines ord er that trunks are sele cted.
    S EQF =lst trunk i n group
    S EQL= sequentia l from last trunk
    RAN= random from la st trunk used
    A lternate Route
    Al ter Route 1/2 - 2 alterna te routes are used when a ll trunk
    routes are b usy.
    Route Numb er 01-24 - E nte r route numbe r use d as alterna te.
    De lete Di gits 0 --9 0 Up to 1 6 digits may be dele ted from d ial string.
    ( May be use d to acces s l ong di stance
    provide rs.)
    Inserte d Digits - - Up to 16 digits may b e inserte d from dial
    s tring. ( May be us ed to acce ss long dista nce
    provide rs.)
    DIR # S WAP 9 T his option rea ss igns the directory num be r f or
    the trunk route .
    Sw ap W ith - - Not program mabl e as this tim e.
    2.
    T1 CAR DSy ste m al low s 24 T1 lines .
    Parameter Set
    Fram ing Type D4 /ES F D4
    Enco de AMI /B8 Z S/ No ne A MI
    Si gnal DT MF/Pulse DTMF
    DID Le ngth 3-10 3
    Dial Tone Y/N Y
    Remote Station
    Le ading Numb er 1- 9 -
    Route Numb er 0-24 0
    ºDe lete Di gits 0--9 0 
    						
    							3-24Programming
    Ch apter 3 - Key Station Featu res , Operation , an d P rog rammin g
    2.
    ºIns erte d Digits - -
    Cha nnel Type
    Show Line 772-795 - E nte r vali d T 1 l ine numb er.
    Cha n Ty pe Loop/Ground/
    DID/I_ E&M /
    W_E&M/NoneLoop
    ANI N/Y N
    Trans Tab As s ign Trans lation Tab le A ss ignme nt
    Show Tenant 1-6 -
    ºTo In c r ea se 0 - 15 0 15 0 ( To lo w er valu e , g o t o D e c r eas e t a ble v alu es )
    ºTo Decrease 150-0 150 (To lower value, go to Increase tabl e val ues.)
    Trans Tab P rog Trans lation Tab le P rogra mm ing
    Show Tenant 1-6 -
    ºInte rce pt 20 1-2 72
    30 1- 3 72
    43 0- 4 53E nte r a va lid sta tion or Hunt group numbe r.
    ºDigit Inte rval 01-99 -
    ºIncom - - Incom ing numbe r
    ºDest - - Hit [chg] then enter desired station or Hunt
    group numb er.
    3.
    IC L IDIn orde r for the IC LID fe ature to ope rate the
    RS2 3 2-1 port mus t be s et f or I CLID. Attenda nt
    program ming ( F# 0) is us ed to e nable the port
    function.
    Line Numbe r Ta b. Cross-refe re nces the trunk dire ctory num ber
    to the num ber provide d from the Call er ID box.
    Sh o w Li n e 70 0- 7 71 -
    Line Numbe r 0 - 72 0
    Table 3-7: Line Application Programming Table
    L I N E APPLICATION Range Default Description 
    						
    							Programming3-25
    Chapt er 3 - Key Station Featu res , Opera tion , an d Programmin g
    Table 3-8: System Application Programming Table
    SYSTEM APPLICATION Range Default Description
    1.
    RING SC HEME 0-4 2
    2.
    L ET TE R TYPE 0-7 0 Not a pplicabl e - do not cha nge.
    3.
    HOUR MODE 12 /2 4 24 Sel ect s tandard or m ilitary ti me.
    4.
    P OS ITI ON TO D IR Exa mple :
    1- 0 4- 0 1= st a t i o n 20 1This s etting is us ed to change s tation/CO line
    numbers per their physical location. Enter
    position as Cab inet/S lot/Port. (Cabine t
    number will always be number 1.)
    Di r Num ber Displa ys DIR num ber of port at spe cif ied
    addres s.
    5.
    DI R TO PO SIT ION Enter va lid DIR numbe r of a s tation/line .
    Posi tion Displa ys physical l ocation of speci fied DIR
    nu m b e r.
    6.
    NUMBE RI NG PLAN
    Trunk Route The 24 trunk route s can be acce ssed using
    the5differentprogrammabledirectory
    nu m b e r s.
    Le ngth 1-4 1 The le ngth of the directory num be r ca n be
    fr o m 1 t o 4 d i g i t s .
    Le ading 1 -4 ( 1-9 ) 9 Any digit 1-9 c an be use d as the lead ing di git
    as long a s it doe s not confli ct with e xisti ng
    nu m b e r s.
    S ta Dir Numbe r Stations can be a cces se d using up to 9
    diff er e n t dir ec t o r y n um be r s.
    Le ngth 2-4 3 The le ngth of the directory num be r ca n be
    fr o m 2 t o 4 d i g i t s .
    Le ading 1 - 4 ( 1- 9 ) 2 and 3 Any digit 1- 9 c an be use d as the lead ing di git
    as long a s it doe s not confli ct with e xisti ng
    nu m b e r s.
    S ta Page Group The 24 Page groups are accessed using the
    following director y numbers.
    Le ngth 2-4 3 The le ngth of the directory num be r ca n be
    fr o m 2 t o 4 d i g i t s .
    Le ading 1 -4 ( 1-9 ) 40 , 41 , 42 Any digit 1-9 c an be use d as the lead ing di git
    as long a s it doe s not confli ct with e xisti ng
    nu m b e r s. 
    						
    							3-26Programming
    Ch apter 3 - Key Station Featu res , Operation , an d P rog rammin g
    6. S ta Hunt Group The 24 UCD groups are a ccesse d using the
    following director y numbers.
    Le ngth 2-4 3 The le ngth of the directory num be r ca n be
    fr o m 2 t o 4 d i g i t s .
    Le ading 1 -4 ( 1-9 ) 43 , 44 , 45 Any digit 1-9 c an be use d as the lead ing di git
    as long a s it doe s not confli ct with e xisti ng
    nu m b e r s.
    S ta Pickup Group The 24 Pickup groups are a ccessed using the
    following director y numbers.
    Le ngth 2-4 3 The le ngth of the directory num be r ca n be
    fr o m 2 t o 4 d i g i t s .
    Le ading 1 -4 ( 1-9 ) 46 , 47 , 48 Any digit 1-9 c an be use d as the lead ing di git
    as long a s it doe s not confli ct with e xisti ng
    nu m b e r s.
    I ndiv Ab br Num ber The indi vidual s pe ed dia l num be rs are
    accessed usingthe following directory
    nu m b e r s.
    Le ngth 2-4 3 The le ngth of the directory num be r ca n be
    fr o m 2 t o 4 d i g i t s .
    Le ading 1 -4 ( 1-9 ) 5 Any digit 1-9 c an be use d as the lead ing di git
    as long a s it doe s not confli ct with e xisti ng
    nu m b e r s.
    C om mon A bbr Numbe r The com mon s pee d dial num bers are
    accessed usingthe following numbers.
    Le ngth 2-4 3 The le ngth of the directory num be r ca n be
    fr o m 2 t o 4 d i g i t s .
    Le ading 1 -4 ( 1-9 ) 6 Any digit 1-9 c an be use d as the lead ing di git
    as long a s it doe s not confli ct with e xisti ng
    nu m b e r s.
    L ine Dir Numb er Each trunk has a unique access num be r tha t
    is acce ss ed by dia ling the follow ing directory
    nu m b e r.
    Le ngth 2-4 3 The le ngth of the directory num be r ca n be
    fr o m 2 t o 4 d i g i t s .
    Le ading 1 -4 ( 1-9 ) 7 Any digit 1-9 c an be use d as the lead ing di git
    as long a s it doe s not confli ct with e xisti ng
    nu m b e r s.
    Table 3-8: System Application Programming Table
    SYSTEM APPLICATION Range Default Description 
    						
    							Programming3-27
    Chapt er 3 - Key Station Featu res , Opera tion , an d Programmin g
    6 . M u si c S o u rc e Th e m u si c c i r c u i t s ar e us e d f o r bac k g ro u n d
    mus ic. T he circuits are a cces se d using the
    follow ing director y numbe r.
    Le ngth 2-4 3 The le ngth of the directory num be r ca n be
    fr o m 2 t o 4 d i g i t s .
    Le ading 1 -4 ( 1-9 ) 8 Any digit 1-9 c an be use d as the lead ing di git
    as long a s it doe s not confli ct with e xisti ng
    nu m b e r s.
    L oud Be ll The loud be ll circuits are ac ce s se d using the
    following director y numbers. The directory
    num be r i s use d in the a nswering position to
    si g n a l a l o u d bel l .
    Le ngth 2-4 3 The le ngth of the directory num be r ca n be
    fr o m 2 t o 4 d i g i t s .
    Le ading 1 -4 ( 1-9 ) 81 Any digit 1-9 c an be use d as the lead ing di git
    as long a s it doe s not confli ct with e xisti ng
    nu m b e r s.
    E xte rnal Pa ger The e xterna l paging circuits are a ccesse d
    us ing the f ollow ing directory num be r.
    Le ngth 2-4 3 The le ngth of the directory num be r ca n be
    fr o m 2 t o 4 d i g i t s .
    Le ading 1 -4 ( 1-9 ) 82 Any digit 1-9 c an be use d as the lead ing di git
    as long a s it doe s not confli ct with e xisti ng
    nu m b e r s.
    V irtual Numb er Not used a t this time .
    Le ngth 2-4 3 The le ngth of the directory num be r ca n be
    fr o m 2 t o 4 d i g i t s .
    Le ading 1 -4 ( 1-9 ) 83 , 84 , 85 Any digit 1-9 c an be use d as the lead ing di git
    as long a s it doe s not confli ct with e xisti ng
    nu m b e r s.
    O perator Code The f ollow ing cod e is us e d to a cces s the
    station program me d as the atte ndant.
    Le ngth 1-4 1 The le ngth of the directory num be r ca n be
    fr o m 1 t o 4 d i g i t s .
    Le ading 1 -4 ( 0-9 ) 0 Any digit 0-9 c an be use d as the lead ing di git
    as long a s it doe s not confli ct with e xisti ng
    nu m b e r s.
    Table 3-8: System Application Programming Table
    SYSTEM APPLICATION Range Default Description 
    						
    							3-28Programming
    Ch apter 3 - Key Station Featu res , Operation , an d P rog rammin g
    6. LCR Code This code is used to a ccess the LCR fea ture
    Le ngth 1-4 1 The le ngth of the directory num be r ca n be
    fr o m 1 t o 4 d i g i t s .
    Le ading 1 -4 ( 1-9 ) 1 Any digit 1-9 c an be use d as the lead ing di git
    as long a s it doe s not confli ct with e xisti ng
    nu m b e r s.
    A ccount Code The code is us ed for enteri ng a ccount code s
    and this code is considered the first digi t of
    the account code.
    Le ngth 1-4 1 The le ngth of the directory num be r ca n be
    fr o m 1 t o 4 d i g i t s .
    Le ading 1 -4 ( 1-9 ) Nul l Any digit 1-9 c an be use d as the lead ing di git
    as long a s it doe s not confli ct with e xisti ng
    nu m b e r s.
    7.
    S U FFI X CODE
    I CM Ring/Voice 1-# * Us ed to s witch be twe en voice and tone
    ri n g i n g .
    DND O verride 1-# 3 Used to override a station in DND.
    C amp O n 1-# 4 Used to cam p on to a sta tion.
    C all Back 1-# # Used to auto-call ba ck a busy sta tion.
    C all Pickup 1-# 6 Us ed to pick up a ringing call in the sa me
    pickup group.
    I ntrus ion 1-# 8 Us ed to intrude on a sta tion be ing calle d. The
    station m ust be programm ed to al low
    intrude and the calle d stati on ne eds to have
    intrus ion ena bled.
    M sg Wa iting 1-# 9 Us ed to s et m es sage wa iting to the s tation
    being ca lled.
    ICM OHVA 1-# 0 N/A.
    Table 3-8: System Application Programming Table
    SYSTEM APPLICATION Range Default Description 
    						
    							Programming3-29
    Chapt er 3 - Key Station Featu res , Opera tion , an d Programmin g
    8.
    ABBR. NO. ASSIGN.
    (Speed Dial)Abbre viate d Numbe ring As signm ent ( use d
    to program sp eed dial location a llocation)
    I ndividua l Pe rs onal s pee d dial b ins
    Show Sta - - Enter station number.
    ºTo Incre ase 0-50 0 Use setting to all ow numb er of spe ed bins
    per station. (Go to next setting to reduce
    nu m b e r. )
    ºTo Decrease 50-0 50 Use setting to all ow number of speed bins
    per station. (Go to previous se tting to
    in c r eas e n u m ber . )
    Common Li st - - System speed bins
    Show Tenant 1-6 - Enter tenant group.
    ºTo Increase 0-1000 100 Use setting to all ow numb er of speed bins
    per tena nt group. (Go to nex t se tting to
    re d u c e n u m b er . )
    ºTo Decrease 1000-0 100 Use setting to all ow number of speed bins
    per tena nt group. (Go to prev ious setting to
    re d u c e n u m b er . )
    9.
    CO L INE COPY The s ys tem a llows f or copy of the line
    fe at u r es fr o m p o r t t o p or t .
    Features copied: Tenant Group, Route, Day &
    Ni ght CO S, Dialing M ode Trunk Type , Call
    Abandon P rivate and A nsw ering P osition.
    I ndividua l Copy - - Used to copy a single line setting to anothe r
    line or line s, one line at a tim e.
    Copy From - - Enter va lid trunk numbe r to b e used as
    te m p l a t e .
    Copy To - - Enter va lid trunk numbe r to b e change d.
    Group Copy - - Copies se ttings f rom indiv idual line to trunk
    group.
    Copy From - - Enter vali d trunk group num ber to be used as
    te m p l a t e .
    Copy To - - Enter va lid trunk group numbe r to be
    changed.
    Table 3-8: System Application Programming Table
    SYSTEM APPLICATION Range Default Description 
    						
    							3-30Programming
    Ch apter 3 - Key Station Featu res , Operation , an d P rog rammin g
    10.
    STATION COPY The system allows fro copy of the station
    fe at u r es fr o m p o r t t o p or t .
    Th is opt ion D OES NOT copy F eat ure key s
    o r D i al N u m be r S w ap pi n g.
    I ndividua l Copy - - Used to copy a single stati on’s se tting to
    another station or stations, one line a t a ti me.
    Copy From - - Enter va lid sta tion numbe r to be use d as
    te m p l a t e .
    Copy To - - Enter va lid sta tion numbe r to be change d.
    Group Copy - - Copies se ttings from an ind ividual station to
    a sta tion p ickup group.
    Copy From - - Enter va lid sta tion numbe r to be use d as
    te m p l a t e .
    Copy To - - Enter va lid sta tion pickup group numbe r to
    be change d.
    11.
    F EATURE CO PY Used to cop y Feature key programming from
    station to station. Must be sa me key se t t ype
    (Ex ecutive /Enha nced).
    CopyFrom - - Entervalidstationnumberwho’s ke ys w ill be
    us e d a s t h e t em plat e.
    C op y To - - Enter va lid sta tion numbe r w ho’sfeature
    keysaretobechanged.
    12.
    NIT E S ERVICE STA Each te nant group may b e assi gned up to 5
    exte nsions to b e used for ni te se rvi ce .
    S how Te nant 1-6 - Enter va lid tena nt group num ber.
    Member (1-5) Up to five members may be assigned to each
    te nant group.
    13.
    SYSTEM TIME
    Year 00-99 0
    M onth 01-12 JA N Pre ss [chg] to scroll though month.
    D a y 0 1- 3 1 01
    Wee kday S UN -S AT S UN Pre ss [chg] to scroll though days.
    Hour 00-23 01
    Minute 01-59 00
    Table 3-8: System Application Programming Table
    SYSTEM APPLICATION Range Default Description 
    						