    Have a look at the manual Panasonic Digital Business System 576 Technical Manual Section 400 Programming online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 664
    							Section 400-Programming FF7: Applications
    576-13-400 DBS 576 (USA) issued 05/20/98
         l     Page 7-5
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appl ications
    FF8Maintenance Introduction
    Appe ndix  A
    Appe ndix  B
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appli cations
    FF8Maintenance Introduction
    Appe ndix A
    Appe ndix B
         
    Notes:
    This 
    Tenant Group assignment can be used for outside notification (for example, Voice Mail 
    automatically calling your pager after receiving a message in your mailbox).
    Related Programming:
           
    VPU Port Tenant Group Assignment
    (all CPCs) - Version 1.0 or higher
    Assign a Tenant Group to each VPU Port (if required).  This Tenant Group 
    assignment will apply during outbound dialing.
    FF7   0   (B11)   01   (01-16)   01   Hold   (1-72)   Hold 
     
    Tenant Group No. 1-72
    default:  1B11: VSSC Card Position --
    B=Cabinet 1-6
    11=Free Slot 11
    NOTE:  Available range dependsVPU Port No.
    on VPU card(s) installed:
    VPU/4 = 01-04
    VPU/8 = 01-08
    VPU/4 + VPU/4 = 01-08
    VPU/4 + VPU/8 = 01-12
    VPU/8 + VPU/8 = 01-16
    
    $
     	&2 % 1!-6
    VPU Port TRS Class Assignment (Day/Night)
    (all CPCs) - Version 1.0 or higher
    Assign a TRS Class (if required) to each VPU Port.
    FF7   0   (B11)   01   (01-16)   02   (0 and 1)   Hold   (1-50)   Hold 
     
    TRS Class No. 1-50
    1=Night mode 0=Day 1&2 mode
    default:  1 B11: VSSC Card Position --
    B=Cabinet 1-6
    11=Free Slot 11
    NOTE:  Available range depends
    on VPU card(s) installed:
    VPU/4 = 01-04
    VPU/8 = 01-08
    VPU/4 + VPU/4 = 01-08
    VPU/4 + VPU/8 = 01-12
    VPU/8 + VPU/8 = 01-16VPU Port No.
    
    $
     	&2 % , 
    						
    							FF7: Applications Section 400-Programming
    Page 7-6
         l     DBS 576 (USA) issued 05/20/98 576-13-400
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appl ications
    FF8Maintenance Introduction
    Appe ndix  A
    Appe ndix  B
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appli cations
    FF8Maintenance Introduction
    Appe ndix A
    Appe ndix B
    Notes:
    This TRS Class assignment can be used for restricting outside notification (for example, whether Voice 
    Mail can automatically call your pager after receiving a message in your mailbox).
    Related Programming:
           
    Notes:
    The default 6 setting in this address (Pad Class 6) is optimal in most systems for hearing messages.
    Related Programming:
    FF1 8: Digital Pad Settings (pg. 1-176)
    VPU Port Digital Pad Class Assignment
    (all CPCs) - Version 1.0 or higher
    Assign a Digital Pad Class to each VPU Port.
    FF7   0   (B11)   01   (01-16)   03   Hold   (1-8)   Hold 
     
    Digital Pad Class No. 1-8
    default:  6 B11: VSSC Card Position --
    B=Cabinet 1-6
    11=Free Slot 11
    NOTE:  Available range depends
    on VPU card(s) installed:
    VPU/4 = 01-04
    VPU/8 = 01-08
    VPU/4 + VPU/4 = 01-08
    VPU/4 + VPU/8 = 01-12
    VPU/8 + VPU/8 = 01-16VPU Port No.
    
    $
     	&2 $/ , 
    						
    							Section 400-Programming FF7: Applications
    576-13-400 DBS 576 (USA) issued 05/20/98
         l     Page 7-7
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appl ications
    FF8Maintenance Introduction
    Appe ndix  A
    Appe ndix  B
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appli cations
    FF8Maintenance Introduction
    Appe ndix A
    Appe ndix B
           
    Notes:
    To specify only one Extension Card, enter the same Cabinet/Slot number in the First and Last positions.
    The total number of extensions included in Card Ranges 1-4 must not exceed 248.
    The defined range cannot include any type of card other than DEC or AEC Extension Cards.  For 
    example, if there’s a Trunk Card installed between Extension Cards, you must define two separate 
    Extension Card ranges in the above address.
    Related Programming:
    Free Slot Assignment (pg. 0-5)     01 (1-6) (01-12) Hold (1-99) Hold
    Card Type Verification (pg. 8-23)     FF8 0 04 1 BSS 00 Hold [01-99 displays]
    Built-In VM:  Service Range Assignment
    (all CPCs) - Version 1.0 or higher
    Assign up to 4 ranges of extensions that will get Voice Mail service.
    FF7   0   (B11)   02   01   (0001-0016)   Hold   (0-6 or 0-12)   Hold 
     
          
    0001=Range #1 First CabinetCabinet 1-6 or Slot 1-12
    default:  0/00  [no assignment]
    0002=Range #1 First Slot
    0003=Range #1 Last Cabinet
    0004=Range #1 Last Slot
    0005=Range #2 First Cabinet
    0006=Range #2 First Slot
    0007=Range #2 Last Cabinet
    0008=Range #2 Last Slot
    0009=Range #3 First Cabinet
    0010=Range #3 First Slot
    0011=Range #3 Last Cabinet
    0012=Range #3 Last Slot
    0013=Range #4 First Cabinet
    0014=Range #4 First Slot
    0015=Range #4 Last Cabinet
    0016=Range #4 Last SlotNOTE #2:  These extension  B11: VSSC Card Position --
    B=Cabinet 1-6
    11=Free Slot 11
    NOTE #1:  The total number of
    extensions defined in Ranges
    #1 thru #4 must not exceed 248.
    numbers will 
    automatically 
    become the Mailbox Numbers - 
    there’s no need to assign
    mailboxes to extensions in FF4
    (FF-Key Feature Assignments).
    The system will automatically
    send the extension number to
    the Voice Mail Unit. First/Last Free Slot Position
    in Range (up to 4 ranges):
    
    $
    
    
    
     	
    $%) &2 	/7 
    						
    							FF7: Applications Section 400-Programming
    Page 7-8
         l     DBS 576 (USA) issued 05/20/98 576-13-400
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appl ications
    FF8Maintenance Introduction
    Appe ndix  A
    Appe ndix  B
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appli cations
    FF8Maintenance Introduction
    Appe ndix A
    Appe ndix B
           
    Notes:
    See 
    Section 510: Built-In Voice Mail Reference Manual for the addresses contained within this portion 
    of programming.
    Related Programming:
    Built-In VM:  Detail Settings
    (all CPCs) - Version 1.0 or higher
    This is the gateway for entering detailed settings for Built-In Voice Mail.
    FF7   0   (B11)   03   Hold   CONF...
     
     
    B11: VSSC Card Position --
    B=Cabinet 1-6
    11=Free Slot 11
    $
     	&2 ,  
    						
    							Section 400-Programming FF7: Applications
    576-13-400 DBS 576 (USA) issued 05/20/98
         l     Page 7-9
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appl ications
    FF8Maintenance Introduction
    Appe ndix  A
    Appe ndix  B
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appli cations
    FF8Maintenance Introduction
    Appe ndix A
    Appe ndix B
    FF7  1:   Built-In ACD  
    NOTE:  “ACD” means “Automated Call Distributor.”  See Section 520: 
    Built-In ACD Reference Manual for complete instructions on installing, 
    programming, and using this DBS 576 option.
              
    Notes:
    r
    A maximum of 1 ACD Unit can be installed per cabinet.  A maximum of 2 ACD Units can be 
    installed per phone system.
    Related Programming:
    Free Slot Assignment (pg. 0-5)     01 (1-6) (01-12) Hold (1-99) Hold
    Card Type Verification (pg. 8-23)     FF8 0 04 1 BSS 00 Hold [01-99 displays]
            
    Notes:
    ACD Unit Number
    (all CPCs) - Version 1.0 or higher
    Assign a number to each Built-In ACD unit installed.
    FF7   1   (B11)   00   Hold   (0-2)   Hold
     
    0=[no assignment]   (default)
    1=Built-In ACD #1 BSS: ACD Card Position --
    B=Cabinet no. 1-6
    SS=Slot no. 112=Built-In ACD #2
    $
    
     	7-,	 / 
    ACD Port Extension Numbers
    (all CPCs) - Version 1.0 or higher
    Assign the extension number that can be dialed to reach Built-In ACD.
    FF7   1   (B11)   01   (01-24)   00   Hold   (Ext.No.)   Hold
     
     
    Extension No. (1 to 4 digits)
    default:  [no assignment](max. 24 channels ACD Port No.
    can be assigned) BSS: ACD Card Position --
    B=Cabinet no. 1-6
    SS=Slot no. 11
    $
     	/ &-,  
    						
    							FF7: Applications Section 400-Programming
    Page 7-10
         l     DBS 576 (USA) issued 05/20/98 576-13-400
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appl ications
    FF8Maintenance Introduction
    Appe ndix  A
    Appe ndix  B
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appli cations
    FF8Maintenance Introduction
    Appe ndix A
    Appe ndix B
    Related Programming:
            
    Notes:
    Related Programming:
    MCO-Inbound Trunk Group Members (pg. 5-20)     FF5 3 (01-99) (001-576) Hold (1-576) Hold
             
    Notes:
    Related Programming:
    FF6 0: TRS/ARS Common (pg. 6-5)
    FF6 1: TRS Class Definitions (pg. 6-15)
    ACD Port Tenant Group Assignment
    (all CPCs) - Version 1.0 or higher
    Assign each ACD port to a Tenant Group, for incoming call functions.
    FF7   1   (B11)   01   (01-24)   01   Hold   (1-72)   Hold
     
     
    r
    Tenant Group No. 1-72
    default:  1
    (max. 24 channels ACD Port No.
    can be assigned) BSS: ACD Card Position --
    B=Cabinet no. 1-6
    SS=Slot no. 11
    
    $
     	/ % 1!-6
    ACD Port TRS Class Assignment (Day/Night)
    (all CPCs) - Version 1.0 or higher
    Assign a TRS Class to each ACD port, for incoming call functions.
    FF7   1   (B11)   01   (01-24)   02   (0 and 1)   Hold   (1-50)   Hold 
     
    TRS Class No. 1-50
    1=Night mode 0=Day 1&2 mode
    default:  1 (max. 24 channels ACD Port No.
    can be assigned) BSS: ACD Card Position --
    B=Cabinet no. 1-6
    SS=Slot no. 11
    $
    
     	 0 % 5 
    						
    							Section 400-Programming FF7: Applications
    576-13-400 DBS 576 (USA) issued 05/20/98
         l     Page 7-11
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appl ications
    FF8Maintenance Introduction
    Appe ndix  A
    Appe ndix  B
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appli cations
    FF8Maintenance Introduction
    Appe ndix A
    Appe ndix B
            
    Notes:
    Related Programming:
    FF1 8: Digital Pad Settings (pg. 1-176)
              
    ACD Port Digital Pad Class Assignment
    (all CPCs) - Version 1.0 or higher
    Assign a Digital Pad Class to each Built-In ACD port.
    FF7   1   (B11)   01   (01-24)   03   Hold   (1-8)   Hold 
     
    Digital Pad Class No. 1-8
    default:  6 (max. 24 channels ACD Port No.
    can be assigned) BSS: ACD Card Position --
    B=Cabinet no. 1-6
    SS=Slot no. 11
    
    $
     	/$/,
    Built-In ACD:  Service Range Assignment
    (all CPCs) - Version 1.0 or higher
    Assign up to 4 ranges of extensions that will have Built-In ACD service.
    FF7   1   (B11)   02   01   (0001-0016)   Hold   (0-6 or 0-12)   Hold 
     
          
    0001=Range #1 First ShelfShelf No. 1-6 or Slot No. 1-12
    default:  0/00  [no assignment] 0002=Range #1 First Slot
    0003=Range #1 Last Shelf
    0004=Range #1 Last Slot
    0005=Range #2 First Shelf
    0006=Range #2 First Slot
    0007=Range #2 Last Shelf
    0008=Range #2 Last Slot
    0009=Range #3 First Shelf
    0010=Range #3 First Slot
    0011=Range #3 Last Shelf
    0012=Range #3 Last Slot
    0013=Range #4 First Shelf
    0014=Range #4 First Slot
    0015=Range #4 Last Shelf
    0016=Range #4 Last Slot BSS: ACD Card Position --
    B=Cabinet no. 1-6
    SS=Slot no. 11
    
    $
    
    
     	
    $%) / 	/7 
    						
    							FF7: Applications Section 400-Programming
    Page 7-12
         l     DBS 576 (USA) issued 05/20/98 576-13-400
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appl ications
    FF8Maintenance Introduction
    Appe ndix  A
    Appe ndix  B
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appli cations
    FF8Maintenance Introduction
    Appe ndix A
    Appe ndix B
    Notes:
    The defined range cannot include any type of card other than DEC or AEC Extension Cards.  For 
    example, if there’s a Trunk Card installed between Extension Cards, you must define two separate 
    Extension Card ranges in the above address.
    Related Programming:
    Free Slot Assignment (pg. 0-5)     01 (1-6) (01-12) Hold (1-99) Hold
    Card Type Verification (pg. 8-23)     FF8 0 04 1 BSS 00 Hold [01-99 displays]
               
    Notes:
    See Section 520: ACD Reference Manual for the addresses contained within this portion of 
    programming.
    Related Programming:
    Built-In ACD:  Detail Setting
    (all CPCs) - Version 1.0 or higher
    This is the gateway for entering more detail settings for Built-In ACD.
    FF7   1   (B11)   03   Hold   CONF...
     
     
    BSS: ACD Card Position --
    B=Cabinet no. 1-6
    SS=Slot no. 11
    $
     	/ ,  
    						
    							Section 400-Programming FF7: Applications
    576-13-400 DBS 576 (USA) issued 05/20/98
         l     Page 7-13
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appl ications
    FF8Maintenance Introduction
    Appe ndix  A
    Appe ndix  B
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appli cations
    FF8Maintenance Introduction
    Appe ndix A
    Appe ndix B
    FF7  2:   API
    NOTE:  “API” means “Application Processor Interface.”  The API card 
    provides an interface path between the phone system’s information BUS 
    and an external, PC-based application such as 3rd-party (integrated) Voice 
    Mail, Enhanced ACD, etc.  An RS232C port (19,200bps maximum) located 
    on the API card provides the external interface connection.
    See “General Notes” in System Configuration (pg. 0-2) for more 
    information about using API with 3rd-party Voice Mail.
              
    Notes:
    One API card is available for each cabinet.  An AEC or DEC card should be installed in the slot to the 
    right of the API card, to provide up to 8 voice ports.
    Related Programming:
    Free Slot Assignment (pg. 0-5)     01 (1-6) (01-12) Hold (1-99) Hold
    Card Type Verification (pg. 8-23)     FF8 0 04 1 BSS 00 Hold [01-99 displays]
    API Unit Number
    (all CPCs) - Version 1.0 or higher
    Assign a number to each API unit installed.
    FF7   2   (BSS)   00   Hold   (0-6)   Hold
     
     
    0=[no assignment]   (default)
    1=API #1
    2=API #2
    ...
    6=API #6 BSS: API Card Position
    B=Cabinet no. 1-6
    SS=Slot No. where API port
           is located (01-11)
      $
    
     	/$ )-8 
    						
    							FF7: Applications Section 400-Programming
    Page 7-14
         l     DBS 576 (USA) issued 05/20/98 576-13-400
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appl ications
    FF8Maintenance Introduction
    Appe ndix  A
    Appe ndix  B
    FF1System
    FF2Tr u n k s
    FF3Extensions
    FF4FF-/Soft Keys
    FF5Groups
    FF6TRS/ARS
    0   System
    Configuration
    FF7Appli cations
    FF8Maintenance Introduction
    Appe ndix A
    Appe ndix B
              
    Notes:
    The API Port Number should be the phantom extension number.  It cannot be the existing extension 
    number.
    For example, when you select Card Type 80 (2 API ports) in Free Slot Assignment, you can only enter 
    API Port No.1 or No. 2 in this address.
    Related Programming:
    Free Slot Assignment (pg. 0-5)    01 (1-6) (01-12) Hold (1-99) Hold
              
    Notes:
    Tenant Groups can be used for controlling MCO access and SSD block assignment.
    Related Programming:
    FF1 3: MCO Access in Tenant Groups (pg. 1-163)
    FF1 0 15, 16, and 17: SSD Blocks (pg. 1-99)
    API Port Extension Numbers
    (all CPCs) - Version 1.0 or higher
    Assign the extension number that can be dialed to reach the API port.
    FF7   2   (BSS)   01   (01-08)   00   Hold   (Ext.No.)   Hold
     
     
     
    Extension No. (1 to 4 digits)
    default:  [no assignment]
    (max. 8 channels) API Port No.
    BSS: API Card Position
    B=Cabinet no. 1-6
    SS=Slot No. where API port
           is located (01-11)
      $
     	/$ &-, 
    API Port Tenant Group Assignment
    (all CPCs) - Version 1.0 or higher
    Assign each API port to a Tenant Group, for the outgoing function.
    FF7   2   (BSS)   01   (01-08)   01   Hold   (1-72)   Hold
     
     
     
    Tenant Group No. 1-72
    default:  1
    (max. 8 channels) API Port No. BSS: API Card Position