Home
>
Panasonic
>
Communications System
>
Panasonic Digital Business System 576 Technical Manual Section 400 Programming
Panasonic Digital Business System 576 Technical Manual Section 400 Programming
Have a look at the manual Panasonic Digital Business System 576 Technical Manual Section 400 Programming online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Section 400-Programming FF1: System Programming 576-13-400 DBS 576 (USA) issued 05/20/98 l Page 1-129 FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appl ications FF8Maintenance Introduction Appe ndix A Appe ndix B FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appli cations FF8Maintenance Introduction Appe ndix A Appe ndix B Notes: This timer applies to unanswered incoming calls on a DIL trunk that has a Delayed Ring position set (in FF2). If no Delayed Ring position is set for the trunk, this Timer will not apply, and the call will continue to ring the extension indefinitely. Related Programming: Day1 Delayed Ring Type/Destination ... for analog CO trunks (pg. 2-31) FF2 0 BSSC 04 0 Hold (0-4) Hold (0-9999) Hold for ISDN trunks (pg. 2-78) FF2 1 BSSC 05 0 Hold (0-4) Hold (0-9999) Hold for T1 CO trunks (pg. 2-110) FF2 2 BSSCC 05 0 Hold (0-4) Hold (0-9999) Hold Notes: This timer applies to unanswered incoming calls on a DIL trunk that has a Delayed Ring position set (in FF2). If no Delayed Ring position is set for the trunk, this Timer will not apply, and the call will continue to ring the extension indefinitely. CO Delayed Ring Timer (Day1) (all CPCs) - Version 1.0 or higher Set how long the system will ring an extension receiving an incoming call during Day1 mode, before moving the call to the Delayed Ring position. FF1 1 02 0003 Hold (0-255) Hold 0 = 5 seconds (default - all CPCs, Version 1.3 and higher) 1 = 1 second 2 = 2 seconds ... 255 = 255 seconds (1-255 = no. of seconds): , CO Delayed Ring Timer (Day2) (all CPCs) - Version 1.0 or higher Set how long the system will ring an extension receiving an incoming call during Day2 mode, before moving to the Delayed Ring position. FF1 1 02 0004 Hold (0-255) Hold 0 = 5 seconds (default - all CPCs, Version 1.3 and higher) 1 = 1 second 2 = 2 seconds ... 255 = 255 seconds (1-255 = no. of seconds): ,
FF1: System Programming Section 400-Programming Page 1-130 l DBS 576 (USA) issued 05/20/98 576-13-400 FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appl ications FF8Maintenance Introduction Appe ndix A Appe ndix B FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appli cations FF8Maintenance Introduction Appe ndix A Appe ndix B Related Programming: Day2 Delayed Ring Type/Destination ... for analog CO trunks (pg. 2-32) FF2 0 BSSC 04 2 Hold (0-4) Hold (0-9999) Hold for ISDN trunks (pg. 2-79) FF2 1 BSSC 05 2 Hold (0-4) Hold (0-9999) Hold for T1 CO trunks (pg. 2-111) FF2 2 BSSCC 05 2 Hold (0-4) Hold (0-9999) Hold Notes: This timer applies to unanswered incoming calls on a DIL trunk that has a Delayed Ring position set (in FF2). If no Delayed Ring position is set for the trunk, this Timer will not apply, and the call will continue to ring the extension indefinitely. Related Programming: Night Delayed Ring Type/Destination ... for analog CO trunks (pg. 2-33) FF2 0 BSSC 04 4 Hold (0-4) Hold (0-9999) Hold for ISDN trunks (pg. 2-80) FF2 1 BSSC 05 4 Hold (0-4) Hold (0-9999) Hold for T1 CO trunks (pg. 2-112) FF2 2 BSSCC 05 4 Hold (0-4) Hold (0-9999) Hold CO Delayed Ring Timer (Night) (all CPCs) - Version 1.0 or higher Set how long the system will ring an extension receiving an incoming call during Night mode, before moving to the Delayed Ring position. FF1 1 02 0005 Hold (0-255) Hold 0 = 5 seconds (default - all CPCs, Version 1.3 and higher) 1 = 1 second 2 = 2 seconds ... 255 = 255 seconds (1-255 = no. of seconds): , )9
Section 400-Programming FF1: System Programming 576-13-400 DBS 576 (USA) issued 05/20/98 l Page 1-131 FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appl ications FF8Maintenance Introduction Appe ndix A Appe ndix B FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appli cations FF8Maintenance Introduction Appe ndix A Appe ndix B Notes: This CO Delayed Ring Timer (Busy) applies to all system modes: Day1, Day2, and Night. (all CPCs - Version 1.3 and higher) If the above address is set to 0=Continue to queue the call, the caller will hear ringback tone while the call is being queued on the busy extension. (all CPCs - Version 1.3 and higher) If the call is on a DIL trunk but no Delayed Ring position has been set, the call will be queued on the busy extension until it becomes idle, regardless of the above setting. Related Programming: Day1/Day2/Night Delayed Ring Type/Destination ... for analog CO trunks (pg. 2-31) FF2 0 BSSC 04 0 Hold (0-4) Hold (0-9999) Hold (0-4) Hold... for ISDN trunks (pg. 2-78) FF2 1 BSSC 05 0 Hold (0-4) Hold (0-9999) Hold (0-4) Hold... for T1-CO trunks (pg. 2-110) FF2 2 BSSCC 05 0 Hold (0-4) Hold (0-9999) Hold (0-4) Hold... CO Delayed Ring Timer (Busy) (all CPCs) - Version 1.0 or higher Set how long the system will queue an incoming call on a busy extension, before moving to the delayed-ring position. FF1 1 02 0006 Hold (0-255) Hold 0 = 5 seconds (all CPCs - below Version 1.3) 1 = 1 second 2 = 2 seconds ... 255 = 255 seconds default: 120 seconds (1-255 = no. of seconds): 5 7- % or: 0 = Continue to queue the call on the busy idle. (all CPCs - Version 1.3 and higher) extension indefinitely, until it becomes
FF1: System Programming Section 400-Programming Page 1-132 l DBS 576 (USA) issued 05/20/98 576-13-400 FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appl ications FF8Maintenance Introduction Appe ndix A Appe ndix B FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appli cations FF8Maintenance Introduction Appe ndix A Appe ndix B Notes: Alarm Ringing: Ringing frequency/interval changes for an incoming call that rings unanswered for longer than the Slide Ring/Alarm Ring Timer. Slide Ringing: A type of delayed ringing for extensions with trunk line appearances. An incoming call on a trunk enabled for Slide Ringing (see FF2) will ring at the assigned extension or hunt group first (see Day1/2/Night Ring Assignments in FF2). Then, after the Slide Ring/Alarm Ring Timer expires, the call will begin ringing at the extension(s) with line appearances (see FF-Key Feature Assignment in FF4). Related Programming: Ring Alarm Frequency (pg. 1-106) FF1 0 21 0001 Hold (0-6) Hold Ring Alarm Pattern (pg. 1-107) FF1 0 21 0002 Hold (0-12) Hold Alarm Ringing (pg. 2-24) on analog CO trunks FF2 0 BSSC 02 13 Hold (0 or 1) Hold Slide Ringing (pg. 2-25) on analog CO trunks FF2 0 BSSC 02 14 Hold (0 or 1) Hold Alarm Ringing (pg. 2-68) on ISDN trunks FF2 1 BSSC 03 06 Hold (0 or 1) Hold Slide Ringing (pg. 2-69) on ISDN trunks FF2 1 BSSC 03 07 Hold (0 or 1) Hold Alarm Ringing (pg. 2-102) on T1-CO trunks FF2 2 BSSCC 03 11 Hold (0 or 1) Hold Slide Ringing (pg. 2-103) on T1-CO trunks FF2 2 BSSCC 03 12 Hold (0 or 1) Hold Slide Ring/Alarm Ring Timer (Day1) (all CPCs) - Version 1.0 or higher Set how long an incoming call will ring unanswered before moving to the Slide Ring position(s) or to the Alarm Ring frequency/pattern during Day1 mode. FF1 1 02 0007 Hold (0-255) Hold 1 = 1 second 2 = 2 seconds ... 255 = 255 seconds default: 20 seconds 0 = 5 seconds (1-255 = no. of seconds): % ,
Section 400-Programming FF1: System Programming 576-13-400 DBS 576 (USA) issued 05/20/98 l Page 1-133 FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appl ications FF8Maintenance Introduction Appe ndix A Appe ndix B FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appli cations FF8Maintenance Introduction Appe ndix A Appe ndix B Notes: Related Programming: Ring Alarm Frequency (pg. 1-106) FF1 0 21 0001 Hold (0-6) Hold Ring Alarm Pattern (pg. 1-107) FF1 0 21 0002 Hold (0-12) Hold Alarm Ringing (pg. 2-24) on analog CO trunks FF2 0 BSSC 02 13 Hold (0 or 1) Hold Slide Ringing (pg. 2-25) on analog CO trunks FF2 0 BSSC 02 14 Hold (0 or 1) Hold Alarm Ringing (pg. 2-68) on ISDN trunks FF2 1 BSSC 03 06 Hold (0 or 1) Hold Slide Ringing (pg. 2-69) on ISDN trunks FF2 1 BSSC 03 07 Hold (0 or 1) Hold Alarm Ringing (pg. 2-102) on T1-CO trunks FF2 2 BSSCC 03 11 Hold (0 or 1) Hold Slide Ringing (pg. 2-103) on T1-CO trunks FF2 2 BSSCC 03 12 Hold (0 or 1) Hold Slide Ring/Alarm Ring Timer (Day2) (all CPCs) - Version 1.0 or higher Set how long an unanswered incoming call will ring before moving to the Slide Ring position(s) or to the Alarm Ring frequency/pattern during Day2 mode. FF1 1 02 0008 Hold (0-255) Hold 1 = 1 second 2 = 2 seconds default: 20 seconds0 = 5 seconds ... 255 = 255 seconds (1-255 = no. of seconds): , Slide Ring/Alarm Ring Timer (Night) (all CPCs) - Version 1.0 or higher Set how long an unanswered incoming call will ring before moving to the Slide Ring position(s) or to the Alarm Ring frequency/pattern during Night mode. FF1 1 02 0009 Hold (0-255) Hold 1 = 1 second 2 = 2 seconds ... 255 = 255 seconds default: 20 seconds 0 = 5 seconds (1-255 = no. of seconds): & , )9
FF1: System Programming Section 400-Programming Page 1-134 l DBS 576 (USA) issued 05/20/98 576-13-400 FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appl ications FF8Maintenance Introduction Appe ndix A Appe ndix B FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appli cations FF8Maintenance Introduction Appe ndix A Appe ndix B Notes: Related Programming: Ring Alarm Frequency (pg. 1-106) FF1 0 21 0001 Hold (0-6) Hold Ring Alarm Pattern (pg. 1-107) FF1 0 21 0002 Hold (0-12) Hold Alarm Ringing (pg. 2-24) on analog CO trunks FF2 0 BSSC 02 13 Hold (0 or 1) Hold Slide Ringing (pg. 2-25) on analog CO trunks FF2 0 BSSC 02 14 Hold (0 or 1) Hold Alarm Ringing (pg. 2-68) on ISDN trunks FF2 1 BSSC 03 06 Hold (0 or 1) Hold Slide Ringing (pg. 2-69) on ISDN trunks FF2 1 BSSC 03 07 Hold (0 or 1) Hold Alarm Ringing (pg. 2-102) on T1 CO trunks FF2 2 BSSCC 03 11 Hold (0 or 1) Hold Slide Ringing (pg. 2-103) on T1 CO trunks FF2 2 BSSCC 03 12 Hold (0 or 1) Hold Notes: Related Programming: Extension COS: Long Talk Alarm (pg. 1-66) FF1 0 03 (00-15) 40 Hold (0 or 1) Hold Long Talk Alarm #2 Timer (pg. 1-135) FF1 1 02 0011 Hold (0-255) Hold Long Talk Alarm (pg. 2-23) on analog CO trunks FF2 0 BSSC 02 12 Hold (0 or 1) Hold Long Talk Alarm (pg. 2-68) on ISDN trunks FF2 1 BSSC 03 05 Hold (0 or 1) Hold Long Talk Alarm (pg. 2-102) on T1 CO trunks FF2 2 BSSCC 03 10 Hold (0 or 1) Hold Long Talk Alarm #1 Timer (all CPCs) - Version 1.0 or higher Set how long an outgoing call can last before the first Long Talk Alarm tone is sent to the extension. FF1 1 02 0010 Hold (0-255) Hold 0 = 5 seconds 1 = 1 second 2 = 2 seconds ... 255 = 255 seconds default: 180 seconds (1-255 = no. of seconds): 5! %,4 /52
Section 400-Programming FF1: System Programming 576-13-400 DBS 576 (USA) issued 05/20/98 l Page 1-135 FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appl ications FF8Maintenance Introduction Appe ndix A Appe ndix B FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appli cations FF8Maintenance Introduction Appe ndix A Appe ndix B Notes: Related Programming: Extension COS: Long Talk Alarm (pg. 1-66) FF1 0 03 (00-15) 40 Hold (0 or 1) Hold Long Talk Alarm #1 Timer (pg. 1-134) FF1 1 02 0010 Hold (0-255) Hold Long Talk Alarm (pg. 2-23) on analog CO trunks FF2 0 BSSC 02 12 Hold (0 or 1) Hold Long Talk Alarm (pg. 2-68) on ISDN trunks FF2 1 BSSC 03 05 Hold (0 or 1) Hold Long Talk Alarm (pg. 2-102) on T1 CO trunks FF2 2 BSSCC 03 10 Hold (0 or 1) Hold Notes: Long Talk Alarm #2 Timer (all CPCs) - Version 1.0 or higher Set the interval between subsequent Long Talk Alarm tones (after the first tone is sent to the extension during the outbound call -- see previous address). FF1 1 02 0011 Hold (0-255) Hold 0 = 5 seconds 1 = 1 second 2 = 2 seconds ... 255 = 255 seconds default: 60 seconds (1-255 = no. of seconds): 5! %,4 /52 Paging Timer (Tie-Lines) (all CPCs) - Version 1.0 or higher Set the amount of time the system will allow a tie-line caller to use paging. FF1 1 02 0012 Hold (0-255) Hold 0 = 5 seconds 1 = 1 second 2 = 2 seconds ... 255 = 255 seconds default: 30 seconds (1-255 = no. of seconds): $ % %*
FF1: System Programming Section 400-Programming Page 1-136 l DBS 576 (USA) issued 05/20/98 576-13-400 FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appl ications FF8Maintenance Introduction Appe ndix A Appe ndix B FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appli cations FF8Maintenance Introduction Appe ndix A Appe ndix B Related Programming: Trunk COS: Paging on DISA/Tie-Line Call (pg. 1-78) FF1 0 04 (00-15) 05 Hold (0 or 1) Hold Paging Group Members (pg. 5-22) FF5 4 (01-10) (02-73) Hold (0-9999) Hold Notes: Related Programming: Extension COS: Onhook Trunk-to-Trunk Transfer (pg. 1-70) FF1 0 03 (00-15) 45 Hold (0 or 1) Hold Trunk-to-Trunk Connection Timer (all CPCs) - Version 1.0 or higher Set the amount of time the system will monitor a trunk-to-trunk connection before disconnecting. FF1 1 02 0013 Hold (0-255) Hold 0 = no check (allow indefinitely) 1 = 1 minute 2 = 2 minutes ... 255 = 255 minutes default: 60 minutes (1 hour) (1-255 = no. of minutes): %3 ! %3 % Queuing Timer (ARS) (all CPCs) - Version 1.0 or higher Set the amount of time the system will queue an outbound call through Automatic Route Selection (ARS) for a trunk line to become available. FF1 1 02 0014 Hold (0-255) Hold 0 = 5 seconds 1 = 1 second 2 = 2 seconds ... 255 = 255 seconds default: 15 seconds (1-255 = no. of seconds): / D--
Section 400-Programming FF1: System Programming 576-13-400 DBS 576 (USA) issued 05/20/98 l Page 1-137 FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appl ications FF8Maintenance Introduction Appe ndix A Appe ndix B FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appli cations FF8Maintenance Introduction Appe ndix A Appe ndix B Notes: If this Queuing Timer expires before a trunk becomes available, the call will either move to the next queuing level or the caller will receive busy tone, depending on ARS settings. Related Programming: ARS/LCR Setting (pg. 1-27) FF1 0 02 0010 Hold (0 or 1) Hold Trunk Queuing for Originator (Route List) (pg. 6-20) FF6 1 01 (01-50) 0003 Hold (0 or 1) Hold Notes: (all CPCs - Version 1.3 and higher) If the DID trunk does not have a Delayed Ring position set, the call will continue to ring the extension indefinitely, or follow its Call-Forward settings (if any). Related Programming: DID/DNIS Dial Table (“A” Side) (pg. 1-169) FF1 4 02 (000-575) (1-6) Hold (0-9999 or 1-72) Hold DID/DNIS Dial Table (“B” Side) (pg. 1-171) FF1 4 04 (000-575) (1-6) Hold (0-9999 or 1-72) Hold DID Delayed Ring Timer (all CPCs) - Version 1.0 or higher Set the amount of time a DID (Direct Inward Dial) call will ring before moving to the delayed-ring position. FF1 1 02 0015 Hold (0-255) Hold 0 = No delayed ring 1 = 1 second 2 = 2 seconds ... 255 = 255 seconds (1-255 = no. of seconds): , & default: 20 seconds
FF1: System Programming Section 400-Programming Page 1-138 l DBS 576 (USA) issued 05/20/98 576-13-400 FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appl ications FF8Maintenance Introduction Appe ndix A Appe ndix B FF1System FF2Tr u n k s FF3Extensions FF4FF-/Soft Keys FF5Groups FF6TRS/ARS 0 System Configuration FF7Appli cations FF8Maintenance Introduction Appe ndix A Appe ndix B FF1 1 03: Extension Timer 1 Notes: Related Programming: Call Forward/DND Confirmation Tone Timer (all CPCs) - Version 1.0 or higher Set the duration of the Call Forwarding tone or Do-Not-Disturb confirmation tone sent to an extension when the user goes off-hook or presses ON/OFF while Call Forwarding or DND is activated. FF1 1 03 0001 Hold (0-255) Hold 0 = no tone issued 1 = 1 second 2 = 2 seconds 3 = 3 seconds (default) ... 255 = 255 seconds A0) %! Message-Waiting Tone Timer (all CPCs) - Version 1.0 or higher Set the duration of the Message-Waiting confirmation tone sent to an extension when the user goes off-hook or presses ON/OFF while the extension is in receipt of a message-waiting. FF1 1 03 0002 Hold (0-255) Hold 0 = no tone issued 1 = 1 second 2 = 2 seconds 3 = 3 seconds (default) ... 255 = 255 seconds 21A%!