NEAX2000 IVS2 CCIS System ManualPage 58 ND-70918 (E), Issue 1.0 CHAPTER 2 INSTALLATION Required Equipment Ta b l e 2 - 2 shows the equipment and cables required when providing No. 7 CCIS with analog interface. Table 2-2 Required Equipment and Cable for No. 7 CCIS with Analog Interface EQUIPMENT/ CABLEDESCRIPTION QUANTITY REMARKS PN-2LDT or PN-2ODTLoop Dial Trunk or 2-wire E&M/4-wire E&M Trunk1-128 PN-SC00 Common Channel Handler Card 1-8 PN-AP00-B Application Processor Card for Centralized Billing1 PZ-M537 Expansion Memory Card 1 MODEM For Common Signaling Channel N N: Number of PN- SC00 cards (Should be provided with customer.) RS NORM- 4 CA-A/RS NORM-4S CA-AConnecting cables between PN- SC00 and MODEMN N: Number of PN- SC00 cards Length: 4 m (13.1 ft.) LINE Cable Connecting cable between MODEMsN N: Number of PN- SC00 cards (Should be provided with customer.)
CHAPTER 2 INSTALLATION Installation Procedure NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 59 INSTALLATION PROCEDURE No. 7 CCIS with Digital Interface Install the equipment according to the procedures shown in Figure 2-3. For installation of the PBX, refer to the Installation Procedure Manual. Figure 2-3 Installation Procedure for No. 7 CCIS with Digital Interface START MOUNTING CCH CARD MOUNTING EXPMEM CARD SELECTION OF PLO IN MOUNTING DTI CARD MOUNTING AP00 CARD MOUNTING CONN CARD Page 61 Page 60 Page 62 Page 63 Page 66 Page 64 END MP CARD CABLE CONNECTION CABLE CONNECTION Page 67 Page 70 VIA MDF VIA CONN CARD OPTICAL CABLE CONNECTIONThis procedure is required when expanding the capacity of call This procedure is required when providing Centralized Billing. NOTE information store memory. This procedure is required when providing PZ-M542/PZ-M557 card to connect a coaxial cable for 30-DTI card. This procedure is required when providing PZ-M542/PZ-M557 card to connect a coaxial cable for 30-DTI card. MOUNTING M10 CARD Page 65 This procedure is required when providing PN-M10 card to connect a optical interface. Page 72 This procedure is required when providing PN-M10 card to connect a optical interface. NOTE:This procedure is not required when using Built-in SMDR of MP card in Local Office.
NEAX2000 IVS2 CCIS System ManualPage 60 ND-70918 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure Mounting DTI Card (1) Before mounting the DTI (PN-24DTA-C/PN-30DTC-A) card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4 on Page 259. (2) Mount the DTI card in the following AP slot in PIM0 through PIM7. PIM0: AP00-AP10 PIM1-7: AP00-AP11 NOTE:The DTI card (DTI0, DTI1) which sends a clock signal to PLO of the MP card must be mounted in the AP slots on PIM0. (3) After mounting the card, set the MB switch to DOWN position to put the card in service. AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 2 INSTALLATION Installation Procedure NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 61 Mounting CCH Card (1) Before mounting the CCH (PN-SC00) card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4 on Page 259. (2) Mount the CCH card in the following AP slot of PIM0 through PIM7. PIM0: AP00-AP10 PIM1-7: AP00-AP11 (3) After mounting the card, set the MB switch to DOWN position to put the card in service. AT T E N T I O NContents Static Sensitive Handling Precautions Required
NEAX2000 IVS2 CCIS System ManualPage 62 ND-70918 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure Mounting EXPMEM Card When billing information of more than 1600 calls is needed, install the EXPMEM (PZ-M537) card as detailed below. (1) Confirm the correct switch setting. See CHAPTER 4 on Page 259. (2) Mount the EXPMEM card on the AP00 card. (3) Mount the AP00 card into AP slots. (See Mounting AP00 Card on Page 63.) AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 2 INSTALLATION Installation Procedure NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 63 Mounting AP00 Card (1) Before mounting the AP00 (PN-AP00-B) card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4 on Page 259. (2) Mount the AP00 card in any one of AP slot on each PIM. (3) After mounting the card, set the MB switch to the DOWN position to put the card in service. AT T E N T I O NContents Static Sensitive Handling Precautions Required
NEAX2000 IVS2 CCIS System ManualPage 64 ND-70918 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure Mounting CONN Card When providing the CONN (PZ-M542/M557) card to connect a coaxial cable for 30-DTI card, do the following installation. (1) Confirm the correct switch settings. See CHAPTER 4 on Page 259. (2) Mount the CONN card on LTC connector of each PIM. For details, refer to the Installation Procedure Manual. AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 2 INSTALLATION Installation Procedure NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 65 Mounting M10 Card (1) Confirm the correct switch settings. See CHAPTER 4 on Page 259. (2) Mount the M10 card in any one of LT slot on each PIM. AT T E N T I O NContents Static Sensitive Handling Precautions Required
NEAX2000 IVS2 CCIS System ManualPage 66 ND-70918 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure Selection of PLO in MP Card (1) Confirm the correct switch settings. See CHAPTER 4 on Page 259. (2) Mount the MP (PN-CP14) card in the MP slot of PIM0. AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 2 INSTALLATION Installation Procedure NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 67 Cable Connection via MDF When using a twisted-pair cable, connect the cable to a CSU via the MDF as shown in Figure 2-4. Figure 2-4 DTI Cable Connection via MDF CSU MDF LTC0/LTC1/LTC2/LTC3 CONNECTORTWISTED-PAIR CABLE BWBPBX (SHIELD TYPE) MAX. 200 m (655 ft.) .......... 24-DTI MAX. 400 m (1310 ft.)......... 30-DTI 24-DTI 30-DTI