    							 NEAX2000 IVS2 CCIS System ManualPage 18  ND-70918 (E), Issue 1.0
    CHAPTER 1  GENERAL INFORMATION
    Time Slot Assignment Condition
    Time Slot Allocation for DTI Card
    On each DTI card, the system recognizes the lowest and highest channel numbers to which trunk
    numbers are assigned, and allocates time slots to all the channels between them. If trunk
    numbers are assigned to nonconsecutive channels, the system also allocates time slots to
    channels not assigned.
    For example, as shown in Figure 1-7, when Channel 1 through Channel 10 have been assigned
    by system data programming (CM07 YY=01) except Channel 5, the system allocates a total of
    10 time slots for all ten channels. Therefore, to avoid allocation of unnecessary time slots, it is
    recommended that consecutive channels be assigned on each DTI card.
    Figure 1-7  Time Slot Allocation for DTI
    DXXX
    DXXX
    DXXX NONE
    DXXX
    NONEDXXX
    1
    CH010
    9
    6
    4 5HIGHEST CHANNEL
    10 TIME SLOTS ARE 
    ALLOCATED EVEN 
    WHEN CH5 IS NOT 
    ASSIGNED.
    LOWEST CHANNEL 
    						
    							CHAPTER 1  GENERAL INFORMATION
    Time Slot Assignment Condition
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 19
    Number of Time Slots Required for DTI/CCH Card
    (1) When the system is serving as a Lower Hierarchy Office within the network, 1 time slot is 
    allocated for setting up a fixed path between the DTI/ODT and the CCH as the common 
    signaling channel.
    (2) When the system is serving as a High Hierarchy Office within the network, 1 time slot is 
    allocated to the distant Main Office and distant Local Office for the common signaling 
    channel.
    NOTE 1:A billing information from distant Local Office is transferred as follows.
    AP00→MP→CCH
    NOTE 2:When a common signaling data link is provided via a MODEM, the time slot for the
    common signaling channel is not required. 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 20  ND-70918 (E), Issue 1.0
    CHAPTER 1  GENERAL INFORMATION
    Time Slot Assignment Condition
    Figure 1-8 shows the CCH time slot assignment for CCIS with Digital Interface.
    Figure 1-8  CCH Time Slot Assignment (for No. 7 CCIS with Digital Interface)
    A
    B
    CM
    TDSW
    DTI
    CCH
    AP00
    MP
    TDSW
    DTI
    CCH
    AP00
    DTI
    CCH
    DTI
    CCH
    DTI
    CCH
    MPM: Main Office
    D : Local Office (High Hierarchy Office)
    A, B, C: Local Office (Low Hierarchy Office)
    To Local Office D
    (1 time slot)
    To Main Office M
    (1 time slot)
    To Local Office A
    (1 time slot)
    To Local Office B
    (1 time slot)
    To Local Office C
    (1 time slot)   
    Network Configuration:
      When the System locates at A, B, or C (Low Hierarchy Office) in the above network:
      When the System locates at D (High Hierarchy Office) in the above network:
     
    D 
    						
    							CHAPTER 1  GENERAL INFORMATION
    Time Slot Assignment Condition
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 21
    Figure 1-9 shows the CCH time slot assignment for No. 7 CCIS with Analog Interface.
    Figure 1-9  CCH Time Slot Assignment (for No. 7 CCIS with Analog Interface)
    TDSW
    TDSWM: Main Office
    D : Local Office (High Hierarchy Office)
    A, B, C: Local Office (Low Hierarchy Office)
      Network Configuration:
    
      When the System locates at A, B, or C (Low Hierarchy Office) in the above network:
    
      When the System locates at D (High Hierarchy Office) in the above network:
    LDT/ODT
    LDT/ODT
    CCH MODEM
    To Local  
    Office D
    (1 time slot)
    LDT/ODT
    LDT/ODT
    CCH MODEM
    To  M a i n   
    Office M
    (1 time slot)
    LDT/ODT
    LDT/ODT
    To Local  
    Office  
    A, B or C
    CCH MODEM
    (1 time slot)
    TDSW
    LDT/ODT
    LDT/ODT
    To Local  
    Office D
    (1 time slot)
    TDSW
    LDT/ODT
    LDT/ODT
    To  M a i n   
    Office M
    (1 time slot)
    LDT/ODT
    LDT/ODT
    To Local  
    Office  
    A, B or C
    (1 time slot)
    CCH MODEM
    LDT/ODT
    LDT/ODT
    CCH MODEM
    LDT/ODT
    MODEMCCH
    A
    B
    CM
    D 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 22  ND-70918 (E), Issue 1.0
    CHAPTER 1  GENERAL INFORMATION
    Time Slot Assignment Condition
    Table 1-4 shows the number of time slots for each of the cards required for No. 7 CCIS with Digital
    Interface and Ta b l e  1 - 5 shows the number of time slots for each of the cards required for No. 7
    CCIS with Analog Interface.
    Table 1-4  Number of Time Slots Required per DTI/CCH/AP00 Card 
    (for No. 7 CCIS with Digital Interface)
    CARDNUMBER OF TIME 
    SLOTS PER CARDREMARKS
    PN-24DTA-C
    1-24  Number of CCIS channels (the number of 
    CCH) + number of trunks assigned
    PN-30DTC-A1-31
    PN-SC001  For a distant Main Office
    –  Common Signaling Channel: 1 time slot
    1  For a distant Local Office
    –  Common Signaling Channel: 1 time slot
    PN-AP00-B0 
    						
    							CHAPTER 1  GENERAL INFORMATION
    Time Slot Assignment Condition
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 23
    Table 1-5  Number of Time Slots Required per CCH/AP00 Card
    (for No. 7 CCIS with Analog Interface)
    CARDNUMBER OF TIME 
    SLOTS PER CARDREMARKS
    PN-SC00
    1  For a distant Main Office
    –  Common Signaling Channel: 1 time slot
    1  For a distant Local Office
    –  Common Signaling Channel: 1 time slot
    PN-AP00-B0 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 24  ND-70918 (E), Issue 1.0
    CHAPTER 1  GENERAL INFORMATION
    DTI Specifications
    DTI SPECIFICATIONS
    Transmission Characteristics
    Table 1-6  Transmission Characteristics
    CHARACTERISTICS 24-CHANNEL 30-CHANNEL
    (1) Output
     Line Rate 1.544 Mbps ±50 ppm 2.048 Mbps ±50 ppm
     Line Code  AMI with ZCS/B8ZS* HDB3 (High Density Bipolar 3)
     Line Impedance 100 ohms 75 ohms + 100 µH
    (Coaxial Cable)
    120 ohms + 160 µH
    (Twisted-Pair Cable)
     Pulse Amplitude 
    (Base to Peak)3 volts ±0.6 volts 2.37 volts nominal
    (Coaxial Cable)
    3 volts nominal
    (Twisted-Pair Cable)
     Pulse Width 324 ns ±30 ns 244 ns nominal
    (2) Input
     Line Rate 1.544 Mbps ±200 bps (130 ppm) 2.048 Mbps ±50 ppm
     Pulse Amplitude
    (Base to Peak)1.5 volts – 3 volts 1.5 volts – 2.7 volts
    (Coaxial Cable)
    1.5 volts – 3.3 volts
    (Twisted-Pair Cable)
    Frame 
    Synchronization 
    Pa tte r n100011011100
     Input Jitter ITU-T Fig. 1/G743 ITU-T Fig. 1/G743
     Wander +138UI, –193UI or 
    –138UI, +193UIITU-T G823
     Cable Length from 
    PBX to MDF or 
    External EquipmentMax. 200 m (MAX 656.2 ft.)
    [with 0.65 
    φ (22 ABAM) twisted-
    pair cable]Max. 400 m (MAX 1312.4 ft.)
    [with 0.65 φ (22 ABAM) 
    twisted-pair cable]
    * AMI: Alternate Mark Inversion
    ZCS: Zero Code Suppression
    B8ZS: Bipolar Eight Zero Substitution 
    						
    							CHAPTER 1  GENERAL INFORMATION
    DTI Specifications
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 25
    Frame Configuration of 24-DTI
    According to the AT&T Specifications for 24-channel transmission, there are two types of frame
    configurations: 12-Multi Frame (D4) and 24-Multi Frame (ESF).
    (1) 12-Multi Frame (D4)
    The frame has 12-Multi Frames, and each Multi frame has a 24-channel PCM signal (8 bits/
    channel) and an S bit (Super Frame Bit). Figure 1-10 shows the frame configuration, and 
    Ta b l e  1 - 7 shows frame bit assignment.
    Figure 1-10  Frame Configuration of 24-DTI (12-Multi Frame)
    SCH1 CH2 CH3 CH24
    12 345 67812 34567812 345 678 12345 678
    FRAME 1 FRAME 2 FRAME 3 FRAME 12
    125 sm
    S: SUPERFRAME BIT  
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 26  ND-70918 (E), Issue 1.0
    CHAPTER 1  GENERAL INFORMATION
    DTI Specifications
    * The S-bit is the first bit in each frame.
    * Frames are repeated in the order shown above.
    * Frames 6 and 12 become signal frames.
    Table 1-7  12-Multi Frame Bit Assignment
    FRAME
    No.S BITBIT No. OF EACH 
    CHANNEL
    (CH1-CH12)
    SIGNAL
    CHANNEL
    TERMINAL
    SYNCHRONIZATION
    (FT)SIGNAL
    SYNCHRONIZATION
    (FS)INFORMATION
    SIGNAL BITCONTROL
    SIGNAL BIT
    11 1-8
    201-8
    30 1-8
    401-8
    51 1-8
    611-78A
    70 1-8
    811-8
    91 1-8
    10 1 1-8
    11 0 1-8
    12 0 1-7 8 B 
    						
    							CHAPTER 1  GENERAL INFORMATION
    DTI Specifications
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 27
    (2) 24-Multi Frame (Extended Super Frame )
    This frame has 24-Multi Frames and each Multi frame has a 24-Channel PCM signal (8 bits/
    channel) and an S bit (Super Frame Bit). Figure 1-11 shows the frame configuration, and 
    Ta b l e  1 - 8 shows frame bit assignment.
    Figure 1-11  Frame Configuration of 24-DTI (24-Multi Frame)
    TS0 TS1 TS2 TS15 TS16 TS17 TS30 TS31
    FRAME 0 FRAME 1 FRAME 2 FRAME 3 FRAME 14 FRAME 15