NEAX2000 IVS2 CCIS System ManualPage 258 ND-70918 (E), Issue 1.0 This page is for your notes.
NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 259 CHAPTER 4 CIRCUIT CARD INFORMATION This chapter explains the mounting location, the meaning of lamp indications, and the method of switch settings of each circuit card for the No. 7 CCIS system.
NEAX2000 IVS2 CCIS System ManualPage 260 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION How to Read This Chapter HOW TO READ THIS CHAPTER This chapter explains each circuit card used in this system about the following items. Explanations are given in alphabetical order of the circuit card names within each circuit card category (Control, Application Processor, and Line/Trunk). (1) Locations of Lamps, Switches, and Connectors The locations of lamps, switches, and connectors of each circuit card are shown by a face layout. (2) Lamp Indications The name, color, and functions of each indicator lamp equipped on each circuit card are described in a table. (3) Switch Settings The name, settings, and functions of each switch equipped on each circuit card are described in a table. Each switch setting table has a “CHECK” column. Make necessary entries in the CHECK column during and/or after the system installation and maintenance, and use each table as a reference for subsequent system maintenance and operations.
CHAPTER 4 CIRCUIT CARD INFORMATION Mounting Location of Circuit Card NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 261 MOUNTING LOCATION OF CIRCUIT CARD This section explains the location for mounting circuit cards for the CCIS system. Circuit Card Mounting Slots Figure 4-1 shows circuit card mounting slots allocated in the PIM. Figure 4-1 Mounting Location *1PN-CP14 (MP) card on PIM0. PN-CP15 (FP) card on the FP11 slot on PIM0, and FP12 slot on PIM 2, 4, 6. PZ-M537 (EXPMEM) card on the PN-CP14 (MP) card on PIM0. *2PN-SC00 (CCH) card on the AP00-AP10 slots on PIM0, on the AP00-AP11 slots on PIM 1-7. PN-M10 (M10), PN-2LDTA (LDT), PN-ODTA (ODT) and PN-2ODTB (ODT) card on the LT00- LT10 slots on PIM0, on the LT00-LT11 slots on PIM 1-7. *3PN-AP00-B (AP00), PN-24DTA (DTI), PN-30DTC-A (DTI) card on the AP00-AP07 slots on PIM 0-7. *4PZ-M542/PZ-M557 (CONN) card into the LTC0-LTC3 connector. LT09/AP09LT08/AP08LT07/AP07 LT C 1LT C 0LT C 2 BWB PIM 0 ~ 7 FRONTAC/DC PWR LT10/AP10LT00/AP00LT01/AP01LT02/AP02LT03/AP03LT04/AP04LT05/AP05LT06/AP06LT11/AP11/FP11MP12/FP12 LT C 3 DC/DC PWR PFTVM *3*2 *1 *4
NEAX2000 IVS2 CCIS System ManualPage 262 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION List of Required Cards LIST OF REQUIRED CARDS Table 4-1 shows the required cards to be explained in this section. *MB = Make Busy Table 4-1 List of Required Cards NAME (FUNCTIONAL NAME)LAMP X: PROVIDED –: NOT PROVIDEDSWITCH X: PROVIDED –: NOT PROVIDEDEXTRACTION/ INSERTION WITH POWER ON X:ALLOWED :ALLOWED AFTER MB* –: NOT ALLOWEDREFERENCE PAGE PN-CP14 (MP) X X–Page 263 PN-CP15 (FP) X XPage 268 PN-AP00-B (AP00)XXPage 270 PN-24DTA-C (DTI) X XPage 276 PN-30DTC-A (DTI) X XPage 282 PN-SC00 (CCH) X XPage 288 PZ-M537 (EXPMEM)–X–Page 291 PZ-M542 (CONN)–XXPage 294 PZ-M557 (CONN)–XXPage 296 PN-2LDTA (LDT) X–XPage 298 PN-M10 (M10) X X–Page 299 PN-2ODTA (ODT) X–XPage 301 PN-2ODTB (ODT) X–XPage 302
CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP14 (MP) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 263 PN-CP14 (MP) Locations of Lamps, Switches, and Connectors CONN: To CONNR connector on PZ-M537 (EXPMEM) Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. CLK Green Remains lit while receiving clock signals to the PLO. SW3 RUN SW1 SW2 CLK VR DK JACK CONNSW4 JP0JP1 RS1 RS0
NEAX2000 IVS2 CCIS System ManualPage 264 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP14 (MP) Switch Settings NOTE 1:Set the groove on the switch to the desired position. NOTE 2:Only when executing “MP Program Download” in MATWorX Studio, set the SW3 to 5- 8. CAUTION When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its mounting slot. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW3 (Rotary SW) NOTE 1 0-FOn Line (Call processing is in progress) 2Off Line (Call processing is stopped) I/O port: As per CM40 YY=08 3Off Line (Call processing is stopped) I/O port: 9600bps (Fixed) 5 NOTE 2Off Line (Call processing is stopped) I/O port: 9600bps 6 NOTE 2Off Line (Call processing is stopped) I/O port: 19200bps 7 NOTE 2Off Line (Call processing is stopped) I/O port: 38400bps 8 NOTE 2Off Line (Call processing is stopped) I/O port: 57600bps B For clearing the office data CFor setting the resident system program 1, 4, 9 A, D-FNot used (Continued) 0 0
CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP14 (MP) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 265 SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW1 (Push SW)For initializing CPU SW2 (Piano Key SW)1ON A-law (Australia) OFF µ-law (North America) 2, 3Selection of PLO0 input (Phase Locked Oscillator) For clock receiver office: For clock source office: SW2-2 SW2-3 OFF OFF 4ONWhen using RS1 port for built-in MODEM OFF When using RS1 port for RS-232C (Continued) 4 3 2 1 OFF ON SW2-2 SW2-3 FUNCTION OFF OFF 1.5MHz clock [For PN-24DTA-C/PN-24PRTA] ON OFF 192kHz clock [For PN-BRTA] OFF ON 2MHz clock [For PN-30DTC-A/PN-2BRTC] ON ON Not used
NEAX2000 IVS2 CCIS System ManualPage 266 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP14 (MP) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW4 (Dip SW) 1Not used 2 Not used 3, 4Selection of PLO1 input (Phase Locked Oscillator) For clock receiver office: For clock source office: SW4-3 SW4-4 OFF OFF VR (Rotary SW) Variable Resister for External Hold Tone Source (0 - 20 Kohms : Clockwise) DK (Connector) 02 Ground detection 01 Ground sending (Continued) 1 23 4ON OFF OFF SW4-3 SW4-4 FUNCTION OFF OFF 1.5MHz clock [For PN-24DTA-C/PN-24PRTA] ON OFF 192kHz clock [For PN-BRTA] OFF ON 2MHz clock [For PN-30DTC-A/PN-2BRTC] ON ON Not used 20 0 01 02
CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP14 (MP) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 267 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK JP0 (Jumper pin) UPNot used (Memory backup OFF) For normal operation (Memory backup ON) JP1 (Jumper pin) For using internal tone source DOWN For using external tone source Fr o n tDOWN Fr o n t UP