NEAX2000 IVS2 CCIS System ManualPage 268 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP15 (FP) PN-CP15 (FP) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while the circuit card is operating normally. SENSE RUN MB SW1
CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP15 (FP) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 269 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/ unplugging the circuit card. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 10-3For setting FP No. 0 For mounting this card in PIM0 1 For mounting this card in PIM2 2 For mounting this card in PIM4 3 For mounting this card in PIM6 4-F Not used MB (Toggle SW) NOTE 2 UPFor make-busy For normal operation SW1 (Piano Key SW)1 - 3Not used 4For normal operation OFFNot used 0 1 2 3 ON DOWN 4 3 2 1 OFF ON OFF ON
NEAX2000 IVS2 CCIS System ManualPage 270 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-AP00-B (AP00) PN-AP00-B (AP00) Locations of Lamps, Switches, and Connectors CONN: To CONNR connector on PZ-M537 (EXPMEM) RS3 RS2 RS1 RS0 SENSE RUN MB SW0 SW2 L3 L2 L1 L0 SW1 CONN JP0 JP1
CHAPTER 4 CIRCUIT CARD INFORMATION PN-AP00-B (AP00) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 271 Lamp Indications Switch Settings LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. L0-L3 Green Second data setting value for CMD001 > 250 0 1 (Por t 0)-3 (Por t 2) L3 Indication of transmitting status of Port 0Indication of CTS signal status on Po r t 0 - 2 L2 Indication of transmitting status of Port 1Indication of DCD signal status on Po r t 0 - 2 L1 Indication of transmitting status of Port 2Indication of TXD signal status on Po r t 0 - 2 L0 Indication of transmitting status of Port 3Indication of RXD signal status on Po r t 0 - 2 SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 10-3 Not used 4-F Set the switch to match the AP Number (04-31) to be set by CM05. MB (Toggle SW) NOTE 2 UP For make-busy For normal operation (Continued) F 4 AP No. SW1-4: ON 04 05 06 07 08 09 10 11 12 13 14 15 SW1-4: OFF 20 21 22 23 24 25 26 27 28 29 30 31 SW No. 456789ABCDEF ON DOWN
NEAX2000 IVS2 CCIS System ManualPage 272 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-AP00-B (AP00) SW0 (Dip SW) 1-3 ONNot used For normal operation 4, 5 For normal operation OFFNot used 6 NOTE 3ONSets No. 0 Port forcibly in a state which DSR signal is always provided. OFFReceives DSR signal from the DCE on No. 0 Port. 7 NOTE 3ONSets No. 1 Port forcibly in a state which DSR signal is always provided. OFFReceives DSR signal from the DCE on No. 1 Port. 8 NOTE 3ONSets No. 2 Port forcibly in a state which DSR signal is always provided. OFFReceives DSR signal from the DCE on No. 2 Port. SW1 (Piano Key SW) 1For normal operation OFFNot used 2For normal operation OFFFor AP data clearing by CMD100/ CMD101 3For normal operation OFFFor AP data clearing by CMD100/ CMD101 4 ONAP No. 4-15 OFFAP No. 20-31 (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 1 23 45 67 8ON OFF ON 4 3 2 1 OFF ON ON ON ON
CHAPTER 4 CIRCUIT CARD INFORMATION PN-AP00-B (AP00) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 273 SW2 (Dip SW) 1 NOTE 3ONSets No. 3 Port forcibly in a state which DSR signal is always provided. OFFReceives DSR signal from the DCE on No. 3 Port. 2ONEnables the receive clock from the DCE (Modem) when No. 1 Port is synchronous. (Clock is received at the RXC terminal) OFFUses internal clock as the receive clock when No. 1 Port is synchronous. When No. 1 Port is asynchronous. 3ONEnables transmit clock from the DCE (Modem) when No. 1 Port is synchronous. (Clock is received at the TXC (2) terminal.) OFFUses internal clock as the send clock when No. 1 Port is synchronous. When No. 1 Port is asynchronous. 4ONTransmit the send clock from the DTE (this card) when No. 1 Port is synchronous. (Clock is transmitted from the TXC (1) terminal) OFFNot transmit the send clock from the DTE (this card) when No. 1 Port is synchronous. When No. 1 Port is asynchronous. 5ON When No. 1 Port is asynchronous. OFF When No. 1 Port is synchronous. (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 1 23 45 67 8ON
NEAX2000 IVS2 CCIS System ManualPage 274 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-AP00-B (AP00) The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/ unplugging the circuit card. NOTE 3:When the DCE connected to the port does not provide a function to send the DSR signals, set the switch to ON. In this case, the AP00 card can not recognize the actual state of the DCE, so that the call records or system messages will not be stored in the memory buffer on the AP00 card even if the cable is disconnected from the DCE. When the switch is set to OFF, the call records or system messages will be stored when the cable is disconnected, and will be sent when the cable is re-connected. SW2 (Dip SW) 6 NOTE 4ONUses internal clock as the receive clock when No. 1 Port is synchronous. When No. 1 Port is asynchronous. OFFEnables receive clock from the DCE (Modem) when No. 1 Port is synchronous. (Clock is received at the RXC terminal) 7Not used 8Not used JP0 (Jumper SW) For normal operation (Memory backup ON) DOWNNot used (Memory backup OFF) JP1 (Jumper SW) UP Not used For normal operation (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 1 23 45 67 8ON OFF OFF UP DOWN
CHAPTER 4 CIRCUIT CARD INFORMATION PN-AP00-B (AP00) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 275 NOTE 4:The use of the external clock (from the distant end) or the internal clock is determined by the following table: CLOCKSW2 26 External ON OFF Internal OFF ON
NEAX2000 IVS2 CCIS System ManualPage 276 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) PN-24DTA-C (DTI) Locations of Lamps, Switches and Connectors SENSE RUN MB CRC PCM FRM RMT AIS BL SW1 SW0 JRR1 AISS MAS JPR0 JPS
CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 277 Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. CRC Red Remains lit when detecting Cyclic Redundancy Checking (CRC) errors. PCM Red Remains lit when detecting PCM signal loss. FRM Red Remains lit when detecting Frame Alignment signal loss. RMT Red Remains lit when receiving Frame Alignment signal loss alarm from a distant office. AIS Red Remains lit when a pattern of consecutive “1” is received. The distant office transmits this signal for a loop-back test. BL Red B channel status ON : More than 10 channels are busy OFF : All channels are idle Flash (60 IPM) : Only one channel is busy Flash (120 IPM) : 2 through 10 channels are busy