NEC Neax 2000 Ivs2 Ccis System Manual
Have a look at the manual NEC Neax 2000 Ivs2 Ccis System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
NEAX2000 IVS2 CCIS System ManualPage 208 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING House Phone-CCIS Operating Procedure To call an Attendant in another office: (1) House Phone-CCIS user lifts the handset. (2) The Attendant in another office is automatically called. ATND lamps on Attendant Console flash and console buzzer sounds.
CHAPTER 3 SYSTEM DATA PROGRAMMING Incoming Call Identification-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 209 INCOMING CALL IDENTIFICATION-CCIS General Description This feature allows an attendant to visually identify the type of service and/or trunk group which is arriving or waiting to be answered at the Attendant Console through the CCIS network. Programming DESCRIPTION DATA Specify the ICI key to which an incoming call from each trunk route terminates. (1) (2)YY=15 00-63: Trunk Route No. 75: No. 7 CCIS Call Assign the ATT Call Selection keys required on the ATTCON. The following ATT Call Selection keys are initially set. Key No. Data Description 16 F6061 Recall (RCL) 17 F6060 Operator Call (ATND) 18 F6000 C.O. Incoming 0 (LND0) (1) (2)YY=00 ATTCON No. (E000-E007) + + Key No. F60XX XX : 00-07: C.O. Incoming Call 0-7 40-47 : Tie Line Incoming Call 0-7 50-53 : Special Operator Call 0-3 54: Priority Call 0 55: Priority Call 1 56: Emergency Call 60: Operator Call 61: Recall 62: Serial Call 63: Call Forwarding Don’t Answer (-No Answer) 64: Call Forwarding Busy Line 65: Call Forwarding-Intercept 66: Off Hook Alarm 67: Interposition Calling/ Transfer Assign the required Attendant Call Selection keys and ATTCON Function keys to each DESKCON, according to the Key label. (1) (2)YY=00 ATTCON No. (E000-E007) + + Key No. F6000-F6067: Type of Calls to be assigned F6100-F6245: Functions to be assigned CM90 START CM35 A 07 IO O P 108 IO O P 209 IO O P 310 IO O P 411 IO O P 512 IO O P 6 010203040506 1314 1516 1718 ANS 979091 9293 9495 RLS 96 123 456 789 *0#SRC DEST HOLD CANCEL , ,
NEAX2000 IVS2 CCIS System ManualPage 210 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Incoming Call Identification-CCIS Operating Procedure No manual operation is required. DESCRIPTION DATA Key No. Data Description (Key Label) Default Data 13 F6000 C.O. Incoming 0 (LDN) NONE 14 F6040 Tie Line Incoming 0 (TIE) NONE 15 F6064 Call Forwarding-Busy Line (Busy) NONE 16 F6060 Operator Call (ATND) F6061 (Recall) 17 F6063 Call Forwarding-No Answer (NANS) F6060 (Operator Call) 18 F6061 Recall (Recall) F6000 (C.O. Incoming 0) 90 F6200 Source (SRC) F6200 (Source) 91 F6201 Destination (DEST) F6201 (Destination) 93 F6203 Talk (Talk) NONE 94 F6204 Hold (Hold) F6204 (Hold) 95 F6202 Cancel (Cancel) F6202 (Cancel) 96 Answer (Answer) 97 Release (Release) NOTE:When the DESKCON is used to set H/M features, the Reset key should be assigned to one of the feature keys (i.e key 21) in the Idle state mode. A END L6 (12) L5 (11) L4 (10) L3 (09) L2 (08) L1 (07) 0 896 3 5 2 1 4 7 # SRC (90)DEST (91) (93) (95) Answer (96) Hold (94)Release (97) Cancel Talk Position Busy VolumeNight(1 5) (01) (02) (03) (04)(13)(16 )(17 )(18 )(1 9) (2 0) (2 1)(14) (2 4) (22) (23)LDN TIE Busy ATND NANS Recall EMG BV TRKSL Call Park SC SVCREC Mute PAGE Start
CHAPTER 3 SYSTEM DATA PROGRAMMING LDN Night Connection-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 211 LDN NIGHT CONNECTION-CCIS General Description This feature routes Listed Directory Number (LDN) calls to a predesignated station in the CCIS network when the Night Mode has been entered. Programming DESCRIPTION DATA Provide the system with Diversion Display. (1) (2)204 0: To provide Specify the Incoming Call Identification (ICI) key to which each LDN call from each trunk route will terminate. (1) (2)YY=15 00-63: Trunk Route No. 00-07: C.O. Incoming Call 0-7 Assign the required number of LDN keys as ICI keys. (1) (2)YY=00 E00X + + 13-18 (Key No.) X: Attendant Console No. F6000-F6007: LDN0-7 Assign the indialed number to each LDN key assigned by CM90. The indialed number should be different from any numbers assigned by CM10 and CM11. (1) (2)YY=01 For DID 0 : Effective data in CM35 Y=15 1-8 : LDN Key No. 00-07 assigned by CM46. X-XXXX: Indialed No. CM35 CM90 CM50 START END CM08 ,
NEAX2000 IVS2 CCIS System ManualPage 212 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING LDN Night Connection-CCIS To provide the LDN Diversion feature, the following programming is also required. DESCRIPTION DATA Provide the system with the LDN Diversion feature.(1) (2)205 0: To provide Assign the data for LDN Diversion to each indialed number assigned by CM50 YY=01. (1) (2)YY=00 Tenant No. of the LDN 00 : Effective data in CM35 YY=15 01-08 : LDN key No. 00-07 assigned by CM90. 00-63 : Tenant No. Note that a call is diverted to LDN 0-7 keys as specified by CM58 YY=02-07, even if CM50 YY=01, 1-8 has already been set. (1) (2)YY=01 TAS Group No. Same as CM58 Y=00 00-63: TAS Group No. (1) (2)YY=02 Day Mode destination of the LDN Same as CM58 Y=00 00-07 : LDN key 0-7 08 : To TAS 09 : To station/outside party assigned by CM58 YY=08. (1) (2)YY=03 Night Mode destination Same as CM58 Y=00 00-07 : LDN key 0-7 08 : To TAS 09 : To station/outside party assigned by CM58 YY=09. (1) (2)YY=04 Day Mode Diversion for busy destination station Same as CM58 Y=00 00: To ATTCON (BUSY key) 08: To TAS 09: Camped on CM58 START CM08 A
CHAPTER 3 SYSTEM DATA PROGRAMMING LDN Night Connection-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 213 DESCRIPTION DATA (1) (2)YY=05 Night Mode Diversion for busy destination station Same as CM58 YY=00 Same as CM58 YY=04 (1) (2)YY=06 Day Mode Diversion for non-an- swering destination station Same as CM58 YY=00 00: To ATTCON (NANS key) 08: To TAS (1) (2)YY=07 Night Mode Diversion for non- answering destination station Same as CM58 YY=00 Same as CM58 YY=06 If the 2nd data (09) is designated by CM58 YY=02, 03, assign the station/outside par- ty number to be diverted. (1) (2)YY=08 Day Mode destination station/ outside party Same as CM58 Y=00 X-XXXXXXXX: Station No. CXX: Abbreviated Code for Outside Par ty XX : 00-31 (Abbreviated Code) (1) (2)YY=09 Night Mode destination station/ outside party Same as CM58 Y=00 X-XXXXXXXX: Station No. CXX: Abbreviated Code for Outside Par ty XX : 00-31 (Abbreviated Code) CM58 A B
NEAX2000 IVS2 CCIS System ManualPage 214 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING LDN Night Connection-CCIS Operating Procedure No manual operation is required. DESCRIPTION DATA If the 2nd data (CXX) is designated by CM58 YY=08, 09, specify the combination of trunk routes allowing the Tandem connection. (1) (2)Y=0 XX ZZ XX: 00-63 (Incoming Trunk Route) ZZ : 00-63 (Outgoing Trunk Route for CCIS) 0: Allow If the 2nd data (CXX) is designated by CM58 YY=08, 09 assign the Speed Calling-System (System Speed Dialing) memory area exclusively for LDN-Outside.(1) (2)66: Exclusively for LDN-Outside XXX ZZZ XXX: 000-299 (First Memory/SLot No. in Block) ZZZ : 001-300 (No. of Slots to be allocated in Block) Set the stored number to the Memory Slot number allocated by CM71. (1) (2)Y=0 000-299: Memory Slot No. XXXX YY...Y XX : Access Code (Max. 2 digits) : Separator Mark YY...Y : Calling Par ty’s No. (Max. 26 digits) CM71 CM72 END CM36 B , ,
CHAPTER 3 SYSTEM DATA PROGRAMMING Link Alarm Display-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 215 LINK ALARM DISPLAY-CCIS General Description This feature provides an indication on external equipment when the CCIS link is connected/ disconnected, when the system is initialized or when the CCH is in make busy. Programming Hardware Required DK card × 1/External Equipment Interface on the MP card External Indicator (Bell, Lamp etc.) provided by the customer For the cross connection of External Indicator, refer to Installation Procedure Manual. Operating Procedure No manual operation is required. DESCRIPTION DATA Assign the DK card to the required LEN. NOTE:The DK card number must be assigned to the 1st LEN (Level 0), the 3rd LEN (Level 2) of each LT s l o t .(1) (2)000-763: LEN E800-E831: DK Card No. For PIM0/PIM1: E800-E807 For PIM2/PIM3: E808-E815 For PIM4/PIM5: E816-E823 For PIM6/PIM7: E824-E831 NOTE:Circuit No. 3 of E831 is used for built-in External Equipment Interface of MP card by setting CM44. Assign the function of CCIS Link Alarm Indication to the DK.(1) (2)XX Y XX : 00-31 (Card No. assigned by CM10>E800-E831) Y : 0-3 (Circuit No.) 313 : Built-in External Equipment Interface on MP card 35 XX XX: 01-07 (CCIS CH No.) CM44 START END CM10
NEAX2000 IVS2 CCIS System ManualPage 216 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Message Waiting Lamp Setting-Attendant-CCIS MESSAGE WAITING LAMP SETTING-ATTENDANT-CCIS General Description This feature allows an attendant, in the IMX system, to set or cancel a Message Waiting lamp indication, through the CCIS network on a station in a PBX system. Programming Hardware Required To provide a Single-Line Telephone with Message Waiting lamp: LC (PN-4LCD/4LCF) card Operating Procedure To set a Message Waiting indication from the IMX ATTCON: (1) Press an idle LOOP key; receive dial tone. (2) Dial the Message Waiting feature access code (max. three digits); receive feature dial tone. (3) Dial the station number; receive service set tone. (4) Message Waiting indication is set. (5) Press the RELEASE key to return to an idle condition. To cancel a Message Waiting indication: (1) Press an idle LOOP key; receive dial tone. (2) Dial the Message Waiting cancel code (max. 3 digits); receive feature dial tone. (3) Dial the station number; receive service set tone. (4) Message Waiting indication is canceled. (5) Press the CANCL key to return to an idle condition. DESCRIPTION DATA Provide each station with Message Wait- ing service. (1) (2)YY=03 X-XXXXXXXX: Station No. 0: To provideSTART END CM13
CHAPTER 3 SYSTEM DATA PROGRAMMING Message Waiting Lamp Setting-Station-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 217 MESSAGE WAITING LAMP SETTING-STATION-CCIS General Description This feature allows a station user in the IMX system to set or cancel a Message Waiting lamp indication, through the CCIS network, to a station in the PBX system with this feature. Programming Hardware Required To provide a Single-Line Telephone with Message Waiting lamp: LC (PN-4LCD/4LCF) card Operating Procedure To set a Message Waiting indication: (1) Lift the handset; receive dial tone. (2) Dial the Message Waiting feature access code (up to 3 digits); receive feature dial tone. (3) Dial the desired station number; receive service set tone. (4) Message Waiting indication is set at the station. To cancel a Message Waiting indication: (1) Lift the handset; receive dial tone. (2) Dial the Message Waiting cancellation code (up to 3 digits); receive feature dial tone. (3) Dial the desired station number; receive service set tone. (4) Message Waiting indication at station is canceled. DESCRIPTION DATA Provide each station with Message Wait- ing service. (1) (2)Y=03 X-XXXXXXXX: Station No. 0: To provideSTART END CM13