    							 NEAX2000 IVS2 CCIS System ManualPage 238  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk Answer From Any Station-CCIS
    TRUNK ANSWER FROM ANY STATION-CCIS
    General Description
    This feature allows any station, not restricted from incoming calls, to answer incoming calls when
    the network is in Night Mode.
    When this feature is activated, incoming exchange network calls will activate a common aler t
    Trunk Answer From Any Station (TAS) signal at the customer premises. By dialing a specified
    code, any station in the local PBX may answer the call and extend it to any other station in the
    CCIS network using Call Transfer-All Calls-CCIS.
    Programming
    SATELLITE OFFICE
    TA S
    NO. 7CCISMAIN OFFICE
    COT/DIDCO
    PBX PBX/IMX
    The Main Office sends dial code as LDN number 
    to the Satellite Office 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk Answer From Any Station-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 239
    For the Satellite Office
    Use the LDN Diversion feature.
    DESCRIPTION DATA
    Assign a Trunk Restriction Class to each 
    station.
    (1)
    (2)YY=01
    X-XXXXXXXX: Station No.
    XZ
    Z: 1-8: Trunk Restriction Class in Night 
    Mode
    1: Unrestricted (RCA)
    2: Non-Restricted 1 (RCB)
    3: Non-Restricted 2 (RCC)
    4: Semi-Restricted 1 (RCD)
    5: Semi-Restricted 2 (RCE)
    6: Restricted 1 (RCF)
    7: Restricted 2 (RCG)
    8: Fully-Restricted (RCH)
    Assign the Service Restriction Class B to 
    the required stations.
    (1)
    (2)YY=02
    X-XXXXXXXX: Station No.
    XX ZZ
    ZZ: 00-15 : Service Restriction 
    Class B
    Allow Trunk Answer From Any Station in 
    the Service Restriction Class B assigned 
    by CM12 YY=02.
    (1)
    (2)YY=53
    00-15: Service Restriction Class B 
    assigned by CM12 YY=02
    1 : Allow
    Provide the system with the Diversion 
    Display and the LDN Diversion features.(1)
    (2)204: Diversion Display
    0: To provide
    (1)
    (2)205: LDN Diversion
    0: To provide
    Assign the indialed number to each TIE 
    key on the ATTCON. But, the ATTCON 
    should not be equipped in the Satellite 
    Office. The indialed number should be 
    different from any numbers assigned by 
    CM10 and CM11.
    (1)
    (2)YY=02
    1-8: TIE key No.
    X-XXXX: Indialed No.START
    CM12
    A
    CM15
    CM08
    CM50 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 240  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk Answer From Any Station-CCIS
    DESCRIPTION DATA
    Assign the data for LDN Diversion to each 
    indialed number assigned by CM50 
    YY=02.
    (1)
    (2)YY=00 Tenant No. of the LDN
    01-08: TIE 0-7 assigned by CM50 
    YY=02
    00-63: Tenant No.
    
    (1)
    (2)YY=01 TAS Group No.
    Same as CM58 Y=00
    00-63: TAS Group No.
    
    (1)
    (2)YY=02 Day Mode Destination
    Same as CM58 Y=00
    08: To TAS
    
    (1)
    (2)YY=03 Night Mode Destination
    Same as CM58 Y=00
    08: To TAS
    Specify the function of each type of TAS 
    within a system.
    (1)
    (2)
    (1)
    (2)Y=0-4 TAS Answer A-E
    1: Tie Line/Dial-in
    0 : Cannot be answered
    1 : Can be answered
    7: A call terminated to a different tenant
    0 : Can be answered
    1 : Cannot be answered
    Assign the access code for each type of 
    TAS (TAS Answer A-E) assigned by CM53.
    (1)
    (2)Y=0-3 Numbering Plan Group 0-3
    X-XXXX: Access Code
    A047: TAS Answer A
    A048: TAS Answer B
    A049: TAS Answer C
    A050: TAS Answer D
    A051: TAS Answer E
    CM58
    A
    CM53
    CM20
    B
    (1)
    Y17
    0TA S
    Answer A0/1 0/1
    1TA S
    Answer B0/1 0/1
    2TA S
    Answer C0/1 0/1
    3TA S
    Answer D0/1 0/1
    4TA S
    Answer E0/1 0/1 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk Answer From Any Station-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 241
    DESCRIPTION DATA
    Specify the tenants allowing TAS Answer 
    between them.
    (1)
    (2)Y=0
    XX ZZ
    XX: 00-63 (Tenant No. of TAS Answer 
    station)
    ZZ: 00-63 (Tenant No. of Trunk)
    0 : Allow
    1: RestrictedB
    END
    CM63 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 242  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk Answer From Any Station-CCIS
    To provide an External TAS Indicator via the DK card:
    DESCRIPTION DATA
    Assign the card number of the to required 
    LEN.
    NOTE:The DK card number must be as-
    signed to the 1st LEN (Level 0), 
    the 3rd LEN (Level 2) of each LT 
    slot.(1)
    (2)000-763: LEN
    E800-E831: DK Card No.
    For PIM0/1: EB800-EB807
    For PIM2/3: EB808-EB815
    For PIM4/5: EB816-EB823
    For PIM6/7: EB824-EB831
    Assign the TAS Group number assigned 
    by CM30 YY=17 to a circuit number on the 
    DK card.
    NOTE:Built-in External Equipment 
    Interface is not available for 
    External TAS indicator 
    connection.(1)
    (2)XX Y: Circuit No.
    XX : 00-31: DK Card No. assigned by 
    CM10 E800-E831
    Y : 0-3: Circuit No.
    313 : Built-in External Equipment 
    Interface on MP card
    13 XX
    XX: 00-63 (TAS Group No. assigned by 
    CM30 YY=17)
    Specify the indication pattern for the 
    External TAS Indicator.(1)
    (2)00
    01: 30 IPM
    02: 60 IPM
    03: 120 IPM
    07: Steady on
    NONE : 120 IPM (0.25 sec. ON/OFF)
    CM59 START
    CM10
    END
    CM44 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk Answer From Any Station-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 243
    To provide the telephone set for TAS Indication:
    DESCRIPTION DATA
    Assign the TAS Buzzer number (telephone 
    set for TAS Indication) to the required LEN. 
    The TAS Buzzer number must correspond 
    with the TAS Group number assigned by 
    CM30 YY=17.
    E600-E663 TAS Group 00-63(1)
    (2)000-763: LEN
    E600-E663: TAS Buzzer No.START
    CM10
    END 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 244  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk Answer From Any Station-CCIS
    For Main Office
    COT: When using a COT interface between the Central Office and a Main Office, set up 
    programming to the Main Office by using the DIT-CCIS feature, and send the dial 
    code as an LDN to the Satellite Office. Refer to programming of DIT-CCIS in this 
    chapter for details.
    DID:  When using a DID interface between the Central Office and the Main Office, there 
    are two programming patterns:
    Pattern 1
      When an incoming LDN call is diverted to a Satellite Office in both Day Mode and Night
    Mode, program by using the LCR and uniform numbering features. Refer to Numbering
    Plan Assignment.
    Pattern 2
      When an incoming LDN call is diverted to a Satellite Office in either Day Mode or Night
    Mode (not both), the following programming for the LDN Diversion-Outside feature is
    required.
    DESCRIPTION DATA
    Provide the system with the Diversion 
    Display and the LDN Diversion features.(1)
    (2)204: Diversion Display
    0: To provide
    (1)
    (2)205: LDN Diversion
    0: To provide
    Assign the indialed number to each TIE 
    key on the ATTCON. The indialed number 
    should be different from any numbers 
    assigned by CM10 and CM11.
    (1)
    (2)YY=01
    1-8: LDN key No.
    X-XXXX: Indialed No.
    Assign the data for LDN Diversion to each 
    indialed number assigned by CM50 
    YY=01.
    (1)
    (2)YY=00 Tenant No.
    01-08: LDN 0-7 assigned by CM50 
    YY=01
    00-63: TAS Group
    
    (1)
    (2)YY=02 Day Mode Destination
    01-08: LDN 0-7 assigned by CM50 
    YY=01
    09: LDN Diversion-Outside 
    (Assigned by CM58 YY=08)
    CM50
    CM58 START
    CM08
    A 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk Answer From Any Station-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 245
    DESCRIPTION DATA
    
    (1)
    (2)YY=03 Night Mode Destination
    Same as CM58 YY=02
    09: LDN Diversion-Outside 
    (Assigned by CM58 YY=09)
    Assign the Abbreviated Code for System 
    Speed Dialing to terminate the Satellite 
    Office via CCIS by DID in Day Mode and 
    Night Mode, respectively.
    
    (1)
    (2)YY=08 Day Mode
    YY=09 Night Mode
    Same as CM58 YY=02
    CXX
    XX: Abbreviated Code for System 
    Speed Dialing Assigned by 
    CM71>66
    Assign the System Speed Dialing memory 
    area exclusively for LDN Diversion-
    Outside.(1)
    (2)66: Exclusively for LDN Diversion-
    Outside
    XXX YYY
    XXX: 000-299 (First Memory/Slot No. 
    in Block)
    YYY: 001-300 (No. of Slots to be 
    allocated in Block)
    Set the stored number into the Memory 
    Slot number allocated by CM71.(1)
    (2)000-299: Memory Slot No.
    XX  YY...Y
    XX : Access Code (Max. 2 digits)
    : Separator Mark
    YY...Y : Calling Par ty’s No.
    (Max. 26 digits)
    Specify the combination of Trunk Routes 
    allowing a Tandem connection.
    (1)
    (2)Y=0
    XX ZZ
    XX: 00-63 (Incoming Trunk Route)
    ZZ : 00-63 (Outgoing Trunk Route for 
    CCIS)
    0: Allow
    END
    CM58
    A
    CM71
    CM72
    CM36,
    , 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 246  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk Answer From Any Station-CCIS
    Hardware Required
    To provide the External TAS Indicator:
    - DK card (Four Indicators per card can be equipped)
    - Indicator 
    Requirement to External Indicator
    Control Method : Loop/Ground/Battery (-27 V) (Max. 125 mA)
    Type : Visual and/or Audible type with volume control
    For cross connection of the TAS indicator, refer to the Installation Procedure Manual.
    To provide the telephone set for TAS Indication:
    - PN-4LC card (Two telephone sets per card can be equipped.)
    - Conventional telephone sets
    Operating Procedure
    To answer an incoming call in Night Mode:
    (1) The TAS signal (bell, buzzer, etc.) sounds indicating an incoming call.
    (2) Lift the handset; receive dial tone.
    (3) Dial the TAS access code.
    (4) Connect to the incoming call. 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk to Trunk Restriction-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 247
    TRUNK TO TRUNK RESTRICTION-CCIS
    General Description
    This feature allows trunk to trunk tandem restriction by caller’s information (e.g., caller is a trunk)
    through the CCIS network.
    Case 1: A tandem connection at the following office can be restricted by Trunk Restriction
    Class of Trunk A and Outgoing Connection Restriction data of  Trunk B.
    Case 2: When Station B transfers an incoming call through CCIS to Trunk C, a trunk-to-trunk
    connection can be restricted by Trunk Restriction Class of Trunk A and Outgoing
    Connection Restriction data of Trunk C.
    INCOMING
    TRUNK
    Trunk A
    Office
    BOffice
    AOUTGOING
    TRUNK
    Trunk B CCIS
    INCOMING
    TRUNK
    Trunk A
    Office
    BOffice
    A
    Station B CCIS
    Trunk C Transfer by
    CONSULTATION
    HOLD 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Ccis System Manual