    							 NEAX2000 IVS2 CCIS System ManualPage 278  ND-70918 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    NOTE 10-3 Not used
    4-F Set the switch to match the AP Number (04-31) to 
    be set by CM05.
    MB (Toggle SW)
    NOTE 2
    UP For make-busy
    For normal operation
    (Continued)
    F
    4
    AP No.SW1-4: ON04 05 06 07 08 09 10 11 12 13 14 15
    SW1-4: OFF20 21 22 23 24 25 26 27 28 29 30 31
    SW No.456789ABCDEF
    ON
    DOWN 
    						
    							CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 279
    SW0
    (Piano Key SW)
    1
    NOTE 3
    NOTE 4ONSource clock signal from network is 
    sent to the PLO 0 input on MP card.
    OFFSource clock signal from network is 
    not sent to the PLO 0 input on MP 
    card. 
    2 
    NOTE 3
    NOTE 4ONSource clock signal from network is 
    sent to the PLO 1 input on MP card.
    OFFSource clock signal from network is 
    not sent to the PLO 1 input on MP 
    card. 
    3ONRemote loop-back
    For normal operation
    4ONLocal loop-back (AIS send)
    For normal operation
    5Set equalizer according to the cable 
    length between the PBX and the 
    MDF. OFF
    6
    OFF
    7
    OFF
    8Not used
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    (Continued)
    OFF
    ON
    5 6 7 8
    1 2 3 4
    OFF
    OFF
    ON
    SW0-5 SW0-6 SW0-7 CABLE LENGTH
    ON ON ON 0-4 m (0-131.2 ft.)
    ON ON OFF 40-80 m (131.2-262.5 ft.)
    ON OFF ON 80-120 m (262.5-394 ft.)
    ON OFF OFF 120-160 m (394-525 ft.)
    OFF ON ON 160-200 m (525-656 ft.)
    OFF OFF OFF Signal is not sentON
    ON
    OFF 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 280  ND-70918 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and   , the setting of the switch varies with the system concerned.SW1
    (Piano Key SW)
    NOTE 41 Not used
    2 Not used
    3 Not used
    4ON AP No. 04-15
    OFF AP No. 20-31
    JPR0 (Jumper pin)
    UPNeutral grounding on the receiving 
    line is provided.
    Neutral grounding on the receiving 
    line is not provided.
    JPR1 (Jumper pin)
    Line impedance: 100 ohms
    Left Line impedance: 110 ohms
    JPS (Jumper pin)
    UPNeutral grounding on the 
    transmitting line is provided.
    Neutral grounding on the 
    transmitting line is not provided.
    MAS (Jumper pin)
    UP Clock Source
    Clock Receiver
    AISS (Jumper pin)
    AIS signal is sent out when make-
    busy or power on.
    DOWNAIS signal is not sent out when 
    make-busy or power on.
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    (Continued)
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    OFF
    OFF
    DOWN
    Right
    DOWN
    DOWN
    UP 
    						
    							CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-24DTA-C (DTI)
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 281
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/
    unplugging the circuit card.
    NOTE 3:Set SW0-1 and SW0-2 as follows:
    NOTE 4:When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the DTI cards
    mounted in PIM0 to “OFF”.
    NOTE 5:Mount the DTI card which receives a source clock signal into PIM0.
    CONDITIONSDTI0 DTI1 DTI2 DTI3 DTI4
    REMARKS
    SW 
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2
    When one DTI is 
    provided.ON OFF––––––––MP card will receive the clock 
    signal from DTI0 at its PLO0 
    input.
    When more than 
    one DTI is provided.ON OFF OFF ON OFF OFF OFF OFF OFF OFF MP card will receive the clock 
    signal from DTI0 at its PLO0 
    input, under normal 
    conditions.
    Should a clock failure occur 
    with DTI0, MP card will 
    automatically switch to the 
    PLO1 input which gets clock 
    from DTI1. 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 282  ND-70918 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    PN-30DTC-A (DTI)
    Locations of Lamps, Switches and Connectors
    SENS
    RUN
    MB
    SW
    PCM 
    FRM 
    MFRM 
    RMT 
    MRMT 
    AIS 
    BL  
     
     
     
     
    JP JPSJPR 
    						
    							CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 283
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM when this card is normally operating.
    PCM Red Remains lit when detecting PCM signal loss.
    FRM Red Remains lit when detecting Frame Alignment signal loss.
    MFRM Red Remains lit when detecting Multi-Frame Alignment signal loss on 
    time Slot 16.
    RMT Red Remains lit when receiving the alarm from a distant office 
    because Frame Alignment signal loss has been detected at the 
    distant office.
    MRMT Red Remains lit when receiving the alarm from a distant office 
    because Multi-Frame Alignment signal loss has been detected at 
    the distant office.
    AIS Red Remains lit when indicating that the pattern of consecutive “1” is 
    being received. The distant office transmits this signal for a loop-
    back test distant.
    BL Red B channel status
    ON  : More than10 channels are busy
    OFF : All channels are idle
    Flash (60 IPM) :  Only one channel is busy
    Flash (120 IPM) : 2 to 10 channels are busy 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 284  ND-70918 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    Switch Settings
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENS 
    (Rotary SW)
    NOTE 14-FSet the switch to match the AP Number (04-31) to 
    be set by CM05.
    0-3Not used
    MB (Toggle SW)
    NOTE 2
    UP
    For make-busy
    For normal operation
    (Continued)
    F
    4AP No.SW-8: ON04 05 06 07 08 09 10 11 12 13 14 15
    SW-8: OFF20 21 22 23 24 25 26 27 28 29 30 31
    SW No.456789ABCDEF
    ON
    DOWN 
    						
    							CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 285
    SW
    (Piano Key SW)
    1
    NOTE 3
    NOTE 4ONSource clock signal from network is 
    sent to the PLO 0 input on MP card.
    OFFSource clock signal from network is 
    not sent to the PLO 0 input on MP 
    card 
    2
    NOTE 3
    NOTE 4ONSource clock signal from network is 
    sent to the PLO 1 input on MP card.
    OFFSource clock signal from network is 
    not sent to the PLO 1 input on MP 
    card. 
    3ON Remote loop-back
    For normal operation
    4ON Local loop-back (AIS send)
    For normal operation
    5ONTransmission line cable: 
    Coaxial cable (75 ohms)
    Transmission line cable: 
    Twisted-pair cable (120 ohms)
    6
    Always set to OFF
    7
    8ON AP No. 04-15
    OFF AP No. 20-31
    (Continued)
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    OFF
    ON
    5 6 7 8
    1 2
    3 4
    OFF
    OFF
    OFF
    OFF
    OFF 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 286  ND-70918 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and  , the setting of the switch varies with the system concerned.
    NOTE 1:Set the groove on the switch to the desired position.
    NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/
    unplugging the circuit card. JPS
    (Jumper pin)
    Balanced transmission
    (For twisted-pair cable)
    DOWNTA is grounded on the transmission 
    line (For coaxial cable)
    JPR
    (Jumper pin)
    Balanced transmission
    (For twisted-pair cable)
    DOWNRA is grounded on the transmission 
    line (For coaxial cable)
    JP
    (Jumper pin)
    RIGHTLine impedance: 75 ohms
    (For coaxial cable)
    Line impedance: 120 ohms 
    (For twisted-pair cable)
    (Continued)
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    UP
    UP
    LEFT 
    						
    							CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-30DTC-A (DTI)
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 287
    NOTE 3:Set the SW-1 and SW-2 as follows:
    NOTE 4:When the PBX is a clock source office, set the SW-1 and SW-2 on all the DTI cards
    mounted in PIM0 to “OFF”.
    NOTE 5:Mount the DTI card which receives a source clock signal into PIM0.
    CONDITIONSDTI0 DTI1 DTI2 DTI3
    REMARKS
    SW
    -1SW
    -2SW
    -1SW
    -2SW
    -1SW
    -2SW
    -1SW
    -2
    When one DTI is 
    provided.ON OFF––––––MP card will receive the clock 
    signal from DTI0 at its PLO0 
    input.
    When more than one 
    DTI is 
    provided.ON OFF OFF ON OFF OFF OFF OFF MP card will receive the clock 
    signal from DTI0 at its PLO0 
    input, under normal conditions.
    Should a clock failure occur with 
    DTI0, MP card will automatically 
    switch to the PLO1 input which 
    gets from DTI1. 
    						