NEAX2000 IVS2 CCIS System ManualPage iv ND-70918 (E), Issue 1.0 TABLE OF CONTENTS Page CHAPTER 4 CIRCUIT CARD INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259 HOW TO READ THIS CHAPTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260 MOUNTING LOCATION OF CIRCUIT CARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 Circuit Card Mounting Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 LIST OF REQUIRED CARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 PN-CP14 (MP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263 PN-CP15 (FP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268 PN-AP00-B (AP00) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 PN-24DTA-C (DTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276 PN-30DTC-A (DTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 PN-SC00 (CCH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288 PZ-M537 (EXPMEM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 PZ-M542 (CONN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294 PZ-M557 (CONN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296 PN-2LDTA (LDT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298 PN-M10 (M10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299 PN-2ODTA (ODT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301 PN-2ODTB (ODT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302 CHAPTER 5 OPERATION TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303 LOOP-BACK TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 INTEROFFICE TRANSMISSION LINE TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310 PLO OPERATION TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313 Clock Signal Generation Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313 Clock Signal Synchronization Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314 Interoffice Synchronization Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 Source Office Mode Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
LIST OF FIGURES Figure TitlePage NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page v Figure 1-1 No. 7 CCIS System Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Figure 1-2 Clock Supply Route . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Figure 1-3 No. 7 CCIS with DTI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Figure 1-4 No. 7 CCIS with LDT/ODT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Figure 1-5 Centralized Billing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Figure 1-6 Accommodation of DTI/CCH into TDSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Figure 1-7 Time Slot Allocation for DTI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Figure 1-8 CCH Time Slot Assignment (for No. 7 CCIS with Digital Interface) . . . . . . . . . . . . . . . 20 Figure 1-9 CCH Time Slot Assignment (for No. 7 CCIS with Analog Interface) . . . . . . . . . . . . . . 21 Figure 1-10 Frame Configuration of 24-DTI (12-Multi Frame) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Figure 1-11 Frame Configuration of 24-DTI (24-Multi Frame) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Figure 1-12 Frame Configuration of 30-DTI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Figure 1-13 Network Structuring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Figure 1-14 Example of Station Number (Closed Numbering) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Figure 1-15 Example of Office Code and Station Number (Open Numbering) . . . . . . . . . . . . . . . . 42 Figure 2-1 Static Electricity Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Figure 2-2 Static Electricity Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Figure 2-3 Installation Procedure for No. 7 CCIS with Digital Interface . . . . . . . . . . . . . . . . . . . . 59 Figure 2-4 DTI Cable Connection via MDF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Figure 2-5 Location of the AP Slots and the LTC Connectors for DTI . . . . . . . . . . . . . . . . . . . . . 68 Figure 2-6 Example of Cable Connection via MDF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Figure 2-7 DTI Cable Connection via CONN Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Figure 2-8 Example of Cable Connection via the CONN Card . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Figure 2-9 Outline of Optical Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Figure 2-10 Example of MDF Cross Connection for M10 Card (1 of 2) . . . . . . . . . . . . . . . . . . . . . 73 Figure 2-10 Example of MDF Cross Connection for M10 Card (2 of 2) . . . . . . . . . . . . . . . . . . . . . . 74 Figure 2-11 Installation Procedure for No. 7 CCIS with Analog Interface . . . . . . . . . . . . . . . . . . . . 75 Figure 2-12 Cabling of RS NORM-4 CA-A/RS NORM-4S CA-A (for Common Signaling Data Link via MODEM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Figure 2-13 Cabling of LINE Cable (for Common Signaling Data Link via MODEM) . . . . . . . . . . . 77 Figure 2-14 Cabling of RS NORM-4 CA-A/RS NORM-4S CA-A (for Common Signalling Data Link via LDT/ODT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Figure 2-15 Location of the AP Slots and the LTC Connectors for CCH . . . . . . . . . . . . . . . . . . . . 79 Figure 2-16 Cabling of LINE Cable (for Common Signalling Data Link via LDT/ODT) . . . . . . . . . . 80 Figure 3-1 Programming Procedure (for No. 7 CCIS with Digital Interface) . . . . . . . . . . . . . . . . . 83 Figure 3-2 Programming Procedure (for No. 7 CCIS with Analog Interface) . . . . . . . . . . . . . . . . 108 Figure 4-1 Mounting Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 Figure 5-1 Loop-Back Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 Figure 5-2 Loop-Back Test Cable Connection (for Twisted-Pair Cable) . . . . . . . . . . . . . . . . . . . . 305 Figure 5-3 Loop-Back Test Cable Connection (for Coaxial Cable) . . . . . . . . . . . . . . . . . . . . . . . . 306
NEAX2000 IVS2 CCIS System ManualPage vi ND-70918 (E), Issue 1.0 LIST OF TABLES Table TitlePage Table 1-1 Card Name and Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Table 1-2 System Capacity for No. 7 CCIS with Digital Interface . . . . . . . . . . . . . . . . . . . . . . . . 16 Table 1-3 System Capacity for No. 7 CCIS with Analog Interface . . . . . . . . . . . . . . . . . . . . . . . . 16 Table 1-4 Number of Time Slots Required per DTI/CCH/AP00 Card (for No. 7 CCIS with Digital Interface) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Table 1-5 Number of Time Slots Required per CCH/AP00 Card (for No. 7 CCIS with Analog Interface) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Table 1-6 Transmission Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Table 1-7 12-Multi Frame Bit Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Table 1-8 24-Multi Frame Bit Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Table 1-9 Time Slot Assignment of 30-DTI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Table 1-10 List of No. 7 CCIS Service Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 2-1 Required Equipment for No. 7 CCIS with Digital Interface . . . . . . . . . . . . . . . . . . . . . 57 Table 2-2 Required Equipment and Cable for No. 7 CCIS with Analog Interface . . . . . . . . . . . . 58 Table 4-1 List of Required Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 Table 5-1 Alarm Indications on the 24DTI Card (Loop-Back Test) . . . . . . . . . . . . . . . . . . . . . . . 307 Table 5-2 Alarm Indications on the 30DTI Card (Loop-Back Test) . . . . . . . . . . . . . . . . . . . . . . . 308 Table 5-3 Alarm Indications on 24DTI (Interoffice Transmission Line Test) . . . . . . . . . . . . . . . . 311 Table 5-4 Alarm Indications on 30DTI (Interoffice Transmission Line Test) . . . . . . . . . . . . . . . . 312
Introduction Purpose NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 1 INTRODUCTION PURPOSE This manual explains the installation and programming procedure for providing No. 7 Common Channel Inter-Office Signaling (No. 7 CCIS) system to the NEAX2000 IVS 2/NEAX7400 ICS M100MX/NEAX2000 INTEGRATED VOICE SERVER. OUTLINE OF THIS MANUAL This manual consists of five chapters. The contents of CHAPTER 1 through 5 are outlined below. CHAPTER 1 GENERAL INFORMATION This chapter explains the system outline, the name and functions of circuit cards required, system capacity, time slot assignment condition, system specifications, available service features with No. 7 CCIS, and network structure conditions for CCIS system. CHAPTER 2 INSTALLATION This chapter explains the required equipment and installation procedure. CHAPTER 3 SYSTEM DATA PROGRAMMING This chapter explains the programming procedure for providing CCIS system, and also explains the general description, programming procedure, operating procedure, and hardware requirement of each service feature. CHAPTER 4 CIRCUIT CARD INFORMATION This chapter explains the mounting location, the meaning of lamp indications, and the method of switch settings of each circuit card for the No. 7 CCIS system. CHAPTER 5 OPERATION TEST This chapter explains inter-office test procedure relating to the basic DTI functions.
NEAX2000 IVS2 Maintenance ManualPage 2 ND-70926 (E), Issue 1.0 Introduction Terms in This Manual TERMS IN THIS MANUAL Usually, PBX system is designated as “PBX” or “system”. When we must distinguish between the PBX systems, they are designated as follows. IVS: NEAX2000 IVS 2/NEAX7400 ICS M100MX/NEAX2000 INTEGRATED VOICE SERVER IMX: NEAX2400 IMS (IMX)/NEAX7400 ICS M140MX or more/NEAX7400 IMX M240 or more REFERENCE MANUAL During installation, refer also to the manuals below: Command Manual Describes Customer Administration Terminal (CAT) operation, command function and setting data required for programming the system, and Resident System Program. Office Data Programming Manual Contains the Customer Specification Sheet and Office Data Programming Sheet. MATWorX Studio User’s Guide Describes the Maintenance Administration Terminal (MATWorX Studio) program operation. Maintenance Manual Describes maintenance service features and the recommended trouble shooting procedure. Installation Procedure Manual Describes the installation procedure for the PBX system.
NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 3 CHAPTER 1 GENERAL INFORMATION This chapter explains the system outline, the name and functions of circuit cards required, system capacity, time slot assignment condition, system specifications, available service features with No. 7 CCIS, and network structure considerations for CCIS system.
NEAX2000 IVS2 CCIS System ManualPage 4 ND-70918 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION System Outline SYSTEM OUTLINE The PBX can be interfaced with a Public Network or Tie Line Network by No. 7 CCIS Signaling. For adding No. 7 CCIS to the system, it is necessary to install the 24/30 channel Digital Trunk Interface (DTI) for a digital network or LDT (Loop Dial Trunk)/ODT (2 wire E&M or 4 wire E&M Trunk) for an analog network via a MODEM, and a Phase Locked Oscillator (PLO) for network synchronization. Also, it is necessary to install a Common Channel Handler (CCH). The CCH receives/transmits common signaling data from/to the distant office. In each local office, the PBX can provide Centralized Billing function in addition to a variety of inter-office service features. NOTE:Centralized Day/Night Mode Change, Centralized MAT and Number Portability feature require CCIS No. 7 networking with the IMX. For addition of the Centralized Billing function, an Application Processor (AP) or Built-in SMDR of MP card (for Local Office only) is required. Figure 1-1 shows the system outline of No. 7 CCIS for the PBX. Figure 1-1 No. 7 CCIS System Outline PBX 24/30 CH24/30 CHANNEL PCM DIGITAL LINE CLOCK SIGNAL DTI MP (PLO)MP (PLO) DIGITAL PBX CCH AP DTI DTI : 24/30 Channel Digital Trunk Interface CCH: Common Channel Handler PLO : Phase Locked Oscillator AP : Application Processor for Centralized Billing CCH
CHAPTER 1 GENERAL INFORMATION System Outline NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 5 DTI The Digital Trunk Interface (DTI) interfaces the PBX directly to a 24/30 channel PCM transmission line. The DTI has the following functions. For 24-DTI: Unipolar/Bipolar Conversion (AMI Format/B8ZS Format) Signaling Insertion/Extraction Alarm Detection/Insertion Digital PAD on Voice Signal Transmission Loop-Back Test (Local/Remote Loop Back) Cyclic Redundancy Checking (based on ITU-T Rec. G704) For 30-DTI: Unipolar/Bipolar Conversion (HDB3 Format) Signaling Insertion/Extraction Alarm Detection/Insertion Digital PAD on Voice Signal Transmission Cyclic Redundancy Checking (based on ITU-T Rec. G704) Channel Associated Signaling (based on ITU-T Rec. 0421 Digital R2 Signaling Code) For connection of a 24-DTI and transmission line, twisted-pair cables are used, and for connection of a 30-DTI and transmission line, twisted-pair cables or coaxial cables are used. CCH The Common Channel Handler (CCH) card provides a common channel signal through the DTI to a No. 7 CCIS network, and it is responsible for signaling between the PBX and the No. 7 CCIS network under control of the MP.
NEAX2000 IVS2 CCIS System ManualPage 6 ND-70918 (E), Issue 1.0 CHAPTER 1 GENERAL INFORMATION System Outline PLO The Phase Locked Oscillator (PLO) is responsible for providing synchronization between the TDSW and another office. In this system, the internal PLO equipped with the MP card is used. The PLO generates a synchronized clock signal according to the source clock signals supplied from the source office within the network, and supplies the generated clock signal to the TDSW. The PLO is supplied with clock signals extracted from the DTI. The PLO can be equipped with two clock supply routes; one is the route from the source office, and the other is a standby route from a sub-source office. When no clock signals from the source and the sub-source office arrive due to a transmission line failure, the PLO keeps generating the clock signals in phase with the previous source clock. Figure 1-2 shows an example of clock supply route configuration. Figure 1-2 Clock Supply Route PLO TDSW SOURCE OFFICE ~ SOURCE CLOCK RECEIVER/LOCAL-RECEIVER OFFICE PBX DTI DTI TDSW RECEIVER OFFICE DTI DTI DTI TDSW SUB-SOURCE OFFICE PLO DTI DTI DTI TDSW DTI DTI PLO PLO:DIRECTION OF CLOCK SIGNAL SUPPLY
CHAPTER 1 GENERAL INFORMATION System Outline NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 7 No. 7 CCIS The PBX can provide No. 7 CCIS via either a digital network or an analog network. Regardless of the relevant network being a digital network or an analog network, CCH (Common Channel Handler) to control the common signaling channel is required. DIGITAL NETWORK When No. 7 CCIS is provided via a digital network, the CCH is connected to the DTI by a fixed path in the TDSW and transmits/receives common signaling data to/from the distant office through a predetermined channel. Voice signals are transmitted/received on each line basis through other channels. Figure 1-3 shows the system configuration of No. 7 CCIS provided via a digital network. Figure 1-3 No. 7 CCIS with DTI TDSW DIGITAL PBX DTI 24/30 CHANNEL PCM DIGITAL LINE DTI CCH TDSWPBX DTI : 24/30 Channel Digital Trunk Interface CCH : Common Channel Handler PLO : Phase Locked Oscillator MP (PLO)MP (PLO) CCH