    							 NEAX2000 IVS2 CCIS System ManualPage iv  ND-70918 (E), Issue 1.0
    TABLE OF CONTENTS
    Page
    CHAPTER 4 CIRCUIT CARD INFORMATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   259
    HOW TO READ THIS CHAPTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   260
    MOUNTING LOCATION OF CIRCUIT CARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   261
    Circuit Card Mounting Slots  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
    LIST OF REQUIRED CARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   262
    PN-CP14 (MP)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  263
    PN-CP15 (FP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  268
    PN-AP00-B (AP00) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  270
    PN-24DTA-C (DTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  276
    PN-30DTC-A (DTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  282
    PN-SC00 (CCH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  288
    PZ-M537 (EXPMEM)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  291
    PZ-M542 (CONN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  294
    PZ-M557 (CONN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  296
    PN-2LDTA (LDT)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  298
    PN-M10 (M10)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  299
    PN-2ODTA (ODT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  301
    PN-2ODTB (ODT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  302
    CHAPTER 5 OPERATION TEST  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   303
    LOOP-BACK TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   304
    INTEROFFICE TRANSMISSION LINE TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   310
    PLO OPERATION TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  313
    Clock Signal Generation Test   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  313
    Clock Signal Synchronization Test   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  314
    Interoffice Synchronization Test   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  316
    Source Office Mode Test  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 
    						
    							LIST OF FIGURES
    Figure TitlePage
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page v
    Figure 1-1 No. 7 CCIS System Outline  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
    Figure 1-2 Clock Supply Route  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6
    Figure 1-3 No. 7 CCIS with DTI   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7
    Figure 1-4 No. 7 CCIS with LDT/ODT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8
    Figure 1-5 Centralized Billing   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
    Figure 1-6 Accommodation of DTI/CCH into TDSW  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17
    Figure 1-7 Time Slot Allocation for DTI  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
    Figure 1-8 CCH Time Slot Assignment (for No. 7 CCIS with Digital Interface)  . . . . . . . . . . . . . . .  20
    Figure 1-9 CCH Time Slot Assignment (for No. 7 CCIS with Analog Interface)  . . . . . . . . . . . . . .  21
    Figure 1-10 Frame Configuration of 24-DTI (12-Multi Frame)   . . . . . . . . . . . . . . . . . . . . . . . . . . . .  25
    Figure 1-11 Frame Configuration of 24-DTI (24-Multi Frame)   . . . . . . . . . . . . . . . . . . . . . . . . . . . .  27
    Figure 1-12 Frame Configuration of 30-DTI   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  30
    Figure 1-13 Network Structuring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  35
    Figure 1-14 Example of Station Number (Closed Numbering)  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  42
    Figure 1-15 Example of Office Code and Station Number (Open Numbering)  . . . . . . . . . . . . . . . .  42
    Figure 2-1 Static Electricity Guard   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  54
    Figure 2-2 Static Electricity Guard   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  55
    Figure 2-3 Installation Procedure for No. 7 CCIS with Digital Interface   . . . . . . . . . . . . . . . . . . . .  59
    Figure 2-4 DTI Cable Connection via MDF  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  67
    Figure 2-5 Location of the AP Slots and the LTC Connectors for DTI   . . . . . . . . . . . . . . . . . . . . .  68
    Figure 2-6 Example of Cable Connection via MDF  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  69
    Figure 2-7 DTI Cable Connection via CONN Card  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  70
    Figure 2-8 Example of Cable Connection via the CONN Card  . . . . . . . . . . . . . . . . . . . . . . . . . . .  71
    Figure 2-9 Outline of Optical Cable Connection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  72
    Figure 2-10 Example of MDF Cross Connection for M10 Card (1 of 2)   . . . . . . . . . . . . . . . . . . . . .  73
    Figure 2-10  Example of MDF Cross Connection for M10 Card (2 of 2) . . . . . . . . . . . . . . . . . . . . . . 74
    Figure 2-11 Installation Procedure for No. 7 CCIS with Analog Interface  . . . . . . . . . . . . . . . . . . . .  75
    Figure 2-12 Cabling of RS NORM-4 CA-A/RS NORM-4S CA-A 
    (for Common Signaling Data Link via MODEM)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   77
    Figure 2-13 Cabling of LINE Cable (for Common Signaling Data Link via MODEM)  . . . . . . . . . . .  77
    Figure 2-14 Cabling of RS NORM-4 CA-A/RS NORM-4S CA-A
    (for Common Signalling Data Link via LDT/ODT)   . . . . . . . . . . . . . . . . . . . . . . . . . . . .   78
    Figure 2-15 Location of the AP Slots and the LTC Connectors for CCH   . . . . . . . . . . . . . . . . . . . .  79
    Figure 2-16 Cabling of LINE Cable (for Common Signalling Data Link via LDT/ODT)  . . . . . . . . . .  80
    Figure 3-1 Programming Procedure (for No. 7 CCIS with Digital Interface)  . . . . . . . . . . . . . . . . .  83
    Figure 3-2 Programming Procedure (for No. 7 CCIS with Analog Interface)   . . . . . . . . . . . . . . . .  108
    Figure 4-1 Mounting Location  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  261
    Figure 5-1 Loop-Back Test  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  304
    Figure 5-2 Loop-Back Test Cable Connection (for Twisted-Pair Cable)  . . . . . . . . . . . . . . . . . . . .  305
    Figure 5-3 Loop-Back Test Cable Connection (for Coaxial Cable)  . . . . . . . . . . . . . . . . . . . . . . . .  306 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage vi  ND-70918 (E), Issue 1.0
    LIST OF TABLES
    Table TitlePage
    Table 1-1 Card Name and Function    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13
    Table 1-2 System Capacity for No. 7 CCIS with Digital Interface   . . . . . . . . . . . . . . . . . . . . . . . .  16
    Table 1-3 System Capacity for No. 7 CCIS with Analog Interface  . . . . . . . . . . . . . . . . . . . . . . . .  16
    Table 1-4 Number of Time Slots Required per DTI/CCH/AP00 Card 
    (for No. 7 CCIS with Digital Interface)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   22
    Table 1-5 Number of Time Slots Required per CCH/AP00 Card
    (for No. 7 CCIS with Analog Interface)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   23
    Table 1-6 Transmission Characteristics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  24
    Table 1-7 12-Multi Frame Bit Assignment   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  26
    Table 1-8 24-Multi Frame Bit Assignment   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  28
    Table 1-9 Time Slot Assignment of 30-DTI   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  31
    Table 1-10 List of No. 7 CCIS Service Features     . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  32
    Table 2-1 Required Equipment for No. 7 CCIS with Digital Interface   . . . . . . . . . . . . . . . . . . . . .  57
    Table 2-2 Required Equipment and Cable for No. 7 CCIS with Analog Interface   . . . . . . . . . . . .  58
    Table 4-1 List of Required Cards  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  262
    Table 5-1 Alarm Indications on the 24DTI Card (Loop-Back Test)   . . . . . . . . . . . . . . . . . . . . . . .  307
    Table 5-2 Alarm Indications on the 30DTI Card (Loop-Back Test)   . . . . . . . . . . . . . . . . . . . . . . .  308
    Table 5-3 Alarm Indications on 24DTI (Interoffice Transmission Line Test)   . . . . . . . . . . . . . . . .  311
    Table 5-4 Alarm Indications on 30DTI (Interoffice Transmission Line Test)   . . . . . . . . . . . . . . . .  312 
    						
    							Introduction
    Purpose
    NEAX2000 IVS2 Maintenance Manual   ND-70926 (E), Issue 1.0  Page 1
    INTRODUCTION
    PURPOSE
    This manual explains the installation and programming procedure for providing No. 7 Common
    Channel Inter-Office Signaling (No. 7 CCIS) system to the NEAX2000 IVS
    2/NEAX7400 ICS
    M100MX/NEAX2000 INTEGRATED VOICE SERVER.
    OUTLINE OF THIS MANUAL
    This manual consists of five chapters. The contents of CHAPTER 1 through 5 are outlined below.
    CHAPTER 1 GENERAL INFORMATION
    This chapter explains the system outline, the name and functions of circuit cards required,
    system capacity, time slot assignment condition, system specifications, available service features
    with No. 7 CCIS, and network structure conditions for CCIS system.
    CHAPTER 2 INSTALLATION
    This chapter explains the required equipment and installation procedure.
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    This chapter explains the programming procedure for providing CCIS system, and also explains
    the general description, programming procedure, operating procedure, and hardware
    requirement of each service feature.
    CHAPTER 4 CIRCUIT CARD INFORMATION
    This chapter explains the mounting location, the meaning of lamp indications, and the method of
    switch settings of each circuit card for the No. 7 CCIS system.
    CHAPTER 5 OPERATION TEST
    This chapter explains inter-office test procedure relating to the basic DTI functions. 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 2  ND-70926 (E), Issue 1.0
    Introduction
    Terms in This Manual
    TERMS IN THIS MANUAL
    Usually, PBX system is designated as “PBX” or “system”.
    When we must distinguish between the PBX systems, they are designated as follows.
    IVS: NEAX2000 IVS
    2/NEAX7400 ICS M100MX/NEAX2000 INTEGRATED VOICE SERVER
    IMX: NEAX2400 IMS (IMX)/NEAX7400 ICS M140MX or more/NEAX7400 IMX M240 or more
    REFERENCE MANUAL
    During installation, refer also to the manuals below:
    Command Manual Describes Customer Administration Terminal (CAT)
    operation, command function and setting data required for
    programming the system, and Resident System Program.
    Office Data Programming Manual Contains the Customer Specification Sheet and Office Data
    Programming Sheet.
    MATWorX Studio User’s Guide Describes the Maintenance Administration Terminal
    (MATWorX Studio) program operation.
    Maintenance Manual Describes maintenance service features and the
    recommended trouble shooting procedure.
    Installation Procedure Manual Describes the installation procedure for the PBX system. 
    						
    							NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 3
    CHAPTER 1
    GENERAL INFORMATION
    This chapter explains the system outline, the name and functions of
    circuit cards required, system capacity, time slot assignment
    condition, system specifications, available service features with No. 7
    CCIS, and network structure considerations for CCIS system. 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 4  ND-70918 (E), Issue 1.0
    CHAPTER 1  GENERAL INFORMATION
    System Outline
    SYSTEM OUTLINE
    The PBX can be interfaced with a Public Network or Tie Line Network by No. 7 CCIS Signaling.
    For adding No. 7 CCIS to the system, it is necessary to install the 24/30 channel Digital Trunk
    Interface (DTI) for a digital network or LDT (Loop Dial Trunk)/ODT (2 wire E&M or 4 wire E&M
    Trunk) for an analog network via a MODEM, and a Phase Locked Oscillator (PLO) for network
    synchronization. Also, it is necessary to install a Common Channel Handler (CCH). 
    The CCH receives/transmits common signaling data from/to the distant office. In each local
    office, the PBX can provide Centralized Billing function in addition to a variety of inter-office
    service features.
    NOTE:Centralized Day/Night Mode Change, Centralized MAT and Number Portability feature
    require CCIS No. 7 networking with the IMX.
    For addition of the Centralized Billing function, an Application Processor (AP) or Built-in SMDR
    of MP card (for Local Office only) is required. Figure 1-1 shows the system outline of No. 7 CCIS
    for the PBX.
    Figure 1-1  No. 7 CCIS System Outline
    PBX
    24/30 CH24/30 CHANNEL PCM 
    DIGITAL LINE 
    CLOCK SIGNAL DTI
    MP 
    (PLO)MP 
    (PLO) DIGITAL 
    PBX
    CCH
    AP
    DTI
    DTI : 24/30 Channel Digital Trunk Interface CCH: Common Channel Handler
    PLO : Phase Locked Oscillator AP : Application Processor for Centralized Billing
    CCH 
    						
    							CHAPTER 1  GENERAL INFORMATION
    System Outline
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 5
    DTI
    The Digital Trunk Interface (DTI) interfaces the PBX directly to a 24/30 channel PCM
    transmission line. The DTI has the following functions.
    For 24-DTI:
     Unipolar/Bipolar Conversion (AMI Format/B8ZS Format)
     Signaling Insertion/Extraction
     Alarm Detection/Insertion
     Digital PAD on Voice Signal Transmission
     Loop-Back Test (Local/Remote Loop Back)
     Cyclic Redundancy Checking (based on ITU-T Rec. G704)
    For 30-DTI:
     Unipolar/Bipolar Conversion (HDB3 Format)
     Signaling Insertion/Extraction
     Alarm Detection/Insertion
     Digital PAD on Voice Signal Transmission
     Cyclic Redundancy Checking (based on ITU-T Rec. G704)
     Channel Associated Signaling (based on ITU-T Rec. 0421 Digital R2 Signaling Code)
    For connection of a 24-DTI and transmission line, twisted-pair cables are used, and for
    connection of a 30-DTI and transmission line, twisted-pair cables or coaxial cables are used.
    CCH
    The Common Channel Handler (CCH) card provides a common channel signal through the DTI
    to a No. 7 CCIS network, and it is responsible for signaling between the PBX and the No. 7 CCIS
    network under control of the MP. 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 6  ND-70918 (E), Issue 1.0
    CHAPTER 1  GENERAL INFORMATION
    System Outline
    PLO
    The Phase Locked Oscillator (PLO) is responsible for providing synchronization between the
    TDSW and another office. In this system, the internal PLO equipped with the MP card is used.
    The PLO generates a synchronized clock signal according to the source clock signals supplied
    from the source office within the network, and supplies the generated clock signal to the TDSW.
    The PLO is supplied with clock signals extracted from the DTI. The PLO can be equipped with
    two clock supply routes; one is the route from the source office, and the other is a standby route
    from a sub-source office. When no clock signals from the source and the sub-source office arrive
    due to a transmission line failure, the PLO keeps generating the clock signals in phase with the
    previous source clock.
    Figure 1-2 shows an example of clock supply route configuration.
    Figure 1-2  Clock Supply Route
    PLO
    TDSW SOURCE OFFICE
    ~
    SOURCE
    CLOCK
    RECEIVER/LOCAL-RECEIVER OFFICE
    PBX
    DTI
    DTI TDSW
    RECEIVER OFFICE
    DTI
    DTI
    DTI TDSW
    SUB-SOURCE OFFICE
    PLO
    DTI
    DTI
    DTI
    TDSW
    DTI
    DTI
    PLO
    PLO:DIRECTION OF CLOCK
    SIGNAL SUPPLY 
    						
    							CHAPTER 1  GENERAL INFORMATION
    System Outline
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 7
    No. 7 CCIS
    The PBX can provide No. 7 CCIS via either a digital network or an analog network. Regardless
    of the relevant network being a digital network or an analog network, CCH (Common Channel
    Handler) to control the common signaling channel is required.
    DIGITAL NETWORK
    When No. 7 CCIS is provided via a digital network, the CCH is connected to the DTI by a fixed
    path in the TDSW and transmits/receives common signaling data to/from the distant office
    through a predetermined channel. Voice signals are transmitted/received on each line basis
    through other channels. 
    Figure 1-3 shows the system configuration of No. 7 CCIS provided via a digital network.
    Figure 1-3  No. 7 CCIS with DTI
    TDSW DIGITAL PBX
    DTI
    24/30 CHANNEL PCM
    DIGITAL LINE
    DTI
    CCH
    TDSWPBX
    DTI : 24/30 Channel Digital Trunk Interface
    CCH : Common Channel Handler
    PLO : Phase Locked Oscillator
    MP
    (PLO)MP
    (PLO)
    CCH 
    						