NEC Neax 2000 Ivs2 Ccis System Manual
Have a look at the manual NEC Neax 2000 Ivs2 Ccis System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
NEAX2000 IVS2 CCIS System ManualPage 148 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Call Transfer-Attendant-CCIS NOTE 1:In the Inter-Tenant Connection Assignment, the Tenant number should be assigned as 01-63. 00 should not be used if connecting to a PBX. NOTE 2:Refer to Numbering Plan Assignment and assign a dial code to call the attendant by the LCR feature. Operating Procedure To transfer a call to an Attendant Console: (1) While engaged in a Central Office trunk call, switch hook flash; receive feature dial tone. (2) Dial the Operator Access Code. (3) The ATND lamp on the Attendant Console flashes and the buzzer sounds. The station receives ringback tone. To answer from the Attendant Console: (1) Refer to the “IMX Attendant Console User Guide”. If the station wishes to return to the Central Office trunk call while the Attendant Console is being called: (1) Switch hook flash. the ATND lamp is extinguished at the Attendant Console and the buzzer stops. (2) Ringback tone ceases; the station returns to the Central Office trunk call.
CHAPTER 3 SYSTEM DATA PROGRAMMING Calling Name Display-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 149 CALLING NAME DISPLAY-CCIS General Description This feature provides a display indicating the calling/called par ty’s name, at another switching office, on the LCD of a D term or an Attendant Console. Programming DESCRIPTION DATA Provide the system with the Name Display service.(1) (2)255: Name Display 1 : To provide Specify the number of digits sent to the CCIS network to 24 digits.(1) (2)379: Number of dialed digits 0: 24 digits Specify the time to go back to date and time display after the call is answered.(1) (2)120 0 : 10 sec. later 1 : 6 sec. later Specify the duration to display the name. (1) (2)121 0 : Until call finished 1 : As per CM08>120 Assign the access code for station user name entry from an individual station. (1) (2)Y=0-3 Numbering Plan Group 0-3 X-XXXX: Access Code (0-9, *, #) A110 Assign a trunk name number to each trunk route. (1) (2)YY=03 00-63: Trunk Route No. 00-14 : Trunk Name No. 15 : Kind of trunk route assigned by CM35 YY=00 are displayed 16-63 : Trunk Name No. Provide each CCH number with Name Display feature. (1) (2)YY=26 Name Display 0-7: CCH No. 0-7 0: To provide CM20 START CM08 CM35 A CMA7
NEAX2000 IVS2 CCIS System ManualPage 150 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Calling Name Display-CCIS NOTE 1:The maximum number of stations that can be provided with user’s name display is 384. The maximum number of characters per name is eight, including spaces. NOTE 2:User’s name can be assigned to Single Line Telephones, and cannot be assigned to the Attendant Console. NOTE 3:The trunk name display is provided on a trunk route basis. The maximum amount of characters in the trunk name display is four. And the maximum number of trunk routes assignable is 16. NOTE 4:A name currently programmed can be changed by overwriting with a new name, or by inserting a blank space as the first character. This will cancel the existing name. Operating Procedure No manual operation is required. DESCRIPTION DATA Enter the desired user’s name to each sta- tion number with Character Codes or char- acters. (1) (2)Y=0 By Character Code X-XXXXXXXX: Station No. 20-7F: Character Code Max. 32 digits (See CM77 in the Command Manual) (1) (2)Y=1 By character X-XXXXXXXX: Station No. A-Z, 0-9: Character Max. 16 characters Assign the desired trunk name to each trunk route by Y=2 or Y=3. (1) (2)Y=2 By character Code 00-14, 16-63: Trunk Name No. assigned by CM35 YY=03. Character Code 20-7F: (See CM77 in the Command Manual) (1) (2)Y=3 By character 00-14, 16-63: Trunk Name No. assigned by CM35 YY=03. A-Z, 0-9: Character Code Max. 4 characters END CM77 A
CHAPTER 3 SYSTEM DATA PROGRAMMING Calling Number Display-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 151 CALLING NUMBER DISPLAY-CCIS General Description This feature provides a display indicating the calling/called p arty’s number, at another switching office via the CCIS network, on the LCD of a D term or an Attendant Console/Smar t Console. To transfer the calling par ty number received from the network (ISDN CPN/Caller-ID/MFC or T1- ANI) transparently between the offices on the CCIS network, assign the following data. The calling party number sent from the network over CCIS can be display on the LCD of the station of another office over CCIS, and can be sent to the SMDR. It can be sent to also the MCI, if the system provides the MCI with ANI. Programming DESCRIPTION DATA Provide the system with the Name Display service.(1) (2)255 1 : To provide Office AOffice B ISDN CPN/ Caller-ID/ MFC-ANI/ T1-ANICalling Party NumberCCIS TransparentDisplay of Calling Party Number on LCD Sending of Calling Par ty Number to MCI/SMDR START CM08 A
NEAX2000 IVS2 CCIS System ManualPage 152 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Calling Number Display-CCIS The conditions for transferring calling party number over CCIS related to the Call Transfer, Call Forwarding feature are described below. When the Station 300 on the Office B answers the call from the network, and transfers the call to the Station 301 on the Office B, the calling party number will be displayed on the Station 301. When the Station 200 on the Office A answers the call from the network, and transfers the call to the Station 300 on the Office B, the calling party number will not be displayed on the Station 300. DESCRIPTION DATA Specify the number of digits sent to the CCIS network as 24 digits.(1) (2)379 0: 24 digits Provide each CCH channel with Name Display feature. (1) (2)YY=26 0-7: CCH Channel No. 0-7 0: To provide Provide each CCH channel with the information transferring service. (1) (2)YY=28 0-7: CCH Channel No. 0-7 0: To provide CMA7 END CM08 A ISDN CPN/ Caller-ID/ MFC-ANI/ T1-ANIOffice A Office B Calling Par ty NumberCCIS Call Transfer300301 The calling p a rty number can be displayed. ISDN CPN/ Caller-ID/ MFC-ANI/ T1-ANIOffice A Office B Calling Par ty Number CCIS 300200 The calling party number can not be displayed. Transfer
CHAPTER 3 SYSTEM DATA PROGRAMMING Calling Number Display-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 153 When the call from the network terminates to the Station 300 on the Office B and be forwarded to the Station 301 on the Office B, the calling party number will be displayed on the Station 301. When the call from the network terminates to the Station 200 on the Office A and be forwarded to the Station 300 on Office B, the calling par ty number will be displayed on the Station 300. Operating Procedure No manual operation is required. ISDN CPN/ Caller-ID/ MFC-ANI/ T1-ANI Office A Office B Calling Party NumberCCIS Call Forwarding 300301 The calling party number can be displayed. ISDN CPN/ Caller-ID/ MFC-ANI/ T1-ANIOffice A Office B Calling Party Number CCIS 300200 The calling party number can be displayed. Call Forwarding
NEAX2000 IVS2 CCIS System ManualPage 154 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Billing-CCIS CENTRALIZED BILLING-CCIS General Description This feature is used to collect billing information from each office within the network and to direct it to the associated center office. Billing information is then forwarded to the SMDR of center office. Programming Programming Summary NOTE:AP00 is required in Local Office/Tandem Office. NOTE NOTE DTI LOCAL OFFICE TANDEM OFFICE CCH DTI CCH DTI CENTER OFFICE CCH DTI CCH AP00 MPAP00AP00 MP SMDR TERMINAL MP END START AP INITIALIZATION SMDR WITH AP00 PROGRAMMING (2) Page 155 Page 158 Page 155 AP00 Page 162 Page 164 MP CENTER OFFICE AP INITIALIZATION SMDR WITH AP00 PROGRAMMING (1)Local OFFICE/ Tandem OFFICE LOCAL OFFICE TANDEM OFFICE OR CENTER OFFICE?MP (BUILT-IN SMDR) OR AP00? BUILT-IN SMDR PROGRAMMING
CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Billing-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 155 AP Initialization This section explains the data assignment to make the AP active. If the system already applied the AP related feature, you can skip the data assignment explained in this section. The AP should have already been activated if one of the following feature is applied: Station Message Detail Recording (SMDR), Message Center Interface (MCI), D term Time Information Management System (TIMS), Proper ty Management System (PMS), or Hotel printer. You can distinguish whether the AP is active by the RUN lamp indication. The RUN lamp flashes green when the AP is in active mode. When installing the AP00 at first time, do the following AP initialization. DESCRIPTION DATA Assign an AP number to the AP00 card. The AP number must match the SENSE switch setting on the AP00 card. (1) (2)Y=0 04-15, 20-31: AP No. 04: AP00 card On the AP00 card, set SW1 switch as shown below. SW1-4 should be set as follows; ON : The AP No. is 04-15 OFF : The AP No. is 20-31 Load the initial data into the AP00 card. (1) (2)0000 CCC Specify Local Office or Center Office for Centralized Billing-CCIS(1) (2)179 0 : Local Office 1 : Center OfficeSTART CM05 CMD101 A CMD001 INITIAL SW1 ON : POSITION TO BE SET 4 3 2 1 AP OFF LINE
NEAX2000 IVS2 CCIS System ManualPage 156 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Billing-CCIS DESCRIPTION DATA Allow the maximum number of Call Record for SMDR which is set to “5” by CMD001>80/100/120/140. NOTE:When the data is set to 1-27000, external alarm of memory overflow is available, if CM44, 2nd data=3002 is assigned.(1) (2)24 0 : No limitation 1-27000 : 1-27000 calls Assign the maximum number of Local of fice’s Call Record for Centralized Billing office. NOTE:When the data is set to 1-27000, external alarm of memory overflow is available, if CM44, 2nd data=3000 is assigned.(1) (2)26 0 : No record 1-27000 : 1-27000 calls Assign the maximum number of Call Record for SMDR/PMS which is set to “4” by CMD001>80/100/120/140. NOTE:When the data is set to 1-27000, external alarm of memory overflow is available, if CM44, 2nd data=3001 is assigned.(1) (2)29 0 : No record 1-27000 : 1-27000 calls CMD003 A B
CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Billing-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 157 DESCRIPTION DATA Initialize the billing memory. (1) (2)0000 CCC On the AP00 card, set the SW1 switch as shown below: SW1-4 should be set as follows: ON: The AP No. is 04-15 OFF: The AP No. is 20-31 NOTE 1:“DATA ERROR” will be indicated when CMD102>000: CCC is entered in case that the sum of all call records numbers set by second data of CMD003>23, 24, 25, 26, 28, 29, 30 exceeds the amount of call records number shown in NOTE 3, or System Data All Clear by CMD101 is not executed. NOTE 2:By entering the 1st data “0000”, status of the EXPMEM card (PZ-M537) will be displayed as shown below. CMD102 B END AP OFFLINE SW1 ON : POSITION TO BE SET 4 3 2 1 No EXPMEM on AP00 is Provided EXPMEM on AP00 is provided When CMD001>179 is set to 0 (Not a center office of Centralized Billing-CCIS)When CMD001>179 is set to other than 0 (Center office of Centralized Billing-CCIS)When CMD003>28 is set to 0 (No Call Record for CIS is provided)When CMD003>28 is set to other than 0 (Call Record for CIS is provided) 1600 800 27000 26000