    							 NEAX2000 IVS2 CCIS System ManualPage 178  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized Billing-CCIS
    Example 5: Data Assignment of CMD004>56
    To specify the billing office (Office B) in center office (Office C) when a station of Office A make
    an outgoing call through Office B:
    Data Assignment of Office A
    Command Code 1st Data 2nd Data Remarks
    CMD004 56 822
    OFFICE 
    A
    OFFICE 
    BOFFICE 
    C CCH0 Sta.
    CCH0CCH1SMDR
    PC: 00001 
    OFFICE NO.: 821
    PC: 00002 
    OFFICE NO.: 822PC: 00003 
    OFFICE NO.: 823 Billing Information 
    of Office B
    PC : Point Code
    CCH: Common Channel Handler
    PSTN 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized Day/Night Mode Change-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 179
    CENTRALIZED DAY/NIGHT MODE CHANGE-CCIS
    General Description
    This service feature switches the Day/Night Mode of a remote office, linked to the main office IMX
    via CCIS, in accordance with the Day/Night Mode switching on the Attendant Console at the main
    office.
    For Satellite Office
    If no Attendant Console is required in the Satellite Office, the following programming is 
    required.
    DESCRIPTION DATA
    Assign as ineffective Trunk Restriction 
    Class change by NT (Night) switch on 
    ATTCON/DESKCON.
    (1)
    (2)YY=02
    0-7: ATTCON No.
    1 : Ineffective
    Assign as ineffective outgoing call 
    restriction on Night Mode by NT switch on 
    ATTCON/DESKCON.
    (1)
    (2)YY=04
    0-7: ATTCON No.
    1 : Ineffective
    Assign as ineffective Day/Night Mode 
    Change by NT switch on ATTCON/
    DESKCON.
    (1)
    (2)YY=06
    0-7: ATTCON No.
    1 : Ineffective
    SATELLITE OFFICE MAIN OFFICE
    AT T
    CCIS
    IMX
    PBX
    START
    END
    CM60
    INITIAL
    INITIAL
    INITIAL 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 180  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized Day/Night Mode Change-CCIS
    To provide an indication on external equipment when Day/Night Mode status is changed by the
    Attendant Console at the Main Office, do the following programming.
    Hardware Requirements
    DK card × 1/External Equipment Interface on the MP card
    External Indicator (Bell, Lamp etc.) provided by the customer
    For cross connection of the External Indicator, refer to the Installation Procedure Manual.
    Operating Procedure
    Main Office:
    (1) The Attendant executes Day/Night Mode changeover operation using the normal Attendant 
    Consoles (no master) method or the master Attendant Console method.
    (2) After a specified time, the Day/Night Mode at the remote office is changed over.
    Remote Office:
    No manual operation required.
    DESCRIPTION DATA
    Assign the DK card to the required LEN.
    NOTE 1:The DK card number must be as-
    signed to the 1st LEN (Level 0) 
    and the 3rd LEN (Level 2) of 
    each LT slot.(1)
    (2)000-763: LEN
    E800-E831: DK Card No.
    For PIM0/PIM1: E800-E807
    For PIM2/PIM3: E808-E815
    For PIM4/PIM5: E816-E823
    For PIM6/PIM7: E824-E831
    NOTE 2:Circuit No. 3 of E831 is used 
    for built-in External 
    Equipment Interface of MP 
    card by setting CM44.
    Assign the function of CCIS Day/Night 
    status Indication to the DK card.(1)
    (2)XX Y: Circuit No.
    XX : 00-31: DK Card No. assigned by 
    CM10 E800-E831
    Y : 0-3: Circuit No.
    313 : Built-in External Equipment 
    Interface on MP card
    3601START
    END
    CM10
    CM44 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized MAT-CCIS (Future Enhancement)
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 181
    CENTRALIZED MAT-CCIS (FUTURE ENHANCEMENT)
    General Description
    All nodes in the multiple IMXs and IVSs through CCIS link can be maintained from the sole MAT
    installed in an IMX.
    When the fault occurs at an IVS, the fault information (node name, alarm kind) is displayed on at
    the Centralized MAT.
    • The IVS must be a subordinate office.
     The opposite office must be an IMX.
    A connection among IMX and two or more IVSs cannot provide the Centralized MAT feature.
     For the station number in integrated numbering plan through CCIS network, access code 
    for network station number set by CM20>811-818 is required.
    IMX
    IMXIMX
    IVS
    Fault Information
    Centralized MAT
    IVS
    Fault Information CCIS
    CCIS Fusion Network
    CCIS IMX
    Cannot connect IVS IVS 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 182  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized MAT-CCIS (Future Enhancement)
    Programming
    DESCRIPTION DATA
    Assign fault kind information and its 
    external alarm kind.
    Fault Kind number:
    01 : System Initialization
    04 : MP-FP/AP communication failure
    08 : FP/AP card down
    09 : Power failure
    12 : CS/ZT fault occurred
    16 : Battery exchange periodic alarm
    20 : DTI Line failure
    21 : DCH/BRT/PRT D-channel link 
    connection failure
    22 : CCH Link connection failure
    24 : Number of faulty trunks was more 
    than predetermined number.
    25 : The number of lockout stations was 
    more than predetermined number.
    26 : DLC card down
    27 : Synchronism of DPC missed
    28 : SMDR output buffer memory overflow
    2B : CS/ZT fault occurred.
    18 : FP/AP card returned to normal 
    condition.
    19 : Power failure returned to normal 
    condition.
    30 : DTI Line returned to normal 
    condition.
    31 : DCH/BRT/PRT D-channel link 
    connection returned to the normal 
    condition.
    32 : CCH Link connection returned to 
    normal condition.
    34 : Number of faulty trunks was less than 
    predetermined number.
    35 : Number of lockout stations restored 
    to less than predetermined number.
    36 : DLC card returned to normal 
    condition.
    38 : SMDR output buffer memory 
    returned to normal condition.
    3B : CS/ZT returned to normal condition.•
    (1)
    (2)Y=2
    Fault Kind No.: See left column
    External Alarm Kind
    0 : Fault Memory/No out put of 
    External Alarm
    1 : Fault Memory/External Alarm is MN 
    alarm
    2 : Fault Memory/External Alarm is MJ 
    alarm
    3 : Fault Memory/External Alarm Kind 
    is determined in standard data
    NONE : No fault memory store
    /No External Alarm outputSTART
    CMEA
    A 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized MAT-CCIS (Future Enhancement)
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 183
    DESCRIPTION DATA
    Specify the external alarm kind which is 
    automatically sent.
    (1)
    (2)Y=3
    00-02: External Alarm Kind set by 
    CMEA Y=2
    0 : Sent
    1 : Not sent
    Specify the contents which is sent to the 
    Integrated Maintenance office as external 
    alarm kind.
    (1)
    (2)Y=4
    01: Kind of Information Transferred
    2: External Alarm Kind
    Specify the Point Code of the office, which 
    the fault information is sent to.
    (1)
    (2)Y=4
    05: Destination office’s point code to 
    which the fault information 
    transferred
    1-16367: Point Code
    Assign the name of own office.
    (1)
    (2)Y=5
    01: With Character Codes
    20-7F: Character Code
    (Max. 32 digits, 16 characters)
    (See CM77 in the Command Manual.)
    (1)
    (2)02: With Characters
    XX...XX:Office name
    (Max. 16 characters)
    CMEA
    A
    END 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 184  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized MAT-CCIS (Future Enhancement)
    NOTE:When a fault occurs, the external alarm kind registered in the IVS in the CCIS network
    is displayed on Centralized MAT on the IMX office as follows:
    DFTD 99/08/30 14:57 xxxxxxxxxxxxxxx
    SYSTEM MESSAGE 15-0 IVS MESSAGE
    xxxxxxxxx Aug 30 14:56
    LP00-0-ACT
    DFTD 99/08/30 14:57 XXXXXXXXX : Date of external alarm message output
    SYSTEM MESSAGE 15-0 IVS MESSAGE : Means that the fault information is transferred from
    the IVS.
    1: 3F EE 01 00 00 00 00 00
    3F  EE : Point Code of a IVS which external alarm message
    outputs
    01 : External alarm kind of fault information at the IVS
    01: MJ alarm
    02: MN alarm
    04: -alarm
    00 : Summary information (00 fixed)
    For details, refer to the manuals for the IMX.1: 3F EE 01 00 00 00 00 00 2:00 00 00 00 00 00 00 00 3:00 00 00 00 00 00 00 00
    4: 00 00 00 00 00 00 00 00
    5: 00 00 00 00 00 00 00 00 6:00 00 00 00 00 00 00 00 7:00 00 00 00 00 00 00 00
    8: 00 00 00 00 00 00 00 00 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Consultation Hold-All Calls-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 185
    CONSULTATION HOLD-ALL CALLS-CCIS
    General Description
    This feature permits a station user within the CCIS network to hold any incoming/outgoing public
    network or Tie Line call while originating a call to another station within the CCIS network.
    Programming
    Operating Procedure
    Single-Line Telephone
    To hold the original call and place a second call from a Single-Line Telephone:
    (1) Press the hookswitch momentarily and receive feature dial tone.
    (2) The original call is placed on hold and receives Music On Hold, if provided.
    (3) Dial the second station number; receive ringback tone.
    (4) The second station answers; Consultation Hold-All Calls-CCIS is established.
    DESCRIPTION DATA
    Assign the Service Restriction Class C to 
    the required stations.
    (1)
    (2)YY=07
    X-XXXXXXXX: Station No.
    XX: 00-15 : Service Restriction 
    Class C
    Allow the Switch Hook Flash capability in 
    the Service Restriction Class C assigned 
    by CM12 YY=07.
    (1)
    (2)YY=90, 91 
    Switch Hook Flash on External Call
    00-15: Service Restriction Class C 
    assigned by CM12 YY=07
    1 : Allow (Special Dial Tone 
    Connection)
    When STA-A has a C.O. line on 
    Consultation Hold and is talking to STA-B. (1)
    (2)117
    0: Return to the original call.START
    END
    CM12
    CM15
    CM08 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 186  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Consultation Hold-All Calls-CCIS
    To return to the original call from a Single-Line Telephone:
    (1) Under any of the following conditions, the calling station can return to the original call by 
    pressing the switch hook:
    (a) The second station called is busy.
    (b) The calling station cannot gain access to the second station because of a restriction, 
    etc.
    (c) The second station does not answer.
    (2) If the second party hangs up, the calling station will automatically be returned to the original 
    call.
    (3) If the originating station switch hook flashes, a three-way call will be established.
    D
    term
    To hold a call and place a second call from a Dterm:
    (1) Press the TRANSFER key; receive feature dial tone.
    (2) The original call is placed on hold and receives Music On Hold, if provided.
    (3) Dial the second station number; receive ringback tone.
    (4) The second station answers; Consultation Hold-All Calls-CCIS is established.
    To return to the original call from a D
    term:
    (1) Under any of the following conditions, the calling station can return to the original call by 
    pressing the TRANSFER key.
    (a) The second station called is busy.
    (b) The calling station cannot gain access to the second station because of a restriction, 
    etc.
    (c) The second station does not answer.
    (2) If the second station hangs up, the calling station will automatically be returned to the 
    original call.
    (3) If the second station remains in the conversation, pressing the TRANSFER or ANSWER 
    key returns the original call to the calling station and the second call is held.
    (4) By pressing the CONF key, a Conference will be initiated. 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Data Line Security-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 187
    DATA LINE SECURITY-CCIS
    General Description
    This feature allows line circuits which are used for data transmission to be protected from
    following interruptions:
    Attendant Camp-On with Tone Indication (Attendant Camp-On)
    Attendant Camp-On with Tone Indication-CCIS
    Attendant Override
    Automatic Camp-On (Attendant Camp-On)
    Boss-Secretary-Message Waiting Lamp Control-D
    term
    (Boss/Secretary Calling)
    Boss-Secretary Override-D
    term (Boss/Secretary Calling)
    Boss-Secretary Transfer-D
    term (Boss/Secretary Calling)
    Busy Verification (Attendant Override)
    Busy Verification-CCIS
    Executive Right Of Way (Executive Override)
    Executive Right Of Way-D
    term (Executive Override)
    Programming
    Operating Procedure
    No manual operation is required.
    DESCRIPTION DATA
    Assign the function of Analogue Data 
    station (Single Line Station with FAX or 
    MODEM.) to required stations.
    (1)
    (2)YY=07 
    X-XXXXXXXX: Station No.
    0: Data stationSTART
    END
    CM13 
    						