NEAX2000 IVS2 CCIS System ManualPage 178 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Billing-CCIS Example 5: Data Assignment of CMD004>56 To specify the billing office (Office B) in center office (Office C) when a station of Office A make an outgoing call through Office B: Data Assignment of Office A Command Code 1st Data 2nd Data Remarks CMD004 56 822 OFFICE A OFFICE BOFFICE C CCH0 Sta. CCH0CCH1SMDR PC: 00001 OFFICE NO.: 821 PC: 00002 OFFICE NO.: 822PC: 00003 OFFICE NO.: 823 Billing Information of Office B PC : Point Code CCH: Common Channel Handler PSTN
CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Day/Night Mode Change-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 179 CENTRALIZED DAY/NIGHT MODE CHANGE-CCIS General Description This service feature switches the Day/Night Mode of a remote office, linked to the main office IMX via CCIS, in accordance with the Day/Night Mode switching on the Attendant Console at the main office. For Satellite Office If no Attendant Console is required in the Satellite Office, the following programming is required. DESCRIPTION DATA Assign as ineffective Trunk Restriction Class change by NT (Night) switch on ATTCON/DESKCON. (1) (2)YY=02 0-7: ATTCON No. 1 : Ineffective Assign as ineffective outgoing call restriction on Night Mode by NT switch on ATTCON/DESKCON. (1) (2)YY=04 0-7: ATTCON No. 1 : Ineffective Assign as ineffective Day/Night Mode Change by NT switch on ATTCON/ DESKCON. (1) (2)YY=06 0-7: ATTCON No. 1 : Ineffective SATELLITE OFFICE MAIN OFFICE AT T CCIS IMX PBX START END CM60 INITIAL INITIAL INITIAL
NEAX2000 IVS2 CCIS System ManualPage 180 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Day/Night Mode Change-CCIS To provide an indication on external equipment when Day/Night Mode status is changed by the Attendant Console at the Main Office, do the following programming. Hardware Requirements DK card × 1/External Equipment Interface on the MP card External Indicator (Bell, Lamp etc.) provided by the customer For cross connection of the External Indicator, refer to the Installation Procedure Manual. Operating Procedure Main Office: (1) The Attendant executes Day/Night Mode changeover operation using the normal Attendant Consoles (no master) method or the master Attendant Console method. (2) After a specified time, the Day/Night Mode at the remote office is changed over. Remote Office: No manual operation required. DESCRIPTION DATA Assign the DK card to the required LEN. NOTE 1:The DK card number must be as- signed to the 1st LEN (Level 0) and the 3rd LEN (Level 2) of each LT slot.(1) (2)000-763: LEN E800-E831: DK Card No. For PIM0/PIM1: E800-E807 For PIM2/PIM3: E808-E815 For PIM4/PIM5: E816-E823 For PIM6/PIM7: E824-E831 NOTE 2:Circuit No. 3 of E831 is used for built-in External Equipment Interface of MP card by setting CM44. Assign the function of CCIS Day/Night status Indication to the DK card.(1) (2)XX Y: Circuit No. XX : 00-31: DK Card No. assigned by CM10 E800-E831 Y : 0-3: Circuit No. 313 : Built-in External Equipment Interface on MP card 3601START END CM10 CM44
CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized MAT-CCIS (Future Enhancement) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 181 CENTRALIZED MAT-CCIS (FUTURE ENHANCEMENT) General Description All nodes in the multiple IMXs and IVSs through CCIS link can be maintained from the sole MAT installed in an IMX. When the fault occurs at an IVS, the fault information (node name, alarm kind) is displayed on at the Centralized MAT. • The IVS must be a subordinate office. The opposite office must be an IMX. A connection among IMX and two or more IVSs cannot provide the Centralized MAT feature. For the station number in integrated numbering plan through CCIS network, access code for network station number set by CM20>811-818 is required. IMX IMXIMX IVS Fault Information Centralized MAT IVS Fault Information CCIS CCIS Fusion Network CCIS IMX Cannot connect IVS IVS
NEAX2000 IVS2 CCIS System ManualPage 182 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized MAT-CCIS (Future Enhancement) Programming DESCRIPTION DATA Assign fault kind information and its external alarm kind. Fault Kind number: 01 : System Initialization 04 : MP-FP/AP communication failure 08 : FP/AP card down 09 : Power failure 12 : CS/ZT fault occurred 16 : Battery exchange periodic alarm 20 : DTI Line failure 21 : DCH/BRT/PRT D-channel link connection failure 22 : CCH Link connection failure 24 : Number of faulty trunks was more than predetermined number. 25 : The number of lockout stations was more than predetermined number. 26 : DLC card down 27 : Synchronism of DPC missed 28 : SMDR output buffer memory overflow 2B : CS/ZT fault occurred. 18 : FP/AP card returned to normal condition. 19 : Power failure returned to normal condition. 30 : DTI Line returned to normal condition. 31 : DCH/BRT/PRT D-channel link connection returned to the normal condition. 32 : CCH Link connection returned to normal condition. 34 : Number of faulty trunks was less than predetermined number. 35 : Number of lockout stations restored to less than predetermined number. 36 : DLC card returned to normal condition. 38 : SMDR output buffer memory returned to normal condition. 3B : CS/ZT returned to normal condition.• (1) (2)Y=2 Fault Kind No.: See left column External Alarm Kind 0 : Fault Memory/No out put of External Alarm 1 : Fault Memory/External Alarm is MN alarm 2 : Fault Memory/External Alarm is MJ alarm 3 : Fault Memory/External Alarm Kind is determined in standard data NONE : No fault memory store /No External Alarm outputSTART CMEA A
CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized MAT-CCIS (Future Enhancement) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 183 DESCRIPTION DATA Specify the external alarm kind which is automatically sent. (1) (2)Y=3 00-02: External Alarm Kind set by CMEA Y=2 0 : Sent 1 : Not sent Specify the contents which is sent to the Integrated Maintenance office as external alarm kind. (1) (2)Y=4 01: Kind of Information Transferred 2: External Alarm Kind Specify the Point Code of the office, which the fault information is sent to. (1) (2)Y=4 05: Destination office’s point code to which the fault information transferred 1-16367: Point Code Assign the name of own office. (1) (2)Y=5 01: With Character Codes 20-7F: Character Code (Max. 32 digits, 16 characters) (See CM77 in the Command Manual.) (1) (2)02: With Characters XX...XX:Office name (Max. 16 characters) CMEA A END
NEAX2000 IVS2 CCIS System ManualPage 184 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized MAT-CCIS (Future Enhancement) NOTE:When a fault occurs, the external alarm kind registered in the IVS in the CCIS network is displayed on Centralized MAT on the IMX office as follows: DFTD 99/08/30 14:57 xxxxxxxxxxxxxxx SYSTEM MESSAGE 15-0 IVS MESSAGE xxxxxxxxx Aug 30 14:56 LP00-0-ACT DFTD 99/08/30 14:57 XXXXXXXXX : Date of external alarm message output SYSTEM MESSAGE 15-0 IVS MESSAGE : Means that the fault information is transferred from the IVS. 1: 3F EE 01 00 00 00 00 00 3F EE : Point Code of a IVS which external alarm message outputs 01 : External alarm kind of fault information at the IVS 01: MJ alarm 02: MN alarm 04: -alarm 00 : Summary information (00 fixed) For details, refer to the manuals for the IMX.1: 3F EE 01 00 00 00 00 00 2:00 00 00 00 00 00 00 00 3:00 00 00 00 00 00 00 00 4: 00 00 00 00 00 00 00 00 5: 00 00 00 00 00 00 00 00 6:00 00 00 00 00 00 00 00 7:00 00 00 00 00 00 00 00 8: 00 00 00 00 00 00 00 00
CHAPTER 3 SYSTEM DATA PROGRAMMING Consultation Hold-All Calls-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 185 CONSULTATION HOLD-ALL CALLS-CCIS General Description This feature permits a station user within the CCIS network to hold any incoming/outgoing public network or Tie Line call while originating a call to another station within the CCIS network. Programming Operating Procedure Single-Line Telephone To hold the original call and place a second call from a Single-Line Telephone: (1) Press the hookswitch momentarily and receive feature dial tone. (2) The original call is placed on hold and receives Music On Hold, if provided. (3) Dial the second station number; receive ringback tone. (4) The second station answers; Consultation Hold-All Calls-CCIS is established. DESCRIPTION DATA Assign the Service Restriction Class C to the required stations. (1) (2)YY=07 X-XXXXXXXX: Station No. XX: 00-15 : Service Restriction Class C Allow the Switch Hook Flash capability in the Service Restriction Class C assigned by CM12 YY=07. (1) (2)YY=90, 91 Switch Hook Flash on External Call 00-15: Service Restriction Class C assigned by CM12 YY=07 1 : Allow (Special Dial Tone Connection) When STA-A has a C.O. line on Consultation Hold and is talking to STA-B. (1) (2)117 0: Return to the original call.START END CM12 CM15 CM08
NEAX2000 IVS2 CCIS System ManualPage 186 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Consultation Hold-All Calls-CCIS To return to the original call from a Single-Line Telephone: (1) Under any of the following conditions, the calling station can return to the original call by pressing the switch hook: (a) The second station called is busy. (b) The calling station cannot gain access to the second station because of a restriction, etc. (c) The second station does not answer. (2) If the second party hangs up, the calling station will automatically be returned to the original call. (3) If the originating station switch hook flashes, a three-way call will be established. D term To hold a call and place a second call from a Dterm: (1) Press the TRANSFER key; receive feature dial tone. (2) The original call is placed on hold and receives Music On Hold, if provided. (3) Dial the second station number; receive ringback tone. (4) The second station answers; Consultation Hold-All Calls-CCIS is established. To return to the original call from a D term: (1) Under any of the following conditions, the calling station can return to the original call by pressing the TRANSFER key. (a) The second station called is busy. (b) The calling station cannot gain access to the second station because of a restriction, etc. (c) The second station does not answer. (2) If the second station hangs up, the calling station will automatically be returned to the original call. (3) If the second station remains in the conversation, pressing the TRANSFER or ANSWER key returns the original call to the calling station and the second call is held. (4) By pressing the CONF key, a Conference will be initiated.
CHAPTER 3 SYSTEM DATA PROGRAMMING Data Line Security-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 187 DATA LINE SECURITY-CCIS General Description This feature allows line circuits which are used for data transmission to be protected from following interruptions: Attendant Camp-On with Tone Indication (Attendant Camp-On) Attendant Camp-On with Tone Indication-CCIS Attendant Override Automatic Camp-On (Attendant Camp-On) Boss-Secretary-Message Waiting Lamp Control-D term (Boss/Secretary Calling) Boss-Secretary Override-D term (Boss/Secretary Calling) Boss-Secretary Transfer-D term (Boss/Secretary Calling) Busy Verification (Attendant Override) Busy Verification-CCIS Executive Right Of Way (Executive Override) Executive Right Of Way-D term (Executive Override) Programming Operating Procedure No manual operation is required. DESCRIPTION DATA Assign the function of Analogue Data station (Single Line Station with FAX or MODEM.) to required stations. (1) (2)YY=07 X-XXXXXXXX: Station No. 0: Data stationSTART END CM13