Home > NEC > Communications System > NEC Neax 2000 Ivs2 Ccis System Manual

NEC Neax 2000 Ivs2 Ccis System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs2 Ccis System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 NEAX2000 IVS2 CCIS System ManualPage 298  ND-70918 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-2LDTA (LDT)
    PN-2LDTA (LDT)
    Locations of Lamps, Switches and Connectors 
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0, 1 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    BL1
    BL0 
    						
    							CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-M10 (M10)
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 299
    PN-M10 (M10)
    Location of Lamps, Switches and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    CK0 Green Remains lit when a Digital Trunk Interface is connected to No. 0 
    circuit on this card.
    CK1 Green Remains lit when a Digital Trunk Interface is connected to No. 1 
    circuit on this card.
    TALM Red Remains lit when optical output is stopped.
    RALM Red Remains lit when optical input is lost or stopped.
    CN1 TO OPTICAL CABLECK0 
    CK1 
    TA L M  
    RALM
    JP3
    JP4
    JP2
    JP1
    JP0 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 300  ND-70918 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-M10 (M10)
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    JP0, 1
    (Jumper pin)
    UPWhen connected to E1 (2M) Digital 
    Trunk Interface.
    DOWNWhen connected to T1 (1.5M) 
    Digital Trunk Interface.
    JP2 (Jumper pin)
    RightLine code: B8ZS* is provided 
    (For T1 interface) 
    *B8ZS: Bipolar Eight Zero 
    Substitution
    LeftLine code: B8ZS* is not provided
    (For T1 interface)
    *B8ZS: Bipolar Eight Zero 
    Substitution
    JP3 (Jumper pin)
    RightWhen connected to E1 (2M) Digital 
    Trunk Interface.
    LeftWhen connected to T1 (1.5M) 
    Digital Trunk Interface.
    JP4 (Jumper pin)
    UPWhen connected to E1 (2M) Digital 
    Trunk Interface.
    DOWNWhen connected to T1 (1.5M) 
    Digital Trunk Interface. 
    						
    							CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-2ODTA (ODT)
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 301
    PN-2ODTA (ODT)
    Locations of Lamps, Switches and Connectors
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0, 1 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    BL1
    BL0
    CN1 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 302  ND-70918 (E), Issue 1.0
    CHAPTER 4 CIRCUIT CARD INFORMATION
    PN-2ODTB (ODT)
    PN-2ODTB (ODT)
    Locations of Lamps, Switches and Connectors
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0, 1 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    BL1
    BL0
    CN1 
    						
    							NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 303
    CHAPTER 5
    OPERATION TEST
    This chapter explains inter-office test procedure relating to the basic
    DTI functions. 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 304  ND-70918 (E), Issue 1.0
    CHAPTER 5  OPERATION TEST
    LOOP-BACK TEST
    LOOP-BACK TEST
    A loop-back test is performed on the DTI card. At least two DTI cards are necessary. Operational
    tests are performed by the clock within the MP.
    STEP 1: Assign the system data for a performance test as shown in Figure 5-1.
    Figure 5-1  Loop-Back Test
    DP/PB TEL
    DP/PB TELTDSW
    LC
    LCDTI
    DTILOOP
    BACK 
    						
    							CHAPTER 5  OPERATION TEST
    LOOP-BACK TEST
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 305
    STEP 2: Connect the cable for loop-back test.
    (1) When using a twisted-pair cable:
    Figure 5-2 shows an example of the cable connection when the 24DTI/30DTI cards are 
    mounted in the AP05 and AP06 slot of PIM0.
    Figure 5-2  Loop-Back Test Cable Connection (for Twisted-Pair Cable)
    PIM0
    JPMDF
    24DTI/30DTI
    AP05 
    [LT05] 
    AA0
    BA0
    AA1
    BA117
    42
    18
    43T0-31
    32
    33
    34 LTC1
    PIM0
    JP
    AP06 
    [LT06] 
    AB0
    BB0
    AB1
    BB121
    46
    22
    47LOOP-BACK
    LTC1
    17
    42
    18
    43RA
    RB
    TA
    TB
    21
    46
    22
    47T0-39
    40
    41
    42
    24DTI/30DTI
    RA
    RB
    TA
    TB 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 306  ND-70918 (E), Issue 1.0
    CHAPTER 5  OPERATION TEST
    LOOP-BACK TEST
    (2) When using a coaxial cable:
    Figure 5-3 shows an example of the cable connection when the 30DTI cards are mounted 
    in the AP07 and AP08 slot of PIM0.
    Figure 5-3  Loop-Back Test Cable Connection (for Coaxial Cable)
    PIM0
    30DTI
    RCV
    TRS
    JPCONN CARD LTC2
    AP07
    [LT07]
    PIM0
    30DTI
    RCV
    TRS
    JPCONN CARD LTC2
    AP08
    [LT08]
    COAXIAL
    CONNECTOR
    COAXIAL
    CONNECTOR
    LOOP-
    BACK AE0
    BE0
    AE1
    BE19
    34
    10
    359
    34
    10
    35
    AF0
    BF0
    AF1
    BF19
    34
    10
    359
    34
    10
    35 
    						
    							CHAPTER 5  OPERATION TEST
    LOOP-BACK TEST
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 307
    STEP 3: Turn on the operating power. Confirm the state of the lamps on the two 24DTI cards or
    30DTI cards. See Ta b l e  5 - 1 and Table 5-2.
    Table 5-1  Alarm Indications on the 24DTI Card (Loop-Back Test)
    LEDLED INDICATION FAULT
    NORMAL FAULT CAUSE ACTION
    RU N F la s h
    (120 IPM)On or Off Abnormal 
    operation of DTI 
    cardConfirm the programming data: 
    CM05, CM07 YY=01.
    Check to see if the SENS 
    switch is set as per the AP 
    number (04-15, 20-31) 
    assigned by CM05.
    Reset the MB switch 
    (Down→Up→Down)
    If the fault cannot be cleared, 
    replace the card.
    CRC Off On Bit Error Rate 
    exceeds the 
    predetermined 
    valueCheck the receive line and 
    external equipment.
    Replace the remote DTI card.
    PCM Off On No PCM signals 
    arrive from the 
    distant officeCheck to see if the DTI cable is 
    correctly connected.
    Plug and unplug the DTI card.
    Repeat this two or three times.
    FRM Off On Frame Alignment 
    signals from the 
    distant office can 
    not be receivedCheck the receive line and 
    external equipment.
    Replace the remote DTI card.
    RMT Off On Frame Alignment 
    signals cannot be 
    sent to the remote 
    PBXCheck the transmission line 
    and external equipment.
    Replace the DTI card.
    AIS Off On Remote PBX is in 
    the loop-back testCheck the switch settings of the 
    remote DTI card.1
    2
    3
    4
    1
    2
    1
    2
    1
    2
    1
    2
    1 
    						
    All NEC manuals Comments (0)