NEAX2000 IVS2 CCIS System ManualPage 298 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-2LDTA (LDT) PN-2LDTA (LDT) Locations of Lamps, Switches and Connectors Lamp Indications Switch Settings This card has no switches. LAMP NAMECOLOR FUNCTION BL0, 1 RedRemains lit when the corresponding circuit is in use. Flashes at 60 IPM when the corresponding circuit is in make- busy state or the system data for this card is not assigned. BL1 BL0
CHAPTER 4 CIRCUIT CARD INFORMATION PN-M10 (M10) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 299 PN-M10 (M10) Location of Lamps, Switches and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION CK0 Green Remains lit when a Digital Trunk Interface is connected to No. 0 circuit on this card. CK1 Green Remains lit when a Digital Trunk Interface is connected to No. 1 circuit on this card. TALM Red Remains lit when optical output is stopped. RALM Red Remains lit when optical input is lost or stopped. CN1 TO OPTICAL CABLECK0 CK1 TA L M RALM JP3 JP4 JP2 JP1 JP0
NEAX2000 IVS2 CCIS System ManualPage 300 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-M10 (M10) Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK JP0, 1 (Jumper pin) UPWhen connected to E1 (2M) Digital Trunk Interface. DOWNWhen connected to T1 (1.5M) Digital Trunk Interface. JP2 (Jumper pin) RightLine code: B8ZS* is provided (For T1 interface) *B8ZS: Bipolar Eight Zero Substitution LeftLine code: B8ZS* is not provided (For T1 interface) *B8ZS: Bipolar Eight Zero Substitution JP3 (Jumper pin) RightWhen connected to E1 (2M) Digital Trunk Interface. LeftWhen connected to T1 (1.5M) Digital Trunk Interface. JP4 (Jumper pin) UPWhen connected to E1 (2M) Digital Trunk Interface. DOWNWhen connected to T1 (1.5M) Digital Trunk Interface.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-2ODTA (ODT) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 301 PN-2ODTA (ODT) Locations of Lamps, Switches and Connectors Lamp Indications Switch Settings This card has no switches. LAMP NAMECOLOR FUNCTION BL0, 1 RedRemains lit when the corresponding circuit is in use. Flashes at 60 IPM when the corresponding circuit is in make- busy state or the system data for this card is not assigned. BL1 BL0 CN1
NEAX2000 IVS2 CCIS System ManualPage 302 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-2ODTB (ODT) PN-2ODTB (ODT) Locations of Lamps, Switches and Connectors Lamp Indications Switch Settings This card has no switches. LAMP NAMECOLOR FUNCTION BL0, 1 RedRemains lit when the corresponding circuit is in use. Flashes at 60 IPM when the corresponding circuit is in make- busy state or the system data for this card is not assigned. BL1 BL0 CN1
NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 303 CHAPTER 5 OPERATION TEST This chapter explains inter-office test procedure relating to the basic DTI functions.
NEAX2000 IVS2 CCIS System ManualPage 304 ND-70918 (E), Issue 1.0 CHAPTER 5 OPERATION TEST LOOP-BACK TEST LOOP-BACK TEST A loop-back test is performed on the DTI card. At least two DTI cards are necessary. Operational tests are performed by the clock within the MP. STEP 1: Assign the system data for a performance test as shown in Figure 5-1. Figure 5-1 Loop-Back Test DP/PB TEL DP/PB TELTDSW LC LCDTI DTILOOP BACK
CHAPTER 5 OPERATION TEST LOOP-BACK TEST NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 305 STEP 2: Connect the cable for loop-back test. (1) When using a twisted-pair cable: Figure 5-2 shows an example of the cable connection when the 24DTI/30DTI cards are mounted in the AP05 and AP06 slot of PIM0. Figure 5-2 Loop-Back Test Cable Connection (for Twisted-Pair Cable) PIM0 JPMDF 24DTI/30DTI AP05 [LT05] AA0 BA0 AA1 BA117 42 18 43T0-31 32 33 34 LTC1 PIM0 JP AP06 [LT06] AB0 BB0 AB1 BB121 46 22 47LOOP-BACK LTC1 17 42 18 43RA RB TA TB 21 46 22 47T0-39 40 41 42 24DTI/30DTI RA RB TA TB
NEAX2000 IVS2 CCIS System ManualPage 306 ND-70918 (E), Issue 1.0 CHAPTER 5 OPERATION TEST LOOP-BACK TEST (2) When using a coaxial cable: Figure 5-3 shows an example of the cable connection when the 30DTI cards are mounted in the AP07 and AP08 slot of PIM0. Figure 5-3 Loop-Back Test Cable Connection (for Coaxial Cable) PIM0 30DTI RCV TRS JPCONN CARD LTC2 AP07 [LT07] PIM0 30DTI RCV TRS JPCONN CARD LTC2 AP08 [LT08] COAXIAL CONNECTOR COAXIAL CONNECTOR LOOP- BACK AE0 BE0 AE1 BE19 34 10 359 34 10 35 AF0 BF0 AF1 BF19 34 10 359 34 10 35
CHAPTER 5 OPERATION TEST LOOP-BACK TEST NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 307 STEP 3: Turn on the operating power. Confirm the state of the lamps on the two 24DTI cards or 30DTI cards. See Ta b l e 5 - 1 and Table 5-2. Table 5-1 Alarm Indications on the 24DTI Card (Loop-Back Test) LEDLED INDICATION FAULT NORMAL FAULT CAUSE ACTION RU N F la s h (120 IPM)On or Off Abnormal operation of DTI cardConfirm the programming data: CM05, CM07 YY=01. Check to see if the SENS switch is set as per the AP number (04-15, 20-31) assigned by CM05. Reset the MB switch (Down→Up→Down) If the fault cannot be cleared, replace the card. CRC Off On Bit Error Rate exceeds the predetermined valueCheck the receive line and external equipment. Replace the remote DTI card. PCM Off On No PCM signals arrive from the distant officeCheck to see if the DTI cable is correctly connected. Plug and unplug the DTI card. Repeat this two or three times. FRM Off On Frame Alignment signals from the distant office can not be receivedCheck the receive line and external equipment. Replace the remote DTI card. RMT Off On Frame Alignment signals cannot be sent to the remote PBXCheck the transmission line and external equipment. Replace the DTI card. AIS Off On Remote PBX is in the loop-back testCheck the switch settings of the remote DTI card.1 2 3 4 1 2 1 2 1 2 1 2 1