    							 NEAX2000 IVS2 CCIS System ManualPage 248  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk to Trunk Restriction-CCIS
    Programming
    DESCRIPTION DATA
    Assign the Trunk Restriction Class to the 
    required trunk route.
    (1)
    (2)YY=97
    00-63: Route No.
    XZ
    X: 1-8 : Day Class
    Z: 1-8 : Night Class
    1: Unrestricted (RCA)
    2: Non-Restricted 1 (RCB)
    3: Non-Restricted 2 (RCC)
    4: Semi-Restricted 1 (RCE)
    5: Semi-Restricted 2 (RCE)
    6: Restricted 1 (RCF)
    7: Restricted 2 (RCG)
    8: Fully-Restricted (RCH)
    Assign the Area Code Development 
    Pattern number to the required trunk route.
    (1)
    (2)YY=76
    00-63: Trunk Route No.
    0-7: Area Code Development Pattern 
    No. 0-7START
    CM35
    A 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk to Trunk Restriction-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 249
    DESCRIPTION DATA
    Assign the Toll Restriction Patterns with 
    eight kinds of Trunk Restriction Classes 
    assigned by CM35 YY=97. Toll Restriction 
    Pattern 00-15 have already been 
    programmed as shown below. If a new 
    Restriction Pattern is required, change the 
    data for Restriction Patterns 01-13 (00, 14 
    and 15 are fixed).
    (1)
    (2)YY=01-13 
    Toll Restriction Pattern No. 01-13
    1-8: Trunk Restriction Class
    0: Restricted
    3: Allowed
    Specify the maximum number of digits 
    dialed by the calling party. The maximum 
    number of digits including the area codes 
    should be assigned to each area code.
    (1)
    (2)Y=0-7 
    Area Code Development Pattern No. 0-
    7 assigned by CM8A YYYY=A000
    X-X...X: Area Code dialed 
    (Max. 8 digits)
    01-24 : 1-24 digits
    25-79 : 25-79 digits
    CM85
    CM81
    A
    B
    0: Restricted
    3: AllowedTRUNK
    RESTRICTION
    CLASSYY
    01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00
    TOLL RESTRICTION PATTERN NUMBER ON EACH TRUNK RESTRICTION CLASS
    01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00
    1 RCA 3033300033333030
    2 RCB 3033000033000030
    3 RCC 3030000030000030
    4 RCD 3000000000000030
    5 RCE 3000000000000030
    6 RCF 0000000000000030
    7 RCG 0000000000000030
    8 RCH 0000000000000030 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 250  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk to Trunk Restriction-CCIS
    DESCRIPTION DATA
    Assign the area code to be restricted and 
    the Toll Restriction Pattern number 
    assigned by CM81 to the Area Code 
    Development Pattern number assigned by 
    CM35 YY=76. For example, to provide the 
    Trunk Restriction Class RCB, RCC, RCD, 
    RCE, RCF, RCG and RCH with the Toll 
    Restriction for Area Code “00”:
    Area Code=00
    Toll Restriction Pattern=05
    (See Toll Restriction Pattern Table on 
    CM81.)
    If the Toll Restriction Pattern for the same 
    area code is changed according to the 
    Tenant, Date, and Time, add the required 
    patterns (Tenant, Date, and Time) to the 
    area code.
    (1)
    (2)YYYY=4000-4007 
    Area Code Development No. 0-7
    X-X...X: Area Code (Max. 8 digits)
    B000-B015: Toll Restriction Pattern 
    00-15
    CM8A
    B
    C
    2000 
    -2007
    3000 
    -3003
    0000 
    -0255
    1000 
    -1015
    5000 
    -5255
    Area 
    Code4000 
    -4004Time 
    Pa t te r n
    Tenant 
    Patter n
    Route 
    Patter n
    Data 
    Pattern
    TR 
    Patter n Toll Restriction 
    Pattern 00-15 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk to Trunk Restriction-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 251
    DESCRIPTION DATA
    To add the Tenant Pattern:
    STEP 1 Assign the area code to be 
    restricted and the Tenant 
    Pattern number to the Area 
    Code Development Pattern 
    number assigned by CM35 
    YY=76.
    STEP 2  Assign the Tenant number and 
    the Route Pattern number to 
    Tenant Pattern number 
    assigned by Step 1.
    STEP 3  Assign the TR Pattern number 
    to Route Pattern number 
    assigned by Step 2.
    STEP 4  Assign the Toll Restriction 
    Pattern number assigned by 
    CM81 to TR Pattern number 
    assigned by Step 3.
    (1)
    (2)
    
    (1)
    (2)
    
    (1)
    (2)
    
    (1)
    (2)YYYY=4000-4007 
    Area Code Development Pattern No.
    X-X...X: Area Code (Max. 8 digits)
    1000-1015: Tenant Pattern No. 00-15
    YYYY=1000-1015 Tenant Pattern No. 
    00-15
    00-63: Tenant No. 00-63
    0000-0255: Route Pattern No. 000-255
    YYYY=0000-0255 
    Route Pattern No. 000-255
    1
    XXX 00 (TR Pattern No.)
    XXX: 000-255: TR Pattern No. 
    YYYY=5000-5255 TR Pattern No.
    000
    00-15 : Toll Restriction Pattern No. 0-
    15
    To add the Time and Date Pattern:
    STEP 1 Assign the area code to be 
    restricted and the Date Pattern 
    number to the Area Code 
    Development Pattern number 
    assigned by CM35 YY=76.
    STEP 2  Assign a date to applied to Toll 
    Restriction and Time Pattern 
    number 0-7 to the Date Pattern 
    number assigned by Step 1.
    Set the data for all dates, one 
    by one, to be applied Toll 
    Restriction.
    (1)
    (2)
    
    (1)
    (2)YYYY=4000-4007
    X-X...X: Area Code (Max. 8 digits)
    3000-3003: Date Pattern No. 0-3
    YYYY=3000-3003 Date Pattern No. 0-3
    0-6 (Date)
    0: Sunday
    1: Monday
    2: Tuesday
    3: Wednesday
    4: Thursday
    5: Friday
    6: Saturday
    2000-2007: Time Pattern No. 0-7
    CM8A
    C
    D 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 252  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk to Trunk Restriction-CCIS
    DESCRIPTION DATA
    STEP 3  Assign the starting time for the 
    Toll Restriction and Route 
    Pattern number to the Time 
    Pattern number assigned by 
    Step 2. Set the Starting Time as 
    shown below.
    Example:To Set the 7:00 AM to 9:00 PM 
    for the Toll Restriction, enter the 
    following starting times one by 
    one.
    0700 (7:00 AM-7:30 AM)
    0730 (7:30 AM-8:00 AM)
    0800 (8:00 AM-8:30 AM)
    2030 (8:30 AM-9:00 AM)
    (1)
    (2)YYYY=2000-2007 Time Pattern No. 
    00-07
    XX ZZ (Starting Time)
    XX: 00-23 (Hours)
    ZZ: 00/30 (Minutes)
    0000-0255
    (Route Pattern No. 000-255)
    If Tenant Pattern is required, set 1000-1015 
    (Tenant Pattern No. 00-15).
    STEP 4  Assign the TR Pattern number 
    to the Route Pattern number 
    assigned by Step 3.
    STEP 5  Assign the Toll Restriction 
    pattern number (assigned by 
    CM81) to TR Pattern number 
    assigned by Step 4.
    (1)
    (2)
    
    (1)
    (2)Y=0000-0255 
    Route Pattern No.000-255
    1
    XXX 00 (TR Pattern No.)
    XXX: 000-255: TR Pattern No. 
    Y=5000-5255 TR Pattern No. 000-255
    000
    00-15 : Toll Restriction Pattern No. 00-
    15
    END
    CM8A
    D
    ... 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk to Trunk Restriction-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 253
    When changing the initial setting (See NOTE on next page.), or when receiving the IMX Trunk
    Restriction Class (0-15), execute the following programming.
    DESCRIPTION DATA
    Assign the IMX Trunk Restriction Class to 
    each PBX Trunk Restriction Class for the 
    restriction class conversion from the PBX 
    to IMX, if required.(1)
    (2)20: TRK Restriction Class 1 (RCA)
    21: TRK Restriction Class 2 (RCB)
    22: TRK Restriction Class 3 (RCC)
    23: TRK Restriction Class 4 (RCD)
    24: TRK Restriction Class 5 (RCE)
    25: TRK Restriction Class 6 (RCF)
    26: TRK Restriction Class 7 (RCG)
    27: TRK Restriction Class 8 (RCH)
    00-15: IMX TRK Restriction Class 
    (0-15)
    Assign the PBX Trunk Restriction Class to 
    each IMX Trunk Restriction Class for the 
    restriction class conversion from IMX to 
    PBX, if required.(1)
    (2)30: TRK Restriction Class 0
    31: TRK Restriction Class 1
    32: TRK Restriction Class 2
    33: TRK Restriction Class 3
    34: TRK Restriction Class 4
    35: TRK Restriction Class 5
    36: TRK Restriction Class 6
    37: TRK Restriction Class 7
    38: TRK Restriction Class 8
    39: TRK Restriction Class 9
    40: TRK Restriction Class 10
    41: TRK Restriction Class 11
    42: TRK Restriction Class 12
    43: TRK Restriction Class 13
    44: TRK Restriction Class 14
    45: TRK Restriction Class 15
    01-08: PBX TRK Restriction Class 
    (1-8)START
    END
    CM42 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 254  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Trunk to Trunk Restriction-CCIS
    NOTE:If no data is set, the initial setting is shown below.
    (1) PBX to IMX
    (2) IMX to PBX
    Operating Procedure
    No manual operation is required.
    1S T DATA 2ND DATA
    20: TRK Restriction Class 1 (RCA)
    21: TRK Restriction Class 2 (RCB)
    22: TRK Restriction Class 3 (RCC)
    23: TRK Restriction Class 4 (RCD)
    24: TRK Restriction Class 5 (RCE)
    25: TRK Restriction Class 6 (RCF)
    26: TRK Restriction Class 7 (RCG)
    27: TRK Restriction Class 8 (RCH)01: TRK Restriction Class 1
    02: TRK Restriction Class 2
    03: TRK Restriction Class 3
    04: TRK Restriction Class 4
    05: TRK Restriction Class 5
    06: TRK Restriction Class 6
    07: TRK Restriction Class 7
    08: TRK Restriction Class 8
    1S T DATA 2ND DATA
    30: TRK Restriction Class 0
    31: TRK Restriction Class 1
    32: TRK Restriction Class 2
    33: TRK Restriction Class 3
    34: TRK Restriction Class 4
    35: TRK Restriction Class 5
    36: TRK Restriction Class 6
    37: TRK Restriction Class 7
    38-45: TRK Restriction Class 8-1501: TRK Restriction Class 1 (RCA)
    01: TRK Restriction Class 1 (RCA)
    02:  TRK Restriction Class 2 (RCB)
    03:  TRK Restriction Class 3 (RCC)
    04:  TRK Restriction Class 4 (RCD)
    05:  TRK Restriction Class 5 (RCE)
    06:  TRK Restriction Class 6 (RCF)
    07:  TRK Restriction Class 7 (RCG)
    08:  TRK Restriction Class 8 (RCH) 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Uniform Numbering Plan-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 255
    UNIFORM NUMBERING PLAN-CCIS
    General Description
    In a CCIS network, a Uniform Numbering Plan enables a station user to call any other station in
    the network. Two alternative numbering plans are provided. In the first plan, the station user dials
    any digits station number from three to eight. The location of the office is identified by the first
    one-, or two-digits of the station number. In the second plan, the station user dials a one-, two-,
    or three-digit office number and any digit station number from two to eight.
    Programming
    Refer to “Numbering Plan Assignment”.
    Operating Procedure
    To call a station at another office using Numbering Plan 1:
    (1) Lift the handset; receive dial tone.
    (2) Dial the any digit station number three to eight.
    (3) The call is routed to another office according to programmed routing information, and the 
    called station rings.
    (4) The called station answers and the par ties are connected.
    To call a station at another office using Numbering Plan 2:
    (1) Lift the handset; receive Dial Tone.
    (2) Dial the access code for CCIS.
    (3) Dial the one-, two-, or three-digit office code and any digit station number from two to eight.
    (4) The call is routed to the office designated by the Office Code. The called station rings.
    (5) The called station answers and the par ties are connected. 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 256  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Voice Call-CCIS
    VOICE CALL-CCIS
    General Description
    This feature provides a voice path, through the CCIS network, between a Dterm in one office and
    a D
    term in another office. This path is established from the calling party to the called party’s built-
    in speaker. If the called party’s “MIC” is on, the called party can converse hands-free.
    Programming
    Operating Procedure
    From a Dterm to another Dterm:
    (1) The originating D
    term user dials the desired station number in a different office and receives 
    ring back tone.
    (2) Calling party presses the VCL feature/line key. 
    A signal tone is transmitted over the CCIS network to the called party’s speaker. 
    The calling party’s LCD displays:
    (3) The called party presses “MIC” key and dials “1” (if the MIC LED is not on) to allow two-way 
    conversation with the calling party.
    DESCRIPTION DATA
    Assign a Voice Call key to the D
    term.
    (1)
    (2)YY=00
    My Line No. +   + Key No.
    F1002: Voice Call
    START
    END
    CM90,
    VCL          XXXX
    (TIME DISPLAY)
    Called Dterm
    Dterm Series III (Dterm 65) Dterm Series E (Dterm 75)
    VOICE CALL    XXXX
    (TIME DISPLAY) 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Voice Mail Integration-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 257
    VOICE MAIL INTEGRATION-CCIS
    General Description
    This feature allows any station user in the CCIS network to utilize the Voice Mail System (VMS)
    with the Message Center Interface (MCI).
    Programming
    Refer to Feature Programming Manual. 
    						
    All NEC manuals Comments (0)