NEC Neax 2000 Ivs2 Ccis System Manual
Have a look at the manual NEC Neax 2000 Ivs2 Ccis System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
NEAX2000 IVS2 CCIS System ManualPage 248 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Trunk to Trunk Restriction-CCIS Programming DESCRIPTION DATA Assign the Trunk Restriction Class to the required trunk route. (1) (2)YY=97 00-63: Route No. XZ X: 1-8 : Day Class Z: 1-8 : Night Class 1: Unrestricted (RCA) 2: Non-Restricted 1 (RCB) 3: Non-Restricted 2 (RCC) 4: Semi-Restricted 1 (RCE) 5: Semi-Restricted 2 (RCE) 6: Restricted 1 (RCF) 7: Restricted 2 (RCG) 8: Fully-Restricted (RCH) Assign the Area Code Development Pattern number to the required trunk route. (1) (2)YY=76 00-63: Trunk Route No. 0-7: Area Code Development Pattern No. 0-7START CM35 A
CHAPTER 3 SYSTEM DATA PROGRAMMING Trunk to Trunk Restriction-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 249 DESCRIPTION DATA Assign the Toll Restriction Patterns with eight kinds of Trunk Restriction Classes assigned by CM35 YY=97. Toll Restriction Pattern 00-15 have already been programmed as shown below. If a new Restriction Pattern is required, change the data for Restriction Patterns 01-13 (00, 14 and 15 are fixed). (1) (2)YY=01-13 Toll Restriction Pattern No. 01-13 1-8: Trunk Restriction Class 0: Restricted 3: Allowed Specify the maximum number of digits dialed by the calling party. The maximum number of digits including the area codes should be assigned to each area code. (1) (2)Y=0-7 Area Code Development Pattern No. 0- 7 assigned by CM8A YYYY=A000 X-X...X: Area Code dialed (Max. 8 digits) 01-24 : 1-24 digits 25-79 : 25-79 digits CM85 CM81 A B 0: Restricted 3: AllowedTRUNK RESTRICTION CLASSYY 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00 TOLL RESTRICTION PATTERN NUMBER ON EACH TRUNK RESTRICTION CLASS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00 1 RCA 3033300033333030 2 RCB 3033000033000030 3 RCC 3030000030000030 4 RCD 3000000000000030 5 RCE 3000000000000030 6 RCF 0000000000000030 7 RCG 0000000000000030 8 RCH 0000000000000030
NEAX2000 IVS2 CCIS System ManualPage 250 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Trunk to Trunk Restriction-CCIS DESCRIPTION DATA Assign the area code to be restricted and the Toll Restriction Pattern number assigned by CM81 to the Area Code Development Pattern number assigned by CM35 YY=76. For example, to provide the Trunk Restriction Class RCB, RCC, RCD, RCE, RCF, RCG and RCH with the Toll Restriction for Area Code “00”: Area Code=00 Toll Restriction Pattern=05 (See Toll Restriction Pattern Table on CM81.) If the Toll Restriction Pattern for the same area code is changed according to the Tenant, Date, and Time, add the required patterns (Tenant, Date, and Time) to the area code. (1) (2)YYYY=4000-4007 Area Code Development No. 0-7 X-X...X: Area Code (Max. 8 digits) B000-B015: Toll Restriction Pattern 00-15 CM8A B C 2000 -2007 3000 -3003 0000 -0255 1000 -1015 5000 -5255 Area Code4000 -4004Time Pa t te r n Tenant Patter n Route Patter n Data Pattern TR Patter n Toll Restriction Pattern 00-15
CHAPTER 3 SYSTEM DATA PROGRAMMING Trunk to Trunk Restriction-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 251 DESCRIPTION DATA To add the Tenant Pattern: STEP 1 Assign the area code to be restricted and the Tenant Pattern number to the Area Code Development Pattern number assigned by CM35 YY=76. STEP 2 Assign the Tenant number and the Route Pattern number to Tenant Pattern number assigned by Step 1. STEP 3 Assign the TR Pattern number to Route Pattern number assigned by Step 2. STEP 4 Assign the Toll Restriction Pattern number assigned by CM81 to TR Pattern number assigned by Step 3. (1) (2) (1) (2) (1) (2) (1) (2)YYYY=4000-4007 Area Code Development Pattern No. X-X...X: Area Code (Max. 8 digits) 1000-1015: Tenant Pattern No. 00-15 YYYY=1000-1015 Tenant Pattern No. 00-15 00-63: Tenant No. 00-63 0000-0255: Route Pattern No. 000-255 YYYY=0000-0255 Route Pattern No. 000-255 1 XXX 00 (TR Pattern No.) XXX: 000-255: TR Pattern No. YYYY=5000-5255 TR Pattern No. 000 00-15 : Toll Restriction Pattern No. 0- 15 To add the Time and Date Pattern: STEP 1 Assign the area code to be restricted and the Date Pattern number to the Area Code Development Pattern number assigned by CM35 YY=76. STEP 2 Assign a date to applied to Toll Restriction and Time Pattern number 0-7 to the Date Pattern number assigned by Step 1. Set the data for all dates, one by one, to be applied Toll Restriction. (1) (2) (1) (2)YYYY=4000-4007 X-X...X: Area Code (Max. 8 digits) 3000-3003: Date Pattern No. 0-3 YYYY=3000-3003 Date Pattern No. 0-3 0-6 (Date) 0: Sunday 1: Monday 2: Tuesday 3: Wednesday 4: Thursday 5: Friday 6: Saturday 2000-2007: Time Pattern No. 0-7 CM8A C D
NEAX2000 IVS2 CCIS System ManualPage 252 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Trunk to Trunk Restriction-CCIS DESCRIPTION DATA STEP 3 Assign the starting time for the Toll Restriction and Route Pattern number to the Time Pattern number assigned by Step 2. Set the Starting Time as shown below. Example:To Set the 7:00 AM to 9:00 PM for the Toll Restriction, enter the following starting times one by one. 0700 (7:00 AM-7:30 AM) 0730 (7:30 AM-8:00 AM) 0800 (8:00 AM-8:30 AM) 2030 (8:30 AM-9:00 AM) (1) (2)YYYY=2000-2007 Time Pattern No. 00-07 XX ZZ (Starting Time) XX: 00-23 (Hours) ZZ: 00/30 (Minutes) 0000-0255 (Route Pattern No. 000-255) If Tenant Pattern is required, set 1000-1015 (Tenant Pattern No. 00-15). STEP 4 Assign the TR Pattern number to the Route Pattern number assigned by Step 3. STEP 5 Assign the Toll Restriction pattern number (assigned by CM81) to TR Pattern number assigned by Step 4. (1) (2) (1) (2)Y=0000-0255 Route Pattern No.000-255 1 XXX 00 (TR Pattern No.) XXX: 000-255: TR Pattern No. Y=5000-5255 TR Pattern No. 000-255 000 00-15 : Toll Restriction Pattern No. 00- 15 END CM8A D ...
CHAPTER 3 SYSTEM DATA PROGRAMMING Trunk to Trunk Restriction-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 253 When changing the initial setting (See NOTE on next page.), or when receiving the IMX Trunk Restriction Class (0-15), execute the following programming. DESCRIPTION DATA Assign the IMX Trunk Restriction Class to each PBX Trunk Restriction Class for the restriction class conversion from the PBX to IMX, if required.(1) (2)20: TRK Restriction Class 1 (RCA) 21: TRK Restriction Class 2 (RCB) 22: TRK Restriction Class 3 (RCC) 23: TRK Restriction Class 4 (RCD) 24: TRK Restriction Class 5 (RCE) 25: TRK Restriction Class 6 (RCF) 26: TRK Restriction Class 7 (RCG) 27: TRK Restriction Class 8 (RCH) 00-15: IMX TRK Restriction Class (0-15) Assign the PBX Trunk Restriction Class to each IMX Trunk Restriction Class for the restriction class conversion from IMX to PBX, if required.(1) (2)30: TRK Restriction Class 0 31: TRK Restriction Class 1 32: TRK Restriction Class 2 33: TRK Restriction Class 3 34: TRK Restriction Class 4 35: TRK Restriction Class 5 36: TRK Restriction Class 6 37: TRK Restriction Class 7 38: TRK Restriction Class 8 39: TRK Restriction Class 9 40: TRK Restriction Class 10 41: TRK Restriction Class 11 42: TRK Restriction Class 12 43: TRK Restriction Class 13 44: TRK Restriction Class 14 45: TRK Restriction Class 15 01-08: PBX TRK Restriction Class (1-8)START END CM42
NEAX2000 IVS2 CCIS System ManualPage 254 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Trunk to Trunk Restriction-CCIS NOTE:If no data is set, the initial setting is shown below. (1) PBX to IMX (2) IMX to PBX Operating Procedure No manual operation is required. 1S T DATA 2ND DATA 20: TRK Restriction Class 1 (RCA) 21: TRK Restriction Class 2 (RCB) 22: TRK Restriction Class 3 (RCC) 23: TRK Restriction Class 4 (RCD) 24: TRK Restriction Class 5 (RCE) 25: TRK Restriction Class 6 (RCF) 26: TRK Restriction Class 7 (RCG) 27: TRK Restriction Class 8 (RCH)01: TRK Restriction Class 1 02: TRK Restriction Class 2 03: TRK Restriction Class 3 04: TRK Restriction Class 4 05: TRK Restriction Class 5 06: TRK Restriction Class 6 07: TRK Restriction Class 7 08: TRK Restriction Class 8 1S T DATA 2ND DATA 30: TRK Restriction Class 0 31: TRK Restriction Class 1 32: TRK Restriction Class 2 33: TRK Restriction Class 3 34: TRK Restriction Class 4 35: TRK Restriction Class 5 36: TRK Restriction Class 6 37: TRK Restriction Class 7 38-45: TRK Restriction Class 8-1501: TRK Restriction Class 1 (RCA) 01: TRK Restriction Class 1 (RCA) 02: TRK Restriction Class 2 (RCB) 03: TRK Restriction Class 3 (RCC) 04: TRK Restriction Class 4 (RCD) 05: TRK Restriction Class 5 (RCE) 06: TRK Restriction Class 6 (RCF) 07: TRK Restriction Class 7 (RCG) 08: TRK Restriction Class 8 (RCH)
CHAPTER 3 SYSTEM DATA PROGRAMMING Uniform Numbering Plan-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 255 UNIFORM NUMBERING PLAN-CCIS General Description In a CCIS network, a Uniform Numbering Plan enables a station user to call any other station in the network. Two alternative numbering plans are provided. In the first plan, the station user dials any digits station number from three to eight. The location of the office is identified by the first one-, or two-digits of the station number. In the second plan, the station user dials a one-, two-, or three-digit office number and any digit station number from two to eight. Programming Refer to “Numbering Plan Assignment”. Operating Procedure To call a station at another office using Numbering Plan 1: (1) Lift the handset; receive dial tone. (2) Dial the any digit station number three to eight. (3) The call is routed to another office according to programmed routing information, and the called station rings. (4) The called station answers and the par ties are connected. To call a station at another office using Numbering Plan 2: (1) Lift the handset; receive Dial Tone. (2) Dial the access code for CCIS. (3) Dial the one-, two-, or three-digit office code and any digit station number from two to eight. (4) The call is routed to the office designated by the Office Code. The called station rings. (5) The called station answers and the par ties are connected.
NEAX2000 IVS2 CCIS System ManualPage 256 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Voice Call-CCIS VOICE CALL-CCIS General Description This feature provides a voice path, through the CCIS network, between a Dterm in one office and a D term in another office. This path is established from the calling party to the called party’s built- in speaker. If the called party’s “MIC” is on, the called party can converse hands-free. Programming Operating Procedure From a Dterm to another Dterm: (1) The originating D term user dials the desired station number in a different office and receives ring back tone. (2) Calling party presses the VCL feature/line key. A signal tone is transmitted over the CCIS network to the called party’s speaker. The calling party’s LCD displays: (3) The called party presses “MIC” key and dials “1” (if the MIC LED is not on) to allow two-way conversation with the calling party. DESCRIPTION DATA Assign a Voice Call key to the D term. (1) (2)YY=00 My Line No. + + Key No. F1002: Voice Call START END CM90, VCL XXXX (TIME DISPLAY) Called Dterm Dterm Series III (Dterm 65) Dterm Series E (Dterm 75) VOICE CALL XXXX (TIME DISPLAY)
CHAPTER 3 SYSTEM DATA PROGRAMMING Voice Mail Integration-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 257 VOICE MAIL INTEGRATION-CCIS General Description This feature allows any station user in the CCIS network to utilize the Voice Mail System (VMS) with the Message Center Interface (MCI). Programming Refer to Feature Programming Manual.