    							 NEAX2000 IVS2 CCIS System ManualPage 98  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    No. 7 CCIS With Digital Interface
    Example of No. 7 CCIS with Digital Interface
    (1) For open numbering system
    CCH
    CIC=1
    CIC=2
    TRK000
    TRK001
    TRK002CIC=2
    RT1131xx
    CCH0
    CIC=1
    CCIS CH0RT10
    32xx
    TRK003
    TRK004
    TRK005CIC=2
    RT13
    CCH1
    CIC=1
    CCIS CH1RT12 21xx
    CCH
    CIC=1
    CIC=2
    34xx35xx OFFICE CPC: 00020
    OFFICE NO.: 825 DTI1 DTI0 OFFICE A PC: 00001
    OFFICE NO.: 820OFFICE B PC: 00010
    OFFICE NO.: 822
    CONDITIONS:
     Open Numbering (4-digit Station No.)
     Centralized Billing: Not provided
     AP No. of DTI, CCH on OFFICE A:
    EXAMPLE
    DTI0  : 04
    DTI1  : 05
    CCH0: 06
    CCH1: 07 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    No. 7 CCIS With Digital Interface
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 99
    For office A, the following programming is required:
    (1) Assign the DTI card.
    (2) Assign a trunk number to the required DTI channels.
    (3) Assign DTI card parameters.
    (These data assignments are only for 24-DTI card.)
    (4) Assign a trunk route number to the DTI trunks.
    Command Code 1st Data 2nd Data
    05 Y=0 04 09 : DTI0
    05 09 : DTI1
    05 Y=1 04 1 : Basic Highway channel
    05 1 : Basic Highway channel
    Command Code 1st Data 2nd Data
    07 YY=01 0400 D000 : TRK000
    0401 D001 : TRK001
    0402 D002 : TRK002 (Common Signaling Channel)
    0500 D003 : TRK003
    0501 D004 : TRK004
    0502 D005 : TRK005 (Common Signaling Channel)
    Command Code 1st Data 2nd Data
    AA YY=00 04 0
    05 0
    AA YY=01 04 0/1
    05 0/1
    AA YY=02 04 0/1
    05 0/1
    AA YY=03 04 7
    05 7
    Command Code 1st Data 2nd Data
    30 YY=00 000 10
    : RT10
    : RT11
    : RT12
    : RT13 001 10
    002 11
    003 12
    004 12
    005 13
    For 24 DTA-C only 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 100  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    No. 7 CCIS With Digital Interface
    (5) Assign trunk route data
    (6) Assign CCH card
    Command Code 1st Data 2nd Data
    35 YY=00 10 04
    Tie Line Route Assignment 11 04
    12 04
    13 04
    35 YY=01 10 7
    Dialing Signal Type 11 7
    12 7
    13 7
    35 YY=04 10 2
    Answer Signal 11 2
    12 2
    13 2
    35 YY=05 10 1
    Release Signal 11 1
    12 1
    13 1
    35 YY=09 10 03
    Incoming Connection Signal 11 03
    12 03
    13 03
    35 YY=19 10 0-7
    DTI Pad Pattern Assignment 2nd data varies 
    depending on the Level Diagram in the 
    network. 11 0-7
    12 0-7
    13 0-7
    35 YY=20 10 00
    Sender Start Condition 11 00
    12 00
    13 00
    35 YY=90 10 0
    No. 7 CCIS facilities assignment 11 0
    12 0
    13 0
    Command Code 1st Data 2nd Data
    05 Y=0 06 11 : CCH0
    07 11 : CCH1 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    No. 7 CCIS With Digital Interface
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 101
    (7) Assign CCIS channel number to each CCH
    (8) Provide the system with No. 7 CCIS
    (9) Assign CCIS channel number to each route
    (10) Assign a CIC number to each voice channel trunk.
    (11) Assign CCIS channel data.
    Command Code 1st Data 2nd Data
    06 YY=07 0 06 : CCIS Channel 0
    1 07 : CCIS Channel 1
    Command Code 1st Data 2nd Data
    09 53 0
    Command Code 1st Data 2nd Data
    35 YY=91 10 0
    : CCIS Channel 0
    11 0
    12 1
    : CCIS Channel 1
    13 1
    Command Code 1st Data 2nd Data
    30 YY=35 000 001 : CIC1
    001 002 : CIC2
    003 001 : CIC1
    004 002 : CIC2
    Command Code 1st Data 2nd Data
    A7 YY=00 0 002
    Common Signaling Channel Assignment
    1 005
    A7 YY=01 0 00001
    Originating Point Code Assignment
    1 00001
    A7 YY=02 0 00010
    Destination Point Code Assignment
    1 00020
    A7 YY=06 0 820
    Office Number Assignment
    1 820
    A8 00010 0 Destination Point Code to which a signaling 
    message is transferred. 00020 1 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 102  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    No. 7 CCIS With Digital Interface
    (12) Assign route access data.
    NOTE:This example shows 
    Second Dial tone will be heard only after 8 is dialed.
    8 will be added and sent to Distant PBX.
    Command Code 1st Data 2nd Data
    20 Y=0 8 A126 : Access Code=8
    8A YYYY=A000 0 4005 : Area Code Development Pattern No. 5
    8A YYYY=4005 22 0000 : Route Pattern 0000
    25 0001 : Route Pattern 0001
    8A YYYY=0000 1 00010 : Trunk Route 10 
    8A YYYY=0001 1 00012 : Trunk Route 12
    8A YYYY=5000 100 9000 : Digit Addition Pattern No. 00
    8A YYYY=9000 0 8 : Addition of digit “8”.
    85 Y=5 22 07
    Maximum number of digits dialed is 7
    25 07
    8 22 XXXX...XX
    Station numbers in Distant PBX.
    Office number of Distant PBX.
    LCR Access Code 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    No. 7 CCIS With Digital Interface
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 103
    (2) For closed numbering system
    EXAMPLE
    OFFICE A PC: 00001 
    OFFICE NO.: 21
    21xxOFFICE B PC: 00010 
    OFFICE NO.: 22
    DTI0
    TRK000
    TRK001
    TRK002
    CCH0
    DTI1
    TRK003
    TRK004
    TRK005
    CCH1CIC=1
    CIC=2
    CCIS CH0
    CIC=1
    CIC=2
    CCIS CH1RT10
    RT11
    RT12
    RT13CIC=1
    CIC=2
    CCH
    CIC=1
    CIC=2
    CCH22xx
    OFFICE C
    25xx PC: 00020 
    OFFICE NO .: 25
    CONDITIONS:
      Closed Numbering (4-digit Station number) 
      Centralized Billing: Not provided 
      AP number of DTI, CCH on OFFICE A: 
        DTI0  : 04 
        DTI1  : 05 
        CCH0: 06 
        CCH1: 07 
     
      
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 104  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    No. 7 CCIS With Digital Interface
    For office A, the following programming is required:
    (1) Assign the DTI card.
    (2) Assign a trunk number to the required DTI channels.
    (3) Assign DTI card parameters.
    (These data assignments are only for 24-DTI card.)
    (4) Assign a trunk route number to the DTI trunks.
    Command Code 1st Data 2nd Data
    05 Y=0 04 09 : DTI0
    05 09 : DTI1
    05 Y=1 04 1 : Basic Highway channel
    05 1 : Basic Highway channel
    Command Code 1st Data 2nd Data
    07 YY=01 0400 D000 : TRK000
    0401 D001 : TRK001
    0402 D002 : TRK002 (Common Signaling Channel)
    0500 D003 : TRK003
    0501 D004 : TRK004
    0502 D005 : TRK005 (Common Signaling Channel)
    Command Code 1st Data 2nd Data
    AA YY=00 04 0
    05 0
    AA YY=01 04 0/1
    05 0/1
    AA YY=02 04 0/1
    05 0/1
    AA YY=03 04 7
    05 7
    Command Code 1st Data 2nd Data
    30 YY=00 000 10
    : RT10
    001 10
    002 11 : RT11
    003 12
    : RT12
    004 12
    005 13 : RT13
    For 24 DTA-C only 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    No. 7 CCIS With Digital Interface
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 105
    (5) Assign trunk route data.
    (6) Assign CCH card.
    Command Code 1st Data 2nd Data
    35 YY=00 10 04
    Tie Line Route Assignment 11 04
    12 04
    13 04
    35 YY=01 10 7
    Dialing Signal Type 11 7
    12 7
    13 7
    35 YY=04 10 2
    Answer Signal 11 2
    12 2
    13 2
    35 YY=05 10 1
    Release Signal 11 1
    12 1
    13 1
    35 YY=09 10 03
    Incoming Connection Signal 11 03
    12 03
    13 03
    35 YY=19 10 0-7
    DTI Pad Pattern Assignment 2nd data varies 
    depending on the Level Diagram in the 
    network. 11 0-7
    12 0-7
    13 0-7
    35 YY=20 10 00
    Sender Start Condition 11 00
    12 00
    13 00
    35 YY=90 10 0
    No. 7 CCIS facilities assignment 11 0
    12 0
    13 0
    Command Code 1st Data 2nd Data
    05 Y=0 06 11 : CCH0
    07 11 : CCH1 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 106  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    No. 7 CCIS With Digital Interface
    (7) Assign CCIS channel number to each CCH.
    (8) Provide the system with No. 7 CCIS.
    (9) Assign CCIS channel number to each route.
    (10) Assign a CIC number to each voice channel trunk.
    (11) Assign CCIS channel data.
    Command Code 1st Data 2nd Data
    06 YY=07 0 06 : CCIS Channel 0
    1 07 : CCIS Channel 1
    Command Code 1st Data 2nd Data
    35 YY=09 53 0
    Command Code 1st Data 2nd Data
    35 YY=91 10 0
    : CCIS Channel 0
    11 0
    12 1
    : CCIS Channel 1
    13 1
    Command Code 1st Data 2nd Data
    30 YY=35 000 001 : CIC1
    001 002 : CIC2
    003 001 : CIC1
    004 002 : CIC2
    Command Code 1st Data 2nd Data
    A7 YY=00 0 002 Common Signaling Channel Assignment
    1 005
    A7 YY=01 0 00001 Originating Point Code Assignment
    1 00001
    A7 YY=02 0 00010 Destination Point Code Assignment
    1 00020
    A8 00010 0 Destination Point Code to which a signaling 
    message is transferred. 00020 1 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    No. 7 CCIS With Digital Interface
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 107
    (12) Assign route access data.
    NOTE:This example shows   
    No second dial tone will be heard.
    No digits will be added.
    Command Code 1st Data 2nd Data
    20 Y=0 22 A129 : Access Code=22
    20 Y=0 25 A129 : Access Code=25
    8A YYYY=A000 3 4007 : Area Code Development Pattern No. 5
    8A YYYY=4007 22 0000 : Route Pattern 000 (22XX)
    25 0001 : Route Pattern 001 (25XX)
    8A YYYY=0000 1 00010 : Route 10 access by 22XX
    8A YYYY=0001 1 00012 : Route 12 access by 25XX
    20 Y=0 21 804 : 4 digits station (for Originating Station
      No.)
    85 Y=7 22 04
    Maximum number of digits dialed is 4.
    25 04
    22 XX
    Station numbers in Office B.
    25 XX
    Station numbers in Office C. 
    						