NEAX2000 IVS2 CCIS System ManualPage 288 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-SC00 (CCH) PN-SC00 (CCH) Locations of Lamps, Switches and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. LC Green Remains lit when communications are normally ongoing with the common signalling channel data links connected. LPB Green Remains lit when a loop-back test is in progress. RS SENS RUN MB SW0 LC LPB SW1 TO M O D EM ( FOR ANALOG INTERFACE)
CHAPTER 4 CIRCUIT CARD INFORMATION PN-SC00 (CCH) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 289 Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENS (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-31) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2 UP For make-busy For normal operation SW0 (Piano Key SW) 1ON Loop-back test For normal operation 2ON Analog interface OFF Digital interface 3ONRS-232C RTS signal (to MODEM) ON NOTE 3 OFFRS-232C RTS signal (to MODEM) OFF 4ON AP No. 04-15 OFF AP No. 20-31 (Continued) F 4AP No.SW0-4: ON04 05 06 07 08 09 10 11 12 13 14 15 SW0-4: OFF20 21 22 23 24 25 26 27 28 29 30 31 SW No.456789ABCDEF ON DOWN 4 3 2 1 OFF ON OFF
NEAX2000 IVS2 CCIS System ManualPage 290 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-SC00 (CCH) The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON (UP position) before plugging/ unplugging the circuit card. NOTE 3:This setting is available when SW0-2 is set to ON (Analog Interface). NOTE 4:The following two rate-adaptation methods are available in 48 Kbps data transmission. The rate adaptation method must be set to match the rate adaptation of master office. SW1(Dip SW) 1ONCommon channel signalling data transmission speed (For Digital Interface) Common channel signalling data transmission speed (For Analog Interface) Set switches (SW1-1 - SW1-5) to OFF. OFF 2ON OFF 3ON OFF 4ON OFF 5ON OFF 6ON A-law OFFµ-law 7Always set to OFF 8Always set to OFF SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 1 23 45 67 8ON TRANSMISSION SPEEDSW 1-1SW 1-2SW 1-3SW 1-4SW 1-5 48 kbps NOTE 4ON ON OFF OFF ON 48 kbps NOTE 4ON ON ON OFF ON 56 kbps ON ON OFF ON ON 64 kbps ON ON ON ON ON OFF OFF 11 48kbps Data SW1-3: OFF 11 48kbps SW1-3: ON Data
CHAPTER 4 CIRCUIT CARD INFORMATION PZ-M537 (EXPMEM) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 291 PZ-M537 (EXPMEM) Locations of Lamps, Switches and Connectors FA C E REAR CONNR: To CONN connector on PN- CP14 (MP) or PN-AP00-B (AP00) SW CONNR
NEAX2000 IVS2 CCIS System ManualPage 292 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PZ-M537 (EXPMEM) Lamps Indications This card has no lamps. Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW (Dip SW) 1For normal operation (Memory backup ON) OFFNot used (Memory backup OFF) 2 Not used 3 Not used 4 Not used 1 23 4ON ON OFF OFF OFF
CHAPTER 4 CIRCUIT CARD INFORMATION PZ-M537 (EXPMEM) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 293 Mounting PZ-M537 Card When mounting the EXPMEM card on the AP00/MP card, do the following procedure. STEP 1: Remove three screws from the rear side of EXPMEM support. NOTE:Supports and screws are attached to the EXPMEM card. STEP 2: Connect the CONNR connector on the EXPMEM card and the CONN connector on the AP00/MP card. STEP 3: Secure the EXPMEM card to the AP00/MP card with the three screws which were removed in STEP 1. SUPPORT EXPMEM CARD EXPMEM CARD CONNR CONNECTOR WHEN MOUNTING EXPMEM CARD ON THE AP00 CARDWHEN MOUNTING EXPMEM CARD ON THE MP CARD AP00 CARD CONN CONNECTOR EXPMEM CARD CONNR CONNECTOR MP CARD CONN CONNECTOR
NEAX2000 IVS2 CCIS System ManualPage 294 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PZ-M542 (CONN) PZ-M542 (CONN) Locations of Lamps, Switches and Connectors Lamp Indications This card has no lamps. JP2 RCV21 FOR No.2 CIRCUIT LT CJP1LTTO LTC CONNECTOR ON BWB IN PIM TO CHAMP CONNECTOR (MDF) JP0 TRS21 TRS01 FOR No.0 CIRCUIT COAXIAL CONNECTOR RCV01RCV11 FOR No.1 CIRCUIT TRS11
CHAPTER 4 CIRCUIT CARD INFORMATION PZ-M542 (CONN) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 295 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK JP0For coaxial connectors (No.0 circuit) LEFTFor champ connector (LT connector) (No.0 circuit) JP1 For coaxial connectors (No.1 circuit) LEFTFor champ connector (LT connector) (No.1 circuit) JP2 For coaxial connectors (No.2 circuit) LEFTFor champ connector (LT connector) (No.2 circuit) RIGHT RIGHT RIGHT
NEAX2000 IVS2 CCIS System ManualPage 296 ND-70918 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PZ-M557 (CONN) PZ-M557 (CONN) Locations of Lamps, Switches and Connectors Lamp Indications This card has no lamps. JP2 RCV20 FOR No.2 CIRCUIT LT CJP1LTTO LTC CONNECTOR ON BWB IN PIM TO CHAMP CONNECTOR (MDF) JP0 TRS20 TRS00 FOR No.0 CIRCUIT COAXIAL CONNECTOR RCV00RCV10 FOR No.1 CIRCUIT TRS10
CHAPTER 4 CIRCUIT CARD INFORMATION PZ-M557 (CONN) NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 297 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK JP0For coaxial connectors (No.0 circuit) LEFTFor champ connector (LT connector) (No.0 circuit) JP1 For coaxial connectors (No.1 circuit) LEFTFor champ connector (LT connector) (No.1 circuit) JP2 For coaxial connectors (No.2 circuit) LEFTFor champ connector (LT connector) (No.2 circuit) RIGHT RIGHT RIGHT