    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized Billing-CCIS
    SMDR with AP00 Programming (1) 
    PROGRAMMING FOR CENTER OFFICE
    When sending billing information from local offices to SMDR of Center Office, do the following
    programming.
    When sending billing information from both Center Office and Local Office to SMDR of Center
    Office, do the following programming in addition to the basic programming of SMDR with AP00.
    For details of the SMDR with AP00, refer to the Feature Programming Manual.
    DESCRIPTION DATA
    Assign the system clock data. (1)
    (2)0: Calendar Year
    0000-9999 (Ex. 1999)
    (1)
    (2)1: Date
    MM DD WW
    MM : 01-12 (Month)
    DD : 01-31 (Date)
    WW: 00 (Sun)
    01 (Mon)
    02 (Tue)
    03 (Wed)
    04 (Thu)
    05 (Fri)
    06 (Sat)
    (1)
    (2)2: Time
    HH MM SS
    HH : 00-23 (Hour)
    MM : 00-59 (Minute)
    SS : 00-59 (Second)START
    CM02
    A 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized Billing-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 159
    DESCRIPTION DATA
    Do not provide the system with Built-in 
    SMDR on MP card.(1)
    (2)800
    1 : Not provided
    (AP00 is effective)
    Provide the system with Centralized 
    Billing-CCIS for Center Office.(1)
    (2)368
    0: Provided
    Do not provide the system with Centralized 
    Billing-CCIS for Local Office.(1)
    (2)378
    1 : Not provided
    Assign the second data to 1 (Distant end is 
    a Local Office) to each CCIS channel.
    (1)
    (2)YY=03
    0-7: CCIS channel No.
    1: Distant end is Local Office
    Invalidate the data for sending of billing 
    information on tandem calls through CCIS.(1)
    (2)76
    1: Sent
    Specify the direction for sending of billing 
    information from the Local Office.(1)
    (2)239
    1: SMDR terminal set to “4” by 
    CMD001>80/100/120/140
    2: SMDR terminal set to “5” by 
    CMD001>80/100/120/140
    CM08
    A
    B
    CMA7
    CMD000
    CMD001
    INITIAL 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 160  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized Billing-CCIS
    DESCRIPTION DATA
    Assign the attribute data, depending on 
    the port (Port 0-3) connected to the SMDR 
    terminal. (For the details of commands, 
    refer to the Command Manual.)(1)
    (2)See the following table.
    See the following table.
    NOTE:For the Port 1 and Port 3, data speed 9600 bps cannot be set.
    Assign the Charging Station Class number 
    to each station number.(1)
    (2)X-XXXX: Station No.
    00-15: Station Class No.
    CMD001
    B
    C
    CMD015
    AP00 INITIAL
    FIRST DATA (1)
    MEANINGSECOND
    DATA
    (2)MEANING
    PORT
    0PORT
    1PORT
    2PORT
    3
    20 24 28 32 Data Speed 2/3/4/5 1200/2400/4800/9600 bps 
    NOTE
    21 25 29 33 Stop Bit Length 0/1/2 1 bit/1.5 bits/2 bits
    22 26 30 34 Data Length 0/1 7 bits/8 bits
    23 27 31 35 Parity 0/1/2 None Parity/Even Parity/Odd 
    Pa r i ty
    80 100 120 140 Equipment Type 4/5 Computer 0/Computer 1
    81 101 121 141 Priority for Data Processing 0 1st
    82 102 122 142 Message Format 3 NEAX2400 IMS Format
    84 104 124 144 Protocol 1 Free Wheel
    85 105 125 145 Station Address (SA) 48 0
    86 106 126 146 Unit Address (UA) 33 ! 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized Billing-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 161
    DESCRIPTIONDATA
    Invalidate the data setting of Centralized 
    Billing used for Local Office.(1)
    (2)XX31: Sending of billing information of 
    C.O. outgoing calls through 
    CCIS
    XX : 00-15 (Station Class No. 
    assigned by CMD015)
    1 : Sent
    (1)
    (2)XX32: Sending of billing information of 
    Tie Line outgoing calls through 
    CCIS
    XX : 00-15 (Station Class No. 
    assigned by CMD015)
    1 : Sent
    (1)
    (2)XX58: Sending of billing information of 
    C.O./Tie Line incoming calls 
    through CCIS
    XX : 00-15 (Station Class No. 
    assigned by CMD015)
    1 : Sent
    END
    CMD016
    C 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 162  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized Billing-CCIS
    Built-in SMDR Programming
    For Local Office or Tandem Office, in addition to the basic programming of Built-in SMDR, do the
    following programming. For details of the Built-in SMDR, refer to Feature Programming Manual.
    NOTE 1:When the system provides an AP00 card (CM05 Y=0 second data=04 is assigned), the
    Built-in SMDR cannot be provided.
    NOTE 2:Outgoing and tandem call records are not available with Built-in SMDR.
    DESCRIPTION DATA
    Provide the system with Built-in SMDR of 
    MP card.
    NOTE:Do not assign CM40 YY=00>14 
    when using Built-in SMDR in 
    Local Office of Centralized 
    Billing-CCIS.(1)
    (2)800
    0: Built-in SMDR of MP card
    Not provide the system with Centralized 
    Billing-CCIS for Center Office.(1)
    (2)368
    1 : Provided
    Provide the system with Centralized 
    Billing-CCIS for Local Office.(1)
    (2)378
    0: Provided
    Specify whether the Office number is sent 
    to Center Office for Centralized Billing-
    CCIS.
    NOTE:When the network adopts Open 
    Numbering Plan, set the office 
    number by CMA7 YY=06.(1)
    (2)801
    0 : To send
    1 : Not sentSTART
    CM08
    A
    INITIAL 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized Billing-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 163
    DESCRIPTIONDATA
    Assign the data as follows.
    1st Data 2nd Data
    CCIS channel No.  0
    (0-7) for 
    Center Office
    See Example 3: Data Assignment of 
    CMA7 YY=03, 04 on Page 176.
    (1)
    (2)YY=03
    0-7: CCIS channel No.
    0 : Distant end is Center Office
    1 : Distant end is Local Office
    Assign Centralized Billing destination.
    See Example 3: Data Assignment of 
    CMA7 YY=03, 04 on Page 176.
    (1)
    (2)YY=04
    0-7: CCIS channel No.
    00001-16367: Point Code of Center 
    Office.
    Assign Originating Office number for Open 
    Numbering Plan.
    See Example 4: Data Assignment of 
    CMA7 YY=06 and CMD004>55 on Page 
    177.
    (1)
    (2)YY=06
    0-7: CCIS channel No.
    0000-9999: Originating Office No.
    END
    CMA7
    A 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 164  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized Billing-CCIS
    SMDR with AP00 Programming (2)
    For Local Office or Tandem Office, in addition to the basic programming of SMDR with AP00, do
    the following programming. For details of the SMDR with AP00, refer to Feature Programming
    Manual.
    DESCRIPTION DATA
    Not provide the system with Built-in SMDR 
    of MP card.
    NOTE:Do not assign CM40 YY=00>14 
    when using Built-in SMDR in 
    Local Office of Centralized 
    Billing-CCIS.(1)
    (2)800
    1 : Not provided
    (AP00 is effective)
    Not provide the system with Centralized 
    Billing-CCIS for Center Office.(1)
    (2)368
    1 : Not provided
    Provide the system with Centralized 
    Billing-CCIS for Local Office.(1)
    (2)378
    0: Provided
    Specify whether the calling party 
    information (Trunk Route No./Station No.) 
    is sent to SMDR on CCIS tandem calls.
    See Example 2: Data Assignment of 
    SMDR Call Record on a Tandem Call 
    through CCIS on Page 174.(1)
    (2)377
    0 : Station No. and Office No.
    1 : Trunk Route No.START
    CM08
    A
    INITIAL 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized Billing-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 165
    DESCRIPTIONDATA
    Assign the data as follows.
    For Local Office:
    1st Data 2nd Data
    CCIS channel No.  0
    (0-7) for 
    Center Office
    For Tandem Office:
    1st Data 2nd Data
    CCIS channel No. 0
    (0-7) for 
    Center Office
    CCIS channel No. 1
    (0-7) for
    Local Office
    See Example 3: Data Assignment of 
    CMA7 YY=03, 04 on Page 176.
    (1)
    (2)YY=03
    0-7: CCIS channel No.
    0 : Distant end is Center Office
    1 : Distant end is Local Office
    Assign Centralized Billing destination.
    (1)
    (2)YY=04
    0-7: CCIS channel No.
    00001-16367: Point Code of Center 
    Office.
    See Example 3: Data Assignment of 
    CMA7 YY=03, 04 on Page 176.
    Specify the station number sent to the IMX 
    PBX through CCIS for SMDR.
    NOTE:If the Center Office is the IMX 
    PBX, CM65 YY=26 is required.
    (1)
    (2)YY=26
    Tenant No. of Stations
    0 : My Line No.
    1 : Sub Line No.
    CM65
    CMA7
    A
    B 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 166  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized Billing-CCIS
    DESCRIPTION DATA
    Assign a Station Class number to the 
    required station number.(1)
    (2)X-XXXX: Station No.
    00 -15: Station Class No.
    Assign the data for sending the detail call 
    information for C.O. outgoing calls through 
    CCIS.(1)
    (2)XX31
    XX: 00-15 (Station Class No. assigned 
    by CMD015)
    1: To send
    Assign the data for sending of detail call 
    information for Tie Line outgoing calls 
    through CCIS, if required.(1)
    (2)XX32
    XX: 00-15 (Station Class No. assigned 
    by CMD015)
    1: To send
    Assign the data for sending of detail call 
    information for C.O./Tie Line incoming 
    calls through CCIS, if required.(1)
    (2)XX58
    XX: 00-15 (Station Class No. assigned 
    by CMD015)
    1: To send
    Assign the Local Office number for Open 
    Numbering Plan.
    See Example 4: Data Assignment of 
    CMA7 YY=06 and CMD004>55 on Page 
    177.(1)
    (2)55
    X-XXXX: Local Office No. NOTE
    Assign the office number to specify the bill-
    ing office when originating a call of other 
    local office through the own office.
    NOTE:If using a leading degit(s) of 0 
    and 0 is required to print at the 
    SMDR terminal, assign “A” for 
    each leading 0 to be printed.
    If the leading degit(s) 0 is not 
    required to print at the SMDR 
    terminal, assign “0”.
    See Example 5: Data Assignment of 
    CMD004>56 on Page 178.(1)
    (2)56
    X-XXXX: Billing Office No. NOTE
    CMD016
    END
    CMD015
    B
    CMD004 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Centralized Billing-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 167
    Example 1: Data Assignment of SMDR output for Center Office
    In a Centralized Billing Office, the following four patterns of SMDR output can be selected.
    (1) To SMDR 0: Sending of billing information from both a Center Office and Local Offices.
    (2) To SMDR 1: Sending of billing information from both a Center Office and Local Offices.
    (3) To SMDR 0: Sending of billing information from Local Offices.
    To SMDR 1: Sending of billing information of a Center Office.
    (4) To SMDR 0: Sending of billing information of a Center Office.
    To SMDR 1: Sending of billing information from Local Offices.
    Data assignment of each pattern for Center Office
    PAT T E R N T O F R O MCMD001>
    80/100/120/140CMD
    001>239CMD016
    XX16,
    XX21,
    XX30XX17,
    XX22,
    XX55
    1 SMDR 0 Center Office C 
    and Local Office A/
    B4110
    2 SMDR 1 Center Office C 
    and Local Office A/
    B5201
    3 SMDR 0 Local Office A/B 4 1
    SMDR 1 Center Office C 501
    4 SMDR 0 Center Office C 4
    10
    SMDR 1 Local Office A/B 5 2
    Local Office
    OFFICE 
    ACenter Office
    OFFICE 
    C
    Local Office
    OFFICE 
    BSMDR 0
    SMDR 1 
    						
    All NEC manuals Comments (0)