    							 NEAX2000 IVS2 CCIS System ManualPage 128  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Call Forwarding-All Calls-CCIS
    Operating Procedure
    Single Line Telephone
    To set Call Forwarding-All Calls-CCIS from a Single Line Telephone:
    (1) Lift the handset; receive dial tone.
    (2) Dial the Call Forwarding-All Calls-CCIS access code; receive feature dial tone.
    (3) Dial the outgoing trunk access code; receive a single burst of service set tone.
    (4) Dial the station number to which calls are to be forwarded.
    (5) Wait approximately 5 seconds; receive service set tone.
    To cancel Call Forwarding-All Calls-CCIS from a Single Line Telephone:
    (1) Lift the handset; receive dial tone.
    (2) Dial Call Forwarding-All Calls-CCIS cancellation code; receive service set tone.
    Attendant Console
    To set Call Forwarding-All Calls-CCIS from an Attendant Console:
    (1) Press an idle LOOP key.
    (2) Dial Call Forwarding-All Calls-CCIS access code; receive feature dial tone.
    (3) Dial the origination station number.
    (4) Dial the outgoing trunk access code; receive a single burst feature dial tone.
    (5) Dial the station number to which calls are to be forwarded.
    (6) Press the RELEASE key.
    To cancel Call Forwarding-All Calls-CCIS from an Attendant Console:
    (1) Press an idle LOOP key.
    (2) Dial the Call Forwarding-All Calls-CCIS cancellation code; receive feature dial tone.
    (3) Dial origination station number; receive service set tone.
    (4) Press the RELEASE key.
    NOTE:The Attendant Console can set/cancel Call Forwarding-All Calls for stations within the
    local system in which the Attendant Console resides. 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Call Forwarding-All Calls-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 129
    Dterm
    To set Call Forwarding-All Calls-CCIS from a My Line:
    (1) Lift handset or press SPEAKER key; receive dial tone.
    (2) Press the Call Forwarding-All Calls-CCIS feature access key; receive feature dial tone.
    (3) Dial the outgoing trunk access code; receive a single burst of service set tone.
    (4) Dial the desired station number to which calls are to be forwarded.
    (5) Wait approximately 5 seconds; receive service set tone. The LED lights and the LCD 
    displays:
    (6) Replace the handset or press the SPEAKER key.
    To cancel Call Forwarding-All Calls-CCIS from a D
    term:
    (1) Lift handset or press SPEAKER key; receive dial tone.
    (2) Press the Call Forwarding-All Calls-CCIS feature access key. The LCD displays:
    (3) Dial “”; receive Service Set Tone. The LED of the associated feature key will go out. The 
    LCD displays:
    (4) Replace the handset or press the SPEAKER key.
    SET            XXXX
    (TIME DISPLAY)
    Forwarding station number D
    term 65 Series Dterm 75 Series
    SET            XXXX
    (TIME DISPLAY)
    FDA            YYY
    (TIME DISPLAY)
    Dterm 65 Series Dterm 75 Series
    CF ALL            YYY
    (TIME DISPLAY)
    CNCL
    (TIME DISPLAY)
    Dterm 65 Series Dterm 75 Series
    CANCEL
    (TIME DISPLAY) 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 130  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Call Forwarding-Busy Line-CCIS
    CALL FORWARDING-BUSY LINE-CCIS
    General Description
    This service feature provides inter-office Call Forwarding-Busy Line-CCIS, which permits a call
    to a busy station to be immediately forwarded to a predesignated station or to an Attendant
    Console in another office in the CCIS network.
    Programming
    DESCRIPTION DATA
    Assign Service Restriction Class A to the 
    required stations. 
    (1)
    (2)YY=02
    X-XXXXXXXX: Station No.
    XX ZZ
    XX: 00-15 : Service Restriction 
    Class A
    Allow Call Forwarding-Busy Line and Call 
    Forwarding-Busy Line-Outside in the 
    Service Restriction Class A assigned by 
    CM12 YY=02.
    NOTE:When providing Call Forwarding-
    Busy Line-Outside, set “1” (Al-
    low) for YY=11, YY=28, YY=12, 
    YY=29 of CM15.
    
    
    
    (1)
    (2)YY=11 Call Forwarding-Busy Line
    YY=28 
    Call Forwarding-Busy Line-Outside
    YY=12 
    Call Forwarding-Busy Line-Outside
    YY=29 
    Call Forwarding-Busy Line-Outside/
    Don’t Answer-Outside
    00-15: Service Restriction Class A 
    assigned by CM12 YY=02
    1 : Allow
    Assign an access code for Call Forward-
    ing-Busy Line.
    (1)
    (2)Y=0-3 Numbering Plan Group 0-3
    X-XXXX: Access Code
    A014: Call Forwarding-Busy Line Entry
    A015: Call Forwarding-Busy Line 
    Cancel
    To apply this feature to incoming calls, as-
    sign trunk route combinations for Tandem 
    connection.
    (1)
    (2)YY=05
    00-63: Trunk Route No.
    1 : Release Signal arrive
    
    (1)
    (2)Y=0
    Incoming Trunk Route No. + Outgoing 
    Trunk Route No. for CCIS (Assigned by 
    CM35 YY=05)
    0: Allow
    CM15
    CM20 START
    CM12
    CM35
    CM36
    A 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Call Forwarding-Busy Line-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 131
    DESCRIPTION DATA
    Specify the Call Forwarding-Busy Line-
    Outside setting operation.(1)
    (2)222
    0 : The feature is set when the station 
    goes on hook/when receiving Ser-
    vice Set Tone (ORT time out)
    1 : The feature is set when receiving 
    Service Set Tone (ORT time out)
    Allow or restrict the ability to set Call For-
    warding-Busy Line for a station with Do 
    Not Disturb set.(1)
    (2)240
    0 : Allow
    1: Restrict
    Assign whether or not an extension can 
    set Call Forwarding-Busy Line-Outside by 
    entering only a trunk access code.(1)
    (2)386
    0: Restrict
    1 : Allow
    Assign whether or not the system should 
    check the trunk restriction class of the 
    forwarded station during a Call 
    Forwarding-Busy Line-Outside.(1)
    (2)387
    0 : Follow trunk restriction
    1 : No check
    Provide Call Forwarding feature with each 
    tenant as per incoming call type.
    
    
    (1)
    (2)YY=23
    Internal Call or ATT assisted call
    YY=24 C.O. Incoming Call
    YY=25 Tie Line Incoming Call
    00-63: Tenant No. 
    1 : Call Forwarding
    Assign a Call Forwarding-Busy Line key to 
    the D
    term, if desired.
    (1)
    (2)YY=00
    My Line No. +   + Key No.
    F0014: Call Forwarding-Busy Line Set/
    Cancel
    END
    CM08
    A
    CM90
    CM65
    , 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 132  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Call Forwarding-Busy Line-CCIS
    When a call is forwarded through CCIS by Call Forwarding-All Calls/-Busy Line/-Don’t Answer,
    the kind of Call Forwarding and the station number which is setting the service can be indicated
    on the LCD of the forwarding destination D
    term.
    To provide this feature, perform the following programming.
    On the Forwarding side PBX (PBX-A)
    On the Forwarded destination side PBX (PBX-B)
    DESCRIPTION DATA
    Provide the system with sending of Call 
    Forwarding station information through 
    CCIS.(1)
    (2)373
    0: To provide
    DESCRIPTION DATA
    Assign Service Restriction Class A to the 
    required stations.
    (1)
    (2)YY=02
    X-XXXXXXXX: Station No. 
    XX ZZ
    XX: 00-15 : Service Restriction 
    Class A
    Specify the LCD digits number of the D
    term 
    as 24 digits.
    (1)
    (2)YY=95
    00-15: Service Restriction Class A 
    assigned by CM12 YY=02
    0: 24 digits
    PBX-APBX-B
    STATION
    /TRUNKCCIS
    STATION 2000Kind of Call Forwarding
    Call Forwarding-All Calls/
    Busy Line/Don’t Answer. Call is forwarded from
    Station 2000 byand station number “2000”
    are indicated on LCD.
    START
    END
    CM08
    START
    END
    CM12
    CM15 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Call Forwarding-Busy Line-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 133
    Operating Procedure
    Single Line Telephone
    To set Call Forwarding-Busy Line-CCIS from a Single Line Telephone:
    (1) Lift the handset; receive dial tone.
    (2) Dial the specific Call Forwarding-Busy Line-CCIS access code; receive feature dial tone.
    (3) Dial the outgoing trunk access code; receive a single burst of service set tone.
    (4) Dial the station number to which calls are to be forwarded.
    (5) Wait approximately 5 seconds; receive service set tone.
    To cancel Call Forwarding-Busy Line-CCIS from a Single Line Telephone:
    (1) Lift the handset; receive dial tone.
    (2) Dial the specific Call Forwarding-Busy Line-CCIS cancellation code; receive service set 
    tone.
    Attendant Console
    To set Call Forwarding-Busy Line-CCIS from the Attendant Console:
    (1) Press an idle LOOP key.
    (2) Dial the specific Call Forwarding-Busy Line-CCIS access code; receive dial tone. 
    (3) Dial the origination station number.
    (4) Dial the outgoing trunk access code; receive a single burst service set tone.
    (5) Dial the station number to which calls are to be forwarded.
    (6) Press the RELEASE key.
    To cancel Call Forwarding-Busy Line-CCIS from the Attendant Console:
    (1) Press an idle LOOP key.
    (2) Dial the specific Call Forwarding-Busy Line-CCIS cancellation code; receive feature dial 
    tone.
    (3) Dial the origination station number; receive service set tone.
    NOTE:The Attendant Console can only set/cancel Call Forwarding-Busy Line for stations within
    the local system in which the Attendant Console resides. 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 134  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Call Forwarding-Busy Line-CCIS
    Dterm
    To set Call Forwarding-Busy Line-CCIS from a Dterm:
    (1) Lift handset or press SPEAKER key; receive dial tone.
    (2) Press the Call Forwarding-Busy Line-CCIS feature access key; receive feature dial tone.
    (3) Dial the outgoing trunk access code; receive a single burst service set tone.
    (4) Dial the station number to which calls are to be forwarded.
    (5) Wait approximately 5 seconds; receive service set tone. The LED lights and the LCD 
    displays:
    (6) Replace the handset or press the SPEAKER key.
    To cancel Call Forwarding-Busy Line-CCIS from a D
    term:
    (1) Lift handset or press SPEAKER key; receive dial tone.
    (2) Press the Call Forwarding-Busy Line key. The LCD displays:
    (3) Dial “”; receive service set tone. The LED of the associated feature key will go out. The 
    LCD displays:
    (4) Replace the handset or press the SPEAKER key.
    SET            XXXX
    (TIME DISPLAY)
    Forwarding station number D
    term 65 Series Dterm 75 Series
    SET            XXXX
    (TIME DISPLAY)
    FDB            YYY
    (TIME DISPLAY)
    Dterm 65 Series Dterm 75 Series
    CF BUSY            YYY
    (TIME DISPLAY)
    CNCL
    (TIME DISPLAY)
    Dterm 65 Series Dterm 75 Series
    CANCEL
    (TIME DISPLAY) 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Call Forwarding-Don’t Answer-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 135
    CALL FORWARDING-DON’T ANSWER-CCIS
    General Description
    This service feature provides interoffice Call Forwarding-Don’t Answer-CCIS, which permits a
    call to an unanswered station to be forwarded to a pre-designated station or to an Attendant
    Console in another office, when the called station does not answer after a predetermined time
    interval.
    Programming
    DESCRIPTION DATA
    Assign Service Restriction Class A to the 
    required stations.
    (1)
    (2)YY=02
    X-XXXXXXXX: Station No.
    XX ZZ
    XX: 00-15 : Service Restriction 
    Class A
    Allow Call Forwarding-Don’t Answer and 
    Call Forwarding-Don’t Answer-Outside in 
    the Service Restriction Class A assigned 
    by CM12 YY=02.
    NOTE:When providing Call Forwarding-
    Don’t Answer-Outside, set “1” 
    (Allow) for YY=10, YY=27 of 
    CM15.
    
    
    
    (1)
    (2)YY=10 Call Forwarding-Don’t Answer
    YY=27 
    Call Forwarding-Don’t Answer-Outside
    YY=12
    Call Forwarding-Busy Line-Outside
    YY=29
    Call Forwarding-Busy Line-Outside/
    Don’t Answer-Outside
    00-15: Service Restriction Class A 
    assigned by CM12 YY=02
    1 : Allow
    Assign an access code for Call Forward-
    ing-All Calls Entry and Cancellation re-
    spectively.
    (1)
    (2)
    (2)Y=0-3 Numbering Plan Group 0-3
    X-XXXX: Access Code
    A016 : Call Forwarding-Don’t Answer 
    Entry
    A017 : Call Forwarding-Don’t Answer 
    Cancel
    For setting the same access code as 
    Call Forwarding-Busy Line:
    A012: Entry
    A013: Cancel
    CM15
    CM20 START
    CM12
    A 
    						
    							 NEAX2000 IVS2 CCIS System ManualPage 136  ND-70918 (E), Issue 1.0
    CHAPTER 3 SYSTEM DATA PROGRAMMING
    Call Forwarding-Don’t Answer-CCIS
    DESCRIPTION DATA
    To apply this feature to incoming calls, set 
    the trunk route combinations for Tandem 
    connection.
    (1)
    (2)YY=05
    00-63: Trunk Route No.
    1 : Release Signal arrive
    Specify the combination of Trunk Routes 
    allowing a Trunk to Trunk (CCIS) 
    Connection.
    (1)
    (2)Y=0
    XX ZZ
    XX: 00-63 (Incoming Trunk Route)
    ZZ: 00-63 (Outgoing Trunk Route)
    0: Allow
    Specify the Call Forwarding-Don’t Answer-
    Outside setting operation.(1)
    (2)222
    0 : The feature is set when the station 
    goes on hook/when receiving Ser-
    vice Set Tone (ORT time out)
    1 : The feature is set when receiving 
    Service Set Tone (ORT time out)
    DID call to station with Call Forwarding-
    Don’t Answer set over CCIS to a busy 
    destination station. (Destination station 
    has no call forwarding set.)(1)
    (2)449
    0 : Ring continuously at forwarded DID 
    station
    1 : Drop to busy signal after timer set 
    by CM41 Y=0>01
    Assign whether or not an extension can 
    set Call Forwarding-Don’t Answer-Outside 
    by entering only a trunk access code.(1)
    (2)386
    0: Restrict
    1 : Allow
    Assign whether or not the system should 
    check the trunk restriction class of the 
    forwarded station during a Call 
    Forwarding-Don’t Answer-Outside.(1)
    (2)387
    0 : Follow trunk restriction
    1 : No check
    Provide Call Forwarding feature with each 
    tenant as per incoming call type.
    
    
    (1)
    (2)YY=23
    Inter Call or ATT assisted call
    YY=24 C.O. Incoming Call
    YY=25 Tie Line Incoming Call
    00-63: Tenant No.
    1 : Call Forwarding
    CM35
    A
    CM36
    B
    CM08
    CM65 
    						
    							CHAPTER 3 SYSTEM DATA PROGRAMMING
    Call Forwarding-Don’t Answer-CCIS
    NEAX2000 IVS2 CCIS System Manual    
    ND-70918 (E), Issue 1.0   Page 137
    DESCRIPTION DATA
    Specify the timing for Call Forwarding-
    Don’t Answer for a trunk incoming call.
    (1)
    (2)Y=0
    01
    01-30: 0-120 sec. (4 sec. increments)
    If no data is set, the default setting is 32-36 
    seconds.
    Specify the timing for Call Forwarding-
    Don’t Answer for an internal call or an 
    assigned call.
    (1)
    (2)Y=0
    15
    01-30: 4-120 sec. (4 sec. increments)
    If no data is set, the default setting is 32-36 
    seconds.
    Assign Call Forwarding-Don’t Answer Key 
    to the D
    term, if desired.
    (1)
    (2)YY=00
    My Line No. +   + Key No.
    F0016: Call Forwarding-Don’t Answer 
    Set/Cancel
    For setting the same key as Call 
    Forwarding-Busy Line
    (2) F10012: Set/Cancel
    CM41
    B
    END
    CM90
    , 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Ccis System Manual