Home > Mitel > Communications System > Mitel Sx 200 Ml Pabx Lightware 16 Instructions Guide

Mitel Sx 200 Ml Pabx Lightware 16 Instructions Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Mitel Sx 200 Ml Pabx Lightware 16 Instructions Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 626
    							Appendix A - Programming Error Messages 
    Table A-l Programming Error Messages (continued) 
    Error Message Meaning 
    Attempting update/delete of a device that is The selected device is being used; modify this device 
    currently in use at a later time. 
    Automated Attendant hunt group may not An auto attendant hunt group can only contain industry 
    contain SUPERSETs standard telephones. 
    Bay/Slot/Circuit XX/XX/XX is already The specified bay/slot/circuit is assigned elsewhere. 
    assigned Select a new bay/slot/circuit number or change the 
    assignment of that bay/slot/circuit number. Refer to 
    Form 01, System Configuration and Form 09, Stations/ 
    SlJPERSETTelephones. 
    Bay/Slot/Circuit XX/XX/XX is already The specified bay/slot/circuit is assigned elsewhere. 
    programmed elsewhere Select a new bay/slot/circuit number or change the 
    assignment of that bay/slot/circuit number. Refer to 
    Form 07, Console Assignment, Form 09, 
    Stations/SUPERSETTelephones and Form 12, Data 
    Assignment. 
    Bay/Slot/Circuit - XX/XX/XX cannot be Devices are assigned to the selected bay/slot/circuit. 
    programmed These devices must be deleted before a new card type 
    can be programmed for the bay/slot/circuit. 
    Bay/Slot/Circuit - XX/XX/XX is not present The specified circuit number is not applicable for these 
    bay and slot numbers. Re-enter the bay and slot 
    numbers without the circuit number or enter 0 for the 
    circuit number. 
    Bay/Slot/Circuit - XX/XX/XX is not 
    programmed as a console 
    Bay/Slot/Circuit - XX/XX/XX is not 
    programmed as a DIAL-IN trunk 
    Bay/Slot/Circuit - XX/XX/XX is not 
    programmed as a DMP DEVICE 
    Bay/Slot/Circuit - XX/XX/XX is not 
    programmed as a DNIC 
    Bay/Slot/Circuit - XX/XX/XX is not 
    programmed as a MUSIC/PAGER 
    MODULE The selected bay/slot/circuit is not a console. Refer to 
    Form 01, System Configuration and reprogram this 
    bay/slot/circuit as a console. 
    The selected bay/slot/circuit is programmed as a 
    Non-Dial-In Trunk. Refer to Form 14, Dial-In Trunks. 
    The selected device is not a Music-on-Hold/Paging Unit. 
    The selected bay/slot/circuit is not a DNIC circuit. 
    The selected bay/sloticircuit is not a music/pager 
    assignment. Refer to Form 01, System Configuration 
    and reprogram this bay/slot/circuit as a Music/Pager 
    Module. 
    Bay/Slot/Circuit - XX/XX/XX is not The selected bay/slot/circuit is programmed as a dial-in 
    programmed as a NON-DIAL-IN trunk Trunk. Refer to Form 15, Dial-In Trunks. 
    Bay/Slot/Circuit - XX/XX/XX is not Relays (Subcircuits 5 and 6) are located on the 
    programmed as a RECEIVER MODULE Receiver/Relay Module only. Ensure that there is a 
    Receiver/Relay Module on a Universal Card at that 
    location in Form 01, System Configuration. 
    Bay/Slot/Circuit - XX/XX/XX has The user attempted to range program over different card 
    incompatible device type programmed. types, a circuit that has a BLF programmed or a circuit 
    that has a SUB (enhanced subattendant) programmed. 
    Page5of 16 
    March 1997 Issue 1 Revision 0 A-5  
    						
    							Customer Data Entry 
    Table A-l Programming Error Messages (continued) 
    Error Message Meaning 
    Bay/Slot/Circuit - XX/XX/XX is not The selected trunk number corresponds to a 
    programmed as a trunk bay/slot/circuit that is not programmed as a trunk. 
    Bay/Slot/Circuit - XX/XX/XX is not The selected bay/slot/circuit is not a Universal Card 
    programmed as a UNIVERSAL CARD assignment. Refer to Form 01, System Configuration 
    and reprogram this bay/slot/circuit as a Universal Card. 
    Cannot change tenant grp, if a member of The user attempted to change the tenant of a modem 
    Modem Pool Hunt Group which was a member of a modem pool hunt group. 
    Cannot delete last agent while callers are The user attempted to delete the last agent from ACD 
    waiting on ACD Group XX group XX, which would delete group XX itself. However, 
    there are ACD calls waiting for this group, so the deletion 
    cannot be permitted at this time. 
    Cannot disable option when Automated The user attempted to disable System Option 16 - 
    Attendant programming is present Automated Attendant when there are auto attendant 
    groups programmed in the system. 
    Cannot enable DTRX due to invalid mode The user attempted to enable the DTRX option in the 
    or DTE not assigned hunt group options form for a modem hunt group for 
    which DTRX does not apply. The group has to be in 
    ANSWER or BOTH mode. 
    Cannot modify LEADING DIGITS until digit In Form 26, ARS: Digit Strings, the digit entries in the 
    strings deleted DIGITS TO BE ANALYZED field must be deleted before 
    the digit entries in the LEADING DIGITS field can be 
    modified. 
    Cannot update music/pager assignment - To modify the selected music/pager assignment, it must 
    must delete and re-enter first be deleted and then re-entered. 
    Can only use “X” wildcard at end of strings The X softkey can only be pressed at the end of a digit 
    string entry. Refer to Form 26, ARS: Digit Strings. 
    Circuit descriptor type must match The selected trunk circuit descriptor type in Form 13, 
    programmed trunk hardware type Trunk Circuit Descriptors must match the specified 
    Trunk Card type in Form 01, System Configuration. 
    Configuration cannot be changed for the In Form 01, System Configuration, the data in the 
    Bay/Slot/Circuit - XX/XX/XX PROGRAMMED field cannot be matched to the data in 
    the INSTALLED field as devices are already assigned 
    to that physical location. Cannot change the 
    configuration until the devices are de-assigned. 
    Console has LDN assigned -cannot delete An attendant console can only be deleted from the 
    system if all of its LDN assignments are removed first. 
    Refer to Form 08, Console LDN Assignments. 
    Consoles that share an LDN access code Attendant consoles that share the same LDN access 
    must be in the same TENANT GROUP code must also share the same tenant group. Refer to 
    Form 07, Console Assignments. 
    COR group out of range. Valid range is There are a maximum of 50 COR groups. 
    (1 - 50) 
    Page6of lc 
    A-6 Issue 1 Revision 0 March 1997  
    						
    							Appendix A - Programming Error Messages 
    Table A-l Programming Error Messages (continued) 
    Error Message 
    COR value is out of range 
    COS number must be 1 to 50 
    COS value is out of range Meaning 
    In Form 32, Customer Data Print, the COR value 
    specified must be valid (1 -+ 25 for each COR group). 
    There are a maximum of 50 COR groups. Refer to Form 
    20, ARS: Class of Restriction Groups. 
    Valid range for COS numbers is I to 50. 
    In Form 32, Customer Data Print, the COS value 
    specified must be valid (1 -+ 50). 
    The current associated set is using a key An attempt was made to change the association of a 
    on the PKM PKM while the associated set is using a line on the set. 
    Data port of the DNIC console must be The user is attempting to delete the DNIC console in 
    deleted first Form 07 without first deleting its data port in Form 12. 
    Database is out of sync The database copy in RAM does not match the 
    database copy on the CMOS. Delete the selected 
    device and re-enter the device in the appropriate form. 
    Delete ACD Group XX from ACD PATH YY The user attempted to delete the last agent from group 
    before deleting last agent XX, which would have the effect of deleting group XX 
    itself. However, group XX is referenced in the ACD 
    PATH form, for path number YY, so it must be deleted 
    from that form first. Then the user will be allowed to 
    delete the last agent, and thus delete the group. 
    Delete ACD Group XX from ACD The user attempted to delete the last agent from group 
    SUPERVISORS form before deleting last XX, which would delete group XX itself. However, group 
    agent XX is referenced in the ACD Supervisors form, so it must 
    be deleted from that form first. 
    Delete in Hunt Group Form first The user attempted to delete the last member of a hunt 
    group programmed as an overflow point, which would 
    delete the hunt group itself. The member must be 
    deleted from Form 17 first. 
    Delete trunkat Bay/Slot/Circuit-XX/XX/XX The system cannot configure the peripheral bay as an 
    before adding 2nd Tl ISDN Card. ISDN node because the 24th circuit of the first Tl Trunk 
    Card is programmed in either Form14 or Form 15. 
    Delete the trunk that is programmed on the 24th circuit 
    of the first Tl Trunk Card. 
    DISA trunks cannot have prefix or absorb The user was trying to program these fields for a DISA 
    digits programmed trunk. 
    DNIC console cannot originate a DTRX call The data port for a DNIC console cannot have the DTE 
    field in Form 12 filled out since it cannot originate a 
    DTRX. 
    DTE field is not programmed for this device First member of a modem hunt group has the DTE field 
    programmed. User attempted to add a member without 
    the DTE field programmed - must be consistent within 
    the hunt group. 
    DTE field is programmed for this device First member of a modem hunt group does not have the 
    DTE field programmed. User attempted to add a 
    member with the DTE field programmed - must be 
    consistent within the hunt group. 
    Page7ofl6 
    March 1997 Issue 1 Revision 0  
    						
    							Customer Data Entry 
    Table A-l Programming Error Messages (continued) 
    Error Message 
    Entered string is not in the system 
    Error in “*” sequences. * 
    (1,2,3,4,5,6,7,8,9,*) are the only valid 
    sequences Meaning 
    In Form 26, ARS Nested Digit Strings, the selected digit 
    string is not defined. 
    Theasterisksequence in the DIGITSTO BE INSERTED 
    field in Form 22, ARS: Modified Digit Table is restricted 
    to the following: 
    *1 = Pause for 5 seconds, 
    *2 = Wait for Dial Tone, 
    *3 = Switch to DTMF for subsequent digits, 
    *4 = Stop or start displaying modified digits. 
    Modified digits are displayed on the sets and in the 
    SMDR records. The first time *4 appears in a digit string 
    the system stops displaying the following modified 
    digits. The next time *4 appears the system starts 
    displaying the following modified digits. 
    *5 = Pause10 seconds, 
    *6 = Insert caller’s ID, 
    *7 = Inset-t caller’s dialed account code, 
    *8 =lnset-t PBX node ID number, 
    *9 =Pause for 1 second, 
    ** 
    = asterisk character. 
    Error in COR members. Use spaces The members for each COR group must be separated 
    between CORs. e.g. 1 3 5-14 25 by a space. For consecutive CORs, a dash is inserted. 
    Error in QTY TO DELETE field Can only Only 25 digits can be deleted. Refer to the QTY TO 
    delete up to 25 DELETE field in Form 22, ARS: Modified Digit Table. 
    Extn. XXXX can’t have a key template and A telephone may not be programmed with both a key 
    a SUP,E%ET DSS/PKM module at the template and an associated SUPERSET DSS or PKM 
    same time Module at the same time. 
    Extension number XXXXX does not exist The selected extension number is undefined. The 
    extension number must first be defined in Form 09, 
    Stations/SUPERSET Telephones. 
    Extension number XXXXX has not been That extension number is not in a paging group. 
    assigned a paging group 
    EXTENSION NUMBER XXXXX is a The selected extension number is a member of the hunt 
    member of HUNT GROUP XX group shown. An extension number can be a member 
    of only one hunt group at a time. 
    EXTENSION NUMBER XXXXX is a The selected extension number is a member of the 
    member of PICKUP GROUP XX pickup group shown. An extension number can be a 
    member of only one pickup group at a time. 
    FEATURE NUMBER XX conflicts with The given feature conflicts with the specified system 
    system option YY in Form 4 option in Form 4. The option and the feature access 
    code cannot be programmed at the same time. 
    Feature Number out of range Valid range is Feature numbers range from I to 45. Refer to Form 02, 
    (1 - 45) Feature Access Codes. 
    First account code position value greater When Print Option Number 14 in Form 32, Customer 
    than last Data Print is selected, the first specified account code 
    must be less than the last specified account code. 
    Page8of lc 
    A-8 Issue 1 Revision 0 March 1997  
    						
    							Appendix A - Programming Error Messages 
    Table A-l Programming Error Messages (continued) 
    Error Message 
    First digit in Access Code must be ‘*’ 
    First digit in digit string cannot be a ‘*’ 
    Form access disallowed; enable verified 
    account codes system option 
    Form number XX cannot be accessed Meaning 
    The Key System - Retrieve Personal Speed Call feature 
    access code must begin with an asterisk (*). 
    This will conflict with the Key System - Retrieve Personal 
    Speed Call. If asterisks (*) are required, program them 
    into the Modified Digit Table. 
    To access Form 33, Account Code Entry, System Option 
    05, Verified Account Code must first be enabled. Refer 
    to Form 04, System Options/System Timers. 
    The selected form number is reserved for future use or 
    the selected form number has restricted user access. 
    Refer to Form 28, Form Access Restriction Definition for 
    the level of access for each form. 
    Form number out of range 
    The selected form number is invalid. See Table 3-l. 
    High power card cannot be programmed at The Universal Card can only be assigned to those card 
    this Bay/Slot/Circuit slots rated for high power consumption. These are the 
    upper slots of any digital bay. 
    Hour value XX is out of range The hour value can range from 01 to 24. Refer to Form 
    04, System Options/System Timers. 
    Hunt group must have an access code The user attempted to program a name for the hunt 
    assigned before name can be programmed group before an access code was programmed. The 
    access code has to be done first. 
    Incorrect specification of Bay/Slot/Circuit The specified start bay/slot/circuit numbers must be less 
    for range programming than the end bay/slot/circuit numbers. 
    Inserted too many digits Up to 38 allowed, The specified entry exceeds the maximum. A maximum 
    with ‘*n’ counted as 1 of 38 entries are allowed in the DIGITS TO BE 
    INSERTED field in Form 22, ARS: Modified Digit Table. 
    Invalid default destination The user attempted to program an invalid default 
    destination for an auto attendant group. See Practice 
    9109-098-625NA, Automated Attendant Application 
    Package, for a list of valid destinations. 
    Invalid digit to insert Use O-9 or The specified entry is invalid. The entries in the DIGITS 
    “* (1,2,3,4,5,*)” only TO BE INSERTED field are restricted to the following: 
    - 0 to 9 and 
    - the valid asterisk sequences. 
    Invalid key for set in use The user attempted to program invalid keys (7 to 12) for 
    a SUPERSET 470 on expanded set forms for Form 09 
    and Form 45. 
    Key number XX cannot be programmed as This key can be an INTERCOM key, CO line key, CO 
    the Origination Line Preference key line group key, MANUAL, or PERSONAL O/G key. 
    Maximum ACD positions allowed are The user attempted to insert a 1000th ACD position into 
    already assigned the system. Only 999 are allowed. ACD positions 
    include agents, supervisors and senior supervisors. 
    Maximum Afterwork Timer is 15:OO The user entered a timer out of range. 
    Maximum Tl trunk cards are programmed. No more Tl trunk cards can be programmed. 
    Page9of 16 
    March 1997 Issue 1 Revision 0 A-9  
    						
    							Customer Data Entry 
    , Table A-l Programming Error Messages (continued) 
    Error Message Meaning 
    Maximum Time is 54:OO The user entered a timer out of range. 
    Minute value XX is out of range The minute value can range from 01 to XX, where XX 
    is option specific. Refer to Form 04, System 
    Options/System Timers. 
    MODIFIED DIGIT ENTRY out of range The selected entry number is invalid. The range is 1 to 
    Valid range is (1 - 50) 50. Refer to Form 22, ARS: Modified Digit Table. 
    Modified digit table entries are from 1 to 50 The selected entry number is invalid. The range is 01 to 
    50. Select a new entry number. Refer to Form 22, ARS: 
    Modified Digit Table. 
    Multiple QUEUE STATUS keys not allowed Multiple queue status keys are not allowed on an ACD 
    with AGENT STATUS keys supervisor key template when agent status keys are 
    programmed. 
    Must delete all appearances of XXX from This ACD path cannot be deleted, because its access 
    CALL REROUTING TABLE code appears in the CALL REROUTING table (Form 
    19). 
    Must delete all appearances of XXXXX 
    from CALL REROUTING TABLE The selected device must have its access code or 
    extension number deleted from the Call Rerouting Table 
    before it can be removed from the system. Refer to Form 
    19, Call Rerouting Table. 
    Must delete all appearances of XXXXX 
    from Key System Telephones Form This digit string is used in Form 45 as CO Line Group 
    Keys - must delete this first. Use the REVIEW form in 
    the Key Sets form to review the list of SUPERSETs 
    using this leading digit. 
    Must delete all appearances of XXX in 
    NON-DIAL-IN trunks This ACD path cannot be deleted because its access 
    code appears in the NON-DIAL-IN TRUNKS form (Form 
    14). 
    Must delete all appearances of XXX on all This trunk is programmed on a set as a CO line key in 
    sets before deleting trunk Form 45 - must delete there first. 
    Must delete all appearances of XXXXX in The user attempted to delete a device which is 
    Hunt Group Options form programmed in the Hunt Group Options form as a 
    default destination for auto attendant or an overflow 
    point. 
    Must delete all Digit Strings that begin with Before programming this access code, go to the SHOW 
    a ‘*Y 
    STRINGS subform of Form 26 - ARS: Digit Strings, and 
    delete all digit strings beginning with an asterisk (*). 
    Must delete all key definitions before The selected SUPE/?SETtelephone must have all its 
    deleting set key definitions deleted before it can be removed from 
    the system. Refer to Form 09, (Expand Set Subform) 
    SUPERSETTelephone Lines. 
    Must delete appearances of XXXXX from The selected device must have its access code or 
    answer points in NON-DIAL-IN TRUNKS extension number deleted from the answer points in 
    Form 14, Non-Dial-In Trunks before it can be removed 
    from the system. 
    PagelOof 16 
    A-10 Issue 1 Revision 0 March 1997  
    						
    							Appendix A - Programming Error Messages 
    Table A-l Programming Error Messages (continued) 
    Error Message Meaning 
    Must delete BLF appearances starting on The user attempted to delete a device which has BLF 
    device XXXX before deleting appearances on the specified device. The appearances 
    must be deleted first. 
    Must delete the appearances of XXXXX on All appearances of the station number (or prime line 
    all sets before deleting set number) must be deleted before that set can be 
    removed from the system. 
    Must enter first choice for route list to be In Form 24, ARS: Route Lists, the FIRST field must be 
    defined (leave no gaps) specified with a valid route list number before the 
    SECOND field is specified. 
    Must enter LEADING DIGITS To complete the entry in Form 26, ARS: Digit Strings, 
    must enter digits in the LEADING DIGITS field. 
    Must first disable Option 217 in COS (1 - 50) COS Option 217 Direct To ARS must be disabled before 
    the Direct To ARS feature access code can be deleted. 
    Must program Direct To ARS access code The user attempted to enable COS Option 217, Direct 
    first To ARS when there is no feature access code 
    programmed in Form 02 for this feature. Form 02 must 
    be programmed first. 
    Neither Option #248 Nor #249 are enabled One of these COS Options must be enabled for correct 
    W system operation. 
    No CONSOLE MODULES are The console module must be assigned to a 
    programmed bay/slot/circuit/subcircuit in Form 01, System 
    Configuration. 
    No DIAL-IN trunk cards are programmed A card that supports dial-in trunks must be defined in 
    Form 01, System Configuration. 
    No DNIC cards are programmed To access Form 45, there must be DNIC cards 
    programmed into Form 01. 
    No more space available for comments Subsequent comments that are entered in the CDE 
    Forms are not saved. 
    Non-existent account code value has been During a search in Form 32, Customer Data Print, the 
    entered entered account code does not exist. Select another 
    account code. 
    No NON-DIAL-IN trunk cards are 
    programmed 
    No STATION or SWE%Z7cards are 
    programmed A card that supports non-dial-in trunks must be defined 
    in Form 01, System Configuration. 
    A card that supports rotary dial or DTMF sets or a card 
    that supports SWE~SE~telephones must be defined 
    in Form 01, System Configuration. 
    No trunks are assigned to circuit descriptor The trunk circuit descriptor number entered has not 
    number X been specified in Form 13, Trunk Circuit Descriptors. 
    NUMBER OF DIGITS TO ABSORB must In the M field of Form 1.5, Dial-In Trunks, the maximum 
    be in the range (0 - 8) quantity of digits allowed is 8. 
    ONS limit exceeded for this part of Bay The maximum number of ONS cards allowed has been 
    exceeded. 
    ONS Port access code XXXXX does not The access code entered for the Music Source 
    exist Following a Recording is non-existent or illegal. 
    Page 11 of 1tZ 
    March 1997 Issue 1 Revision 0 A-l 1  
    						
    							Customer Data Entry 
    Table A-l Programming Error Messages (continued) 
    Error Message 
    Option XX conflicts with this option Meaning 
    The selected option is mutually exclusive with the option 
    number shown. 
    Option number XXX is out of range; must The selected option number is out of range. For COS 
    be between XXX and XXX Options, the valid range is 100 to 908. For System 
    Options, the valid range is 1 to 52. 
    Only 1 PER bay is allowed 2 Tl Trunk This message appears if you attempt to program a 
    cards, all others can only have 1 second Tl Trunk Card in more than one node. 
    Ovetflow Agent Groups must be unique The selected ovetflow agent group is a duplicate of an 
    overflow already specified for this path, or it is the 
    primary agent group for this ACD path. 
    Pager X is already assigned to a Night Bell. The pager number specified has already been assigned 
    to a Night Bell in this form. 
    Pager X is not programmed The selected pager is not a Music-on-Hold/Paging Unit. 
    The paging group XX has not been No members in specified group - group undefined. 
    assigned 
    The power rating of the UNIVERSAL CARD 
    The po.wer rating of the Universal Card is 10. Therefore, 
    is exceeded the number of modules that can be installed on the 
    Universal Card depends on the individual power rating 
    of the modules. The Receiver/Relay Module has a 
    power rating of 2, the Music on Hold/Pager Module has 
    a power rating of 1 and the E&M Trunk Module has a 
    power rating of 3. 
    Print Option out of range Valid range is In Form 32, Customer Data Print, there are only 50 print 
    (l-50) option numbers. Select a new print option number. 
    This printer specification has already been System already contains printer parameters. 
    programmed 
    Recording access code XXXXX does not The access code entered for a recording is non-existent 
    exist or illegal. The code must be for a recording hunt group. 
    Recording 1 Stat-l Time must be > = Delay The values for these two items must be adjusted as 
    For Ringback indicated. 
    ROUTE LIST out of range 
    Valid range is The selected route list number is invalid. The range is 1 
    (1 - 100) to 100. Refer to Form 24, ARS: Route Lists. 
    ROUTE out of range Valid range is (1 - The selected route number is invalid. The range is 1 to 
    200) 200. Refer to Form 23, ARS: Route Definition. 
    ROUTE PLAN out of range Valid range is The selected route plan number is invalid. The range is 
    (1 - 50) 1 to 50. Refer to Form 25, ARS: Route Plans. 
    RTE PLN= X, DZ= X, TZ= X, Field= ROUTE 
    The entered route list number does not have a 
    LIST Error= entry must be blank corresponding entry in the START HOUR field. 
    Therefore, the ROUTE LIST field must be cleared or a 
    starting time must be specified in the START HOUR 
    field. Refer to Form 25, ARS: Route Plans. 
    Page 12 of 16 
    A-12 Issue 1 Revision 0 March 1997  
    						
    							Appendix A - Programming Error Messages 
    Table A-1 Programming Error Messages (continued) 
    Error Message Meaning 
    RTE PLN= X, DZ= X, TZ= X, Field= START The START HOUR field entry is less than or equal to 
    HOUR, Error = Entry c = previous entry the previous START HOUR field entry. The entries in 
    the START HOUR field must be listed in ascending 
    order. Refer to Form 25, ARS: Route Plans. 
    RTE PLN= X, DZ= X, TZ= X, Field= START A blank entry in the START HOUR field represents 24 
    HOUR, Error= Entry cannot be deleted hours. Therefore, the subsequent entry in the START 
    HOUR field is less than or equal to the blank entry. 
    Starting times must be listed in ascending order. Refer 
    to Form 25, ARS: Route Plans. 
    Start time of a recording must be c Inter-flow Adjust the start time as indicated. 
    timeout 
    Start time of a recording must be -C start time The recording start times should be adjusted as 
    of the next recording indicated. 
    A sub-attendant prime cannot have keyline The line must be a single appearance (the prime) in the 
    or multi-call line appearances system. 
    The SWE/?SE~specified and the PKM The module and the set have been programmed with 
    have the same feature key the same feature key. 
    The SWEWETspecified and the PKM An attempt was made to move a PKM to a set that 
    have the same key line key already has an appearance of a DTS, PRIVATE or KEY 
    line that is already on the module. 
    Supervisor XXXXX does not exist A supervisor with ID XXXXX cannot be displayed as 
    requested via the FIND SUPER key because this 
    access code has not been assigned to a supervisor. 
    System Option XXconflicts with FEATURE The given system option conflicts with the specified 
    NUMBER YY in Form 2 feature number in Form 02. The option and the feature 
    access code cannot be programmed at the same time. 
    System Option 106 must be disabled This option must be disabled before auto attendant 
    groups can be programmed. 
    System Option 106 must be enabled This option must be enabled before auto attendant 
    groups can be programmed. 
    System Option 59 must be programmed This option must have a value programmed before an 
    before creating an Auto-Attendant group auto attendant group can be programmed. 
    Tl card (for ISDN Node) in slot 2,4,6,8 only Program ISDN Node Tl cards only in slots 2, 4, 6, or 8. 
    Tl card (for PER Node) in 5th or 6th slot Program PER Node Tl cards only in slots 5 or 6. 
    only 
    TENANT NUMBER is out of range Valid There are a maximum of 25 tenant groups. 
    range is 1 to 25 
    Toomanyagentsprogrammed,mustdelete The maximum number of agents allowed by your 
    some System ID has been reached. Additional agents cannot 
    be programmed. 
    Too many devices programmed, must 
    delete some The maximum number of devices allowed by your 
    System ID has been reached. Additional agents cannot 
    be programmed. 
    Page 13 of 16 
    March 1997 Issue 1 Revision 0 A-13  
    						
    							Customer Data Entry 
    Table A-l Programming Error Messages (continued) 
    Error Message Meaning 
    TOTAL DIGITS EXPECTED must be in the in Form 15, Dial-In Trunks, the N field (total digits 
    range (1-Q) expected) is restricted to digits 1 to 9. (Generic 1004 
    and below). 
    TOTAL DIGITS EXPECTED must be in the In Form 15, Dial-In Trunks, the N field (total digits 
    range (0 - IO) expected) is restricted to digits 0 to 10. 
    (L/G/-/TWA/?E only). 
    Total string is too long Limit is 26 digits The total number of digits in the DIGITS TO BE 
    ANALYZED field plus the digits in the LEADING DIGITS 
    field cannot exceed 26. Refer to Form 26, ARS: Digit 
    Strings. 
    TRUNK NUMBER XX does not correspond Trunk number entered was either a dial-in trunk or a 
    to a CO trunk non-existent trunk. Only non-dial-in trunks may be 
    entered here. 
    Only CO trunks can be assigned as DTS in Form 09, 
    (Expand Set Subform) SU/?E/%%TTelephone Lines. 
    TRUNK NUMBER XXX is already assigned Trunk numbers can be assigned to only one trunk. Trunk 
    numbers are assigned in Form 14, Non-Dial-In Trunks 
    and Form 15, Dial-In Trunks. 
    TRUNK NUMBER XXX has not been Entered trunk number does not correspond to a trunk. 
    assigned It must be defined in Form 14, Non-Dial-In Trunks or 
    Form 15, Dial-in Trunks. 
    TRUNK GROUP must be entered for a To complete the route definition, the trunk group number 
    route to be defined must be specified. Refer to Form 23, ARS: Route 
    Definition. 
    TRUNK NUMBER XXX is a member of 
    TRUNK GROUP XX The selected trunk number is a member of the trunk 
    group shown. A trunk number can be a member of only 
    one trunk group at a time. 
    Unable to delete - A device is programmed Circuits are assigned to the selected card in that bay 
    for the Bay/Slot/Circuit - XX/XX/XX and slot. Cannot delete the card in that slot until the 
    devices are de-assigned from the forms. 
    Unable to locate extension XXXXX The selected extension number is not assigned to any 
    station or set. Refer to Form 09 or Form 45. 
    Unable to locate extension XXXXX The selected extension number is not assigned to any 
    assigned to a PICKUP GROUP station or set. Refer to Form 09 or Form 45. 
    Unable to stop CDE print Try again later The customer data print process cannot be halted. Try 
    again later. 
    Undefined index number or digit string In Form 31, System Abbreviated Dial Entry, either the 
    Index Number or the Digit String is blank. Specify the 
    required Index Number or Digit String. 
    Unmatched Account code length; system The length of the entered account code does not match 
    option account code length enabled the account code length specified in System Option 55. 
    (See Form 04, System Options/System Timers). Enter 
    a newaccountcode orchange the Account Code Length 
    option. 
    Pagel4ofl6 , 
    A-14 Issue 1 Revision 0 March 1997  
    						
    All Mitel manuals Comments (0)

    Related Manuals for Mitel Sx 200 Ml Pabx Lightware 16 Instructions Guide