    							Cabling and Cross Connections 
    Table 7-2 Digital Bay Tip and Ring Assignments (High-power Slots) (continued) 
    J5 and J9 for Digital Bay 1 
    Lead Designation 
    Slot Plug Pin Pair Cct ONS or Cct LS/GS Cct COV Cct OPS or 
    DLC DID 
    13 
    G-BK SPARE 
    39 BK-BR 1 Tl 1 Tl 1 Tl 
    1 Tl 
    14 BR-BK Rl Rl Rl Rl 
    40 BK-S 2 T2 MM1 2 T2 
    15 S-BK R2 Ml R2 
    41 Y-BL 3 T3 
    2 T2 3 T3 2 T2 
    5 J5 16 BL-Y R3 R2 R3 R2 
    or 42 Y-O 4 T4 
    MM2 4 T4 
    7 J9 17 
    O-Y R4 M2 R4 
    43 
    Y-G 5 T5 3 T3 5 T5 3 T3 
    18 
    G-Y R5 R3 R5 
    R3 
    44 Y-BR 6 T6 
    MM3 6 T6 
    19 BR-Y R6 M3 R6 
    45 Y-S 7 T7 4 T4 
    4 T4 
    20 S-Y R7 R4 R4 
    46 V-BL 8 T8 MM4 
    21 BL-V R8 M4 
    47 v-o 9 T9 5 T5 
    5 T5 
    22 o-v R9 R5 R5 
    48 V-G 10 TlO MM5 
    23 G-V RlO M5 
    49 V-BR 11 Tll 6 T6 
    6 T6 
    24 BR-V Rll R6 R6 
    50 v-s 12 T12 
    MM6 
    25 s-v Rl2 M6 
    Page 2 of 2 
    March 1997 
    Issue 1 Revision 0 7-3  
    						
    							Installation Information 
    Table 7-3 Tip and Ring Assignments for Universal Card Modules 
    I 
    J5 and J9 for Digital Bay 1 
    Slot Plug 
    6 
    or J5 
    8 J9 
    xii Pair 
    26 W-BL 
    1 BL-W 
    27 w-o 
    2 o-w 
    28 
    W-G 
    3 G-W 
    29 W-BR 
    4 BR-W 
    30 
    w-s 
    5 s-w 
    31 R-BL 
    6 BL-R 
    32 
    R-O 
    7 O-R 
    33 R-G 
    8 G-R 
    34 R-BR 
    9 BR-R 
    35 R-S 
    10 S-R 
    36 BK-BL 
    11 BL-BK 
    37 BK-0 
    12 0-BK 
    38 BK-G 
    T 
    cct 
    1 
    2 
    3 
    4 MOH/ 
    Pager 
    MIA1 
    MlBl 
    POAl 
    POBl 
    PKAl 
    PKBl 
    MIA2 
    MlB2 
    POA2 
    POB2 
    PKA2 
    PKB2 
    MIA3 
    MlB3 
    POA3 
    POB3 
    PKA3 
    PKB3 
    MIA4 
    MlB4 
    POA4 
    POB4 
    PKA4 
    PKB4 cct DTMF 
    Relay 
    K5Al 
    K5Bl 
    K6Al 
    K6Bl 
    K5A2 
    K5B2 
    K6A2 
    K6B2 
    K5A3 
    K5B3 
    K6A3 
    K6B3 
    K5A4 
    K5B4 
    K6A4 
    K6B4 
    I3 
    E&M 
    Trunk 
    Tl 
    Rl 
    TRl 
    RR1 
    El 
    Ml 
    T2 
    R2 
    TR2 
    RR2 
    E2 
    M2 
    T3 
    R3 
    TR3 
    RR3 
    E3 
    M3 
    T4 
    R4 
    TR4 
    RR4 
    E4 
    M4 
    Page 1 of 2 
    7-4 Issue 1 Revision 0 March 1997  
    						
    							Cabling and Cross Connections 
    Table 7-3 Tip and Ring Assignments for Universal Card Modules (continued) 
    J5 and J9 for Digital Bay 1 
    Slot Plug Pin Pair Cct MOH/ Cct DTMF Cct E&M 
    Pager Relay 
    Trunk 
    13 G-BK 
    39 BK-BR 1 MIA1 1 1 
    Tl 
    14 BP,-BK MlBl Rl 
    40 BK-S POAl K5Al 
    TRl 
    15 S-BK POBl K5Bl RR1 
    41 Y-BL PKAl K6Al 
    El 
    5 J5 16 BL-Y PKBl K6Bl Ml 
    or 
    42 Y-O 2 MIA2 2 2 T2 
    7 J9 
    17 O-Y MlB2 R2 
    43 Y-G POA2 K5A2 
    TR2 
    18 G-Y POB2 K5B2 RR2 
    44 Y-BR PKA2 K6A2 E2 
    19 BR-Y PKB2 K6B2 M2 
    45 Y-S 3 MIA3 3 3 T3 
    20 S-Y MlB3 R3 
    46 V-BL z POA3 K5A3 
    TR3 
    21 BL-V POB3 K5B3 RR3 
    47 
    v-o PKA3 K6A3 
    E3 
    22 o-v PKB3 K6B3 M3 
    4% V-G 4 MIA4 4 4 
    T4 
    23 G-V MlB4 R4 
    49 V-BR POA4 K5A4 TR4 
    24 BR-V POB4 K5B4 RR4 
    50 v-s PKA4 K6A4 
    E4 
    25 s-v PKB4 K6B4 
    M4 
    Page 2 of 2 
    March 1997 Issue 1 Revision 0 7-5  
    						
    							installation Information 
    Table 7-4 Tip and Ring Assignments (Low-power Slots) 
    J7and Jll 
    Slot Plug Pin Pair 
    cct Lead Designation 
    ONS or cct LWGS 
    DLC 
    2 
    4 or J7 
    Jll 26 w-f3L 
    I BL-W 
    27 w-o 
    2 o-w 
    28 W-G 
    3 G-W 
    29 W-BR 
    4 BR-W 
    30 w-s 
    5 s-w 
    31 R-BL 
    6 BL-R 
    32 R-O 
    7 
    O-R 
    33 R-G 
    8 G-R 
    34 R-BR 
    9 BR-R 
    35 R-S 
    10 S-R 
    36 BK-BL 
    11 BL-BK 
    37 BK-0 
    I2 0-BK 
    38 BK-G 1 
    2 
    3 
    4 
    5 
    6 
    7 
    8 
    9 
    10 
    11 
    12 Tl 1 Tl 
    Rl Rl 
    T2 MM1 
    R2 Ml 
    T3 2 T2 
    R3 R2 
    T4 MM2 
    R4 M2 
    T5 3 T3 
    R5 
    R3 
    T6 MM3 
    R6 
    M3 
    T7 4 T4 
    R7 R4 
    T8 MM4 
    R8 
    M4 
    T9 5 T5 
    R9 
    R5 
    TlO MM5 
    RlO 
    M5 
    Tll 6 T6 
    Rll 
    R6 
    Tl2 MM6 
    Rl2 
    M6 
    SPARE 
    Page 1 of 2 
    7-6 Issue 1 Revision 0 March 1997  
    						
    							Cabling and Cross Connections 
    Table 7-4 Tip and Ring Assignments (Low-power Slots) (continued) 
    J7and Jll 
    Slot Plug Pin Pair 
    cct Lead Designation 
    ONS or cct 
    LSIGS 
    DLC 
    1 
    3 or J7 
    Jll 13 G-BK 
    39 
    BK-BR 
    14 BR-BK 
    40 BK-S 
    5 S-BK 
    41 Y-BL 
    16 BL-Y 
    42 Y-O 
    17 O-Y 
    43 Y-G 
    18 G-Y 
    44 Y-BR 
    19 BR-Y 
    45 Y-S 
    20 S-Y 
    46 V-BL 
    21 BL-V 
    47 
    v-o 
    22 o-v 
    48 V-G 
    23 G-V 
    49 V-BR 
    24 BR-V 
    50 v-s 
    25 s-v 1 
    2 
    3 
    4 
    5 
    6 
    7 
    8 
    9 
    10 
    11 
    12 SPARE 
    Tl 1 Tl 
    Rl Rl 
    T2 2 
    MM1 
    R2 Ml 
    T3 2 T2 
    R3 R2 
    T4 
    MM2 
    R4 M2 
    T5 3 
    T3 
    R5 R3 
    T6 
    MM3 
    R6 M3 
    T7 4 
    T4 
    R7 R4 
    T8 MM4 
    R8 M4 
    T9 5 T5 
    R9 R5 
    TlO MM5 
    RlO M5 
    Tll 6 
    T6 
    Rll R6 
    T12 
    MM6 
    T12 M6 
    Page 2 of 2 
    March 1997 Issue 1 Revision 0 7-7  
    						
    							Installation Information 
    Table 7-5 USOC Connector Pin Designations 
    Connector Type 
    1 RJ2lX 
    26 W-BL 
    T 
    1 BL-W R 
    27 
    w-o T 
    2 o-w 
    R 
    28 W-G T 
    I 3 I G-W 
    1 R 
    29 W-BR T 
    4 BR-W 
    R 
    I 30 
    I 
    5 s-w R 
    31 R-BL 
    T 
    6 BL-R R 
    32 R-O T 
    7 
    O-R R 
    33 R-G T 
    8 G-R 
    R 
    34 R-BR T 
    9 BR-R 
    R 
    35 
    R-S T 
    10 S-R R 
    36 BK-BL T 
    11 
    BL-BK R 
    I 37 I BK-0 
    1 -r 
    12 
    0-BK R RJ2EX 
    T 
    R 
    E 
    M 
    T 
    R 
    E 
    M 
    T 
    R 
    E 
    M 
    T 
    R 
    E 
    M 
    T 
    R 
    E 
    M RJ2GX 
    T 
    R 
    Tl 
    Rl 
    E 
    M 
    T 
    R 
    E 
    M 
    Page 1 of 2  T 
    R 
    Tl 
    Rl 
    E 
    M 
    T 
    R 
    Tl 
    Rl 
    E 
    M 
    T 
    R 
    Tl 
    Rl 
    E 
    M 
    7-8 
    Issue 1 Revision 0 March 1997  
    						
    							Cabling and Cross Connections 
    Table 7-5 USOC Connector Pin Designations (continued) 
    I Connector Type 
    RJ2EX 
    T 
    R 
    E 
    M 
    T 
    R 
    E 
    M 
    T 
    R 
    E 
    M 
    T 
    R 
    E 
    M 
    T 
    R 
    E 
    M 
    T 
    R 
    E 
    M 
    SPARE 
    RJ2GX 
    T 
    R 
    Tl 
    Rl 
    E 
    M 
    T 
    R 
    Ti 
    Rl 
    E 
    M 
    T 
    R 
    Tl 
    Rl 
    E 
    M 
    T 
    R 
    Tl 
    Rl 
    E 
    M 
    Page 2 of 2 
    Note: 1. RJ21 X is a standard trunk. 
    2. RJ2EX is a two-wire E&M trunk. 
    3. RJ2GX is a four-wire E&M trunk. 
    March 1997 
    Issue 1 Revision 0 7-9  
    						
    							installation Information 
    7-10 
    Issue 1 Revision 0 
    March 1997  
    						
    							Appendix A 
    , 
    Peripheral Device 
    Connection to the Digital 
    Line Card 
    Loop Length Specifications 
    A.1 The following rules for loop lengths between the Digital Line Card within the PABX 
    and the SUPERSET 401+, SUPERSET 4 IO, SLJPERSET 420, and SUPERSET 430 
    telephones, or SUPERCONSOLE 7000 Attendant Console must be followed for prop- 
    er operation of the device: 
    Maximum loop length (twisted pair) 24 or 26 AWGsee Table A-l 
    Maximum length of quad cable (22 AWG) 
    50 m (I 60 ft) 
    Modular Line Cord 
    3 m (10 ft) 
    Telephone, 
    Module, or 
    Console  PABX MDF IDF 
    Modular 
    Connector 
    - 24 or 26 AWG twisted - 50 m maximum 22 - 3m 
    pair cable (see Table) 
    AWG quad Modular 
    maximum 
    March 1997 Issue 1 
    Revision 0 A-l  
    						
    							Installation Information 
    Table A-l Loop Lengths for Digital Peripheral Devices 
    I Peripheral Maximum Loop Length 
    Without Bridge Tap With Bridge Tap 
    Note: Peripherals connected to Digital Line Card 9109-012-001 -NA cannot have bridge taps. 
    A-2 issue 1 Revision 0 March 1997  
    						