Appendix B - Blank CDE Forms FFORM 09 - “EXPAND PKWSUBFORM Programmable Key Module Lines Sheet of PKM/KEY TYPE DIR RING 1 SEC 1 DSS EXJ NUM TRK NUM WBEL I 01 1 Prime 1 In/Out 1 lmmed 1 No 1 No 1 I I I 03 04 05 06 07 I I I I I I I I oq 09 10 11 12 13 14 15 16 t 17 18 19 20 21 22 29 30 31 32 The PKM is only associated with SUPERSE~470, SUERSE~420, and SUPERSET telephones. March 1997 issue 1 Revision 0 B-19
Customer Data Entry FORM 10 - PICKUP GROUPS sheet of GROUP NUMBER (I- 50): EXTENSION NUMBERS I GROUP NUMBER (1 - 50): GROUP NUMBER (I - 50): B-20 Issue 1 Revision 0 March 1997
Appendix B - Blank CDE Forms FORM II - DATA CIRCUIT DESCRIPTORS DESCRIPTOR NUMBER OF DATA CIRCUITS ASSIGNED l COMMENTS 1 12 13 17 18 19 20 21 22 23 24 25 *This field is automatically updated by the system based on entries in Form 12. 1 March 1997 Issue 1 Revision 0 B-21
Customer Data Entry DATA CIRCUIT DESCRIPTOR Ol=WOlVS ‘Select Option” Subform of Form I I 1 DATA CIRCUIT DESCRIPTOR NUMBER (1 - 25) OPTION NAME 1 -’ i-21 -3 l-4 l-5 1-6 l-7 l-8 l-9 I-0 Session Inactivity Disconnect Timer 0 - 255 minutes Guard Timer 0 - 99 seconds Minimum Baud Rate 110,150,300,600, 1200,2400,4800,9600 or 19.2K Default Baud Rate 110,150,300,600,1200,2400,4800,9600 or 19.2K Maximum Baud Rate 110, 150,300,600,1200,2400,4800,9600 or 19.2K Always Use Default Baud Rate When Called YES or NO DTR Off Disconnect Timer 0 - 99 seconds DTR to CTS Delay Timer 0 - 9900 msec (100 msec increments) DTR Forced High YES or NO RTS Forced High YES or NO DSR is Held High When Device is Idle YES or NO CTS is Held High When Device is Idle YES or NO Originate A DTRX Call With a Low +-High of DTR Transition R YES or NO I II I I I I I II Action Taken if the Idle DTE has DTR Low (Auto-An- swer) TOGGLE RI, RAISE DSR, RAISE DCD or REFUSE Pooled Modem Communication Established lndica- tor DCD or DSR First Modem Tone 2025,210O or 2225 Hz Second Modem Tone 2025,210O or 2225 Hz ASYNC: Keyboard Origination Allowed (Auto Baud) YES or NO $4 ASYNC: ADL Auto Baud YES or NO ASYNC: Flow Control CTS, XON/XOFF, NONE, PIN 25HVCTS or PIN I I I I I I I I I I 25LO/CTS I I Page 1 of 2 B-22 Issue 1 Revision 0 March 1997
Appendix B - Blank CDE Forms DATA CIRCUIT DESCRIPTOR NUMBER (1 - 25) OPTION NAME ASYNC: XON Character 0 -127, Decimal value of ASCII code ASYNC: XOFF Character 0 -127, Decimal value of ASCII code ASYNC: Break Key Function SYS ATT or TRANSPARENT ASYNC: PBX Attention Character 0 -127, Decimal value of ASCII code ASYNC: Parity ODD, EVEN, NONE, SPACE or MARK ASYNC: Character Length 7 or 8, 8 implies *no parity” ASYNC: Number of Stop Bits 1 or2 -1 -2 -3 -4 -5 -6 -7 -a -9 -0 ASYNC: Autobaud to Host Character 1 0 -127, Decimal value of ASCII code ASYNC: Autobaud to Host Character 2 0 -127, Decimal value of ASCII code ASYNC: Delay Between Autobaud Characters 0 - 1270 msec (10 msec increments) DS2lOO:Operating Mode ASYNCHRONOUSorSYNCHRONOUS SYNC: Rate Adaptation Scheme MiNET or X.31 SYNC: Clock Source INTERNAL, SYSTEM, TX EXT or TX & RX EXT Page 2 of : March 1997 issue 1 Revision 0 B-23
Customer Data Entry FORM 12 - DATA ASSIGNMENT Sheet of B-24 Issue 1 Revision 0 March 1997
Appendix B - Blank CDE Forms FORM 13 - TRUNK CIRCUIT DESCRIPTORS DESCRIPTOR TRUNK TYPE COMMENTS 1 I 2 I 3 4 I 5 I 6 I 7 8 9 10 11 12 13 14 15 16 17 18 19 I 20 I I I 21 I 23 I 24 I 25 I March 1997 Issue 1 Revision 0 B-25
Customer Data Entry 4Circuit CO/4-Circuit DISA Tanks ‘Select Option” Subfotm of Form 13 sheet of 4-CIRCUIT CO TRUNK and TRUNK CIRCUIT DESCRIPTOR NUMBER (1 - 25) 4-CIRCUITDISATRUNKOPTIONS Page 1 of 11 B-26 Issue 1 Revision 0 March 1997
Appendix B - Blank CDE Forms 6-Circuit CO/6-Circuit DISA Tanks ‘Select Optiod Subfom of Form 13 Sheet of Page I of 1 March 1997 Issue 1 Revision 0 B-27
Customer Data Entry E&M Module/ E&M Module USA links ttSelect Option” Subfom of Form 13 Sheet of E&M MODULE and TRUNK CIRCUIT DESCRIPTOR NUMBER- E&M MODULE DISA OPTIONS Outgoing Start Type Outpulse Delay Timer 100 - 2000 ms (100 ms inc) Flash Timer 200 - 700 ms (100 ms inc) Flash Type LOOP FLASH or RING GROUND Flash Over Trunk YES or NO Interdigit Timer 300 - 800 ms (100 ms inc) Wait For Delay Timer 300 - 5000 ms (100 ms inc) Remote End is a Satellite YES or NO Remote End is a Satellite with OPS LinesYES or NO Page I of I 1 I I B-28 Issue 1 Revision 0 March 1997